Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval (2)
I BCIS Home f Log In f User Registration I Hot Topic ! Submit Surcharge t Stats&Facts I Publications F Contact Us BCIS Site Map ( Links ( Search doprodda Product Approval .USER:Public User Product Approval Menu>Product or Aoolicatlon Search>Application List>Application Detail @ FL# FL20838-R2 q'? Application Type Affirmation Code Version 2017 a Application Status Approved t� 3 Comments Archived [) r4 Product Manufacturer Custom Window Systems Inc. " Address/Phone/Email 1900 SW 44th Avenue <- Ocala,FL 34474 1 (35 368-6922 Ext291 � jlathrop@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative Stephen Brooks *ice Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (35 368-6922 Ext255 sbrooks@cws.cc ME ks OO A Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 r ' (352) 368-6922 Ext 291 jlathrop@cws.cc Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Certification Mark or Listing c � Certification Agency Keystone Certifications,Inc. Validated By Steven M. Urich,PE O Validation Checklist-Hardcopy Received s s t ='r Referenced Standard and Year(of Standard) Standard Year I AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E 1886 2005 �- ASTM E 1996 2009 .,f. TAS /2 2 1994 Equivalence of Product Standards Certified By h'tps://www.floridabuilding.org/pr/pr_app_dtl.aspx?par,am=wGE...PgODTr%2bXw3llhpg57t2LrfTwU%2bnoGogvBGdB206JA%3d%3d 8120/19,4:16 PM Page 1 of 3 @I affirm that there are no changes in the new Florida Building ` Code which affect my product(s)and my product(s)are in compliance with the new Florida Building Code. -W Documentation from approved Evaluation or Validation Entity QYes``,)'No ON/A LF 20838_R2 COC 6thEdFBC-FL20838.odf Product Approval Method Method 1 Option A $ "- Date Submitted 08/09/2017 i Date Validated 08/09/2017 s r Date Pending FBC Approval Date Approved 08/15/2017 �. Summary of Products Model,Number or Name Description ` " I 20838.1 SGD 8800 Sliding Glass Door 8800 Series-W X 8' Panels Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL20838 RZ_C CAC 138-1394CAR.pdf Approved for use outside HVHZ:Yes FL20838 RZ C_CAC 138-1395CAR.pdE $ Impact Resistant:Yes FL20838 R2 C CAC 138-1397CAR.pdf Design Pressure:N/A FL20838 R2 C CAC 138-1398CAR.pdf I Other:Impact vinyl sliding glass door with light FL20838 R _C_CAC_138-569CAR.pd s, 4 reinforcement,standard sill riser,and annealed laminated 838 82 C CAC 138-570CAR.p 3 glass to+/-DP50. Design pressure+/-65 with light Quality Assurance Contract Expiration Date reinforcement,standard sill riser,&heat strengthened 04/18/2020 laminated glass. Installation Instructions FL20838 R2 II CWS-1150-RI.odf Verified By: Lucas Turner FL PE 58201 Created by Independent Third Party:Yes Evaluation Reports FL20838 R2AE valReport1150-111.pdf p Created by Independent Third Party:Yes 20838.2' SGD 8800 Sliding Glass Door 8800 Series`-5 X 8'Panels Limits of Use,- Certification.Agency Certificate ' Approved for'use in HVHZ Yes 20838 k2,C.CAC 138-1601CAR.odf` -Approved for use outside HVHZ Ye§. - FL20838 R2 C CAC 138-1602CAR.pdf Iinpact'Resistant:Yes'- 20838 97"C CAC 138-571CAR.p "•, = ?Design Pressure:+80%--80 Quality