Loading...
HomeMy WebLinkAboutProduct Approval (2) Business &-Professi'o'nal Reptatidn', 091 acts Mama I tag to I usermgmmucm I Hat Taps® I Submit surcharge I Stats&Facto I PubHotiona i Contac tds I Bas Site yap It Unk, seamh Praduclk'Apomval Or a USI�R:Public User RECEIVED PW=Angara l Menu:, AwIloWm List:-Application PaWl FL. RS259-P28 AUG 2 9 Application Type Revision Code Version 2017 ST. Lucie County, Permitting Application Status Approved Comments Archived El Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W.Newport Center Drive r% Deerfield Beach,FL 33442 REVIEWED FOP, (954)233-1330 Ext 242 malpert@polyglass.com CODE COMPLIANCE Authorized Signature Maury Alpert ST. LUCIE COUNTY malpert@polyglass.com BOCC Technical Representative Maury Alpert Address/Phone/Emall 1111 W.Newport Center Drive Deerfield Beach,FL 33442 (912)429-8610 MAlpert@polyglass.com Quality Assurance Representative Ariel Lender Address/Phone/Small 1111 W.Newport Center Drive Finch Deerfield Beach,FL 33442 toy o (954)233-1230 ALender0polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nlemlnen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance,Contract EXplration Date 09113/2021 Validated By John W.Knezevich,PE 0 Validation Checidist-Hardcopy Received Certificate of Independence 2018 al CO3 NIEMINEN,odf Referenced Standard and Year(of Standard) Atwid"r Xear ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6164 2011 ASTM D6222 2011 FM 4474 2011 FRSA/TRI April 2012 2012 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method'1 Option D Date Submitted 02/24/2018 Date Validated 01/29%2018 Date Pending FBC Approval 01/30/2018 Date Approved 04/10/2018 Summa of Products FL* Madel,Number or Name Description 5259.1 Polyglass Roof Roofing underiayments Underiayments Limits of Use Installation Instru,ctians Approved for use In HVHZI No FL5259 R28 II 2018 Q1 FINAL ER POLY( IAS I„1NDERLAYMENTS FL5259 Approved for use outside HVHZ.Yes B28,odf Impact Resistant:N/A Verified By:Robert Nleminen PE-59166 Design Pressure.+N/A/-622.5 Created by Independent Third Party:Yes Other.1.)The design pressure In this Evaluation Reports application relates to one particular x„4259 R28 AE 2018 01 FINAL ER POLYGLASS UNDERLAYM.ENTS. FL5259 underlayment system(over concrete deck) P28,ndf for use under foam-on the systems(where Created by Independent Third Party:Yes the underlayment forms part of the load- path).Refer to ER Section 5.6.4 for other systems,other deck types and associated maximum design pressures.2.)Refer to ER Section 5 for other limits of use. .— C ontact Ue;;2601 stair Stone 11-d.Tnlhshassoe Rl 32399 Phone:850-487-1824 The state of Florida is an A&IM employer.Coovriaht 2007-1(113.State of Florida,:Privacy statement;;AoeesslbllM 5tatement::Refund Statpinent Under Florida law,small addresses are public records.If you do not want your a mall address released in response to a pubtic-records request,do act send electronic MOD to this entlty.Instead,contatt the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.wFumuam to Section 455.275(1), Roddy statutes,eHettive Daher 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address Ifthey have one.The email$ provided may he used for official communication with the licensee.However email addresses are pudic record.If you do not wish to supply a personal address,please provide the Department with an email aWress which can be made avalbede to the pudic To determine if you are a fisensee under Chapter 455,FS.,please dtdc,ap_,. pp1a PPr�rogqductApproval Accepts; lo%sl®®IR® Credit Card Safe MEMO etc. Certificate OfMthorkatfon 332455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Polyglass USA,Inc. Evaluation Report P12060.02-09-R24 1111 West Newport Center Drive FL5259-R28 Deerfield Beach,Fl. 33442 Date of Issuance:02124/2009 (954)233-1230 Revision 24:01/24/20ia SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E. for use of the product under the Florida Building Code and Florida Building Code,'Residential Volume. The products described herein have been evaluated for compliance with the Edition (203.7) Florida Building Code sections noted herein. DESCRIPTION: Polyglass;Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility lodation(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADvEmnsEMENT. The Evaluation Report number preceded by the words "NEMOJetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then It shall be done in its entirety. ' INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for Inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages I through 14. Prepared by. sew -.Z Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert Nieminen, Florida RegistraHan No.59166,Florida DCA ANS P.C.on 01/24/201&This does not serve as an electronically xm signed document.' CERTIFICATION OF INDEPENDENCE: 1. NEMO I etc. does not have,.nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc.Is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for . which the evaluation reports are being Issued. 