Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 BCIS Home Log In ( User Registration Hot Topics € Submit Surcharge j Stats&Facts Publications Contact Us I BCIS Site Map Links Search j Florida rWT-i Product Approval USER:Public User t 4.9k5rttt d��Fcros,;n Product Approval Menu>product or Application Search>Application List>Application Detail �I FL# FL23359-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer CGI Windows and Doors Address/Phone/Email 10100 NW 25 Street Miami,FL 33172 (305)593-6590 Lmiller@pgtindustries.com Authorized Signature Jens Rosowski jrosowski@pgtindustries.com Technical Representative Lynn Miller,P.E. Address/Phone/Email 1070 Technology Dr N Venice,FL 34275 (941)486-0100 Ext 21142 lmiller@pgtindustries.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed A. Lynn Miller,P.E. the Evaluation Report Florida License PE-58705 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 02/19/2023 Validated By Steven M.Urich,PE ® Validation Checklist-Hardcopy Received Certificate of Independence FL23359 R4 COI Cert of Independence.odf Referenced Standard and Year(of Standard) Standard Year TAS-201 1994 TAS-202 1994 TAS-203 1994 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvxHI9oecA%2b... 9/5/2019 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 04/18/2019 Date Validated 04/18/2019 Date Pending FBC Approval 04/25/2019 Date Approved 06/18/2019 Summary of Products FL# Model,Number or Name Description 23359.1 HR-4010A Non-Impact Horizontal Roller Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL23359 R4 II HR4010A.Ddf Approved for use outside HVHZ:Yes Verified By:A.Lynn Miller,P.E.58705 Impact Resistant:No Created by Independent Third Party: No Design Pressure:N/A Evaluation Reports Other:Please see the enclosed documents for product FL23359 R4 AE HR4010 Eno Eval.Ddf performance information,anchorage details,and anchor type, Created by Independent Third Party: No size,and spacing information. 23359.2 HR-4110A Impact Resistant Horizontal Roller Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL23359 R4 II HR4110A.Ddf Approved for use outside HVHZ:Yes Verified By:A. Lynn Miller,P.E.58705 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:N/A Evaluation Reports Other:Please see the enclosed documents for product FL23359 R4 AE HR4110 Eng Eval.pdf performance information,anchorage details,and anchor type, Created by Independent Third Party: No size,and spacing information. 23359.3 SGD-4025A Window Non-Impact,Aluminum Sliding Glass Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL23359 R4 II SGD-4025A-W.Ddf Approved for use outside HVHZ:Yes Verified By:A. Lynn Miller,P.E.PE-58705 Impact Resistant:No Created by Independent Third Party: No Design Pressure:N/A Evaluation Reports Other:Please see the enclosed documents for product FL23359 R4 AE SGD4025A-W-Eng Eval.pdf performance information,anchorage details,and anchor type, Created by Independent Third Party: No size,and spacing information. 