Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 o74 30f4m. E.. BCIs Home I-Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications I Contact Us BCIS Site Map Links Search FI lido I � ; Product Approval FL15210:1 6 8 OPAGUE FIBERGLASS SINGLE DOOR IN OS product Approval Menu>Product or Application Search>Application List>Application Detail 91�yt9�11 i?#NMi�. 1 f FL# FL15210-R6 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 (440)969-9773 Ext 16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 16 ronoconnell@plastpro.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. . the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan J.King,P:E. 21 Validation Checklist-Hardcopy Received Certificate of Independence FL15210 R6 COI (a)Certificate of Indeoendence.Ddf Referenced Standard and Year(of Standard) Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 1998 ASTM D638 2003 ASTM E1300 2004 ASTM E84 2005 ASTM G26 1995 G 155 2005 TAS 201,202,203 1994 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZ I Q... 6/5/2019 Florida Building Codd Online Page 2 of 4 Equivalence of Product Standards Certified By Florida Licensed,Professional Engineer or Architect FL15210 R6 Eauiv (a)Eauivalency of Standards.odf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/13/2017 Date Validated 09/18/2017 Date Pending FBC Approval 09/20/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 15210.1 a.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door- Grain/Rustic/Mahogany Series 0 Inswing/Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.1 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.1.odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15210.2 b.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series 0 Sidelites-Inswing/Outswing(OX or XO;OXO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes. FL15210 R6 II (b)Inst 15210.2.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.2 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.2.0f additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.3 c.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Double Door with or without Grain/Rustic/Mahogany Series 0 Sidelites-Inswing/Outswing(XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.3 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.3.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.4 d.Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Single Door- Grain/Rustic/Mahogany Series O Inswing/Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)-Inst 15210.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:!See.INST 15210.4 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.4.odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. i 15210.5, e.Smooth/Wood Grain/White Wood 68"Impact"Glazed Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series 0 Sidelltes-Inswing/Outswing(OX or XO;OXO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL15210 R6 II (b)Inst 15210.5,r)df Approved for use outside HVHZ:Yes .Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports I https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ I Q... 6/5/2019 I Florida Building Code Online Page .3 of 4 Other:See INST 15210.5 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.5.