Loading...
HomeMy WebLinkAboutRoseman_Permit ApplicationAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 09/10/2019 Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X PERMIT TYPE:Other AQSED IMPROVEMENT LOCATION: Address: 9425 S Ocean Drive, Jensen Beach, FL 34957 ( Unit 65) Property Tax ID #: 3535-333-0001-770-0 Site Plan Name: Project Name: DETAILED DESCRIPTION OF WORK: Install RETEX-18 electric tankless water heater. CONSTRUCTION INFORMATION: Additional work to be performed under this permit —check all that apply: _Mechanical _ Gas Tank _ Gas Piping _ Shutters Electric )L Plumbing _ Sprinklers Total Sq. Ft of Construction: _ Cost of Construction: $ 250.00 Generator Sq. Ft. of First Floor: Lot No. Block No. _ Windows/Doors Roof Pitch Utilities: _ Sewer _ Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name Kaitlyn Roseman Name: Joseph Brownlow Address: 9425 S Ocean Drive Unit 65 Company: Premier Plumbing and Air City: Jensen Beach, FL State: _ Zip Code: 34957 Fax: Phone No. 772-233-8053 Address: 108 NE Dixie Hwy City: Stuart State: FL Zip Code: 34994 Fax: Phone No 772-692-2500 E-Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail preplbgac@gamil.com State or County License CFC-1427780 If value of construction is 52500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. Lf PP�EItIiE�fT�L �01, TRUCTIC�N,, EIEN LAIN INFORMATION: DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: �NotyApplicable Name: Name: Address: Address: City: State: City: State: Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: _Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure is in which conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED 0# THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LEND It OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Signature of Owner/ Lessee/Contractor as Agent for Owner Signature of Contractor/License Holder STATE OF COUNTY OF FLORIDA �I O/T FLORIDA Cl� OY )1 COUNTSTATE OF efore me The for ing instrument was acknowledgLCLeWby this Ibday of _ 20 The for ing instrum t was acknowledged efore me this day of 0 207vby S rem low Name of persoh making statement. Name of person 6aking statement. Personally Known X OR Produced Identification Personally Known _� OR Produced Identification Type of Identification Type of Identification Produced Produced i (Sign ture o"NotaryPu T�-F Commission GG 208194COmmi3Sgtl#GG2081Commission igna ure of Notary Public- St e of toMLEY APRILBRUMLEY .._' Ex 17,2022 roy e�uF�nrn�resao,�as7 mmission No. I res 17,21122 FOF ihu Troy Fain REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev. 2/7/19 00,IW7 w� the PERMIT # ISSUE DATE PLANNING & DEVELOPMENT SERVICES Building & Code Compliance Division BUILDING PERMIT SUB -CONTRACTOR AGREEMENT k0pany Name/Individual Name) �.r , (Type of Trade) For the project located at (Project Sub -contractor for I/rffilvl/ 'PI (Primary Contractor) Address or Property Tax ID #) have agreed to be NA tv) and [41r It is understood that, if there is any change of status regarding our participation with the above mentioned project, the Building and Code Regulation Division of St. Lucie County will be advised pursuant to the filing of a Change of Sub -contractor notice. CONTO CTOR SIGNATURE (Qualifier) 0 wn 6oi P INT NAME " lq�z77150 COUNTY CERTIFICATION NUMBER State of Florida, County of Jy\QY I n The foregoing instrument was signed before me this /y day of1,,� Y, 208 by3059�p h ?DyC wQ KA 1 who is personally known Y,_or has produced a as identification. p� �✓ STAMP -SignatuV of Notary Public Ayy-NO �um1.2u Print Name of Notary Public APRIL BRUMLEY gA • ; Commission # GG 208194 Expires April 17, 2022 :FOF F`°e Bonded Thru Troy Fain Insurance 8W38&7019 Revised 1 SUB-CONTRACYbR SIGNATURE (Qualifier) PRINT NAME a8780 COUNTY CERTIFICATION Aar State of Florida, County of Isar- in �k a=;7,20ff menttwas signed before me this day of by