Assurance.Contractfxpiration,Date Other.Impact vinyl sliding glass door with`heavy '04/22/2020 reinforcement and high sill riser to+/ DP80; Installation Instructions- FL20838 R2 II CWS-1151-Rlpdf Verified By:Lucas Turner FL PE 58201 1 Createil"by Independent Third Party:Yes Evaluation Reports,-. FL20838 AE EyalReoortll'51-Rl.od 7 F Created by Independent Third"Party:Yes t 20838.3 SGD 8800 Sliding Glass Door 8800 Series-4'X 10'Panels Limits of Use Certification Agency Certificate _ Approved for use in HVHZ:Yes FL20838 R2 C CAC 138-1610CAR. Approved for use outside HVHZ:Yes FL20838_R2 C CAC 138-1611CAR.pdf �1 Impact Resistant:Yes FL20838 R2 C CAC 138-573CAR.pd " Design Pressure: +65/-65 Quality Assurance Contract Expiration Date Other:Impact vinyl sliding glass door with heavy 05/11/2020 reinforcement and standard sill riser to+/-DP65. Installation Instructions jFL20838 9211CWS-1152-Rl.pdf # Verified By: Lucas Turner FL PE 58201 r Created by Independent Third Party:Yes Evaluation Reports i FL2083 AE Ev e ort1152-R1.p� Created by Independent Third Party:Yes 0 0 htitps://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGE...PgODTr%2bXw3llhpg57t2LrfTwU%2bnoGogvsGdB206JA%3d%3d 8/20/19,4:16 PM Page 2 of 3 I i s _ Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 ti i a The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic -, mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have "�. one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. --"s Product Approval Accepts: Credit Card w f I https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGE...PgODTr%2bXw3llhpg57t2LrfTwU%2bnoGogvBGdB206JA%3d%3d 8/20/19,4:16 PM Page 3 of 3 GENERAL NOTES: /% �7/7(�j� y� SLIDING GLASS DOOR - LARGE MISSILE IMPACT 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND \ls'(ftf�L(yl!//r • WINDOW SYSTEMS MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING 1900 SW 44TH AVE. CODE(FBC),CURRENT EDITION AND IS RATED FOR USE IN THE OCALA,FLORIDA 34474 HIGH VELOCITY HURRICANE ZONE(HVHZ)AND IS RATED FOR WNW.CWS.CC WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. 185 g"4 PANEL WIDTH• Z GLAZING OPTIONS:(SS SHEET 3) 8800 PVC 481.�„ SLIDING GLASS 16 3.APPROVED CONFIGURATIONS INCLUDE BUT ARE NOT DOOR-IMPACT MAX.PANEL WIDTH LIMITED TO: A POCKET "XO""OX" 'HOC""OXO""XXX""OXXO""XXXX" "PX""PXX'"PXXX""PXXXX","PXXP","PXXXXP',"PXXXXXXP", "PXXXXXX)CXP' di 2 TRACK,3 TRACK,4 TRACK F 40�,"GLASS DLO II 4.DESIGN PRESSURE RATING: r I II NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE r rl II I AND GLASS TABLES ASTM E-1300-04. m 96„ II -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE, Z MAX, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES UNIT B I II C B ASTM E-1300-04. HEIGHT II 11 Z j II BN 5.ANCHORAGE:THE 33113%STRESS INCREASE HAS NOT BEEN OLU 932," I 11 USED IN THE DESIGN OF THIS PRODUCT.SEE SHEETS 10-11 p MAX. I X X II X X I F FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 HPA EL EIGHT I II 12 WAS USED FOR WOOD ANCHOR CALCULATIONS. w � II G 6.PRODUCT APPROVED FOR IMPACT USE. SHUTTERS ARE NOT 64�'� II GLASS REQUIRED. O II DLO Z .ALL FRAMES ARE PROCESSED AND II 7 TOGETHERED .V NTS REP ROC SSEDANSCRTHERMAL WELDED ,``�0 V40REK, � II II 8.SERIES/MODEL DESIGNATION SGD-8800. �,•' No 5B201 :�-P LLi � � 'Q • 9.THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING: o: - A X=OPERABLE SASH,0=FIXED SASH,P=OCKET/HOOKSTRIP '9: STATE OF E D A TORN*.,A, p �: 12 12 11 10.SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS IN A 4��Fs. O..10.