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.6 rGaing/F mooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Double Door with or without ustic/Mahogany Series O Sidelites-Inswing/Outswing(XX; OXXO-Configurations) erlass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.6 for Design Pressure Ratings,any FLIS210 R6 AE (b)Eval 15210.6.odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15210.7 g.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door-Outswing(X- Grain/Rustic/Mahogany Series O Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL15210 R6 II (b)Inst 15210.7.0f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.7 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.7.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. - i 15210.8 h.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Outswing(OX or XO;OXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.8.odf Approved for use outside.HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.8 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.8.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.9 i.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series 0 Sidelites,-Outswing(XX;OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL15210 R6 II (b)Inst 15210.9.0f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.9 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.9.odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. i 15210.10 j.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door-Outswing(X- Grain/Rustic/Mahogany Series O Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL15210 R6 II (b)Inst 15210.10.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.10 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.10.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.11 k.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Outswing(OX or XO;OXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:-Yes FL15210 R6 II (b)Inst 15210,11.0f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.11 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.11.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. i 15210.12 I.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Double Door with or without Grain/Rustic/Mahogany Series 0 Sidelites-Outswing(XX;OXXO-Configurations) Fiberglass Door i https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yV V.KJZ 1 Q... 6/5/2019 Florida Building Code Online Page 4 of 4 Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.12.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact;Resistant:Yes Created by Independent Third Party:Yes Design!Pressure:N/A Evaluation Reports j Other:See INST 15210.12 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15230.12.Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.13 m.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Surface Grain/Rustic/Mahogany Series O Bolts-Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.13.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.13 for Design Pressure Ratings,any FL15210 R6 AE (b)Eva[15210.13.odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars, 1 15210.14 n.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Double Door with Surface Grain/Rustic/Mahogany Series O Bolts on Active Door panel-Outswing(XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.14.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.14 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.14.Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.15 o.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door utilizing the Grain/Rustic/Mahogany Series O WINDSERT"'an operational window insert-Outswing(X- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6' II (b)Inst 15210.15.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.15 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.15.1)df additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. I Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Coovrinht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Sectlon 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the'public.To determine If you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: ® ® RE M Credit C&d SaM_ https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=w6EVXQWtDgv3yVVKJZI Q... 6/5/2019 i i f R W R W Building Consultants, Inc. B Consulting;and Engineering Services for the Building Industry C P.O.Box'230 Valrico,FL 33595 Phone 813.659.9197 iFlorida Board ofProfessional Engineers Cenincate,of Authorization No.9813 Pi-oduct Evaluation / Date. Atigust 10,2017 Product Sub Category Manufacturer Product Name Category 1Plastpro,Inc.. Smooth/Wood.Graln i Whitewood Grain Exterior Swinging W Exterior Door 5200' .Century Blvd. 'Rustic I Mahogany Doors Assemblies Los-Angeles,CA 90045 Serles"O Fiberglasstoor Phone:440.969.9773 Inswing/Outswing-"Impact' Scope: Product Evaluation report:issued by R'.W-Building Consultants, Inc.&-Lyndon F..Schmidt,P;E.(System ID#1998)fogy Plastpro Inc.,based on Rule Chapter No.61 G20-3, Method 1 D of the State ofFlodda Product Approval,Departmentof Business&Professional Regulation. RW Building Consultants-and Lyndon,F.Schmidt,P.E.do,not have nor:will acquire financial interest:in the company manufacturing or distributing the product-or in any.oiher entity involved in the approval'process-,of the productnamed herein. Limitations: 1.'This roduct has been'evaluated and is in Compliance with the=6th.Edition 2017,Florida Building,Code FBC structural_re uirerrients including the;"High Velocity Hur(icane:,Zone".: 2. Product anchors shall be as listed'and:spaced,as shown on details.Anchor embedment to base material shall be beyond-wall dressing. or stucco. 3. When used in the"HVHZ"this product complies with Section 1626,of the Florida Building Code and does not require an impact' resistant covering. 4. When used in areas outside;of the"HVHZ"requiring wind borne:debiisprotection this product complies with'FBC Sections 1609,1::2& R301.2.1.2 and does not require an impact resistant covering.This product meets,missiie level it"and includes Wind Zone 4as defined in AS E 1996 and FBC.Sections 1609.1.22&.R30.1.2,1,2.1. 5. For2xstud framing construction,anchoring of.these units,shall be'th'e same as thatshownfor 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL-15210.1 require further, engineering analysis by a licensed engineer or registered,architect. 