Loading...
HomeMy WebLinkAboutBUILDING PERMITAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: • Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PERMIT TYPE: PLUMBING PROPOSED IMPROVEMENT LOCATION: Permit Number: Building Permit Application Commercial Residential X Address: 7146 Hawks View TRL Saint Lucie West, FL 34986 Property Tax ID #: 3322-615-0010-000-9 Site Plan Name: Project Name: WATER HEATER � ,1��77��iT:TI�Li ►I�I734�N : . 50- GALLON ELECTRIC WATER HEATER REPLACEMENT CONSTRUCTION INFORMATION: Additional work to be performed under this permit— check all that apply: Lot No. Block No. _Mechanical _ Gas Tank —Gas Piping _ Shutters _ Windows/Doors _ Electric Plumbing _ Sprinklers _ Generator _ Roof Pitch Total Sq. Ft of Construction: Cost of Construction: $ 1,382.00 Sq. Ft. of First Floor: Utilities: _Sewer _Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name Thomas J Demaro Name: RICHARD BASSOFF Address: 7146 Hawks View TRL Company: ADMIRAL PLUMBING SERVICES, LLC City: Saint Lucie West FL State: _ Zip Code: 34986 Fax: Phone No. 720-394-5820 Address: 2895 JUPITER PARK DR STE 700 City: JUPITER State: FL Zip Code: 33458 Fax: Phone No 561-746-1180 E-Mail: demaro65@gmail.com Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail PERTMITTING@THEADMIRALPLUMBER.COM State or County License CFC-1426115 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable MORTGAGE COMPANY: _ Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: _Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR ER OR AN ATTORNEY BEFORE RECORDING YOUR41160TICE OF COMMENCEMENT." Signature of OvAerf Lessee/Contract r a ge for Owner Signature of on ractor/Licen a Hol r STATE OF FLORIDA STATE OF FLORIDA COUNTY OF PALM BEACH COUNTY OF PALMBEACH The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me this 30 day of AUGUST 20_ by this 30 day of AUGUST 20 by RICHARD BASSOFF RICHARD BASSOFF Name of person making statement. Name of person making statement. Personally Known x OR Produced Identification Personally Known x OR Type of Identification NotaryPUDGCStateolFloridaFlo Produced u State My Commlaebn cG 233150 �p Expire O6/28/2022 Type ofldentification ��� Notary Public State ofFlonda Produced Jacqueline Georgescu Ex ir"Cawi06/ aion 22 233150 �« � Expirea 0&2812022 OA nature Notary Public- State of Florida) ary Public- State of Florida ) ignature orNin 2(S' ommission No. �233160 (Seal) Commission G m 15o (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED ev. h ' PLUMBING SERVICES A Service Experts Company Billing Address Tom Demaro 7146 Hawks View Trail Port St. Lucie, FL 34986 USA Admiral Plumbing Services A Service Experts Company 2895 Jupiter Park DR #700 Jupiter, FL 33458 561-746-1180 License: CFC 1426115 Description of Work Invoice 25264604 Invoice Date 8/22/2019 Terms COD Completed Date 8/22/2019 Customer PO Job Address Tom Demaro 7146 Hawks View Trail Port St. Lucie, FL 34986 USA Supplied and installed a Rheem 50 gallon electric water heater in garage wit expansion tank, ball valve, and permit. Task# Description Quantity Your Price Your Total T42610 STANDARD 50 GALLON ELECTRIC WATER HEATER 1.00 $925.00 $925.00 A14860 WATER EXPANSION TANK (TANK ONLY) 1.00 $175.00 $175.00 A13210 3/4" BALL VALVE - CXC 1.00 $57.00 $57.00 Permit WH WATER HEATER PERMIT 1.00 $225.00 $225.00 Paid On Type Memo Amount 8/22/2019 Visa $1,382.00 Sub -Total $1,382.00 Tax $0.00 Total Due $1,382.00 Payment $1,382.00 Balance Due $0.00 I hereby agree to have Admiral Plumbing Services A Service Experts Company complete the work described for the proposed price regardless of the time it takes to complete the work. 8/22/2019 1 hereby acknowledge the satisfactory completion of the above described work. 8/22/2019 1 authorize Admiral Plumbing Services A Service Experts Company to charge the agreed amount to my credit card provided herein. I agree that I will pay for this purchase in accordance with the issuing bank cardholder agreement. 