4. Robert Nieminen,P.E.does not have,nor Will acquire,a financial interest in any other entity involved In the approval process of the product. 5. This is a building code evaluation. Neither MEMO I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,Is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMO etc. ROOFING COMPONENT Evxumiom 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments,as produced by Polyglass USA,Inc., have demonstrated compliance with the following sections of the a Edition(2017)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section ' Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3/1507.1.1 Physical Properties ASTM D226 2009 1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical.Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D6264 2011 1507.11.2 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entift Examination Reference Date FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000 PRI(TST5878) Physical Properties PRI01111 04/08/2002 PRI(TST5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI(TST 5978) Physical Properties PUSA-093-02-01 12/23/2002 PRI(TST 5978) Physical Properties PUSA-013-02-02 12/23/2002 PRI(W5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI(TST5878) Physical Properties PUSH-09.8-02-01 07/14/2003 PRi(TST5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI(TST5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI(TST5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI(TST5874) Physical Properties PUSAi 061-02-02 01/28/2008 PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI(TST5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI(TST 5878) Physical Properties PUSA-08&02-01 07/29/2009 MTI(TST 2508) Physical Properties 1X201.17A 04/01/2008 MTI(TST 2508) Physical Properties RX14E8A 01/29/2009 ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD(FST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST6049) Physical Properties 02200.07.03 07/14/2003 ERD(TS'T6049) Wind Uplift P1740.0L07 01/04/2007 ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD(FST 6049) Physical Properties .P13450.08.09 08/13/2009 ERD(TST6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD(TST 6049) Wind Uplift P11030.11.09-2 21430/2009 ERD(TST 6049) Physical Properties P11030.12'.09-3 IIA012009 TST ERD( 6049) Physical Properties P33360.06.10 06/25/2010 ERD(i'Sr6049) Physical Properties P33370.03.11 03/02/2011 ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD(TST 6049) Physical Properties P37300.10.11 10/1942011 NEMO ETC,I.M. Evaluation Report P12060.02.09-R24 Cert wwgfAvModz*Vbn 1#32455. 6TM EDITION(2017)Pic NON-HVHZ EVALUATION FL52594128 Polyglass Roof Underlaymeals,(954)233-1230 Revision 24.,01/24/2018 Page 2 of 14 ONEMOletc. Entity Examination Reference Date ERD(TST 6049) Physical Properties P40390.08.12-1. 08/06/2012 ERD(7Sr 6049) Physical Properties P4039048.12-2 08I0712012 ERD(W 6049) Physical Properties 042420.09.12-3 09/11/2012 ERD(TST 6049) Wind Uplift P39680.03.23 03/04/2013 ERD CM 6049) Physical Properties P45370.04,13 04/26/2013 ERD(M 6049) Wind Uplift P1739.02.07-R2 04/29/2013 ERD(TSr 604.9) Wind Uplift 21757.04.01-1-RI 04/30/2013 ERD(TST 6049) Wind Uplift P41630O8.13 08106/2013 ERD(TST 6049) Wind Uplift P117S1.05.03-RI 11n6/2013 ERD(TST 6049) Wind Uplift P11781.11.03-Rl 11/26/2013 ERD(W 6049) Physical Properties P45270.05.14 05/12/2014 ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD(W 6049) Physical Properties 6020.09.24-2 09/09/2014 ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD(r5T 6049) Physical Properties 6020.09.14-4 09/08/2024 ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD(W 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD CW 6049) Physical Properties PLYG-SC7550.03.15 03/2412015 ERD(TST 6049) Physical Properties P40390.04AS 04103/2015 ERD(TST 6049) Physical Properties P44360.10.14-R1 05/28/2015 ERD CW 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015 ERD(W 6049) V111nd Uplift PLYG-SC8905.05.16-1 05/17/2016 ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 20/22/2016 ERD(I-S7 6049) Physical Properties PLYG-SC13040.12.16 22/27/2016 ERD M7 6049) Physical Properties PLYG-SC1190D.03.27 03/10/2017 ERD CM 6049) Physical Properties PLYG-SC12115.08.17 08/08/2027 ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014 Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 DWV2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule-Hide Cross L% 03/02/2008 Polyglass USA Materials Affidavit Polystick SA Compound 09/1812011 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.10/05/2028 4. PRODUCT DESCRIPTION: Fast, d 4.2.2 Elastabase'Is a fiberglass reinforced,SBS modified bitumen base sheet. 