✓����� SIMILAR LOCATION. 11.WEEP SLOTS=1/2'x 1"LOCATED @ BOTH ENDS. ro o 7/6/2016 04 Q ^o LUCAS A.TURNER,P.E. m 9 FL PE#58201 8.E o 1239 JABARA AVE. J~N N NORTH PORT,FL 34288 PH.941-380-1574 TABLE OF CONTENTS SHEET DESCRIPTION: GENERAL NOTES 8 ELEVATIONS.... DESIGN PRESSURE GLASS TYPE GENERAL NOTES AND ELEVATIONS RATING SECTION VIEWS. 2 MAX.PANEL SIZE SEE SHT 4 IMPACT RATING 80M&GLAZING DETAIL....................3 ( � DRAWN BY: DATE: EXTRUSIONS...................................4-5 +/-50 PSF A LARGE MISSILE BLZ 05/06/16 TRACK WIDTHS..................................6 48-15/16"x 93-3/8" +/-65 PSF B IMPACT DWG#: REV.: ANCHOR SCHEDULE&NOTES ANCHOR PATTERNS......................8-9 CVVS-1150 - INSTALLATION DETAILS.............10-11 •(4)PANELS SHOWN;HVHZ LIMITED TO MAX.(9)PANELS. OUTSIDE HVHZ,UNLIMITED NUMBER SCALE: SHEET OF PANELS IS ALLOWABLE AS LONG AS INDIVIDUAL PANELS DO NOT EXCEED PANEL SIZE AS SHOWN. 1:30 1 OF 11 C 41 28 11 40 WINDOW SYSTEMS 35 14 1900 SW 44TH AVE. 34 34 12 OCALA,FLORIDA 34474 60 38 � WWWCWS.CC 14 10 a a 29 23 �] 8800 PVC 39 28 56 P 34 14 SLIDING GLASS a �� 39 DOOR -IMPACT 30 19,20,21,58 [� 34 36 14 � Q El 15 O LI 33 19.20,21,58 12 oP m 16 34 14 Z 36 SECTION VIEW B-B 6 O o 13 Vj 68 39 O w 6 CI�JO G 0 G O07U 0_ IL'"'��IuIL�Ji U� W O 12 O Z 54,55 ttpttnn4q� p% Pp1ORE4V 36 G 59 13 � GENg�GA2%'. q No 58201 VA 16 390: .STATE OF :�k/ o FIXED PANEL 33 ATTACHMENT a o 36 7/6/2016 32 17 LUCAS A.TURNER,P.E. FL PE#58201 8 1239 JABARA AVE. 23 NORTH PORT,FL 34288 63 PH.941-380-1574 ® ® ® ® ® SHEET DESCRIPTION: 3 �0 % �0 Qou SECTION VIEWS s7 39 27 ALTERNATE SILL RISER VIEW DRAWN BY: DATE: SECTIONVIEWA-A LIMITED TO+65 BLZ 05/06/16 NO SILL RISER DWG#: REV.: - - NOTES:ITEMS NOT SHOWN FOR CLARITY: 1)INSTALLATION W/NO SILL RISER ALLOWED TO THE FULL DP'S INDICATED ABOVE,IN LOCATIONS WHERE WATER INFILTRATION RESISTANCE CWS-1150 20,24-26,31,55-58,61-62,64-66 IS NOT REQUIRED,SUCH AS BUT NOT LIMITED TO LOCATIONS WHERE AN OVER HANG IS PRESENT THAT IS AS WIDE AS THE WALL IS TALL. SCALE: SHEET 1:3 2 OF 11 PARTS LIST PARTS LIST ITEM PART# DESCRIPTION VENDOR MATERIAL ITEM PART# DESCRIPTION VENDOR MATERIAL C`�rLf2{�(XIU 1 GLASS SEE THIS SHEET 51 S-2058 Screen,3 Track Sill Keymark Alum num WINDOW SYFMS LLLLLLLL���11�11��� 2 K6161 2-Track Sill Vision PVC 52 S-2059 Screen,Snap Cover Keymark Alunanum 1900 SW 44TH AVE. 3 K6163 3-Track Sill Vision PVC 53 S-2070 Screen,Interlock Profile Aluminum OCALA,FLORIDA 34474 4 H-6165 4-Track Sill Vision PVC 54 P-5477 Block,Anti-Lift Lawrence Ion V WW.CWS.CC 5 K6160 2-Track Head/Jamb Vision PVC 55 P-5559 Screw,#14 x 4"PH PN SMS Fastenal Steel 6 1 K6162 3-Track Head/Jamb Vision PVC 56 P-4269 Screw,#8 x 1"PH PN Tek Fastenal Steel ` 8800 PVC 7 K6164 4-Track Head/Jamb Vision PVC 57 P-3556 Screw,98 x 2.5"PH FL Tek Fastenal Steel 8 S-2064 Roller Track Insert Keymark Aluminum 58 P-4962 Screw,98 x 3"PH FL Tek Fastenal 'Steel 25 