23359.4 SGD-4130A Window Impact Resistant,Aluminum Sliding Glass Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL23359 R4 II SGD-4130A Window.Ddf Approved for use outside HVHZ:Yes Verified By:A.Lynn Miller,P.E.PE-58705 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:N/A Evaluation Reports Other:Please see the enclosed documents for product FL23359 R4 AE Eng Eval SGD-4130 Window.pdf performance information,anchorage details,and anchor type, Created by Independent Third Party: No size,and spacing information. Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: W,q11 M 99 M Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvxHI9oecA%2b... 9/5/2019 SERIES 4110A IMPACT RESISTANT DESIGN PRESSURE RATING IMPACT RATING I HORIZONTAL ROLLER WINDOW VARIES, RATED FOR LARGE&SMALL � 1)THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY SEE SHEET 4 MISSILE IMPACT RESISTANCE I WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, I INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ). 74"OVERALWIDTH _ '.I 111"OBUCK IDTH 73"BUCK WIDTH 110"BUCK WIDTH 2)SHUTTERS ARE NOT REQUIRED WHEN USED IN WIND-BORNE B B DEBRIS REGIONS. 3)MASONRY ANCHORS MAYBE USED INTO WOOD AS PER TABLE 2.ALL WOOD BUCKS LESS THAN 1-1/2"THICK ARE TO BE CONSIDERED 1X INSTALLATIONS.1X WOOD BUCKS ARE ,r OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. C. d! rfl _C / // WOOD BUCKS DEPICTED AS 2X ARE 1-12"THICK OR GREATER. 63" f .A A' 1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED TO OVERALL PROPERLY TRANSFER LOADS TO THE STRUCTURE.WOOD BUCK HEIGHT / s, OVERALL r DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE 62" HEIGHT ENGINEER OR ARCHITECT OF RECORD, r 4)ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND BUCK 62° WALL DRESSING OR STUCCO.USE ANCHORS OF SUFFICIENT HEIGHT BUCK / A)114-112-114 @ 63"HEIGHT LENGTH.INSTALLATION ANCHORS SHOULD BE SEALED. HEIGHT ° JR,10109/18 OVERALL SEALINCIFLASHING STRATEGY FOR WATER q RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. 5)SHIMS ARE REQUIRED AT EACH FLANGE ANCHOR LOCATION y .-- WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE.USE L - ALWAYS 3" -8 3.3116" SEE NOTE A, B 3-3116" SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS.WOOD ALWAYS _ I~ a BUCKS,BY OTHERS,MUST BE SUFFICIENTLY ANCHORED TO REQUIRED SEE NOTE D,THIS SHEET REQUIRED THIS SHEET 3" w m > o 0 Q CORNERS CORNERS SEE NOTES g m z aloe 0 J RESIST LOADS IMPOSED ON THEM BY THE WINDOW. Q B&C.THIS SHEET 7rC 6)THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TYP.XO ELEVATION.