HomeMy WebLinkAboutBUILDING PERMITAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date:
•
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
PERMIT TYPE: PLUMBING
PROPOSED IMPROVEMENT LOCATION:
Permit Number:
Building Permit Application
Commercial Residential X
Address: 7146 Hawks View TRL Saint Lucie West, FL 34986
Property Tax ID #: 3322-615-0010-000-9
Site Plan Name:
Project Name: WATER HEATER
� ,1��77��iT:TI�Li ►I�I734�N : .
50- GALLON ELECTRIC WATER HEATER REPLACEMENT
CONSTRUCTION INFORMATION:
Additional work to be performed under this permit— check all that apply:
Lot No.
Block No.
_Mechanical _ Gas Tank —Gas Piping _ Shutters _ Windows/Doors
_ Electric Plumbing _ Sprinklers _ Generator _ Roof Pitch
Total Sq. Ft of Construction:
Cost of Construction: $ 1,382.00
Sq. Ft. of First Floor:
Utilities: _Sewer _Septic Building Height:
OWNER/LESSEE:
CONTRACTOR:
Name Thomas J Demaro
Name: RICHARD BASSOFF
Address: 7146 Hawks View TRL
Company: ADMIRAL PLUMBING SERVICES, LLC
City: Saint Lucie West FL State: _
Zip Code: 34986 Fax:
Phone No. 720-394-5820
Address: 2895 JUPITER PARK DR STE 700
City: JUPITER State: FL
Zip Code: 33458 Fax:
Phone No 561-746-1180
E-Mail: demaro65@gmail.com
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
E-Mail PERTMITTING@THEADMIRALPLUMBER.COM
State or County License CFC-1426115
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: _ Not Applicable
MORTGAGE COMPANY: _ Not Applicable
Name:
Name:
Address:
Address:
City: State:
City: State:
Zip: Phone
Zip: Phone:
FEE SIMPLE TITLE HOLDER: _ Not Applicable
BONDING COMPANY: _Not Applicable
Name:
Name:
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR ER OR AN ATTORNEY BEFORE RECORDING YOUR41160TICE OF COMMENCEMENT."
Signature of OvAerf Lessee/Contract r a ge for Owner
Signature of on ractor/Licen a Hol r
STATE OF FLORIDA
STATE OF FLORIDA
COUNTY OF PALM BEACH
COUNTY OF PALMBEACH
The forgoing instrument was acknowledged before me
The forgoing instrument was acknowledged before me
this 30 day of AUGUST 20_ by
this 30 day of AUGUST 20 by
RICHARD BASSOFF
RICHARD BASSOFF
Name of person making statement.
Name of person making statement.
Personally Known x OR Produced Identification
Personally Known x OR
Type of Identification NotaryPUDGCStateolFloridaFlo
Produced u State
My Commlaebn cG 233150
�p Expire O6/28/2022
Type ofldentification ��� Notary Public State ofFlonda
Produced Jacqueline Georgescu
Ex ir"Cawi06/ aion 22 233150
�« � Expirea 0&2812022
OA
nature Notary Public- State of Florida)
ary Public- State of Florida )
ignature orNin
2(S'
ommission No. �233160 (Seal)
Commission G m 15o (Seal)
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
RECEIVED
DATE
COMPLETED
ev.
h ' PLUMBING SERVICES
A Service Experts Company
Billing Address
Tom Demaro
7146 Hawks View Trail
Port St. Lucie, FL 34986 USA
Admiral Plumbing Services
A Service Experts Company
2895 Jupiter Park DR #700
Jupiter, FL 33458
561-746-1180
License: CFC 1426115
Description of Work
Invoice 25264604
Invoice Date 8/22/2019
Terms COD
Completed Date 8/22/2019
Customer PO
Job Address
Tom Demaro
7146 Hawks View Trail
Port St. Lucie, FL 34986 USA
Supplied and installed a Rheem 50 gallon electric water heater in garage wit expansion tank, ball valve, and permit.
Task# Description Quantity Your Price Your Total
T42610 STANDARD 50 GALLON ELECTRIC WATER HEATER 1.00 $925.00 $925.00
A14860 WATER EXPANSION TANK (TANK ONLY) 1.00 $175.00 $175.00
A13210 3/4" BALL VALVE - CXC 1.00 $57.00 $57.00
Permit WH WATER HEATER PERMIT 1.00 $225.00 $225.00
Paid On Type Memo Amount
8/22/2019 Visa $1,382.00
Sub -Total $1,382.00
Tax $0.00
Total Due $1,382.00
Payment $1,382.00
Balance Due $0.00
I hereby agree to have Admiral Plumbing Services A Service Experts Company complete the work described for the proposed price
regardless of the time it takes to complete the work.
8/22/2019
1 hereby acknowledge the satisfactory completion of the above described work.
8/22/2019
1 authorize Admiral Plumbing Services A Service Experts Company to charge the agreed amount to my credit card provided herein. I
agree that I will pay for this purchase in accordance with the issuing bank cardholder agreement.
8/22/2019
a
The new degree of comfort'
Professional Classic° electric water heaters are
engineered for longer life - resistored heating
elements and premium grade anode rod
Efficiency
•.92-.93UEF
• Isolated tank design reduces
conductive heat loss
• Resistored copper upper element and
resistored Lifeguard" stainless steel
lower element to prolong anode rod
and tank life
�3
Performance
• FHR: 43 - 67 gallons, based on gallon
capacity
• Recovery: 21 GPH at a 900 F rise
System Sentinel
(Available on selected models)
• Exclusive diagnostic system with
glowing LEDs that verify heating
element operation. LEDs pin point the
exact location of functioning or non-
functioning heating elements
Longer Life
• Premium grade anode rod provides
long-lasting tank protection
Features
• Electric junction box located above
heating elements for easy installation
• Over -temperature protector cuts
off power in excess temperature
situations
• Automatic thermostat keeps water at
desired temperature
Plus...