7..Outswing configurations meet water infiltration:requirements for"HVHZ". All other configurations do not meet the water infiltration requirements for the"HVHZ",and must be installed only in non-habitable areas or-at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less'than 45 degrees. 8. See drawing FL-1521.0.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing-Lab oratory Signedty TEL 01390365 TAS 201-94,202-94&TAS 203-94 Testing Evaluation Lab.,Inc. Lyndon F Schmidt,P.E. TEL 01391846 TAS 201-94,202-94'8,TAS 203-94 Testing EvaluationLab;,Inc. William<Sheiton,P.E. ETC-05-255716778.01 ASTM D 635-98,638-03,1929-96&2843=99= ETC,Laboratories Jo"seph.L.Roldan,P.E. ASTM G.26-95 ETC-06-255-17412:0 'ASTM,E 84-05 ETC-Laboratories Joseph,L Doldan,.P.E'. ETC-07-209-19303.0 ASTM'D 635-98,:638:03,1929-96'8 2843-99 ETC.Laboratories Ben,Meu"nter 2. Drawing°No. Prepared by Signed&;Sealed by No.FL45210.1 RW Building Consultants,Inc.(CA#9813) Lyndon F:Schmidt,P.E. 3. Calculations 'Prepared by Signed&Sealed by Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon'.F.Schmidt,P.E 4. Quality Assurance y g Certificate of Participation issued,b National Accreditation,and Management C Institute,certifying Ghat Plastpro I Inc.is manufacturing products wtthip a uali ♦ �,� �G'E N S•, . is assurance program that complies'.wtth ISO/IEC 17020 and Guide 53. No 43409 A r STATE OF Lyndon F.Schmidt,P.E. Fl PE No.4309 M1/2o Sheet l of t 815y8t�� plastpro , %��=�M 5200 W. CENTURY BLVD. o;N V'-. <i0ro LOS ANGELES, CA 90045 '�� *'P' 37.50"MAX.OVERALL �tu�N o n m i - -- Smooth-/--Wood Grain / White Wood Grain FRAMEWIDTH - m, a–O I'v a Z o?U. Rustic/Mahogany �� �ck` e Na 9 o v o Series O Fiberglass Door 4 . INSWING/OUTSWING ®. oa 'IMPAC]"' U, W 20 GENERAL NOTES z` ? o j 3: o 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Buldng Z ?o o Z Code (FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). O �E m 0 2. Product anchors shall be as fisted and spaced as shown on details.Anchor embedment to base M I 5 w N w material shall be beyond wall dressing or stucco. w aIn 3. When used in the"HVHZ"'this product complies with Section 1626 of the Florida Building Code and X of o does not require an impact resistant covering. a a a 4. When used in areas outside of the"HVI-IT'requ'cing wind�bome debris protection,this product j w >>m S complies with FBC-Sections 1609.1.2&R3012.1.2 and does not require an impact resistant covering. O O E This product meets missile level"D"and includes Wind Zone 4 os defined in ASTM E 1996 and FBC N �m Sections 1609.1.2.2&R3012.12.1. - a0 � 5. For 2z stud construction,anchoring of these units shall be the some as That shown for 2x buck masonry $ s construction. w w o 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. d � 00 7. Outswing configurations meet water infiltration requirements for"HVHT'.All other configurations do not meet the water infiltration requirements forthe'TiVHT'and must be installed only in non-habitable EL n- areas or at habitable locations protected by an overhang or canopy such that the angle between " z the edge of canopy or overhang to sill is less than 45 degrees. m N A Q f TABLE OF CONTENTS ^ o SHEET# DESCRIPTION SHEET# DESCRIPTION m 1 Typical 8evations,Design Pressures General Notes 7 Horizontal&Vertical Cross Sections(Direct to Masonry) MAX DESIGN PRESS[7RE{PSF] & N'Z " 2 Door Panel Details 8 3-point lock details CONF#GURATfON FRAME —02116112..... Z E 3 Horizontal&Vertical Cross Sections(2X Buck) 9 3-point lock details Li1l19ENSJON PC?S171t/E .NEGATIt/E= SCALE N.T.S. 4 Horizontal&Vertical Cross Sections(1X Buck) 10 Buck and frame anchoring M.MI JK m s 5 Horizontal&Vertical Cross Sections(Direct to Masonry) 11 Components X 37.5"x 82.0" +7$,0 -75.0 auc.BY: LFS 3 E 6 Vertical Cross Sections(Thresholds) 12 Bill of materials onnwwc NO - See sheets 2 for hardware design pressure limitations N 5 FL-15210.1 a mm .1 oe 12 Ilk 0.7" 2.6 •:.. e• EXTERIOR 0.4" '•n -•�•r 0.4 I �=//�/�'••� 1�^.6 11 .C .... J NO SID ro o n m z INTERIOR TOP RAIL \�'` V oto m °c W CAP(PVC) LATCH STILE(LVL) V U� Q't >o OIL HINGE STILE(LVL) CAP(PVC) (COMP.) a in a a c 1 HORIZONTAL CROSS SECTION E $? 2 _ `W cl o° 3NCI: at J 35.75'MAX O.A. 50 WIDTH 6. •?p: z$ o d 00Ln > w D Ln m z v Rm O ® ® Y O ~ 2 o a p NARDWARETA8IE a a MAX.DESIGN INTERIOR EXTERIOR m MANUFACNRER MODELS ..r.. ... ;PRESSURE' .S v v E KNOB: SIGNATURE SERIES = KWIKSET DEADBOLT. SIGNATURE SERIES(980) -75- FOAM CORE 8 d (POLYURETHANE- 0`! O SCHLAGE KNOB: •P SERIES(FST) {75 1.9 PCF MIN.)- ,e' N N DEADBOLT: V SERIES(860/62) N Z9 00 O c h SEE HARDWARE TABLE PAMEX LEVER: FL3B SERIES - e•'• rn DEADBOLT: FD7 SERIES ±75 % 4: m U) �i - 00 HOPPE MULTIPOINT LOCK: HIS90M 3-POINT TONGUE {50 ,-•• �i FIBERGLASS SKIN e.•: _ a Q SEE HARDWARE TABLE (0.125-Ml N.THK.)�` a � ENDURA MULTIPOINT LOCK: iRILENNIUM 3000(3-PT) {75 F . . a See sheets 5 and 6 for multipoint lock details. ;•,;•`.;.; T ,�,o BOTTOM RAIL z g (COMP.) 2 _i z rz DAm 02116112 z a 20 a'•'E N.T.S. 40 DOOR PANEL DWO.er: JK m' fibe glas Plastpro 2 VERTICAL CROSS SECTION CHK.Ery- IFS FF g - . 2 DRAWING NO-- FL-15210.1 O_FL-15210.1 0 N sNa:r 2 or 12 u I R; lents\Plastpro,Inc PERMANENT\A-Fladda Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and GlazedIC-Dmwings\FL-15210(2017ffL•I5210.1-6,dwg,3.1 9 1 A 70� v z g= 0 Car N U3 O l r r r' n n O .H V W V 01—. a� W 3.n � , s� _Z d V z P �a N O N o W W WN Q Z T W O L"Ca IT! M ' o 2 0 - Q V A V N N N A N W N c: O o 30 =0 1101 .M V v zy o O r `� ry V O. n N r•• V to N n S y T th O Z ' v v 8 i v Co hl 0-1 m , o v , �O a N .m m mY.It ° 0 a o 0.15'C-SINK n r o� S.CNMi'��/, (nP) v.•"uGElle���''� 1-1/4"MIN. EMB,(TYP.) L No.43409 PRODUCT: D...m nt. Proparod By: �1 T< F PLA57PR0 INC. LY F. Schmidt) 'i, `s•.�Wi10�. N FIBERGLASS DOOR P.E. No. 43409S/QA� `�� IW N o z\ //111111111\t $ N y 2 7 24 17 UPDATE 70 6TH ED. 2017 FB, JK PART OR ASSEMBLY: (,Qn'/BUILDING CONSULTANTS, INC, IN p in\ 1 3 9 15 UPDATE 70 5TH ED, 2014 FIJK tJ L_I/I/ P.O. Boz X230, Valrico, FL 33595 N NO DATE BY HORIZONTAL & VERTICAL VV Phone No.: 813.659.9197 REVISIONS CROSS SECTIONS (2X BUCK) FBPE CA: No..9813 0 2171 6 R.W.BUILDING CDNBULTANTB ING. 1. R:\qi cots\Plastpro,Inc PERMANENT\A-Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glazed\C-Drawings\FL-15210(2017)\FL-15210.1-6.dwg,4.1 m d ° e A� a o�x F. o O fC) j te o O g N Z I0 I0 A O A N 0-S O � Or y �? a O .