HomeMy WebLinkAboutDrawing 2 72" X 80" 51" X 80" 1 REPLACE DOOR&SIDELIGHT IN 1 OPENING &DOORS IN 1 OPENING ONLY. NEW DOORS&SIDELIGHT TO BE IMPACT RESISTANT- SHUTTERS NOT REQUIRED. RECEIVED _0 SEP 11 ?159 ST. Lucie County, Permitting � OPENING PRODUCT DESIGN OO E 111VG SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. , MOTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 5 80 28.33 4 36.1 -39.3 FL16674.6 50.0 -50.0 FRONT ENTRY-LSMI 2 1 72 80 40.00 4 34.4 1 -37.6 FL16708.4 65.0 -65.0 FAMILY ROOM-LSMI REPLACE EXISTING DOORS&SIDELIGHT AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS&SIDELIGHT. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR&SIDELIGHT FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH#10 WOOD SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. LESS THAN 30%OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 12 FT 10 IN BOKOR RESIDENCE 5909 CASSIA DRIVE DOOR REPLACEMENT PLAN FORT PIERCE, FLORIDA