(OX SIM.) TYP.XOX -1/3-1/3)ELEVATION }Y„ ? o� z v TO RESISTTHEWIND LOADS CORRESPONDING TO THE < rc REQUIRED DESIGN PRESSURE.THE 33-113%STRESS INCREASE ff J LL g _ HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.THE 1.6 rp O o O LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ❑=LL'o° F i2 Li 'vr'pory ANCHORS INTO WOOD.ANCHORS THAT COME INTO CONTACT 0�d w mg Omo WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE < z< v o REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR Ill"OVERALL WIDTH w n o Ip CORROSION RESISTANCE. 110"BUCK WIDTH °' Z° 0 5 C O Ulaays USER INSTRUCTIONS; / o'� O rn 1)DETERMINE THE SITE SPECIFIC,WINDOW OPENING'S DESIGN PRESSURE REQUIREMENT USING WINDLOAD STANDARD ASCE 7. 0 //r t y o o OQ Z A 0/ cc f 3 z Z 2)KNOWING YOUR WINDOW CONFIGURATION(OX,XO,XOX),SIZE AND GLASS TYPE,DETERMINE YOUR WINDOWS DESIGN PRESSURE % ' A vw W REOUIREM ENT FOR THE WINDOW OPENING USING TABLE 2,IT MUST EQUAL OR EXCEED THE DESIGN PRESSURE REQUIREMENT FOR 63„ f s o o y m W along THE WINDOW OPENING OBTAINED IN STEP 1. OVERALL. E 3 3 N F�N 2 to o 3)DETERMINE THE MOST SUITABLE ANCHOR GROUP FROM TABLET ACCORDING TO THE INSTALLATION CONDITIONS. HEIGHT ® o O Of 4)DETERMINE THE ANCHOR QUANTITY FROM SHEET 2.VERIFY THAT THE ANCHOR/SUBSTRATE WILL MEET REQUIREMENTS FOR YOUR 82° U =m Q Z = BUCK- apq asap saua5 OPENING'S CONDITION FROM TABLE 1,AND THATALL MIN,REQUIREMENTS FROM THIS SHEET SET ARE MET. HEIGHT �- 5)INSTALL ASPER SHEET 3. fj ' „ `',%,%%I \ .. GENERAL NOTES.... LCENNSEN, ( 7 i ELEVATIONS............ .....1 No.58705 ? ANCHOR SPECIFICATIONS ..2 7k' ALWAYS THIS SH E A, g f~ 3-3116° ANCHOR SPACINGIOUANTRIES..2 CODES/STANDARDS USED: SEE NOTES _` y_ 3" 7k- •2017 FLORIDA BUILDING CODE(FBC),6TH EDITION REQUIRED THIS SHEET B&C. - INSTALLATION......... ...3 @CORNERSq' /p° DESIGN PRESSURES .....4 -ASTM E13OD-04 WEEPHOLE NOTES: THIS SHEET O t, 0 GLAZING DETAILS,- ....,4 •ANSI/AF&PA NDS-2015 FOR WOOD CONSTRUCTION A REQUIRED IF WINDOW WIDTH IS OVER 67'. 0,� FTA CORNER ASSEMBLY......................5 -ALUMINUM DESIGN MANUAL,ADM-2015 B.REQUIRED IF WINDOW WIDTH IS OVER 45"AND UP TO 67".. TYP.XOX(1/4-1/2-1/4)ELEVATION FS•• ORION. •��?� EXTRUSION PROFILES.................6' •AISI S100-12 C.REQUIRED IF WINDOW WIDTH IS OVER 89', i, s ••• G�� PARTS LIST..P.......... 6 •AISC 360-10 D.REQUIRED IF WINDOW WIDTH IS OVER 45". A LYNN MILLER,RE, P.E.#58705 111'OVERALL WIDTH ...-� 74"OVERALL WIDTH =i 1 ANCHOR @ MIDSPAN 1 ANCHOR ON I 1 ANCHOR ON 1 ANCHOR ON tANCHOR 1ANCHOR EACH SIDE OF I tANCHOR AT EACH SIDE OF + EACH SIDE OF THE MEETING I 1 ANCHOR ATI THE MEETING THE NG 'AT CORNER RAIL AT CORNER I I CORNER RAIL RAIL RAIL CORNER t I 1 9"MAX. T — 9°MAX. visIBLE I 33-511 } • y_ FU(ED _ LIGHT _1 56-9116" << 57-13!16 57-13!16jf 56-9/16" %� ' t SASH . FIXED SASHJ/J �/ t VISIBLE ' VISIBLE ! 