Loading...
HomeMy WebLinkAboutEngineering, wind load , sliding glass door I M.A. CORSON & ASSOCIATES Inc. ARCHITECTURE STRUCTURAL DESIGN 1121 S.E. Ocean Blvd., Stuart, Fl. 34996 (772) 223-8227 * Lic. 4AR91665 Date: August 27, 2019 A� BGG c��Fo 7k To: St. Lucie County - Building& Code Regulation Division se Re: Stevenson Residence 3100 N. AIA Unit 904 (middle) Fort Pierce,FL 34949 I It is acceptable to replace existing sliding glass door and for the address listed above j as follows: I 1) S.G.D -The Windoor Inc."8100" Impact Aluminum sliding glass door w/wo reinforcements has a Florida number NOA#17-1219.07. The nominal wind speed is 132 mph and the ultimate wind speed is 170 mph. It has a+60/-100 design pressure and has a small missile "D" approval and HVHZ. The actual building design pressures of address-listed above in Zone 4 is+58:7/-63.7. The building has a type II classification and exposure category "D" for the 6th Edition of the FBC (2017). Worst case scenario has been calculated . I Thank you for your time and consideration. If you have any questions please call. Respectfully, FiLE yl� Mar 7�. Gorson A.I A:,NCARB — President T REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC