Loading...
HomeMy WebLinkAboutBUILDING PERMITAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X PERMIT TYPE: PLUMBING PROPOSED IMPROVEMENT LOCATION: Address: 8151 Carnoustie PL Port St Lucie, FL 34986 Property Tax ID #: 3327-503-0022-000-7 Site Plan Name: Project Name: WATER HEATER DETAILED DESCRIPTION OF WORK: 50- GALLON ELECTRIC WATER HEATER REPLACEMENT CONSTRUCTION INFORMATION: Additional work to be performed under this permit —check all that apply: _Mechanical _ Electric _ Gas Tank X Plumbing Total Sq. Ft of Construction: Cost of Construction: $ 1,300.00 Lot No. Block No. _ Gas Piping _Shutters _ Windows/Doors _ Sprinklers _ Generator _ Roof Pitch Sq. Ft. of First Floor: Utilities: _ Sewer _ Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name Jeff O'Connor Name: RICHARD BASSOFF Address: 8151 Carnoustie Place Company: ADMIRAL PLUMBING SERVICES, LLC City: PORT SAINT LUCIE FL State: _ Zip Code: 34986 Fax: Phone No. 407-709-0004 Address: 2895 JUPITER PARK DR STE 700 City: JUPITER State: FL Zip Code: 33458 Fax: Phone No 561-746-1180 E-Mail:leffocon6@gmail.com Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail PERTMITTING@THEADMIRALPLUMBER.COM State or County License CFC-1426115 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable MORTGAGE COMPANY: Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: _Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." SiWufe of Owner/ Lessee/Cora s gent for Owner Signature of Contractor/L tense of STATE OF FLORIDA STATE OF FLORIDA COUNTY OF PALM BEACH COUNTY OF PUMeEncH The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me this 30 day of AUGUST 201!0i_ by this 30 day of AUGUST . 200 by RICHARD BASSOFF RICHARD BASSOFF Name of person making statement. Name of person making statement. Personally Known X tjeptjf Personally Known x OR Pr 004 Type of Identification .y. NcuiyauaiCSan, IfFWW1 Produced : Jacqueline Geor9Bscu +� mmiasion GG 233t 5o Expires0 8=QC22 Type ofldentification NctllPublic State ofF Produced JcueIk* G9B Nly C Iaslon GG 233 a E'�=�M22 rSidC gnature Notary Public- State of Florida) nature of ftary Public- State of Florida ) Commission No. 1,5 (Seal) Commission No.6761LU),50 (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED ev. PLUfVIBING SERVICES A Service Experts Company Billing Address Jeff O'Connor 8151 Carnoustie Place Port St. Lucie, FL 34986 USA Admiral Plumbing Services A Service Experts Company 2895 Jupiter Park DR #700 Jupiter, FL 33458 561-746-1180 License: CFC 1426115 Description of Work Invoice 25347322 Invoice Date 8/30/2019 Terms COD Completed Date 8/30/2019 Customer PO Job Address Jeff O'Connor 8151 Carnoustie Place Port St. Lucie, FL 34986 USA Installed new 50 gallon Rheem electric water heater with new ball valve, new expansion tank and permit. Task# Description Quantity Your Price Your Total T42610 STANDARD 50 GALLON ELECTRIC WATER HEATER 1.00 $925.00 $925.00 Permit WH WATER HEATER PERMIT 1.00 $225.00 $225.00 A14860 WATER EXPANSION TANK (TANK ONLY) 1.00 $175.00 $175.00 Discount Discount- Angie'sList 1.00 $-25.00 $-25.00 A13210 3/4" BALL VALVE - CXC 1.00 $57.00 $57.00 D70657 Discount -Courtesy 1.00 $-57.00 $-57.00 Paid On Type Memo Amount 8/30/2019 Visa $1,300.00 Sub -Total $1,300.00 Tax $0.00 Total Due $1,300.00 Payment $1,300.00 Balance Due $0.00 I hereby agree to have Admiral Plumbing Services A Service Experts Company complete the work described for the proposed price regardless of the time it takes to complete the work. LYJ1" T ii... . 8/30/2019 1 hereby acknowledge the satisfactory completion of the above described work. 8/30/2019 1 authorize Admiral Plumbing Services A Service Experts Company to charge the agreed amount to my credit card provided herein. I agree that I will pay for this purchase in accordance with the issuing bank cardholder agreement 9;V��4 7��/� Z�� 8/30/2019 a The new degree of comfort" Professional Classic° electric water heaters are engineered for longer life - resistored heating elements and premium grade anode rod Efficiency •.92-.93 UEF • Isolated tank design reduces conductive heat loss • Resistored copper upper element and resistored Lifeguard" stainless steel lower element to prolong anode rod and tank life Performance • FHR: 43 - 67 gallons, based