SLIDING GLASS 9 S-6171 Cover,Sill Track Vision PVC 59 P-5565 Screw,#12 x 1 1/2"PH PN SMS Fastenal Steel FRAME CORNERS DOOR'-IMPACT 10 S-6169 Cover,Interlock Vision PVC 60 P-5566 Screw,#12 x 2 1/2"PH PN SMS Fastenal Steel MECHANICALLY FASTENED 11 S-6172 Cover,External ReinforcementfP-Hook Vision PVC 61 P-3609 Bumper,Panel Stop Parker Seals Rubber 1:8 12 S-6175 Track Filler,Frame Vision PVC 62 P-4291 Panel Stop Housing M&M Nylon 13 H-6166 Panel Stile/Rail Vision PVC 63 P-5479 Foam Block,Open Cell,0.W'x 0.531"x V Lamatek o 14 K6168 Interlock,Snap-On Vision PVC 64 P-5492 Gasket,FrameAssembl ,2-Track Lamatek Butyl 15 K6167 Astragal Vision PVC 65 P-6493 Gasket,Frame Assembly,3-Track Lamatek Butyl m 16 K6170 Glazing Bead,I.G.,1" Vision PVC 66 P-5494 Gasket,Frame Assembly,4-Track Lamatek Butyl 17 K2060 Sill Poser,2,875" Keymark Aluminum 67 P-4659 Dust Plug,1-1/4"x 3"x 0.5" Ultrafab Z 18 K2062 Sill Riser,4.06Z' Keymark Alununum 68 P-4366 Dust Plug,1"x 3"x 1" Ultrafab O 19 P-5517 Panel Guide,Interlock Bear's Metal Aluminum 69 Screen,Spline Team Plastics Rubber rn zW 20 P-5558 Support Channel,Bot Rail,Interlock Sears Metal Aluminum 70 Screen,Cloth p LU 21 P-5511 Cover,Panel Guide,Interlock Lawrence Nylon r' 1"OVERALL 1"OVERALL PANEL CORNERS IL 22 P-5516 Bracket,Fixed Panel Sear's Metal Aluminum ER -'T"TEMPERED a-TEMPERED THERMAL WELD U 23 P-3300 Wts .,0.280"x 0.18T'Back,Fin,Black Ultrafab 16 16 1:8 w 24 P-3438 Backbeddin ,Purfect Glaze"H'Hot Melt Henkel/Sika Silicone 2'AIRSPACE --A"AIRSPACE 25 P-3514 Screw,#10 x 2"Ph Comb Hd Fastenal Steel 16"ANNEALED t6"HEAT STRENGTHENED Z 26 P-3587 Screw,#8 x 1"PH FL TEK-Roller Asrn/Mortise Lock Fastenal Steel LAMINATED LAMINATED 27 P-3752 Hole Plug,0.500"Dia. Progress Plastics Nylon aaaaaaVjDREWf���p 28 P-3789 Handle Set with Thumb Turn Amesburyor Roto F105"PVB INTERLAYER 105"PVB �.�9 P 29 P-3792 Keeper AmesburyINTERLAYER GP;•`,�CENSF.,�Qy 30 P-3793 Multi-Paint Mortise Lack Amesbury1s"ANNEALED V No 58201 :11,'HEAT STRENGTHENED 31 P-4250 Screw,#10 x 2.5"PH PN SMS-Keeper Fastenal Steel 32 P-5287 Tandem Roller Ass ,2.125"Dia Wheel Amesbury STATE OF ,•�: 33 P-5438 Setting Blocks,0.090"x 0.875"x 1.5" Franke Lowe Rubber 4U 34 K1769 Reinforcement,Interlock Keymark Aluminum 16 16 �,.,cv`S• O R lOP���`� 35 K2068 Reinforcement,Astragal Keymark Aluminum 33 `; 8"GLASS BITE 33 ❑ 8"GLASS BITE �,�4SfONA;EN�aa� 36 S-1775 Reinforcement,Lock Stile/Rails Keymark Aluminum 37 K2111 Reinforcement,HD,Interlock Keymark Aluminum 38 S-2071 Reinforcement,External,Interlock Keymark Alununum 24 GLAZE 24 GLAZE HT 7/6/2016 39 S-2069 Frame Insert,Installation Anchors Keymark Aluminum 40 K2063 P-Hook Keymark Aluminum LUCAS A.TURNER,P.E, 01 41 S-2065 P-Hook Adaptor Keymark Aluminum 13 13 FL PE# 1239 JABARA RA AVE.A 42 S-2048 Screen,Astragal Keymark Aluminum NORTH PORT,FL 34288 43 S-2050 Screen,1-Track Head Keymark Aluminum U PH.941-380-1574 44 K2051 Screen,1-Track Jamb Keymark Aluminum nA SHEET DESCRIPTION: 45 S-2052 Screen,1-Track Sill Keymark Aluminum BOM AND GLAZING 46 S-2053 Screen,2-Track Head Keymark Aluminum GLASS TYPE A GLASS TYPE B DETAIL 47 S-2054 Screen,2-Track Jamb Keymark Aluminum DRAWN BY: DATE: 48 S-2055 Screen,2-Track Sill Keymark