4.3.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet. 4.1.3 Polyglass 62 Base Is a fiberglass-reinforced,asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet. 4.2.1 Polystick MTS or Polystick MTS PLUS Is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,surfaced with polycilefinic film surface;meets FRSA/Ml April 2012. 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an aggregate surface;meets ASTM D1970. 4.2.3 Pollystllck TU Plus Is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a polyester fabric surface,meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC,LLC Evaluation Report P12060.02.09-R24 Ceriffkfft OfAvthadmHon#32455 6m EDITION(2017)FSC NON44VHZ EVALUATION FL5259-R28 PoWlass Roof Underlaymenlis,19SQ Z33-I230 Revision 24:01/2412MB Page 3 of 14 OMEMO letc. 4.2-4 PoWck TU P Is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced,with a granular surface;meets FRSA/TRI April 2012. 4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/M2 polyester fabric surface;meets ASTM D1970 and FRSA/TRI April 2012. 4.2.6 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA APP Cap Sheet(FR) are polyester - reinforced,APP modified bitumen cap sheets,meet FRSA/TRI April 2012. 4.2.7 Polystick Dual Pro"' is a nominal 60-mill thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface,meets ASTM D1970. 4.2.8 PoIWkk rile Pro' is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970 and FRSA/TRI April 2012, 4.2.9 Polystick MUX is a nominal 54-mil thick-dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polypropylene film surface;meets AC188 and physical requirements of ASTM D1970(See Section 5.8). Miichaltoi eld"iiqidloi., 4.3.1 Elastoflex 6 TU is a polyester reinforced, modified bitumen the underlayment composed of a sand-surfaced SBS modified bitumen back-side and granule-surfaced APP modified bitumen top-side. Elastaftex 6 TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M)in the 'Single Ply System"from FRSA/TRI April 2012 (04-12)beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened or adhered file roof systems. 4.3.2 Bastoflex SIS 6 and Elastoflex S6 6 FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164. Elastoflex S6 6 and Elastoflex S6 6 FR are for use as an alternate to"Mineral Surfate Roll Roofing" (ASTM D6380, Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened the roof systems. Elastaftex S6 6 is for use as an alternate to Hot Asphalt applied"Cap Sheer in the'Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems. Elastaflex SIS G FR Is for use as an alternate to Hot Asphalt applied "Cap Sheer in the 'Two Ply System"from FRSAfTR1 April 2012 (0412) beneath mechanically fastened tile roof systems. 4.3.3 -Polyflex: G and Polyflex 6 FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied'Cap Sheer in the"Two Ply' System"from FRSA/TRI April 2012 (0442)beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat Applied"Cap Sheer in the"Two Ply System"from FRSA/TRI April 2012(0412) beneath mechanically fastened tile roof systems. S. Llmffmow: 5.1 This is a building code evaluation. Neither MEMO I etc. nor Robert Nierninen, P.E.are, In any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, Is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use In the HVHZ. 5.3 Fire Classification Is not part of this Evaluation Report, refer to current Approved Roofing Materials Directory for fire ratings of this product. 14 Polyglass Roof Underlayments may be used with any prepared roof cover where the product Is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO ETC,LLQ Evaluation Report P12060.02.0"24 QWftcute OfAuthadMilan#32455 e"EwnoN(2033)FBC NON-liVHZ EVAWATION F15239-R28 PotVglass Roof Underiaymentr,(054)233-1230 Revision 24:01/24/2018 Page 4 of 14 SNEMOjeft. 55 Allowable Roof Covers: .. .., :, ...r..•:••;ak.• :. �+�•..•.;.