• EverKleen'" self cleaning device fights
harmful sediment build-up with a
high -velocity spiraling water stream —
helps operating efficiency by saving
energy, money and improving tank life
• Enhanced -flow brass drain valve
• Temperature and pressure relief valve
included
• HUD certified for manufactured
housing and modular construction
• Low lead compliant
Warranty
• 6-Year limited tank and parts
warranty'
• With Protection Plus" the 6-year limited
tank warranty becomes 10-year
'See Residential Warranty Certificate for complete
information
Units meet or exceed ANSI requirements and have
been tested awarding to the AHRI Operations
Manual and D.O.E. procedures. Units meet or
exceed the energy efficiency requirements of
NAECA, ASHRAE standard 90. ICC Code and all
state energy efficiency performance criteria.
Residential Electric
Water Professional Classic Water Heaters
Professional Classic
19.9 to 55-Gallon Capacities
240 Volt AC/Single Phase
Double and Single Element Models
Electric
A.`_J cEvilneo
See specifications chart on back.
PRINTED IN u5 A. e0/1 ] W P FORM NO, PRIDE PH N Ruv. 6
Residential Electric
w Water Professional Classic Water Heaters
The new degee of carnfl
Professional Classic® Specifications
DESCRIPRON
FEATURES
ROUGHING IN DIMENSIONS (SHOWN
IN INCHES)
ENERGY INFO,
T
Y
P
E
NaMEML
OALLdi
CAPACRY
M1Ep
BALLOX
CAPACITY
MOaEL
NUMBER
UEF
RRBr R
M11N0
arm.
EI'
FP6W THR
RJOINi
"A
RECOVEM
MO.M.
WfM
KK TA
HEIGHT
A
HEIGHTTO
WATER CONK
B
BIANFIER
C
APPROX.
Whew.
DEEP
ENERGY
FACTOR
UNIFORM
ENE WY
FACTOR
Id"I
Tell
30
27
PROEM T2 RH951
48
48
21
47-1/2
sit-a/B
19-1/4
92
0.95
0.92
Tall
40
36
PROE40 T2 RH95'
55
57
21
60-3/4
63-5/8
/9-1/4
109
0.95
0.93
Tall
50
45
PROE50 T2 RH95'
63
67
21
M-5/8
61-5/8
20-1/4
121
0.95
0.93
Tall
55
55
PROE55 T2 RH941
67
71
21
57
59-3/4
22-1/4
128
0.94
0.92
Med.
30
27
PROUD M2 RH95'
45
44
21
37-1/2
40-1/2
20-1/4
92
0.95
0.92
Mod.
40
36
PROE40 M2 RH951
54
55
21
M-1/4
50-1/2
20-1/4
106
0.95
0.93
Mad.
50
45
PROE50 M2 RH95'
62
1 65
1 21
1 48
1 50-1/2
1 23
1 132
0.95
0.0
Short
19.9
PROUD S2 RH
21
31-1/2
31-1/2
17
62
Short
28
25
PROE28 S2 RH95
43
42
21
30
31-1/8
23
95
0.95
0.92
Shot
30
27
PROE30 S2 RH95 B"
43
42
21
30-1/8
32
19-3/4
95
0.95
0.92
Shod
36
33
PROE3682 RH95
46
45
21
31-la
33
24-1/4
118
0.95
0.92
Shari
38
35
PROEM S2 RH95 B"
54
55
21
31-1/2
32-1/8
23
108
0.95
0.0
Short
47
43
PROE47 S2 RH95 B"
54
55
21
32
34
26-1/4
149
0.95
0.0
Lhilorm Energy Factor. Energy Factor and rated gallon capacity based on Department of Energy (DOE) ra0 lremanis.
t System Sentinel optioned. Add ECl to the end of the model moment. System Sentinel not evallabie on single
element models, avelleble an dual elemerd models only. System Sentinel not m alleble In excess of 5 kW an
208 V modele.
Water heater dneman6 pray to insisting a htion bhrket that h included with water feeler.
• Healers hems ed with standard 240 wlt AC, sigh phase non-svnuttare xe; wing. and 4500 watt upper arvt lower healing
elensscts.
• N heating elements of different wanages than those shown are demanded by zone requirements, they must be
speci0cely requested.
• Single element models available on special cater I600Dw mex.). Substituto -I"for -2- in model number.
• Special Wnrg Options - A limped number of special MIN option am evaleble. Consult factory for pnce ard availability
• All models egopped with Mat traps.
Recovery= waltage/2.42 x temp,
Example: 4500W =21 GM
2.42 x 90°
R9COvery calculators feed ere based On 45DIDwalt elements used R nor-slmNXaredrs oe moon.
HOT
WATER
CONNECTIONS
RELIEF VALVE
CONNECTION
•COLD
WATER
WATER CONNECTIONS ALL 314" N.P.T.
In keeping with its policy of continuous progress and product improvement, Rhaem msenves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100
Roswell, Georgia 30076 • www.rheem.com
PRINTED IN UZA OW I? IMP FORM NO. PROE RH N IT,.6