on gallon capacity • Recovery: 21 GPH at a 90' F has System Sentinel (Available on selected models) • Exclusive diagnostic system with glowing LEDs that verify heating element operation. LEDs pin point the exact location of functioning or non- functioning heating elements Longer Life • Premium grade anode rod provides long-lasting tank protection Features • Electric junction box located above heating elements for easy installation • Over -temperature protector cuts off power in excess temperature situations • Automatic thermostat keeps water at desired temperature Plus... • EverKleen'" self cleaning device fights harmful sediment build-up with a high -velocity spiraling water stream — helps operating efficiency by saving energy, money and improving tank life • Enhanced -flow brass drain valve • Temperature and pressure relief valve included • HUD certified for manufactured housing and modular construction • Low lead compliant Warranty • 6-Year limited tank and parts warranty' • With ProtectionPlus" the 6-year limited tank warranty becomes 10-year 'See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according to the AHRI Operations Manual and D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, CC Code and all state energy efficiency performance criteria. Residential Electric Water Professional Classic Water Heaters Professional Classic 19.9 to 55-Gallon Capacities 240 Volt AC/Single Phase Double and Single Element Models Electric !r'9 crxiineo See specifications chart on back. PRIMED IN usA 08117 wP FORen No. PROE RH N Rev. 6 10 The new degee of cwnforY Professional Classic" Specifications Residential Electric Water Professional Classic Water Heaters DESCRIPTION FEATURES ROUGHING IN DIMENSIONS(SHOWN IN INCHES) ENERGYINFO. T Y P E NOMINAL GALLON CAPACITY MTEO GALLON CAMCNT MODEL NUMBER UEF RRSTHOUR RATMO GPM. EF FIRSTHOUR MTNG O.P41. RECOVERY IN ORR W )RISE TANK HEIGHr A HENINTTO WATER CONN. a OMMETEN C APPnOx. eHIPM.. 0as4 ENERGY FACTOR UNIFORM ENERGY FACTOR NER Tell 30 27 PROE30 T2 RH951 48 48 21 47-12 50-3/6 19-1/4 92 0.95 0.92 Tall 40 36 PROE40 T2 RH951 55 57 21 60-3/4 63-5/8 19-1/4 109 0.95 0.93 Tell 50 45 PROE50 T2 RH95' 63 67 21 58-5/8 61-5/8 20-1/4 121 0.95 0.93 Tell 55 55 PROE55 T2 RH941 67 71 21 57 59-W4 22-1/4 128 0.94 0.92 Mad. SO 27 PROM M2 RH951 45 44 21 37-1n 40-M 2OA14 92 0.95 0.92 Med, 40 36 PROE40 M2 RH951 54 55 21 48-1/4 50-W 20-1/4 106 0.95 0.03 Med. 50 45 PROM M2 RH951 62 1 65 1 21 1 48 1 50-12 1 23 132 0.95 0.0 Short 19.9 MOM 82 PH 21 31-12 31-1/2 17 62 Shon 28 25 PROE28 S2 RH95 43 42 21 30 31-1/8 23 95 0.95 0.92 Shod 30 Z7 PROE3052 RH95 B" 43 42 21 MAIM 32 19-3/4 95 0.95 0.92 Short S6 33 PROE36 S2 RH95 46 45 21 31-12 33 24-1/4 118 0.95 0.92 Short 38 35 PROE38 S2 RH95 B-- 54 55 21 31-12 32-578 23 108 0.95 0.93 Shed 47 43 PROE47 S2 RH95 B-- 54 55 21 32 34 26-1/4 149 0.95 0.93 Uniform Energy Factor. Eergy Factor and rated gallm oapa ity based on Department of Energy (DOE) requirements. t System Sentinel optional. Add ECl to the end of the model number. System Sentinel not available on single element models, avallable on dual element models only. System Sentinel not available In excess of 5 kW on 208 V models. -Water heater dourfunns poor to installing iLsubtlm blanket Ihat is nnutled with water healer. • Heaters funneled with standard! 240 wtt AC, single phase non -simultaneous wiring, and 4500 wa t upper and comer ruling elements. • 9 heating elements of different wattages than those shown are demanded by zone requirements, they must be .P.4fically requested. • Sn9c element stories available on special order (6000W max.). Suirstituto-1"for -F it model number. •Special Winlg Options- A mrited number of special wirng options am av ks,la. Consult factory for price and avw1aMity. • All models equipped with heat baps. Recovery= wattage2.42 x IMP. rise °F. Example: 450OW =21 GPH 2.42 x 90 Recovery wkule8orls used are based an 4500 watt eienvnts used If non s4rweanepts operation. HOT RELIEF VALVE CONNECTION •COLD WATER ROD WATER CONNECTIONS ALL 3/4" N.P.T. In keeping with its policy o/continuous progress and product improvement. Rheem reserves the nghf to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.dleem.com PRINTED IN USA Cut? WP FORM NO. PROE aR N Rw.6