•. '�7,11WW��:•:�i15F�OVER(1'(�tTIQNS, riti�. ..ts•' .. Underlayment Asphalt Shingles Nall-On Tile •Foam-On Tile Metal Wood Shakes Slate &Shingles Elastobase Yes Yes Yes Yes Yes Yes (Base in2-plysptem) {BawSheet In2-plysystemj Elastobase Py� Yes Yes Yes Yes Yes (ease Sheet in 2-Pty systemsst) (aSheet in 2-ply system] Powass 62 Base No Yes Yes No No No (Base Sheetin2-piysystem) (8aw3heetln2-0ysyaem) Polygla5s APP Base No Yes Yes No No No (am sheet in 2-plysymm) (Ease sheet to 2-ply system) Polystick MTS or MTS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes PolystickTU P No Yes Yes(See 55.1) No No No Polystick TU Plus Yes Yes Yes(See 5.5.1) Yes Yes Yes PolystickTU Max No Yes- Yes(See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick7ilePro Yes Yes Yes(See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6 G Yes Yes Yes(See 5.5.1) No Yes Yes ElastoffexSSG FR Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes(See 55-1) No Yes Yes Polyflex G Yes Yes Yes(See 55.1) No Yes Yes Polyflex GFR - Yes Yes No No Yes Yes PolyflexSAPorSAPFR I Yes Yes Yes(SeeSal) No Yes Yes Mule-Hide SA-APP Cap Sheet Yes Yes Yes(See 55.1) No Yes yes or SA-APP Cap Sheet(FR) 5.5.1 "Foam-On Tile"is limited to use of the following Approved the adhesives/underlayment combinations. TABU=1d:At�tHM1►A [f�litEpDjESLtiE/llp)DEtt►1(Mt CO�Iivf�TitTNsi:` .M Adhesive . Florida Product Approval Undertayments DAP Foam Touch'n Sea(StonnBond Roof FL14506 Polystick TU Plus,Polystick TU Max Tile Adhesive Dow TileBond' FL22525 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro, ICP Adhesives Polyseti°AH-160 FL6332 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro, ICP Adhesives PolysetO RTA-1 FL6276 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval far Overturning Moment Resistance Performance NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Cert/ji—afAuthartraWn0324M 61 FmmoN(2t117)Fac NON-HVHZEVALUAT(oN _ _ FL5259-1128 PoWlass Roof Underiayme ts)(954)233-1230 Revision 24:01/24/2018 Page 5 of 14 ONEMO etc. 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Polystick(all variations),Dual Pro,Tile Pro,Polyflex SAP or SAP FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)self-adhered to: ➢ New untreated plywood;ASTM D41 primed new untreated plywood;Existing plywood;ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D42 primed structural concrete; Huber Engineered Woods `ZIP System" Panels (designed and installed to meet wind loads for project). Note:Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: D ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch-applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond-to-Insulation: Polystick(all variations),Polyflex SAP or SAP FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered to: ➢ ASTM C1289, Type 11, Class 1 polyisotyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard;Dens Deck Prime,or SECUROCK Gypsum-Fiber Roof Board. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. Polyflex G or Polyflex G FR torch-applied to: A ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on the systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Laver: Polystick(all variations), Polyflex SAP or SAP FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)Dual Pro or Tile Pro self-adhered to: ➢ ASTM D226,Type i or II felt;Elastobase;.Elastobase P or Mule-Hide Nail Base. Elastoflex G TU,Elastoflex S6 G or Elastaflex S6 G FR in hot asphalt to: ➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P,Mule-Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch-applied to: ➢ Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04-12),Appendix A,Table 1,or listed in Section 5.6.4 herein,or as tested in accordance with FBC Section 1504.3.1. NEMO ETC,U.C. Evaluation Report P12050.02.09-R24 FL5&Ajff=te ofAutharhatbn#32455 6m EDITION(2017)FBC NON-HVHZ EVALUATION 01/24/2018 Polyglass Roof Underlayments,(954)233-1230 Revision 24:01/24/2018 Page 6 of 24 ONEMO I etc. 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Avallcations: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed In FRSA/TRI April 2012(04-12)and are used in foam-on file applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure- divided by 2(the 2 to I margin of safety per FBC 1504.9 has already been applied).Refer to FRSA/TRI April 2012(04-' 12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-90 psf. Deck: Min.I5/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer None ease Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #2 Maximum Design Pressure=-97.5 psf Deck: Min.15132-inch plywood to meet project requirements to satisfaction ofAuthoritv Having Jurisdiction. Primer: P(3100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed Within the selvedge-edge side la using .x IX"ring shank nails through 32 ga,1-5/r diameter tin caps spaced 12-Inch o.c. laps sing 12 ga #3 MpArrium Design Pressure=-105 ad; Deck: Min.15132-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 - Base Ply- (Optional)Polystick MTS or Polystick MTS PWS,self-adhered. Underlayment:yment Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA,-APP cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1Y."ring shank nails through 32 ga,1-5/8"diameter tin caps spaced 12-Inch oc. #4 Maximum Design Pressure=-135 ad, Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer. (Optional)PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PWS,self-adhered. Joints: Min.4-inch wide strips of Elastallex SAW over all plywood joints. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA APP Cap Sheet(FR),self-adhered. #5 —Maximum Design Pressure=-315 Vsf. Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply. (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Tile Pro,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #6 Maximum Design Pressure=-622.5 usf: Deck- Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer. PG100 or ASTM D41 Underlayment:Elastuflex G TU or Elastollex SS G,applied In full mopping of hot asphalt or Polyflex G,torch-applied. #7 Maximum Design Pressure=-30.0 psf*-. Deck. Mim 15/32-inch 0S8 to meet project requirements to satisfaction of Authority HavingJurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1125-Inch long x 1;.Inch head diameter round metal cap nails Spacing: 64nch o.r—at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. MEMO ETC,UC. Evaluation Report P12060.07-09-R24 Ceriftate ofAtitharhutibn#32455 6TM EDITION(2017)FBC NON-HVHZ EVALUATION F1.520-1128 Polvglass Roof Underlayments,(954)233-1230 Revision 24:01124/2018 Page 7 of 14 OMEMO etc. #8 Maximum Deslan Pressure=-37.5 Pd-: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch mc.at the 3-inch wide side laps and 6-inch o.c.,at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #9 Maximum Design Pressure=-37.5 psf*: Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o:c at the 3-Inch wide side laps and 22-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elasfoflex G TU or Elastoflex S6 G.applied in full mopping of hot asphalt #10 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)layer ASTM D226,Type it felt Fasteners: 11 ga.x 1.25inch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt #11 Maximum Design Pressure=-45 psf*: Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. . Base Sheet: Two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-S/8-inch diameter tin caps Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c,at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTs or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Pius,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt #12 Maximum Design Pressure=-45 asf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MARX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide slde laps and 184nch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #13 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-Inch o.c.at the 2-inch wide side laps and 12-Inch o.c,at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied. #14 Maximum Design Pressure=-52S psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 34nch wide side laps and 64nch o.c.at four(4)equally spaced staggered center rows. Base Ply. (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. NEMO ETC,LLC. Evaluation Report P12b60.02.09-R24 certytaote cfAuthorkatkm#32455- 6TM EDITION(2017)FBC NON-HVHZ EVALLiATION FL5259-1128 Polygiass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 8 of 14 ALA #15 Maximum Design Pressure=-52.5 Dsf: O& NEMICIletc. Deck: Min.25/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface fortorch-applied rap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch ox-at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #16 Maximum Design Pressure=-60 Dsf: Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having.lurlsdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/84nch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center.rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied. #17 Maximum Din Pressure=-60 Dsf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly--film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip.with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c.at the 4-Inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #18 Maximum Design pressure=-67.5 Dsf• Deck: Min.95/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base[requires use of torch-applied underlayment) Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing 8-inch o.c.at the 44nch wide side laps and 8-inch o.c at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Pofyflex G,torch- applied. #19 Maximum