HomeMy WebLinkAboutProduct Approval R W R- W Building Consultants, Inc. RECEIVED
B Consulting and Engineering Services for the Building Industry 5 E P 10 2019
CP.O.Box 330 Vahico.Ft.33595 PhoneSI3.b59.9r97
C
Florida Board of Professional Engineers Certificate of Authorization No.9813 ST. Lucie County, Permitting
Product
Category Sub Category nuf _t er [productName
Swinging Plastpro,lnc. Smooth t Wood Grain t White Wood Grain
Exterior Exterior Door 5200 W.Century Blvd. Rustic!Mahogany
Doors Assemblies Los Angeles,CA 90045 Series O.Fiberglass Door
Phone 440.969:8773 inswinglOutswing-"Impact"
Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for
Ptastpro Inc.,based on Rule Chapter No.61 G20-3,Method 1 D ofthe State of Florida Product Approval,Department of
Business&Professional Regulation.
RW Building Consultants and.Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company
manufacturing.or distributing the product or in any other entity involved in the approval process of the product named
herein.
Limitations:
1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements
including the"High Velocity Hurricane Zone".
2- Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in the"HVHZ"this product complies with Section 1626 of the Florida.Building Code and does not require an impact
resistant covering.
4. When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&
R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as
defined in ASTM E 1996 and FBC Sections 1609.1.2.2&R301.2.1.2.1.
5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction.
6. Site conditions that deviate from the details of drawing FL-15210.1 require further engineering analysis by a licensed engineer or
registered architect
7. Outswing configurations meet water Infiltration requirements for"HVHZ'. All other configurations do not meet the water infiltration
requirements for the"HVHZ'and must be installed only in non-habitable areas or at habitable locations protected by an overhang or
canopy such that the.angle between the edge of canopy or overhang tc.sill is less than 45 degrees.
8. See drawing.FL-15210.1 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard Testing Laboratory Signed by
TEL 01390365 TAS 201-94,202-94&TAS 203-94 Testing Evaluation Lab.,Inc, Lyndon F.Schmidt,P.E.
TEL 01391846 TAS 201-94,202-94&TAS 203-94 Testing Evaluation Lab.,Inc. William Shelton,P.E.
ETC-05-255-16776.0 ASTM D 635-98,638-03,1929-.96&2843-99 ETC Laboratories Joseph L.Doldan,P.E.
ASTM G 26-95
ETC-06-255-17412.0 ASTM E 84-05 ETC Laboratories Joseph L.Doldan,P.E.
ETC-07-209-19303.0 ASTM D 635-98,638-03,1929-96&2843-99 ETC Laboratories Ben Meunier
2. DMAtINo. Prepared bK Signed&Sealed by
No.FL-15210.1 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E.
3. Calculations Prepared by Signed&Sealed by
Anchoring RW Building Consultants,inc.(CA#9813) Lyndon F.Schmidt,P.E.
4. Quality Assurance 0��p60E890�iiBpBe68�
Certificate of Participation issued by National Accreditation and Management %� gd',d ffj,1/ a�
Institute,certifying that Plastpro,Inc.Is manufacturing products within a quality `�`' f'=••'_•°•_ . oa
assurance program that complies with 1S0/1EC 17020 and Guide 53. 9 y a°� �` •'Gi$ °��
e0 �,•• C o ca
m o
No 43409 a
4 p.
v STA i t it O
n
�°�v •�l=�,',r esti';�o''o�� Lyndon F.FL PE No.Schmidt,3409
c80 -.40R,
.-.
Sheet 1 aft csoy� p � �gho�b 813 1120 1 7
} ' of DSO FLUSH DOOR
DOOR WIDTHS
2.U., 2'G"
23.75'?:. 27.7__5^ ``�'� 35.75" � �'° � � 33.75"
Y"
V
r w s r m
C, — r r r r r r r
2'0"x6'8" & 2'4"x6'8" 2'10,•X6.8,•
2'6" 2'8^
rk ' 29.75' 31.75
51.75^ I
$e.
r — r r r — — — r .e
8,01,x6,8" 2,6„x6,8„ & 2,8„x6,8„ 8,6"x6'8„
i_
'• NOTE:BY REQUEST.DOOR HEIGHT COMESINVARaNGDIMENSIONSTOAMINIMUMOF79`.EKCESSWILL8ETAKENFROMBOTTOMPAILALLOTHERDIMENSIONSWILLREMAINTHESAME.
CUTOUTS & GLASS
y;
' M rb, cvt.. 21'x65"
gSass 20 .64'
''z•:�.'jY Ya” NtOu[ 23'x6S”
glass 22'x64•
A=DISTANCE FROM TOP OF DOOR TO TOP OF CUTOUT
4t_
MATCHING SIDELITES
SLS00
Available Widths:
1.0,.
1.2.,
<a
z:.
is
X i>5
Spec Page a 173
�i
r'?
