HomeMy WebLinkAboutBUILDING PERMITAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date:
Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X
PERMIT TYPE: PLUMBING
PROPOSED IMPROVEMENT LOCATION:
Address: 8151 Carnoustie PL Port St Lucie, FL 34986
Property Tax ID #: 3327-503-0022-000-7
Site Plan Name:
Project Name: WATER HEATER
DETAILED DESCRIPTION OF WORK:
50- GALLON ELECTRIC WATER HEATER REPLACEMENT
CONSTRUCTION INFORMATION:
Additional work to be performed under this permit —check all that apply:
_Mechanical
_ Electric
_ Gas Tank
X Plumbing
Total Sq. Ft of Construction:
Cost of Construction: $ 1,300.00
Lot No.
Block No.
_ Gas Piping _Shutters _ Windows/Doors
_ Sprinklers _ Generator _ Roof Pitch
Sq. Ft. of First Floor:
Utilities: _ Sewer _ Septic Building Height:
OWNER/LESSEE:
CONTRACTOR:
Name Jeff O'Connor
Name: RICHARD BASSOFF
Address: 8151 Carnoustie Place
Company: ADMIRAL PLUMBING SERVICES, LLC
City: PORT SAINT LUCIE FL State: _
Zip Code: 34986 Fax:
Phone No. 407-709-0004
Address: 2895 JUPITER PARK DR STE 700
City: JUPITER State: FL
Zip Code: 33458 Fax:
Phone No 561-746-1180
E-Mail:leffocon6@gmail.com
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
E-Mail PERTMITTING@THEADMIRALPLUMBER.COM
State or County License CFC-1426115
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: _ Not Applicable
MORTGAGE COMPANY: Not Applicable
Name:
Name:
Address:
Address:
City: State:
City: State:
Zip: Phone
Zip: Phone:
FEE SIMPLE TITLE HOLDER: _ Not Applicable
BONDING COMPANY: _Not Applicable
Name:
Name:
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT."
SiWufe of Owner/ Lessee/Cora s gent for Owner
Signature of Contractor/L tense of
STATE OF FLORIDA
STATE OF FLORIDA
COUNTY OF PALM BEACH
COUNTY OF PUMeEncH
The forgoing instrument was acknowledged before me
The forgoing instrument was acknowledged before me
this 30 day of AUGUST 201!0i_ by
this 30 day of AUGUST . 200 by
RICHARD BASSOFF
RICHARD BASSOFF
Name of person making statement.
Name of person making statement.
Personally Known X tjeptjf
Personally Known x OR Pr
004
Type of Identification .y. NcuiyauaiCSan, IfFWW1
Produced : Jacqueline Geor9Bscu
+� mmiasion GG 233t 5o
Expires0 8=QC22
Type ofldentification NctllPublic State ofF
Produced JcueIk* G9B
Nly C Iaslon GG 233
a E'�=�M22
rSidC
gnature Notary Public- State of Florida)
nature of ftary Public- State of Florida )
Commission No. 1,5 (Seal)
Commission No.6761LU),50 (Seal)
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
RECEIVED
DATE
COMPLETED
ev.
PLUfVIBING SERVICES
A Service Experts Company
Billing Address
Jeff O'Connor
8151 Carnoustie Place
Port St. Lucie, FL 34986 USA
Admiral Plumbing Services
A Service Experts Company
2895 Jupiter Park DR #700
Jupiter, FL 33458
561-746-1180
License: CFC 1426115
Description of Work
Invoice 25347322
Invoice Date 8/30/2019
Terms COD
Completed Date 8/30/2019
Customer PO
Job Address
Jeff O'Connor
8151 Carnoustie Place
Port St. Lucie, FL 34986 USA
Installed new 50 gallon Rheem electric water heater with new ball valve, new expansion tank and permit.
Task#
Description
Quantity Your Price
Your Total
T42610
STANDARD 50 GALLON ELECTRIC WATER HEATER
1.00
$925.00
$925.00
Permit WH
WATER HEATER PERMIT
1.00
$225.00
$225.00
A14860
WATER EXPANSION TANK (TANK ONLY)
1.00
$175.00
$175.00
Discount
Discount- Angie'sList
1.00
$-25.00
$-25.00
A13210
3/4" BALL VALVE - CXC
1.00
$57.00
$57.00
D70657
Discount -Courtesy
1.00
$-57.00
$-57.00
Paid On
Type Memo
Amount
8/30/2019
Visa
$1,300.00
Sub -Total $1,300.00
Tax
$0.00
Total
Due $1,300.00
Payment $1,300.00
Balance Due $0.00
I hereby agree to have Admiral Plumbing Services A Service Experts Company complete the work described for the proposed price
regardless of the time it takes to complete the work.
LYJ1" T ii... .
8/30/2019
1 hereby acknowledge the satisfactory completion of the above described work.
8/30/2019
1 authorize Admiral Plumbing Services A Service Experts Company to charge the agreed amount to my credit card provided herein. I
agree that I will pay for this purchase in accordance with the issuing bank cardholder agreement
9;V��4 7��/� Z��
8/30/2019
a
The new degree of comfort"
Professional Classic° electric water heaters are
engineered for longer life - resistored heating
elements and premium grade anode rod
Efficiency
•.92-.93 UEF
• Isolated tank design reduces
conductive heat loss
• Resistored copper upper element and
resistored Lifeguard" stainless steel
lower element to prolong anode rod
and tank life
Performance
• FHR: 43 - 67 gallons, based on gallon
capacity
• Recovery: 21 GPH at a 90' F has
System Sentinel
(Available on selected models)
• Exclusive diagnostic system with
glowing LEDs that verify heating
element operation. LEDs pin point the
exact location of functioning or non-
functioning heating elements
Longer Life
• Premium grade anode rod provides
long-lasting tank protection
Features
• Electric junction box located above
heating elements for easy installation
• Over -temperature protector cuts
off power in excess temperature
situations
• Automatic thermostat keeps water at
desired temperature
Plus...
• EverKleen'" self cleaning device fights
harmful sediment build-up with a
high -velocity spiraling water stream —
helps operating efficiency by saving
energy, money and improving tank life
• Enhanced -flow brass drain valve
• Temperature and pressure relief valve
included
• HUD certified for manufactured
housing and modular construction
• Low lead compliant
Warranty
• 6-Year limited tank and parts
warranty'
• With ProtectionPlus" the 6-year limited
tank warranty becomes 10-year
'See Residential Warranty Certificate for complete
information
Units meet or exceed ANSI requirements and have
been tested according to the AHRI Operations
Manual and D.O.E. procedures. Units meet or
exceed the energy efficiency requirements of
NAECA, ASHRAE standard 90, CC Code and all
state energy efficiency performance criteria.
Residential Electric
Water Professional Classic Water Heaters
Professional Classic
19.9 to 55-Gallon Capacities
240 Volt AC/Single Phase
Double and Single Element Models
Electric
!r'9 crxiineo
See specifications chart on back.
PRIMED IN usA 08117 wP FORen No. PROE RH N Rev. 6
10
The new degee of cwnforY
Professional Classic" Specifications
Residential Electric
Water Professional Classic Water Heaters
DESCRIPTION
FEATURES
ROUGHING IN DIMENSIONS(SHOWN
IN INCHES)
ENERGYINFO.
T
Y
P
E
NOMINAL
GALLON
CAPACITY
MTEO
GALLON
CAMCNT
MODEL
NUMBER
UEF
RRSTHOUR
RATMO
GPM.
EF
FIRSTHOUR
MTNG
O.P41.
RECOVERY
IN ORR
W )RISE
TANK
HEIGHr
A
HENINTTO
WATER CONN.
a
OMMETEN
C
APPnOx.
eHIPM..
0as4
ENERGY
FACTOR
UNIFORM
ENERGY
FACTOR
NER
Tell
30
27
PROE30 T2 RH951
48
48
21
47-12
50-3/6
19-1/4
92
0.95
0.92
Tall
40
36
PROE40 T2 RH951
55
57
21
60-3/4
63-5/8
19-1/4
109
0.95
0.93
Tell
50
45
PROE50 T2 RH95'
63
67
21
58-5/8
61-5/8
20-1/4
121
0.95
0.93
Tell
55
55
PROE55 T2 RH941
67
71
21
57
59-W4
22-1/4
128
0.94
0.92
Mad.
SO
27
PROM M2 RH951
45
44
21
37-1n
40-M
2OA14
92
0.95
0.92
Med,
40
36
PROE40 M2 RH951
54
55
21
48-1/4
50-W
20-1/4
106
0.95
0.03
Med.
50
45
PROM M2 RH951
62
1 65
1 21
1 48
1 50-12
1 23
132
0.95
0.0
Short
19.9
MOM 82 PH
21
31-12
31-1/2
17
62
Shon
28
25
PROE28 S2 RH95
43
42
21
30
31-1/8
23
95
0.95
0.92
Shod
30
Z7
PROE3052 RH95 B"
43
42
21
MAIM
32
19-3/4
95
0.95
0.92
Short
S6
33
PROE36 S2 RH95
46
45
21
31-12
33
24-1/4
118
0.95
0.92
Short
38
35
PROE38 S2 RH95 B--
54
55
21
31-12
32-578
23
108
0.95
0.93
Shed
47
43
PROE47 S2 RH95 B--
54
55
21
32
34
26-1/4
149
0.95
0.93
Uniform Energy Factor. Eergy Factor and rated gallm oapa ity based on Department of Energy (DOE) requirements.
t System Sentinel optional. Add ECl to the end of the model number. System Sentinel not available on single
element models, avallable on dual element models only. System Sentinel not available In excess of 5 kW on
208 V models.
-Water heater dourfunns poor to installing iLsubtlm blanket Ihat is nnutled with water healer.
• Heaters funneled with standard! 240 wtt AC, single phase non -simultaneous wiring, and 4500 wa t upper and comer ruling
elements.
• 9 heating elements of different wattages than those shown are demanded by zone requirements, they must be
.P.4fically requested.
• Sn9c element stories available on special order (6000W max.). Suirstituto-1"for -F it model number.
•Special Winlg Options- A mrited number of special wirng options am av ks,la. Consult factory for price and avw1aMity.
• All models equipped with heat baps.
Recovery= wattage2.42 x IMP. rise °F.
Example: 450OW =21 GPH
2.42 x 90
Recovery wkule8orls used are based an 4500 watt eienvnts used If non s4rweanepts operation.
HOT
RELIEF VALVE
CONNECTION
•COLD
WATER
ROD
WATER CONNECTIONS ALL 3/4" N.P.T.
In keeping with its policy o/continuous progress and product improvement. Rheem reserves the nghf to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100
Roswell, Georgia 30076 • www.dleem.com
PRINTED IN USA Cut? WP FORM NO. PROE aR N Rw.6