Aluminum DESIGN PRESSURE BLZ 0 510 6/2 0 1 6 49 S-2056 Screen,3-Track Head Keymark Aluminum GLASS TYPE GATING DWG; REV.: 50 S 2057 Screen,3-Track Jamb Keymark Aluminum A +/-50 PSF CWS-1150 - B +/-65 PSF SCALE: SHEET 1:2 3 OF 11 2. g'—fin 1Z„ 40 8 8 18 Q 9 2 13 15 17 3° WINDOW SYSTQ•IS 3„ 1900 SW 44TH AVE. 1� �E3 F ❑13 ❑❑13 2 a OCALA,FLORIDA 34474 W WW.CWS.CC 2-Track Sill-6161 16" e 6 6° z' ae° 5„ 6, 8800 PVC SLIDING GLASS 0 0 ❑ Q 3 16° DOOR -IMPACT SIII Riser-2060 13 0 I�I ❑ 6063-T6 116 �001-1 a ❑❑❑❑❑'t-50e 32' � Sill Rlser-2062 w 3-Track Sill-6163 Panel Head/Sill/Stile-6166 6063-T6 0 Astragal-6167 P-Hook-2063 108" 6063-T6 } 0 0 0 0 4 „ 38 m 0 113.. � c 0 C � D w npnp�� ��' �„ 2�' �� .. 0❑❑❑ODE: a ❑❑0❑❑❑OLl 32 O `16 2" 1 0.,00-T 39 0 4-Track SIII-6165 I 7— a L I Reinf.,Et-Interlock Reinf.,Frame-2069 -2071 5 8„ 00o 2 I 41 6005-T6 6063-T6 coImo— w .,1„—Lj 14 p 5 Lock Stile-2086 P-Hook Adaptor-2065 6063-T6 1S' 1 B" O z 1 6„ �'I 3° 2 34 36 `,P"On .�', �0❑❑d❑❑❑❑08 32 „ `�jVQ°:GENSFGQy'c 2-Track Head/Jamb-6160 11 No 5ffi01 •:� Cover,Ext Reinf.& d Hookstrip-6172 ro 8 10 �9: STATE OF •4u: Cover,Interlock-6169 Reinf.,Interlock-1769A Reinf.,Lock Stile-1775 '.0.•. e P a4V 6 6005-T6 6005-T6 �i�ES•..........R 1 .•'����• 1� 816 „ 37 �O❑�❑0❑ZS❑0❑�❑08 32" 8 2-�g' 35 1 Z:�—' /2016 3-Track Head/Jamb-6162 9 7/6 Cover,SIII Track-6171 oiler Track Insert-2064 LUCAS A. TURN 10 8' 6063-T5 FL PE#58201 P.E. 1239 JABARA AVE. e" 2& NORTH PORT,FL 34288 7 12 6 O —{ " 16 3 " PH.941 380-1574 SHEET DESCRIPTION: 1 P=❑�❑°❑❑❑°❑❑❑°❑❑❑°8 "32 All1 'IF Reinf.,HD Interlock-2111 EXTRUSIONS 4-Track Head/Jamb-6164 6005-T6 DRAWN BY: DATE: 12 BLZ 05/06/16.- IG Glazing Bead-6170 Reinf.,Astragal-2068 DWG#: Track Filler-6175 6005-T6 REV.: CVVS-1150 - NOTE:ALL EXTRUSIONS ARE RIGID PVC UNLESS OTHERWISE NOTED, SCALE: SHEET 1:2 4 OF 11 Jg 'I 45 fir— 43 12•ff]4 WINDOW SYSTEMS L�J 1 1900 SW 44TH AVE. 16, 1fg" TT OCALA,FLORIDA 34474 16 I WMN.CWS.CC Screen,1-Track Sill-2052 Screen,1-Track Head-2050 O O O 511. 8800 PVC 5 r4 s" I SLIDING GLASS �16" -1 48 46 22 1 DOOR-IMPACT 16" 116 1 I � is — --i� Screen,2-Track Sill-2055 Bracket,Fixed Panel a„ Screen,2-Track Head-2053 P-5516 i6 m „ 51 -� 16' 49 co 16 1„ 11i 6" T_ Screen,3-Track Sill-2058 7b5 ZLU Screen,3-Track Head-2056 54 o w a 1 6 I` 6 �'-12"� 42 2 I III III �I I� III III I fit o44 �853 16 Z 52 �punnuq 1B° 6., p ..1„ 16„ 1„ Z„ Block,Anti-Lift ��py PNC......�Q •. L Screen,Sna Cover-2059 `�a� 1e e G + P-5477,Nylon � V:� F y. Screen,1-Track Jamb-2051 t Screen,Interlock-2097 I No 58201 :�� Screen,Astragal-2048 L ,tU: 4 6• 47 r6„ 1� a —_ •4�SSfON�A/;Ea���` F�24,81, fi II �TJ„—_�III III III III'II IIII I ts" IIIIIIIIII III �2_" 2 1 2 III nIIIIlIII iIIII 7L/6/2�01 6 Screen,2-Track Jamb-2054 LUCAS A.TURN ER,P.E..E. FL PE#58201 1239 JABARA AVE. NORTHPORT,F288 574 4,6 Q 4 2�„ 1 SHEET DESCRIPTION: 1 I EXTRUSIONS 16 r= � I DRAWN BY: DATE:I - Screen,3-Track Jamb-2057 I I II II I IIII BLZ 05/06/2016 DWG#: REV.: CWS-1150 - NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. Panel Guide,Interlock-P-5517 Support Channel,Bot Cover,Interlock-Reint SCALE: SHEET Rail-Interlock-P-5558 P-5511,Nylon 1:2 5 OF 11 ,'T6-• C�rE• 51 i„ g 16„ WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 wNNV.CWS.CC Z„ 8800 PVC q H-2081 I1 Il H-2062 SLIDING GLASS 0 11 1 DOOR-IMPACT °o❑❑�°aD❑ 1a0 ❑ O�j°❑ O o O a o D °❑ o 0❑❑i=iD❑ D �aa D❑❑Lorr—j❑�D❑D�DDD�D�I L 2T Sill w/Riser 3T Sill w/Riser 4T Sill w/Riser o Co z O a 9 � w � logo — O❑ D �❑� ❑ ❑ ❑ �L � ❑ oCD �D D 13 � 2T Sill w/1T Screen 3T Sill w/1 T Screen Z �? No 58201 •'�� z OF 90; STATE OR 0 (� la �0'1ssECG°� rLTL�-----JJII Lam. -J1 n �/ONA�- h�rrrrr�iN•`` -00 7/6/2016 3T Sill w/2T Screen 4T Sill w/IT Screen LUCAS A.TURNER,P.E. FL PE#58201 164- 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: TRACK WIDTHS O O 0 DRAWN BY: DATE: BLZ 05/06/16 o O ❑ O ❑ O o DWG 8: °D❑❑�a❑❑i=is❑D�a❑❑�a� CWS-1150 - SCALE: SHEET 4T Sill w/3T Screen 1:2 6 OF 11 ANCHORS @ 4 P-HOOK C%/ RhLWU 6" 4„ PANEL-T ANCHORS 3"EDGE MAX 6"MAX TYP. TYR.' i• 44 �. �• �'P TYP. I `• I--I I"I� 1 I / �• J ! I ( � / \ I / OF PANEL WINDOW SYSTEMS I ITYP• I I I I I 1 TYP. 1900 SW 44TH AVE. OCALA,FLORIDA 34474 II I WWW.CWS.CO I II 12"MAX.O.C. 21" I II I 8800 PVC MAX I II I SLIDING GLASS LI II I I II I DOOR-IMPACT I II I I II I w I II I o z I II I _ z W II MID-SPAN I O F II OF PANEL I U w II I i o II I zz r, p. �.o o �. �.a �• .`,�tip�nnrrryrr PVIOREby r Ge FIXED PANEL CLIPS ?J�j %:�c� No 5B201 :� NOTES: *CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS. (SEE NEXT SHEET FOR DETAIL) *; 1.INSTALL TWO ANCHORS AT EACH INSTALLATION LOCATION SEE LAYOUT DETAILS ON SHEETS 8&9 EXCEPT FOR 2T SILL&WOOD INSTALLATION LOCATIONS.SEE SPECIAL LOCATIONS AND SPACING FOR 2T SILL -ro ( ) (SHEET 8).INSTALL ONE ANCHOR AT EACH WOOD INSTALLATION LOCATION(CIRCLED). SILL ANCHOR SPACING SAME AS HEAD FOR 3T AND 4T. INSTALL ONE ANCHOR AT EACH LOCATION IN HOOKSTRIP. 0 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 114". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE �''r`.ssfONA11 CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 10. 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST 7/6/2016 BE PROTECTED TO PREVENT REACTION. LUCAS A.TURNER,P.E. FL PE#58201 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM 1239 JABARA AVE. SPECIFIED IN TABLE 1,SHEET 10. NORTH PORT,FL 34288 PH,941-380-1574 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. ANCHOR SCHEDULE AND NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR SOLID CONCRETE,6"FOR CMU MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE: 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. BLZ 05/06/16 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE1,SHEET 10. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. DWGu: REV.: 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: CWS-1150 FMA/AAMA,100(FINWNDOWS),FMA/AAMA200(FLANGEW VD NDOWS), FMANMA250(BOXWNDOWS),FMA/AAMANVDMA300(EXTERIORDOORS) SCALE: SHEET 1:20 7 OF 11 E INTERLOCKSr �//J]((�jjJJ�� [ ASTRAGAL C6�'U2f NILKIU • 6"TYP. 21"O.C.MAX PANEL P-HOOK TYp, WINDOW SYSTEMS 6"TYP. WIDTH 3"TYP. 3"TYP. 1900 SW 44TH AVE. OCALA,FLORIDA 34474 WWW.CWS.CC 0 s"1IYP. I 8800 PVC SLIDING GLASS WOOD SUBSTRATES 211„ DOOR -IMPACT 2TSILL ONLY 2TJAMB TYP.� z�^ TYP. c 6i INTERLOCKS E ASTRAGAL 21"O.C.MAX PANEL P-HOOK 6"TYP, �.{ V TYP.�i WIDTH 4"TYP..