150M1ACN('OVERALL OVERALL VISIBLE I�—`,) VISIBLE Z�j „ 15"MAX. LIGHT LIGHT HEIGHT HEIGHT LIGHT �%' LIGHT O.C. � I � A)114-1/2-1/4 @ 63•HEIGHT 335/16" 335/16" � 33-5116JR,10/09/16 " •� SASH _ SASH I SASH VISIBLE �' VISIBLE { r VISIBLE LIGHT LIGHT ( I LIGHT aD "aa_ I i I I H N 9 MAX. I _ 9"MAX.FROM CENTER 9 I� 9"MAX.FROM CENTER cc 0 0 ¢ I` OF MEETING RAIL —' OF MEETING RAIL alo0 p 0. TYP.XO ANCHORAGE(OX SIM.) TYP.XOX(1/3-1/3-1/3)ANCHORAGE w &MAX.VISIBLE LIGHT OPENING &MAX.VISIBLE LIGHT OPENING '' LU ¢O' a ®x x 'm o,�g o !E Ke 111"OVERALL WIDTH --i o=wF= 0,; I WW "O1c -oN UUd W 2 ANCHORS a i^ U �k JM0o 1 ANCHOR ON 1 ANCHOR ON a FOR FRAME EACH SIDE OF EACH SIDE OF u_ TABLE is WIDTHS 109" ! �o z� � THE MEETING THE MEETING MIO. AND OVER, O Anchor Type Frame Substrate Min.Edge Min.O.C. Embedment or 1 ANCHOR RAIL OTHERWISE 1 RAIL 1 ANCHOR N Member Distance Distance ATCORNER ANCHOR Metal Thickness i AT CORNER I.. 49 o r z 7aa45 Southern Pine SG-0.55 9/16" 7/8" 13/8" - #12,Steel SMS(Gr.5 ( - ) � I� � IT-) t ; j IL e"MAX, y � �' O � or 410 SS,(min.of 3 6063-T5 Aluminum 318" 9/16' 0.060" l - s y o Z p z threads beyond metal All A36 Steel 3/8" 9/16" 0.050" j I ;9 w z substrate) Gr.33 Steel Stud 318" 9116• 0.045•(20 Ga) ! E�I s y� � � ¢ Jamb Hollow or Filled Block,(ASTM C90) 2-1/2" 6" 1-1/4" '' %' 1 _ 1/4"Elco UltraCorl® All Concrete(min.2.85 ksi) 2-112" 4" 13/8" 63• SSASH• SFuceD 15.Mnx ® o o 2 of OVERALL All Southern Pine(SG=0,55) 1-1/16" 1-1/16" 13/8" v151BLE VISIBLE 2 HEIGHT LIGHT I O.C. v.^a i ant _ a0 sagas 1/4"410 SS Elco Jamb Hollow or Filled Block,(ASTM C90) 1-3/4" 1 6" 1-1/4" LIGHT CreteFlex® All Concrete(min.3.35 ksi) 2-112" 4" 1314' �.�`1�IIYILYN '- 2451T IFTHE FRAME CONTAINS A FACTORY COUNTERSINK,ONLY USE FLATHEAD ANCHORS AT THAT LOCATION. SASH N f .1.vi '�_ 50 3/6 FOCED..... UGENS VISIBLE! F �� . I. LIGHT VISIBLE LIGHT � No.58705 9"MAX. 9"MAX.FROM CENTER 13/ l � ;•�.` OF MEETING RAIL �,n'•, .`STA E F :• (V TYP.XOX(1/4-1/2-1/4)ANCHORAGE ��'SiS,�ONAL &MAX.VISIBLE LIGHT OPENING //rn 11111`` A LYNN MILLER,RE P.E#56705 I I i LOCKSATSASH SIDE RAIL OR 7 MEETING RAIL SHOWN EDGE DISTANCE EMBEDMENT 110 INSTALLED THRU j / \ I _ 1X SUCKSTRIP DISEDGETANCE ,`/• J,�'I� X /3' X EMBEDMENT EMBED- "C7 �. / / ��• / MENT 1A I / Y - ° lI \\\\` DISTANCE —100 EXTERIOR / 1`5 A)1/a-12-1/4@63"HEIGHT a JR,10/09/18 8 BUCK WIDTH OVERALL WIDTH ED Y ¢ OVERALL HORIZONTAL SECTION A-A w N 3: w o O ¢ HEIGHT \,;•__;, -_ r- 4, j aloe #12 STEEL SELF DRILLING S Q p J BUCK Ow X SMS(G5),SEE TABLE 1 Y �a Z p HEIGHT #12 STEEL �lJ - �11?-- •� > o riH� W SELF DRILLING X ¢O < g -� _ SMS(G5),SEE m O �. O �8 TABLE 1 I,.: Z LL ~ vma�Cl LE 114x' 5._ SHOWN I j pIL, INSTALLED f W o U i 50 DIRECTLY INTO I y -+. O CL i LL O _ METAL, y - ._�.: --1121z CO �, )� ....... .,...,_.............M,....,..,!`-R,,,,,, __. � o INSTALLED INTO \' EXTERIOR _ m°a fi O O APPROVED ALUMINUM, �I, 3 z� Z F Z STEEL FRAMING OR �/' 6/ m v' LU m LU aiaas 29STEEL STUD. v 6 z a 0' /n ¢ 29' N BUCK WIDTH ® ¢S ,P y o �! OVERALL WIDTH o'==" O U = stlowN HORIZONTAL SECTION C-C MULLION SECTION �mso Un2C INSTALLED THRU al11.