Loading...
HomeMy WebLinkAboutDrawing 0069 RQ;Q --------------------------------- ------------------------------ SEP ®6 2099 Permitting Department St. Luefe County kgcq 36" X 80" File Copy REPLACE DOOR IN 1 OPENING ONLY. SVIEWiD FOR � u NEW DOOR TO BE IMPACT RESISTANT- C® E COMPLIANCE HURRICANE SHUTTERS NOT REQUIRED. ST. LUCIE COUNTY B®CC ' OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 1 36 1 80 20.00 1 4 48.0 1 -57.1 FL16708.1 65.0 1 -65.0 FRONT ENTRY-LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. r ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. I i LESS THAN 30%OF STRUCTURE'S VALUE.NOT A RENOVATED BUILDING.EXEMPT FROM 2017 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 87 FT 4 IN I ROLLAN CONDO UNIT 9490 S. OCEAN DRIVE, UNIT 315 DOOR REPLACEMENT PLAN JENSEN BEACH, FLORIDA