°... < v v m m o $ n OsT 0 o^. x� ° Or ®' ` n V o n Z m ° °v N n ``111111111//!//' 1-1/4 MIN. ```��v(�SClily/O�ii'i EMB.(TYP,( / ? V No.43409 ' Q PRODUCT: Document. Prepared By: �� it PLASTPRO INC. Lyndon F. Schmidt �ii� �ORICw raj; 1 i'•........... FIBERGLASS DOOR P.E. No. 43409 0 fill -on N'' y pl 2 7 24 17 UPDATE 70 6TH ED. 2017 FBC JK PART OR ASSEMBLY: BUILDING:CONSULTANTS, INC. Ip (n 1 3 9 15 UPDATE TO 5TH ED, 2014 FBC JK / P.O. Box'230, VGIrICG, FL 33595 N N NO DATE BY HORIZONTAL & VERTICAL vY Phone No.: 813.659.9197 REVISIONS CROSS SEC7(ONS IX BUCK) FSPE C.A. No. 9813 QJ 201 6 R.W.BU—ING CON—ANTS INC. 1 r I R:\Clients\Plastpm,Inc PERMANENT\A-Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glazed\C-Daw4ngs\FL-15210(2017)\FL-15210.1-6.dwg,5.1 - O rn Uf r e.G .< Oma= ae. ° to O gg �o �n 3. N 7 S .. - O0 P3 . O !_ �j0 A N V 3 T l � � 'L 0 A rr N 0!q = 3.7 N V N !D�Z o�a for m� V Am . Z 3 0 Z o T O rnX T O m C7 .Z7 A N W G °o 0- c=T r ° DoH ` ° v • E Z ? I� N 1-1/4"MIN. ``tt\tNlllflp7�'' - EMB.)TYP,) �.� F,3CH . �.� V.• eo�.T��% No.43409 PRODUCT: Documante Prop—d By: �� q o PLASTPRO INC. Lyndon F. Schmldtl �i�� s'• OR10�`.��G````� - = N FIBERGLASS DOOR P.E. No. 43409 4 0 r- y rn 2 7 24 17 UPDATE TO 6TH ED. 2017 FBC JK PART OR ASSEMBLY: BUILDING,CONSULTANTS, INC. UPDATE TO 5TH ED. 2014 FBC JK �/f�P,O. Box�230, Valrlco, FL 33595 y HORIZONTAL & VERTICAL CROSS vv VV ro w NO DATE SECTIONS DIRECT TO MASONRY) Phone No.: o. 9859.9197 REVISIONS FBPE CA No. 9873 2016 R.W.BUILDING COINS -TANT8 IND. • R:\Clients\Plastpro,Inc PERMANENTNA-Florida Product Approvals\FL-15210 HVHZ Flberglm-Impact Opaque and Glazed\C-D2wings\FL-15210(2017)\FL-15210.1-6.dwg,6.1 Orn � s o 0 ,� C O O y ° O N I � T c g O m n , — m m n ° m w N ° zr T °p a� on � �O aO g m Z ° .No 0 m 1-IINMIN. EMB.(TYP.( o , w w m on $ A o n e ° a00 0 H ° N T n ° Z ° ' e � , m e Z m co 14 a G 7` '• Na.43409 PRODUCT: Document.Prepared ey:-I 0. PLASTPRO INC.FIB RGLASS DOOR P Ea No. 43409. SchmIdt ��i,,p�01dA{.1G��`` o �JJ 2 7 24 17 UPDATE 70 6TH ED. 2017 FBC JK PART OR ASSEMBLY: @� BUILDING 'CONSULTANTS, INC. Ip x tq y 1 3 9 15 UPDATE 70 5TH ED. 2014 FBC JK 4Y P.O. Boz'230, Vairico, FL 33595 N w NO DATE gY VERTICAL CROSS phona No.: 813.659.9197 REVISIONS SECTIONS (THRESHOLDS) FBPE C.A. No. 9813 0 2D 1 6 R.W.allILDING CONSULTANTS INC. 'R;\CII nts\Plastpro,Inc PERMANENT\A-Florida Pmduct Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and GW:ed\C-Drawings\FL-15210(2017)\FL-15210.1-6.dwg,7.1 V v MAX. C MIN. .2 v � N jn z ° �O r .o O m 3 O c:m A $ z $ � 1-1/4"MIN. p l� EMB.(TYP.) IA A A O`' too z n T `or y 'PO A0 O a� H o T n 1.25' Q r) 3 MIN. -Z O z 3 2,25' 1.S'MAX. z n 1.5' MAX. Oo 20 z v 17 3.7 N m 3 C,o MIN, Om Z v :3 y n f 0 t" ° `r l;17 ° �o - J0 O � m 3 nn (l $ �i Cr Z0 =j. 1-1/4"MIN. a to EMB.(fYP.) o08 40 Q z N 0 A A • H • o=-Z ^ Z $ 3 Z o V A O 2 N 3 to�O 71 cf9i 10 r A M N. ``t11tt III1 fj2j co M nz 4.26'— 1.5'MAX. / `..� •�ycFliaF .�' •, Q / :•• No.43408 z x g PRODUCT: Daaumante Prepared ley: -• •• `` PLASTPRO INC. Lyndon F. Schmidt i,�i.