PLASTPRO"S QUALITY
. ;�• PATENTED HYDROSHIELD TmTECHNOLOGY
;z~ Our exclusive HydroShield Technology protects our
doors against moisture and humidity infiltration, by ® HyoroShield'
creating a fully composite barrier that encases and a
protects the door on all six sides. It prevents warping, technology
delamination,corrosion,rotting,and the buildup of mold
r
and mildew. Our doors with HydroShield Technology
used with our Polyfiber (PF) Door Frames create an
enhanced,impenetrable entryway.
FIBERGLASS REINFORCED DOOR SKINS
cB
' Our exclusive formula is measured precisely to
' ensure each skin is produced to the highest quality.
:= With unlimited design options, customized panel
configurations are possible.The skins require little
maintenance and will not splinter, dent, warp, rot, n'
?s or rust. They can be painted, stained, and we
provide a variety of graining options.
FULL LENGTH COMPOSITE STILES
Our full-length composite stiles protect the
door from external moisture to prevent warping
or rotting. They have twice the screw-holding '
strength of wood.
COMPOSITE TOP&BOTTOM RAILS
High strength composite to
P P and bottom rails
prevent moisture from seeping into the door and
stops the buildup of mold.
k
r EXTENDED LOCKBLOCK
Plastpro's full length LVL allows any type of lock to
be placed for increased security. ,;ry:.,`
9
POLYURETHANE FOAM CORE `
Our advanced CFC-free,high density,Polyurethane
Z foam core enhances the door's soundproofing
capabilities and provides insul tion up to six times
greater than wood doors.
BACKED BY WARRANTY
We are proud to offer one of the best warranties in the A
industry. Plastpro products are held to high standards.
z.., f
6 We stand behind our products and guarantee the best
quality to meet your performance expectations.
zu
V
.Z
W
PLASTPRO DOOR THEIR DOOU.
R
LL
f
a.
'•� T
Full length composite top and bottom.rails enhance Composite bottom rails with wood exposed on the
the durability. and performance of the door by bottom of door allowing for moisture penetration.
preventing any water penetration, which eliminates
the natural cracking found with wood.
High impact skin with beautiful old world ® Shallow embossed skin resembling steel doors,
craftsmanship will not split,dent,or rust. reducing curb appeal.
Full length composite stiles offer non-porous ® Limited length wood stiles allow moisture to enter
protection that prevents water from seeping into creating future maintenance issues.
the door, which eliminates the natural cracking that
occurs with wood.
Full length LVL block provides stronger rigidity and a Average wood lock block of 12".
range of door locks and hardware to be installed on
the door to increase security.
Polyfiber (PF) Door Frame is durable, long=lasting, Wood frame material will crack or rot over time.
and enhances the quality and performance of the
entryway when used with our door.
F"H droShielde - f '
t echnoIogy
TESTING RESULTS
:.: ASTM D1761 SCREW HOLDING CAPACITY
Z ...
`NWWDA TM-7 CYCLE SLAM TEST
NWWDA TM-8 HINGE LOAD RESISTANCE TEST
ASTM E 283 AIR INFILTRATION
' ASTM E 331 /E 547 WATER RESISTANT
ASTM E 330 UNIFORM STRUCTURAL LOAD
� ASTM E1886/E1996
IM PACT/CYCLE TEST
AAMA 1304 FORCED ENTRY RESISTANCE TEST
TAS 201 1 M PACT TEST
TAS 202 AIR/WATER/STRUCTURAL TEST
TAS 203 WIND PRESSURE CYCLE TEST
NFRC 100/200/500 ENERGY EFFICIENCY
ASTEM E90/STC/OITC SOUND TRANSMISSION
"ULC 10 C/NFPA 252/ASTM E-2074 FIRE RATED
CDPH/EHLB METHOD V1.1 2010 VOLATILE ORGANIC CHEMICAL EMISSION TEST
JIS Z 2801:2001 ANTIMICROBIAL PRODUCTS TEST
ASTM D1413-07 ANTIFUNGAL WOOD PLASTIC COMPOSITETEST
CSFM 12-7A-1 EXTERIOR WILDFIRE EXPOSURE TEST
AAMA 1702 EXTERIOR DOOR TEST FOR MANUFACTURED
HOUSING
AAMA 920 OPERATING CYCLE TEST
AAMA/WDMA/CSA 101 !I.S./A440(NAFS) NORTH AMERICA FENESTRATION TEST
The PLASTPRO DOOR met requirements for sawing, planing, routing, boring,drilling and chiseling. For
more specific results, please see our website at www.plastproinc.com or contact our Customer Service
Department at 1 800 779-0561.
WARNING:These products may include styrene,titanium dioxide and wood dust,which are known to the State of California to cause cancer.
$
u•;-. ;; For more information go to www.p65wamings.ca.gov