•asap sauag �,.. 1X BUCKSTRIP APPROVED MULLION,MAY BE ` VERTICAL OR HORIZONTAL, � X77 `�.X9\0 LYNN /•,�,,'•F�x it/ T ; E DISTANCE LIMR'S.ANY se OYES: �10EN 1 USE ONLY SUBSTRATE APPROPRIATE ANCHORS LISTED IN TABLE 1.FOLLOW EMBEDMENT AND EDGE Q-;' CC y INSTALLATION OPTION SHOWN MAYBE USED ON ANY SIDE OF THE WINDOW. P EXTERIOR. ,l! /:� / .' �` 1 �.� Na.58705 :• *� 2)MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE 1.ALL WOOD BUCKS LESS THAN 1-1/2"THICK ARE TO BE CONSIDERED 1X INSTALLATIONS.1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE.WOOD BUCKS DEPICTED AS 2X ARE 1-1l2"THICK OR GREATER.1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE _ . f 0 EDGE DISTANCE STRUCTURE.WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. T 3A O (p` VERTICAL SECTION B-B 3)SEE SHEET 28 TABLE I FOR SPACING REQUIREMENTS. �i,�s •F.O....SN.••o 4)MAX.SHIM THICKNESS TO BE 114". s10lVAL I 5)GLASS SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER TO MEET DESIGN REQUIREMENTS. A LYNN MILLER,P.E. P.E#68705 I , TABLE2i DESIGN a, O%erall Height PRESSURE 0 38-3/8" 43-1/2" 50-518" 63" I (per Glass Type 1 Glass Type 2 Glass Type 1 Glass Type 2 Glass Type 1 Glass Type 2 Glass Type 1 Glass Type 2 26-1/2" +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +551-65 +55/-65 +55/-65 t j 37" +551-65 +55/-65 +55/-65 +551-65 +55/-65 +55/-65 +55/-65 +551-65 45" X +55/-65 +55/-65 +55/-65 +551-65 +551-65 +551.65 +55/-65 +55/-65 49" o +55/-65 +55/-65 +551-65 +55/-65 +55/-65 +551-65 +551-65 +55/-65 53-1/8" Q +55/-65 +55/-65 +551-65 +55/-65 +55/-65 +55/-65 +551.65 +55/-65 X 61" +55/-65 +551-65 +55/-65 +55/-65 +55/-65 +55/-65 +551-65 +55/-65 66" +55/-65 +55/-65 +55/-65 +55/-65 +551-65 +55/-65 +55/-65 +55/-65 74" +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55.0/-63.2 +55/-65 L 53-1/8- +55/-65 +55/-65 +551-65 +55/-65 +55/•85 +55/-65 +55/-65 +55/-65 A)114-12-114 @ 63- EIGHT JR,10!09116 61" +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +551-65 p 74" +55/-65 +55/-65 +551-65 +55/-65 +55/-65 +551-65 +55/-65 +55/-65 _ O 85" +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 °r Y 97" X +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 111" X +55/ 5 +551.65 +55/-65 +55/-65 +551-65 +55/-650 +55.0/-63.2 +55/-65 53-1/8" +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 ZF �� o 74" +55/-65 +55/-65 +55/-65 +55/-65 +551.65 +551-65 +551-64.8 +55/-65 Z H z N W 85" +55l�5 +55/-65 +55/-65 +551-65 +551-65 +55/-65 +55/-57.9 +55/-65 >o.g o e d a = f 9T' a +551-65 +55/-65 +55/-65 +55/•65 +55/-65 +55/-65 +53.51-53.5 +55/-65 0=w E u a °"a° '"N W U U d It R Z JMG 109" X +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +50.4/-50.4 +55/-65 w z< V 111" XO +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +50/50 +55/-65 a c= u� O ;c i iaa45 5116"NOM. 5116"NOM. •–ac5fA i Q GLASS STACK GLASS STACK—�I I� s�+a OQ Z 3s. zw Z t1 arca 1/8"HEAT-STRENGTHENED II.GLASS n c G m Z 5 118"ANNEALED GLASS o y .090"PVB .GLA S O $LL„ = O= 118°ANNEALED GLASS. 