8/22/2019 a The new degree of comfort' Professional Classic° electric water heaters are engineered for longer life - resistored heating elements and premium grade anode rod Efficiency •.92-.93UEF • Isolated tank design reduces conductive heat loss • Resistored copper upper element and resistored Lifeguard" stainless steel lower element to prolong anode rod and tank life �3 Performance • FHR: 43 - 67 gallons, based on gallon capacity • Recovery: 21 GPH at a 900 F rise System Sentinel (Available on selected models) • Exclusive diagnostic system with glowing LEDs that verify heating element operation. LEDs pin point the exact location of functioning or non- functioning heating elements Longer Life • Premium grade anode rod provides long-lasting tank protection Features • Electric junction box located above heating elements for easy installation • Over -temperature protector cuts off power in excess temperature situations • Automatic thermostat keeps water at desired temperature Plus... • EverKleen'" self cleaning device fights harmful sediment build-up with a high -velocity spiraling water stream — helps operating efficiency by saving energy, money and improving tank life • Enhanced -flow brass drain valve • Temperature and pressure relief valve included • HUD certified for manufactured housing and modular construction • Low lead compliant Warranty • 6-Year limited tank and parts warranty' • With Protection Plus" the 6-year limited tank warranty becomes 10-year 'See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested awarding to the AHRI Operations Manual and D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90. ICC Code and all state energy efficiency performance criteria. Residential Electric Water Professional Classic Water Heaters Professional Classic 19.9 to 55-Gallon Capacities 240 Volt AC/Single Phase Double and Single Element Models Electric A.`_J cEvilneo See specifications chart on back. PRINTED IN u5 A. e0/1 ] W P FORM NO, PRIDE PH N Ruv. 6 Residential Electric w Water Professional Classic Water Heaters The new degee of carnfl Professional Classic® Specifications DESCRIPRON FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO, T Y P E NaMEML OALLdi CAPACRY M1Ep BALLOX CAPACITY MOaEL NUMBER UEF RRBr R M11N0 arm. EI' FP6W THR RJOINi "A RECOVEM MO.M. WfM KK TA HEIGHT A HEIGHTTO WATER CONK B BIANFIER C APPROX. Whew. DEEP ENERGY FACTOR UNIFORM ENE WY FACTOR Id"I Tell 30 27 PROEM T2 RH951 48 48 21 47-1/2 sit-a/B 19-1/4 92 0.95 0.92 Tall 40 36 PROE40 T2 RH95' 55 57 21 60-3/4 63-5/8 /9-1/4 109 0.95 0.93 Tall 50 45 PROE50 T2 RH95' 63 67 21 M-5/8 61-5/8 20-1/4 121 0.95 0.93 Tall 55 55 PROE55 T2 RH941 67 71 21 57 59-3/4 22-1/4 128 0.94 0.92 Med. 30 27 PROUD M2 RH95' 45 44 21 37-1/2 40-1/2 20-1/4 92 0.95 0.92 Mod. 40 36 PROE40 M2 RH951 54 55 21 M-1/4 50-1/2 20-1/4 106 0.95 0.93 Mad. 50 45 PROE50 M2 RH95' 62 1 65 1 21 1 48 1 50-1/2 1 23 1 132 0.95 0.0 Short 19.9 PROUD S2 RH 21 31-1/2 31-1/2 17 62 Short 28 25 PROE28 S2 RH95 43 42 21 30 31-1/8 23 95 0.95 0.92 Shot 30 27 PROE30 S2 RH95 B" 43 42 21 30-1/8 32 19-3/4 95 0.95 0.92 Shod 36 33 PROE3682 RH95 46 45 21 31-la 33 24-1/4 118 0.95 0.92 Shari 38 35 PROEM S2 RH95 B" 54 55 21 31-1/2 32-1/8 23 108 0.95 0.0 Short 47 43 PROE47 S2 RH95 B" 54 55 21 32 34 26-1/4 149 0.95 0.0 Lhilorm Energy Factor. Energy Factor and rated gallon capacity based on Department of Energy (DOE) ra0 lremanis. t System Sentinel optioned. Add ECl to the end of the model moment. System Sentinel not evallabie on single element models, avelleble an dual elemerd models only. System Sentinel not m alleble In excess of 5 kW an 208 V modele. Water heater dneman6 pray to insisting a htion bhrket that h included with water feeler. • Healers hems ed with standard 240 wlt AC, sigh phase non-svnuttare xe; wing. and 4500 watt upper arvt lower healing elensscts. • N heating elements of different wanages than those shown are demanded by zone requirements, they must be speci0cely requested. • Single element models available on special cater I600Dw mex.). Substituto -I"for -2- in model number. • Special Wnrg Options - A limped number of special MIN option am evaleble. Consult factory for pnce ard availability • All models egopped with Mat traps. Recovery= waltage/2.42 x temp, Example: 4500W =21 GM 2.42 x 90° R9COvery calculators feed ere based On 45DIDwalt elements used R nor-slmNXaredrs oe moon. HOT WATER CONNECTIONS RELIEF VALVE CONNECTION •COLD WATER WATER CONNECTIONS ALL 314" N.P.T. In keeping with its policy of continuous progress and product improvement, Rhaem msenves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com PRINTED IN UZA OW I? IMP FORM NO. PROE RH N IT,.6