who is personally known _or has produced a t Janice M. Costanzo NOTARY PUBLIC STATE OF FLORIDA ysi 0? Comm# GG050437 N e� Expires 11/30/2020 STAMP 7 7 PERFORMANCE' The new degree of comfort:" PERFORMANCE'" tankless electric water heaters offer continuous hot water quick and on demand 4r for single point -of -use or multiple applications RETEX-04 RETEX-06 Performance Features ■ On demand, consistent and endless hot water ■ Compact and stylish with digital temperature control in increments of 1 OF ranging from 80°F to 140°F* ■ 99.8%b Energy efficient ■ Robust copper immersion heating elements with brass top increases durability and are threaded for easy replacement ■ Simple Installation ■ Digital temperature display ■ External controls to adjust temperature in increments of 1 *F* Applications ■ Whole -Home - up to 6 GPM ■ Water -Saver Shower Head - 1.5 GPM ■ Standard Shower Head - 2.0 GPM ■ Standard Hand Sink - 0.5 GPM ■ Kitchen Sink -1 to 2 GPM ■Bath Tub -z4GPM ■ Dishwasher - 1 to 2 GPM ■ Washing Machine -1 to 1.5 GPM Average Gallons Per Minute (GPM) based on 2010 Plumbing Standards Warranty ■ 5-Year heating chamber and 1-year parts limited warranty See written warranty for complete details 'RETEX-04 and RETEX-06 only show output temperature and are non -thermostatically controlled MODEL NUMBER TEMPERATURE RISE °F -- - ----- -_..---- ____ 0.5 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 GPM GPM GPM GPM GPM GPM GPM GPM GPM RETEX-04 48° - - - - RETEX-06 75° 37° - - - - - - RETEX-08 - 55° 36° 27° 22° 18° - - - RETEX-08 (derated 208V performance) 79° 40° 27° 20° - - - - - RETEX-11 - 75° 5o° 38° 30° 25° - - - RETEX-11 (derated 208V performance) - 56° 37° 28° - - - - - RETEX-13 - 89° 59° 44° 36° 30° 22° - - RETEX-13 (derated 208V performance) - 69° 46° 34° - - - - - REfEX-18 - + 820 62° 49° 41° 31° 251 - RETEX-18 (derated 208V performance) - 90° 60° 45°r 30° - - - RErEX-24 - + + 82° 55° 41° 33° 27° RETEX-24 (derated 208V performance) - + + 60° 40° 30° 24° 20° RETEX-27 - + + 92° 62° 46° 37° 311 RETEX-27 (derated 208V performance) - + + 681 45°34° 27° 23° RETEX-36 - + + + 82° 62° 49° 41° RETEX-36 (derated 208V performance) - + + 91 73° 61 ° 45° 36° 30° +Temperature electronically limited setting on adjustable thermostat on front cover RETEX-08 RETEX-11 RETEX-13 RETEX-24 RETEX-27 fn RETEX-18 RETEX-36 SoTested andcertified by the aeQualityAssociation against NSF/ANSI 372 for lead free compliance. Intertek See specifications chart on next page. 12/16 FORM NO. THD-PTE PERFORMANCET"1 tankless electric water heaters RETEX-04, RETEX-06 Unique Features: • External Digital Display - shows outlet temperature • Durable Copper Immersion single heating element, field serviceable • Simple Installation - 3 Foot electric cable included; Bottom 1/2" NPT water connections RETEX-08, RETEX-11 RETEX-13 Unique Features: • External Adjustable Digital Thermostatic Control with LED display (+/-1 degree accuracy) • Durable Copper Immersion two heating elements, field serviceable • Simple Installation - 3 Foot electric cable included; Side 1/2" compression water connections RETEX-18 Unique Features: • External Digital Thermostatic Control with LED display (+/-1 degree accuracy) • Most advanced self - modulation, adjust power to meet hot water demand • Durable Copper Immersion two heating elements, field serviceable • Simple Installation - Bottom 3/4" NPT water connections RETEX-24, RETEX-27 Unique Features: • External Digital Thermostatic Control with LED display (+/-1 degree accuracy) • Most advanced self - modulation, adjust power to meet hot water demand • Durable Copper Immersion three heating elements, field serviceable • Simple Installation - Bottom 3/4" NPT water connections PERFORMANCE' Tan kless Electric Specifications rr The new degree of comfort:" RETEX-36 Unique Features: • External Digital Thermostatic Control with LED display (+/-1 degree