1!8"HEAT-STRENGTHENED GLASS °oma= U v oo�O J Z 5/16"LAW GLAZING 5/16"LAMI.GLAZING �m a 2 GLASS TYPE 1 GLASS TYPE 2 LYNtv !�> TABLE 3: No:S8705 Laminated Glass Types `(•2; 1 1/8"Annealed,0.090"PVB,118"Annealed 2 1/8"Heat-strengthened,0.090"PVB,1/8"Heat-strengthened %O,c'., 'STA `F INTERLAYER MAY BE SAFLEX PVB OR TROSIFOL PVB i��`s'••:c<OF21DP.-''G\?� NOTES: 1)FOR SIZES NOT SHOWN,ROUND UPTOTHE �!!!l/11111111� NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. A.LYNN MILLER,RE P.E#58705 i I 9 'a r i 28 10 28 a 3 12 A)114-12-114@63°HEIGHT JR.10/09/18 11 z` Oe Q Y w Z!cc 04 j nay W n O O Q a 2 � 2. � aloe 0 O J LLFRAME a 'S� � z v zs CORNERS SASH d°oma W CORNERS MEETING RAIL m o n o a = .,� C 2 e F 0, .o,n .ON ASSEMBLY DETAILS co U- W J. c o z � O_laa4g O:SILL ADAPTER DOW-899 OR .—" ¢$+ GE-7700 as aD p ❑ d BACKBEDDING s H3'E z� Z W Z C Z�m along 50 12"NOM' E3 Z�' m Q 3 GLASS BITE <= Z W .3. EXTERIOR ® 08i � a. a 03 .. O OC US=� Q U 2 2 N1 'asap sa��a5 �I zso 330 ' TYP.GLAZING DETAIL O 04. .415• ov LYNN , ��..• 1,lCENSF, /�� �+- 1.200" 1.200" WEEPHOLES i}; Nq 58705: 1.Boo" WEEPHOLE DETAILS `_�0 �IA %71 :SHOWN WITHOUT WEEPHOLE COVERS. <.n (�F - 2 SILL SEE SHEET 1 FOR QUANTITY AND SPACING "U'9•••,.OR10 Q, �'', ZONAL AKN wtlliA P.E. P.E#58705 1 ( TABLE 4: Item Description 2.000" .875" I-- 1 Fume Head 2 Frame Sill 2.000" 3 Sill Adapter I, 4 Frame Jamb(Fixed) .062" 5 Frame Jamb(Operable) .. r 050" z.eza" 6 Heavy Duty Fixed Meeting Rai) I .062" 2'610 z.12a^ 111 � 7 Side Rail Lock zoos^ - ! 8 Sash Top&Bottom Rail 10 Sash Side Rail 0,. .: 11 Sash Meeting Rail .05 .062'- .062" 12 Dogbone Reinforcement 13 Sash Stop 1O FRAME HEAD 0 FRAME SILL O SILLADAPTER O FRAME JAMB(FIXED? 14 Beading .6063-T8ALUMINUM 60fi3-T MINUM 0 J- A UM NUM 6083-TB ALUMINUM A)1!4-112-114 Q 83°HEIGHT 23, .190"X.200"Q-Ion Wstp.(Frame) _ � JR,10!09118 24 :187"X:230"Fin Wstp. 25 =Bulb Vinyl Wstp.(Sash) 2.463" 29 Weephole Cover 1.845' 00 ¢ 30 Sweep Latch 31 Roller Housing&Guide 32 Roller .050^ 1s31^ w c ¢ 50,Setting Block 3/32"X 1/4"X 1" 0sz° ssa^ —� szs" I~ g z alo0LL 81 Silicone G azmg Sealant z.za5^ .062" f z.01o^ osz° 10 a .., m a n < m ca V O� a Ra of � r .093" .87N' 1,245" ¢ .oN 1111 IUr/1 U U U, k? DMO- .062". z U o W,�� ti co BLE) HD RAIL SIDE RAIL LOCK O 603T6MNO 6063IT6 ALUMNUM 6A 6063-T6 ALUMINUM O qP 8 BOTTOM RAIL 10 6063-T6 ALUMISASH SIDE RAIL NUM �o o En 1aa45 0 ,42 0 z0 W m"110 �" � r z z 1.932° { _ c al0as I 1..113 E " ZeZn X Q 6FLL ` o '1.115" ¢$ T- ® 0 ? O 5Ma o ..¢ m ..2 x aN!1 asap,^auag .318" LYNN DOGBONE 085' 11 6063-TB AEUMNUMIL 12'" REINFORCEMENT 13; SAB��ALUMINUM SH STOP., 14 'P CLAML BEADING 8063-T6 ALUMINUM -*j No,58705 O ' STAT o ''iS;ONAL A,LYNN MILLER,P.E. P.E#58705