Design Pressure=-75 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base jrequfres use of torch-applied underinyr'nent) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrlp#14 with OMG Flat Bottom Plates (AccuTrac), Thdast HD with Trufast 34nch Insulation Plates or Simplex MARX Cap Fasteners Spacing: 104nch o.c.at the 4-inch wide side laps and 1C4nch o c,at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Poiyflex G,torch- applied. #20 Maximum Design Pressure=-9D Dsf: Deck: Min.15/32-inch.plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch at at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastaflex G TU or Elastoflex S6 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied. #21 Maximum Design Pressure=-90 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having J urlsdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG 914 Heavy Duty,with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c,at the 4-Inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment.Elastoflex G TU or Elastoflex S6 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied. #22 Maximum Design Pressure=90 Dsf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 IIP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-Inch o.c.at three(3)equally spaced staggered center rows. Underiayment:Elastoflex G TU or Elastoflex S6 G,applied In full mopping of hot asphalt. NEW ETA LLQ Evaluation Report PIM60.02.09-R24 Certiifkate ofAuftrimilon#32455 6r"EDITION(2017)F8C NON-HUFIZ EVALUATION FL5259-RZB Palygiass Roof Underlayments,(454)2331230 Revision 24:01j2412018 Page 9 of 14 #23 Maximum Design Pressure=-90 DsF NNEW' Jetc Deck: r Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polygiass G2 Base or Polyglass APP Base{requires use of torch-applied underloyment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roalgrip#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3dnch Insulation Plates or Simplex MAXX Cap Fasteners Spacing. 9-inch o.c.at the 4-Inch wide side laps and 9-Inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastofiex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch- applied. #24 Maximum Design Pressure=-97.5-pd: Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurlsdiction. Base Sheet: Elastobase or Mule-Hide Mail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-Inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c at the 4-rich wide side laps and flinch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP,Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self adhered: #25 Maximum Design Pressure=-105 psf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applled cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-Inch o.c.at the 2-Inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastaflex 56 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied. #26 Maximum Design Pressure=-112.5 Dsfi Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-Inch x 3/84nch head diameter annular ring shank roofing nails at 15/8 incl diameter tin caps Spacing: 6-Inch o.c,at the 44nch wide side laps and 64nch o.c.at four(4)equally spaced staggered center rows. Primer: PG300 or ASTM D41 primer at all tin-caps Base Ply: Polystick MTS or Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #27 Maximum Design Pressure=-120 Dsf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-Inch o.c.at the 44nch wide side laps and 6-Inch o c at five(5)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #28 Maximum Design Pressure=-120 asf: Deck: Min.33/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP orTrufast#14 HD with Trufast 3"Metal Insulation Plates Spacing. 6-inch o.c.at the 44nch wide side laps and 6-inch c.c.at five(5)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,appiled in full mopping of hot asphalt. 5.6.4.1 All other-direct-deck, adhered Polyglass underlayment systems beneath foam-on file systems carry a Maximum Design Pressure of-45 psf. NEMO ETC,LLC. EvalUation Report P12060.02.09-R24 crdf cWt ofAutharkWan 1132455 EDITION(2017)F8C NON-HVHX EVALUATION FL5259-R28 Polyglass Raaf underlayments;(954)233-1230 Revision 24:01/24/2018 Page 10 of 14 ONEMO etc. 5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-22),Appendix A,Table IA. Alternatively,*the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined In accordance with FBC 1609. In this case,Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDI,FM Loss Prevention Data Sheet 2-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 2-29(January 2026)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobasa, Elastobase P, Polyglass G2 Base or POlygl2ss APP Base shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe or Polystick MUX shall not be left exposed for longer than 90-days after Installation. Polystick MTS, MTS PLUS,TU P,TU Plus,TU Max,Dual Pro,Tile Pro or Elastoflex 6 TU shall not be left exposed for longer than 180-days after installation. Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering Is to be adhesive-set tile,in which case the maximum exposure Is 30 days. Elastoflex S6 G or Elastoflex S6 6 FR or Polyflex G or Polyflex 6 FR does not have an exposure limitation,unless the prepared roof covering Is to be adhesive-set tile (Elastoflex S6 IS or Polyflex G only), In which case the maximum exposure is 180 days. 5.8 Polystick MUX has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt In a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller,as set forth In Section,4.3,Note 1 of ASTM 01970-15,should be established as to slip resistance. 5.9 life Slippage Limitations(FRSA/TR1 Aaril 2012(04-12)): When loading roof files on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be.exceeded by using battens during loading of the roof tiles. iti3 PAAPI� -q 'or mc,n k-e qLL ' Underlayment Tile Profile Staging Method Maximum Slope Elastoflex G TU Flat 10-tile stack 7:12 Lugged 8-tile stack(6 over 2) 6:12 Elastoflex SS G or SG 6 FR Flat or Lugged 6-tile stack(4 over 2) 4:22 Polystick MTS or MTS PLUS Flat 6-tile stack(4 over 2) 5:12 Lugged 6-tile stack(4 over 2) 4*22 Polystick Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:22 Flat 6-tile stack(4 over 2)or 3.0-tile stack 7:12 Polystick TU Max Lugged 6-tiFe suck(4 over 2) 7:22 Lunged 10-tile stack 6112 Polystick TU P Flat 6-tile stack(4 over 2) 6:12 Lugged 6-tile stack(4 over 2) 4:22 Polystick TU Plus Hat or Lugged 6-tile stack(4 over 2) _7:12- - Flat or Lugged 10-tile stack 6.12 Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4d2 Polyflex SA P or SA P FR Rat or Lugged 6-tile stack(4 over 2) 4.12 NEMO ETC,LLC. Evaluation Report P=60.02.09-R24 ONW-W ofAuthorkation 032455 6TM EDITION(zw)Foc NON-mvmzEvALuAnoN FLS259-R28 Polyglass Roof Underlaymenur,(954)233-1230 Revision 24:0IA4/2018 Page 11 of 14 OMEMO etc. 6. INSTALLATION: 6.1 Polyglass Roof Underlayments'shall.be installed in accordance with Polyglass published Installation requirements subjectto the Limitations setforth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6 �-Fottiq.M r-M .0ldpiNal Raili- : 6.3.1 Non-Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226,Type 11 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase,Elastobase P or Mule-Hide Nail Base may be covered with a layer of PoWck,Polyflex SAP,Polyflex SA P FR, Mule-Hide SA APP Cap Sheet or SA-APP Cap Sheet (FR), self-adhered, Elastaflex 6 TU, Elastoflex SG 6 or Elastoflex S6 6 FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are those associated with the top-layer underlayment,as set forth in Table 1, 6.3.2 Tile Applications: Elastobase,Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the"I"Wo Ply System"from FRSA/TRI April 2012(04-12). Reference Is made to Table 1 and Section 5.6.4 herein,coupled with FRSA/TRI April 2012(0412)Installation Manual. " TU" '*o-r.0Qii^.X Polys - I-WS JR. Two,"Ping). Mq*$--'baA T.;Ept --mun P0. .6.4 . ., W . -.Cq "prp 1".ljqk�WA,1PP,Ca 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D2970(except Polystick TU P)underlayment In FBC Table 1507.2.1 for the type of prepared roof covering to be installed. 6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers; All self-adhering materials,with the exception of Polystick TU Plus, Polyflex SAP.or SAP FR and Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule- Hide.back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter metal disk or Simplex-type metal cap nail,at a minimum rate of 22"o.c. Polystick TU Plus should be back- nailed using the above noted fasteners and spacing, In area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back-nailed: All seal-lap seams (selvage laps) must be firmly railed with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). view of ovejap Seam of Dual Pro and Tile Pro All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus;SO Premium Modified Wet/DrV Cement or Polyglass PGSOO Modified Cement applied in between the application of the lap. Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys, or exposed roof to wall details NEMO ETC,LLC. Evaluation Report P12060.02.09-1124 certljkM afAutharimtIon 032455 6TM EDITION(2017)FBC NC"VHZ EVALUATION FLS239-R28 polyglass Roof UnderlaVments;(956)233-1230 Revision 24:01/24/2018 Page 12 of 14 ONEMO!etc. Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the area in need of repair,followed by a minimum 6 x 6 inch patch of the Polyst)ck material of like kind, set and hand rolled In place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 404b weighted-roller or,on steep slopes,use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches,laps(min.28 Ib roller)or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 Tile Applications(not allowed for Polystick Dual Pro /lt Xe or Polystick-MU-M: Reference is made to FR5A%TRI April 2012 (0412) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened file roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s),Base Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table L For adhesive-set tile applications,refer to Section 5.6.4 herein. 6.4.4 Two(2)Ply Underlayment Systems: Polystick MTS or MTS PLUS followed by Polystick MTS,MTS PLUS,TU P,TU Plus,TU Max,Tile Pro,MUX or PobAex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P,TU Plus,TU Max,Tile Pro or Polyflex SAP is allowable for use under foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. ;.t. F' "a ;.S �. -so -two 6.5.1 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be installed In compliance with current Polyglass published Installation requirements. For use in the applications: ✓ Elastoflex G TU is for use as an alternate to"Mineral Surface Roil Roofing"(ASTM D6380,Class M)in the"Single Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened the roof systems or the Hot Asphalt applied"Cap Sheet"in the'Two Ply System"from FRSA/TR1 April 2012(04-12)beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened the roof systems or the Hot Asphalt applied"Cap Sheet"in the'Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened the roof systems or the Hot Asphalt applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems. 6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt-applied to the substrates noted In Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. - �i_4.! •iJ.�P 1'••..i!F, :N' i.lJi:::•.,1.1?.- •C:}�. - rt.. .(•^::...,r-.-,.- - 6.6.1 Polyflex G or Polyflex 6 FR shall be installed in compliance with current Polyglass published installation requirements. For use in the applications: ✓ Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet"in the"Two Pty System"from FRSA/TRI April 2012(0412)beneath mechanically fastened or adhered file roof systems(Base Sheet Limited per 5.6.3). ✓ Polyflex G FR is for use as an alternate to the Heat Applied"Cap Sheer in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems(Base Sheet Limited per 5.6.3). NEMO ETC,LLC- Evaluation Report P12060.0249-R24 Certificate ofAuthaftatbn X32455 6TM EOMON(7037)FBC NON-HVH2 EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 23 of 14 OMEMO I etc. 6.6.2 Polyflex G or Polyflex G FR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide,off-set minimum 3 feet from course to course. Side and end laps shall be fully heat-welded and inspected to ensure minimum 3/84nch flow of modified compound beyond the lap edge. 6J Tile Stal=.im 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein,and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter-battens,as required by the tile manufacturer and FRSA/TRI April 2012(0412)must be used on all.roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail- boards,to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-eight(48)hours. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFAcrURiNG PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C.61620-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. :Plarif: " So'p'cifiatiionr,a ::,:.: •=:::: ••'t` ', ;Product s Fernley,NV,Hazleton,PA&Winter Haven,FL ASTM D1970 Polystick MU-X Hazleton,PA M-D 13-0004• Elestoflex G TU ASTM D2970 Polystick IR-Xe Hazleton,PA&Winter Haven,FL ASTM D1970&FRSA/TRI April 2012 Polystick TU Plus ASTM D1970&FRSA/TRI April 2012 Polystick TU Max Tuscaloosa,AL ASTM D4601,Type II Polyglass G2 Base ASTM D226(physicals) Elastobase,Elastobase P ASTM D6509 Polyglass APP Base FRSA/TRI April 2012 Polystick MTS,Polystick MTS PLUS FRSA/TRI April 2012 Polystick TU P Winter Haven,FL FRSAtM April 2012 Polyflex SAP,Polyflex SA P FR ASTM D1970 Poiystick Dual Pro ASTM D1970&FRSA/TRI April 2012 Polystick Tile Pro ASTM D6164 Elastoflex S6,Elastoflex S6 G FR ASTM D6222 Polyflex G,Pal lex G FR 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3405;k.chancellor@us.ul.com -END OF EVALUATION REPORT- NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 cert(fkate ofAuthor&atian#32455 6TM EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underiaymentg(954)233-1230 Revision 24:01/24/2018 Page 14 of 14