�s' �'•�•`��� IV I z N FIBERGLASS DOOR P.E. No. 43409 o Ln `' 1 2 7 24 17 UPDATE TO 6TH ED. 2017 FBC JK PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. IN y c- tJ NO DATE5 UPDATE TO 5TH ED. 2014 FBC JK HORIZO AL & VERTICAL RU(P.O. Box 230, Valrlco, FL 33595 SECTIONS DIRECT TO MASONRY) Phone No.: o. 98139197 REVISIONS FBPE C.A. No. 9813 ®201 2 F.W.S.--Coreulrwnre INC. ' I I R:\Clients\Plastpm,Inc PERMANENT\A-.Florida Product Approvals\FL-15210 HVHZ Rberglass-Impact Opaque and Glazed\C-"Drawings\FL-15210(2017)\FL-15210.1-6.dwg,8.1 Z C D OVERALL HEIGHT y HANDLE HEIGHT M 0 0 a• 0 N O C N M 0 M D A , Gn H 10.04" �{ , e \ � N W 4.63"�{ �+ O_ 3.63 I ��`0.1 r � �O w; o-Z Q o � o M 00 ocz� ox o M.n b N 3> �8.82"— —�{ to ® 0.1" R m - v zn n z z In n T m 3.61" N rs `\t1\111 nIH2gi w 43.09" G No.43409• i Q PRODUCT: Doaumente Prepared 9y:'� N FIBERGLASSGDOOR P E. No F 43409 tdti � � ICo ) "N y 2 7 24 17 UPDATE TO 6TH ED. F2017T FBC JK PART OR ASSEMBLY: CQ BUILDING I CONSULTANTS, INC. IO X !A 1 3 9 15 UPDATE TO 5TH ED. 2014 FBC JK 3—POINT LOCK DETAILS YY P.O. Box:.230, Volrico, FL 33595 _ N N NO DATE BY Phone No.: 813.659.9197 REVISIONS FBPE C.A. No. 9813 0 SD1 2 R.W.8—01—CONSULTANTS INC. ' I R:\Gents\Plastpro,Inc PERMMENT\A-Florida Product Approvals\FL-15210 HVHZ Flberglam-Impact Opaque and Glazed\C-Drawings\FL-15210(2017)\FL-15210.1-6.dwg,9.1 I i O C - D o Z n Z F C 3 N rnm� A y '0 Do . A O N V R p• Am 3 m O 24.25' 23.0" 1gUnnrgr77 /r No.43409 $ PRODUCT: Document. Pmpomd-By: 2•`� B PLASTPRO INC. Lyndon F. Schmidt �ii� RO..O�•' I� N FIBERGLASS DOOR P.E. No. 43409 2 7 24 17 UPDATE 70 6TH ED. 2017 FBC JK PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. Ip x h 1 3 9 15 UPDATE 70 5TH ED. 2014 FBC JK 3—POINT LOCK DETAILS P.O. Box 30, Valrico, FL 33595 N N NO DATE BY Phone No.: 813.659.9197 REVISIONS FBPE C.A. No. 9813 201 2 R.W.BLIILDIND tiON—A—IND. DIRECT TO MASONRY JAMB(TYP.) O * L i 4" 49/16"JAMB P (SEE SHEEP 7) \\'� d2l0 (TYP.) A, (TYP-) U * a Z sig ::)> ///�••............. J 7 Ot `\\ O n m z SEE HINGE L 2X BUCK O N D TYP.HEAD , DETAIL(TYP.) z_x z v _ &JAMBS o G 1X BUCK �f�I \q g 'a 0 0 W ` 7 DIRECT TO _ o `I a to a 'm a a G. MASONRY a MASONRY D MASONRY s d ? 7 OPENING OPENING TYP.HEAD g &JAMBS S a FRAME z of _ LL 2X BUCK _49/16"JAMB M O Z� 2X BUCK �N ~ 6 9/16"JAMB N �� e v a DIRECT TO ' m o Z;) MASONRY O JAMB(TYP.) O cc ` (SEE SHEET 7) of m a n Ic o ( ADA SILL t; _ ONLY E . " - ' .• N N L sBUCK ANCHORING STRIKE JAMB FRAME ANCHORING HINGE JAMB W W O Masonry construction rn 00 a CONCRETE ANCHOR NOTES: DIRECT TO 1.Concrete anchor locations at the comers may be adtusted to maintain the min. DIRECT TO MASONRY M DIRECT TO o 0 edge datance to mortarjoints. MASONRY M j n 2 Concrete anchor locations noted as MAX.ON CENTER'must be adjusted to M MASONRY ? maintain the min.edge distance to mortar joints,additional concrete anchors '28 1X BUCK 1X BUCK G 1XBUCK G ^w i may be required'to ensure the MAX.ON CENTER'dimension are not exceeded. G 9 9 a Lu 3.Concrete anchor table: 2X BUCK L r e n� o :MIN CLEARANCE MIN.CLEARANCE 2X BUCK 5S 58 2X BUCK 2X BUCK L M ANCHOR ANCHOR MIN 11 a' a ;TYPE 'SIZE EMBEDMEM TO MASONRY TO ADJACEM-: 11 Z a -EDGE-,;.. _ANCHOR :'. 