Loading...
HomeMy WebLinkAboutProject information, factor rating I , RECEIVED - _. St. Lucie County ` Building Department A U G 9 I; - ATTENTIONST. Lucie County, PcrmiCt;nc� The 5t Edition of the Florida Energy Code went into effect June 30, 2015. In accordance with the new Florida Energy Code,the following changes and requirements for new construction and ,� replacement windows, doors and skylights are listed below. Mobile homes are not required to meet the requirements of the 50' Edithion of the Flodida Energy Code • Windows and Doors will be required to meet the U=Factor, Solar Heat Gain Coefficient (SHGC) required in section 402 of the 5�1 Edition of the Florida Energy Code for climate zone 2. Opaque doors up to 24 sq. foot are exempt Per R402.3.4 of the 5t'Edition of the Florida Energy Code. All labels showing manufactures U- Factor Rating and Solar Heat Gain Coefficient will be required to be:left on windows and doors until window/door inspection is completed. TABLE R402.1.1 INSULATION AND FENESTRATION RE UIREMENTS BY COMPONATE CLIMATE FENESTRATION SKYLIGHT GLAZED CE ING WOOD MASS FLOOR BASEMENT SLAB d I CRAWL ZONES U-FACTOR b,j U-FACTOR FENESTRATION R FRAME WALL i R- WALL c R SPACE b SHGC b VALUE WALL R VALUE R VALUE VALUE I WALL. R VALUE VALUE &DEPTH R- VALUE 1 0.50 0.75 1 0.25 30 13 3/4 13 1 0 0 ! 0 2 0.40 0.65 0.25 38 13 1 4/6 13 0 1 0 0 3 0.35 0.55 0.25 38 20 OR 1 8/13 5/13 5/13 0 5/13 13+5 b.The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. Exception: Skylights may be excluded from glazed Fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30. j.,For impact rated fenestration complying with Section 8301.2.1.2 of the Florida Building Code,Residentialior Section 1609.1.2 of the Florida Building Code,Building the maximum U-factor shall be 0.75 in Climate Zone 1 and 0.65 in Climate Zone 2. I RECEIVED NFRC FENESTRATION MAIN UFAGURER CERTI I CATE ST. hucle County, Permlttlng NFRC Manufacturer: Contact: ` 0 1)i d C t-*N n = Phone: g�[ -(� -013 f 1 71 Address: C(CoCo S CDCO e,- l �(`Lll t.. (1 n„p- G City: r`excein Q en rk, State: E t Zip Code: R U S 7 Project/Location Information(Name Optional): Address: City: State: Zip Code: I ENERGY PERFORMANCE RATINGS ENERGY PERFORMANCE RATINGS U-Factor(U.S./I-P) Solar Heat Gain Coefficient U-Factor(U.S./I-P) Solar Heat Gain Coefficient ,I ADDITIONAL PERFORMANCE RATINGS ADDITIONAL PERFORMANCE RATINGS Visual Transmittance Air Leakage (U.S./1-P) Visual Transmittance Air Leakage (U.S./I-P) i .i Condensation Resistance Condensation Resistance i t ENERGY PERFORMANCE RATINGS ENERGY PERFORMANCE RATINGS U-Factor(U.S./I-P) Solar.Heat Gain Coefficient U-Factor(U.S./I-P) Solar Heat Gain Coefficient .! ADDITIONAL PERFORMANCE RATINGS ADDITIONAL PERFORMANCE RATINGS Visual Transmittance Air Leakage (U.S./I-P) Visual Transmittance Air Leakage (U.S./I-P) Condensation Resistance Condensation Resistance Manufacturer stipulates that these ratings conform to applicable NFRC procedures for determining whole product performance.NFRC ratings are determined for a fixed set of environmental conditions and specific product size.NFRC does not recommend any product and does not warrant the suitability of any product for any specific use.Consult Manufacturees literature for other product performance information.ww-w.nfn:.om Use as many sheets as necessary for each project/location Sheet of ,I i I ' I