--j 4"TYP �_ TYP. I m I z Z Qo Lu o 0 3"TYP. 6"TYR O a ` TYP. � no o 0 0 co w 'TYP.— WOOD SUBSTRATES TYR I4%11 Z "TYP. 3TSILL ONLY 3TJAM6 110, TYP ,��`Pg•PNGENS•ITG�"o. E No 58201 •'��1 E 431 INTERLOCKS *; * :*i �6 TYP. ASTRAGAL A PANEL P-OOKL 21"O.C.MAX �90: STAT6 OF :��L FF----6"TYP. I--4"TYP. 4"TYP. I TYP. �'��cp�F<O R 1 O P•: 6"TYR 4 t' 7/6/2016 TYP LUCAS A.TURNER,P.E. 4 °TYP. FL PE#58201 1239 JABARA AVE. o I o NORTH PORT,FL 34288 0 PH,941-380-1574 SHEET DESCRIPTION: ANCHOR PATTERNS WOOD SUBSTRATES 1�' (JAMB B SILLj ONLY - 4TSILL 4TJAMB TYP TYP. DRAWN BY: DATE:' BLZ 05/06/16r DWG#: REV.: CVVS-1150 - NOTE:(=CENTERLINE OF INTERLOCK OR ASTRAGAL SCALE: SHEET CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS. 1:5 8 OF 11 f' INTERLOCKS ((' • ASTRAGAL HOLE PATTERN P-HOOK WINDOW SYSTEMS FORANTI-LIFT 6"TYP.----{ PANEL BLOCKANCHORS H-4"TYP—I OCA A,FLORIDAAVE. WIDTH OCALA, LOR 34474 WW W.CWS.CC 10 ° 8800 PVC I I I I I SLIDING GLASS °_ _ 1„TMP DOOR-IMPACT �'.TYP. WOOD SUBSTRATES P. 2T HEAD a"rrp ONLY W 4 p INTERLOCKS L HOLEPATTERN ASTRAGAL 6„TYP PANEL FORANTI-LIFT P_HOOK m WIDTH BLOCKANCHORS 1---4"TYP. 4"TYP. Z O U) 0 o uo Z W O O o 4�„ iL P. U -- w W o o 0 p 1„NP O Z 3T HEAD wooD NBSTRATES DREw `�QSrNGENs'•TG��•. A S�t No 58201 � INTERLOCKS PANEL HOLE PATTERN ASTRAGAL '9; STATE OF �6"TYP. WIDTH B�OCKANNCHORs P-HOOK '�O'���•'o( If 4"TYP. 4"TYP. ����`S+SfQORA, o 0 o xZ 7/6/2016 o o T,P, LUCAS A.TURNER,P.E. �- -� FL PE#58201 1239 JABARA AVE. ER 0 o 0 0 NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: O 1°TYp ANCHOR PATTERNS (HEAD) WOOD SUBSTRATES DRAWN BY: DATE: ONLY BLZ 05/06/16 4T HEAD DWG#: REV.: NOTE:(=CENTERLINE OF INTERLOCK ORASTRAGAL SCALE: SHEET •CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS. 1:5 9 OF 11 2 TRACK HEAD ANCHORAGE INTERIOR (('l •� 1/4"MAX WINDOW SYSTEMS MIN.EDGE DIST. SEE LAYOUT ON SHT 9 1900 SW 44TH AVE. SEE TABLE 1 39,FRAME INSERT REQ'D AT OCALA,FLORIDA 34474 ALL FRAME ANCHOR LOCATIONS 39,FRAME INSERT REQ'D V WW.CWS.CC �� AT ALL FRAME ANCHOR a SUBSTRATE LOCATIONS 8800 PVC BY OTHERS MIN.EMBEDMENT SEE TABLET SEE TABLET SLIDING GLASS PERIMETER SEALANT oT SEELAYOUT DOOR-IMPACT BY INSTALLER ON SHT 8 INSIDEAND OUT MAX. SHIM �r MIN EDGE DIST p oU SEE TABLE 1 PERIMETER SEALANT m INTERIOR COMPLIANT WITH AAMA 800 BY INSTALLER INSIDE AND OUT U) Z INSTALLATION ANCHOR 2 SEE TABLE 1 SUBSTRATE BY OTHERS MIN EMBEDMENT L- SEE TABLE 1 SEE TABLE 1 Z 0 LU SEALANT BETWEEN SILL a RISER AND FRAME BY B HORIZONTAL SECTION _ INSTALLER 9 2 TRACK JAMB ANCHORAGE LU PERIMETER SEALANT O BY INSTALLER INSIDE AND OUT 0 Z DO NOT COVER WEEP HOLES MI SEE TABLEENTSUBSTRATE BY OTHERS �`�`Py P 6 E IVS' SEE TABLE 1 :J�;�• F MIN.EDGE DIST. 39.FRAME INSERT REQ'D AT - SEE TABLE 1 ALL FRAME ANCHOR LOCATIONS Zro: �90 STATE OF :�� 9,VERTICAL SECTION 2 TRACK SILL ANCHORAGE PERIMETER SEALANT COMPLIANT WITH AAMA 800 BY INSTALLER INSIDE AND OUT INSTALLATION ANCHOR SEE TABLE 1 7/6/2016 MIN.EDGE DIST. LUCAS A.TURNER,P.E. SEE TABLE 1 FL PE#58201 1239 JABARA AVE. SUBSTRATE BY OTHERS MIN.EMBEDMENT NORTH PORT,FL 34288 TABLE 1:APPROVED INSTALLATION FASTENERS SEE TABLE 1 SEE TABLE 1 PH.941380-1574 SUBSTRATE TYPE IANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. SHEET DESCRIPTION: CONCRETE 2.0 KSI MIN. I1/4"Ii1N TAPCON 1,1R" 4" INSTALLATION DETAILS CONCRETE(2.85 KSI MIN.) 1/4"ELCO ULTRACON 1-3/4" 2.1/2" HOOKSTRIP 2 TRACK 1/4"ITW TAPCON OR 2X MIN.SOUTHERN PINE(G=0.55) 1-38" 7!8" ELCO ULTRACON DRAWN BY: DATE: 2X MIN.SOUTHERN PINE(G-0.55) #12 WOOD SCREW 1-3Z' 718" "MAX.SHIM BLZ 05/06/16 16 GAUGE(0.0 ')MIN. #12-14 HILTI KWIK-FLEX OR ITW FULL THREAD 60 STEEL STUD(33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" 12 DWG#: REV.: 1Z ALUM.