Loading...
HomeMy WebLinkAboutDesign Pressure Calcs ti -- rOuth {. l., NewS ' "+. ` WIN DOW sOLUTIOws 2526 Okeechobee Blvd,West Palm Beach,FL 33409 561-712-9000•CRC1330822 Property Information Building Information Owner: WALTER&VERONIKA SWORDS Wind Zone: 170 MPH. Address: 5502 SILVER OAK DRIVE Exposure Category: C FT PIERCE,FL 34982 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 17 48 7 37.8 -41 A 2 Int 51 48 7 36.5 -39,.7 3 Int 17 48 7 37.8 -41,:0 4 Int 72 48 7 35.6 -38:8 5 Int 35 60.50 7 36.8 -40'.1 6 Int 35 60.50 7 36.8 -401.1 7 Int 109.25 60.50 7 34.1 -37.3 8 Int 72.25 48.25 7 35.6 -38.8 9 Int 72.25 48.25 7 35.6 -38.8 10 Int 72.25 48.25 7 35.6 -38.8 11 Int 72.25 48.25 7 35.6 -38.8 12 Int 109.25 60.50 7 34.1 -37.3 13 Int 51 60.50 7 35.9 -39.1 14 Int 36 80 7 36.1 -39.3 15 Int 36 80 7 36.1 -39.3 RECEIVED AUG 2 9 ''±9 ST, Lucie County, Permitting i FILE %ivy Prepared in accordancl with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of'1 i