1X BUCK 11 DIRECTTO wTe 02116112 i TaITW t/r ta/4• z" a" M MASONRY 11 11 DIRECT TO 11 ❑ � N.T.S. ° Etco t/4" 1-1/4" t" a" MASONRY G 1X BUCK DWG.BY: JK M ULTRACON ITw o 3116• 1-1/4- AS SHOWN 1-t/s" 27 58 2XBUCK aix NY: LFs Q TAPCON �4 DRAWING NDS 1_WOOD SCREW INSTALLATION NOTE: HINGE DETAIL HINGE DETAIL FL-15210.1 N Maintain o minimum 5/IP edge distance,I"end distance,&T'o.c.spocing of LATCH d DEADBOLi DETAIL wood screws to prevent the sprihing of wood. 1f15Wing OutSwln9 N s¢Er 10 of 12 I R:\Clil nts\Plastpm,Tnc PERMANENT\A-.Florida Product Approvals\FL-15210 HVH2 Fiberglass-Impact Opaque and Glazed\C-Drawings\FL-15210(2017)\FL-15210.1-6.dwg,11.1 I 1.4" 1.75' 1.25" a w N c O 0O �O CL a p ° Z 2 tn O = = Z 6 6 6 6 , ---IL zs" I 1.75' w �+ V to T'1 to Q O ° O D INN, 3� � v f 7�0 to S p O = 3 x 6 6 6 6 ^� 1.3" 1.4- 0.65" V 1.25" o.a os�z oa F 0.15" N ? vv So F o0 K a N O O ol D T P V 0.937' b f— —F .7S' f--- 0.75' m O gNg O 25 • N T No.43409 PRODUCT: Documents Prepared By: PIASTPRO INC. Lyndon F. Schmidt /Qs'•� DF,•'O\��� c'S N FIBERGLASS DOOR P.E. No. 43409 ///js�ONAL D '' y 2 7 24 17 UPDATE TO 5TH ED. 2017 FBC JK PART OR ASSEMBLY; BUILDING CONSULTANTS, INC. N UPDATE TO 5TH ED, 2014 FBC JK - ��/r�P.O. Box;230, Valrico, FL 33595 IN N NO DATE BY Pp Phone No.: 813.559.9197 REVISIONS COMPONENTS FBPE C.A, No. 9813 P'i. 201 2 R.W.BUILDING CONBULTANTS INC. I I 6 BILL OF MATERIALS REM# DESCRIMON MATERIALZ` n A 1X BUCK SG>=0.55 WOOD '�4� Z �`r°Q� 6m B 2X BUCK SG>=0.55 WOOD C I/4"MAX.SHIM SPACE D 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 'I' i 10\\\\ 0°m 0 E MASONRY-3,000 PSI MIN:CONCRETE CONFORMING TO ACI CONCRETE � a u N z0 5 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 \9 ; Em om o0 G 3/16"x3-1/4"PFH ITWCONCREfESCREW STEEL Q� a y+° 6 I 114'X 1-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL r m d a J 1/4'X 3-3/4"PFH ELCO OR RW CONCRETE SCREW STEEL ` 0 cs K 1/4"X2-1/4"TfW CONCREfESCREW STEEL vZ L #10 X 2-1/7'PFH WOOD SCREW(1.1S'MIN.EMBEDMENT) STEEL o Eli M 3/16!'X 2-1/4"ITW CONCRETE SCREW STEEL N 3/16"X 2-3/4"ITW CONCRETE SCREW STEEL P 1 XX 2-1/4"PFH ELCO CONCRETE SCREW STEEL cn 1 POLY FIBER JAMB COMP./VINYL Z0 Q 2 FINGER JOINTED PINE FRAME WOOD oy 7 WEATHERSTRIP FOAM �S 0 8 DOOR BOTTOM SWEEP VINYL 3w N o 9 4"X N'BUTT HINGE STEEL 11 #9 X 3/4"PFH WOOD SCREW STEEL a� " 22 3 POINT"TONGUE"MULTIPOINT LOCKSET(Mfg.BY HOPPE) STEEL U I m m � � o 23 MULTIPOINT STRIKE PLATE(TONGUE SYSTEM) STEEL 0 25 LATCH AND DEADBOLT STRIKE PLATE(TONGUE SYSTEM) STEEL a a 27 LATCH STRIKE PLATE STEEL m lu 28 DEADBOLT STRIKE PLATE(SECURITY) STEEL 0 29 ADA THRESHOLD ALUMIn In 30 OUTSWING THRESHOLD - ALUM/WOOD e 31 OUTSWING THRESHOLD ALUM/WOOD N N g 32 OUTSWING THRESHOLD ALUM/WOOD o 33 OUTSWING THRESHOLD ALUM/COMP Lo 34 OUTSWING THRESHOLD ALUM/WOOD m in 36 INSWING THRESHOLD ALUM/COMP o 37 INSWING THRESHOLD ALUM/WOOD ~ 38 INSWING THRESHOLD ALUM/COMP o 0 >> 40 OR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS z 55 #10X1-1/7'PFHSCREW STEEL n � 57 BACKING PLATE STEEL N m a 58 #8 X 2"PFH WS STEEL z 60 MULTIPOINT STRIKE PLATE STEEL z 62 ENDURATRILENNIUM3000LOCKASSEMBLY STEEL c'�Z DAT:02116112 i sCUE: N.T.S. ° c Mr,er: JK m' CHK BY.. LFS 3 'S DRAWN°N°.: FL-15210.1 0 nsHm 12 of 12 d