(6063•75 MIN.)OR I#12 GRADE 5SELF-TAPPING/ FULL THREAD - - - C HORIZONTAL SECTION CVVS-1150 - 1/8"STEEL(33KSIMIN.) DRILLINGSCREW THRU0.125' 1/2 9HOOKSTRIP SCALE: SHEET HCOKSTRIP OR JAMB FRAME ONLY: 114'ELCO ULTRACON 1-314" 2-1/2" 1:3 10 OF 11 HOLLOW OR GROUP PILLED CMU(A TM C-90 3 TRACK HEAD ANCHORAGE 1/4"MAX 39,FRAME INSERT REQ'D AT INTERIOR MIN.EDGE DIST. SEE LAYOUT ALL FRAME ANCHOR LOCATIONS WINDOW SYSTB'75 ON SHT 9 39,FRAME INSERT REQ'D SEE TABLE 1,SHT 10 �0 AT ALL FRAME ANCHOR 1900 SW 44TH AVE. SUBSTRATE ❑ LOCATIONS OCALA,FLORIDA 34474 BY OTHERS LJ VWW.CWS.CC SEE TABLE 1,SHT 10 MIN.EMBEDMENT SEE TABLE 1,SHT 10 8800 PVC PERIMETER SEALANT n BY INSTALLER El O SLIDING GLASS INSIDE AND OUT SEE LAYOUT 3SHIM 0❑ ONSHTS DOOR-IMPACT INSTALLATION ANCHOR INTERIOR SEE TABLE 1,SHT 10 H SEALANT BETWEEN SILL O RISER AND FRAME BY INSTALLER n PERIMETER SEALANT O O O sa MIN EDGE DIST m BYINSTALLER 0 O O o� SEE TABLE 1 SHT 10 DO Si COVERT �0O❑ ❑❑ ❑❑� N Z PERIMETER SEALANT 0 WEEP HOLES COMPLIANT WITH AAMA 800 MIN.EMBEDMENT BY INSTALLER INSIDE AND OUT > SUBSTRATE SEE TABLE 1,SHT 10 Z W BY OTHERS SUBST TE RA SEE TABLE 1,SHT 10 BY OTHERS MIN EMBEDMENT 0 w 39,FRAME INSERT SEE TABLE 1,SHT 10 SEE TABLE 1 SHT 10 n. MIN.EDGE DIST. SEE LAYOUT ON BHT 8 REQ'D AT ALL FRAME U SEE TABLE 1,SHT 10 F HORIZONTAL SECTION W ANCHOR LOCATIONS 10 3 TRACK JAMB ANCHORAGE p L u VERTICAL SECTION 1/4"MAX Q_OJ 3 TRACK SILL ANCHORAGE INTERIOR 0 Z NSERT MIN.EDGE DIST. 4 TRACK HEADEE LAYOUTGE 39,REQ'D A^TALLSERT 39,FRAME AT ALLLFFRAI REQ'D FRAME ��.` PpACRRV e SEE TABLE I,SHT 10 ON SHT9 ANCHOR LOCATIONS o� LOCATIONS �`p�?r•�OENg'•G���i MIN.EMBEDMENT No 5ffi01 1 �1� y SUBSTRATE SEE TABLE 1,SHT 10 ❑ •• BY OTHERS pg ' SEE TABLE 1,SHT 10 I I LJ '9: STATE OF C ttlt '. A PERIMETER SEALANT �© SEE ON BHT 8 LAYOUT '��4�F••'<O R 1 BY INSTALLER ® "MAX. ❑ '���sS/OfVA1-�p���, INSIDE AND OUT SHIM z�. INSTALLATION ANCHOR INTERIOR �® 7/6/2016 SEE TABLE 1,SHT 10 SEALANT BETWEEN SILL LUCAS A.TURNER,P.E. RISER AND FRAME BY FL PE#58201 INSTALLER �© MIN EDGE DIST 1239 JABARA AVE. PERIMETER SEALANT O 0 0 SEE TABLE 1 SHT 10 NORTH PORT,FL 34288 IN INSTALLER ��� FI� o❑ PH.94TION: 1574 I NSI DE AND OUT U°� SHEET DESCRIPTION: DO NOT COVER WEEP HOLES MIN.EMBEDMENT INSTALLATION DETAILS SUBSTRATE SEE TABLE 1,SHT 10 PERIMETER SEALANT 3&4 TRACK COMPLIANT WITH AAMA 800 BY OTHERS BY INSTALLER INSIDE AND OUT DRAWN BY: DATE: SEE TABLE 1,SHT 10 SUBSTRATE EILZ 05/06/16 39,FRAME INSERT BY OTHERS MIN EMBEDMENT MIN.EDGE DIST. SEE LAYOUT REQ'D AT ALL FRAME SEE TABLE 1 SHT 10 DWG k: REV.: SEE TABLE 1,SHT 10 ON SHT 8 ANCHOR LOCATIONS SEE TABLE 1,SHT 10 CWS-1150 - G HORIZONTAL SECTION E VERTICAL SECTION 10 4TRACK JAMB ANCHORAGE SCALE: SHEET 10 4 TRACK SILL ANCHORAGE 1:3 11 OF 11 Ir�1