accuracy) • Most advanced self - modulation, adjust power to meet hot water demand • Durable Copper Immersion four heating elements, field serviceable • Simple Installation - Bottom 3/4" NPT water connections DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) MODEL NUMBER kW AMPS RECOMMENDED BREAIOA SIZE VOLTAGE RECOMMENDED WIRE SIZE (CU) MIN. FLOW (GPM) MAX. FLOW (GPM) HEIGHT WIDTH DEPTH WATER CONN. SNIP WEIGHT (LBS) 120V 1 HEATING CHAMBER RETEX-04 3.5 29A (1x30)A 120 10AWG f 0.3 74.8 5-7/8 10-7/8 1 2-3/4 1/2 NPT 4.5 240V' 1 HEATING CHAMBER RETEX-06 5.5 29A (lx30)A 220 10AWG 0.3 4.8 5-7/8 10-7/8 2-3/4 1/2 NPT 4.5 RETEX-08 8.0 33A (1x40)A 240 8AWG 0.3 4.8 12-5/8 8-1/4 3.5/8 1/2CF 7 RETEX-08 (derated 208V performance)* 5.8 28A (1x40)A 208 8AWG 0.3 4.8 12-5/8 8-1/4 3-5/8 1/2 CF 7 RETEX-11 11.0 46A (1x50)A 240 6AWG 0.3 4.8 12-5/8 8-1/4 3-5/8 1/2CF 8.5 RETEX-1I(derated 208Vperformance)` 8.2 29A (1x50)A 208 6AWG 0.3 4.8 12-5/8 8-1/4 3-5/8 1/2CF 8.5 RETEX-13 13.0 54A (1x60)A 240 6AWG 1 0.3 4.8 12.5/8 8-1/4 3-5/8 1/2CF 8.5 RETEX-13(derated 208V performance)' 10.1 49A (1x60)A 208 6AWG 0.3 4.8 12-5l8 8-1/4 3-5/8 1/2CF 8.5 240V* 2 HEATING CHAMBERS RETEX-18 18.0 75A (2x40)A 240 8AWG 1 0.3 7.0 1 18-1/4 14-1/2 3-112 314NPT 14.78 RETEX-18 (derated 208V performance)* 13.3 64A (2x40)A 208 8AWG 0.3 7,0 18-1/4 14-1/2 3-1/2 3/4 NPT 14.78 240V* 3 HEATING CHAMBERS RETEX-24 24.0 1DOA (3x40)A 240 8AWG 0.3 7.0 18-1/4 17-5/8 3-1/2 314NPT 17.8 RETEX-24 (derated 208V performance)' 17.5 84A (3x40)A 208 8 AWG 0.3 7.0 18.1/4 17-5/8 3-1/2 3/4 NPT 17.8 RETEX-27 27.0 112A (3x40)A 240 8AWG 0.3 7.0 18-1/4 17-5/8 3-1/2 3/4 NPT 17.8 RETEX-27 (derated 208V performance)' 20.0 96A (3x40)A 208 8 AWG 0.3 7.0 16-1/4 17-5/8 3-1/2 3/4 NPT 17.8 240V' 4 HEATING CHAMBERS RETEX-36 36.0 150A (4x40)A 240 8AWG 0.3 8.0 18-1/4 21-5/8 3.1/2 Y41NPT 22.7 RETEX-36 (derated 208V performance)' 26.6 127A (4X40)A 208 8AWG 0.3 8.0 1 18-1/4 21-5/8 3-1/2 314 NPT 22.7 • 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check with local officials prior to derating the electrical infrastructure. 12/16 FORM NO. THD-PTE PERFORMANCET11 tankless electric water heaters Product Specifications (all models) Rated Pressure 25 PSI min., 150 PSI max. Certifications ETL Listed to UL 499 and CSA Std. Temp. Settings 120°F (Adjustable 80°F-140°F) Temp. Accuracy +/-1 ° at steady state flow Turn -On 0.3 GPM Optional Inline Flow Regulator • Enhanced outlet temperature control • Install on the outlet side of the heater • Limit maximum volume to the specified flow rate to ensure exiting temperature is within an acceptable range • Flow Regulators for 1/2" and 3/4" plumbing connections • Flow range: 1 to 5 gallons per minute RNEEM'PART NUMBER GPM RATING OF INSERTS PROVIDED CONNECTION SIZE RTE10001A 1.0,1.5, 2.0 112" NPT RTE10001B 2.0, 3.0, 4.0, 5.0 3/4" NPT Suggested Sizing Guide COLD CLIMATE (INLET TEMP. 35-45-F) WARM CLIMATE (INLET TEMP. 50-60-F) HOT CLIMATE (INLET TEMP. 65-75-F) RETEX-04 WA N/A WA RETEX-06 WA N/A WA RETEX-08 RTE10001A RTE10001A RTE10001A RETEX-11 RTE10001A RTE10001A RTE10001A RETEX-13 RTE1G001A RTE10001A RTE10001A RETEX-18 RTE10001B RTE10001B RTE100018 RETEX-24 RTE100018 RTE10001B RTE10001B RETEX-27 RTE10001B RTE10001B RTE10001B RETEX-36 I RTE10001B RTE10001B RTE10001B Selection based on inlet temperature and an outlet temperature setting of 105°F / � /� The new degree of comfort:" Suggested Specifications Unit shall have copper clad immersion heating element(s) with brass terminations for increased durability. External temperature control and display adjustable in 1 ° increments with a range of 80°-140T Display shall be capable of displaying setpoint temperature in Celsius or Fahrenheit temperature scales. Unit shall utilize a flow meter with a 0.3 gpm activation point and manage power based on actual flow rate and inlet temperature. Values should be processed 60 times per second. Unit shall be WQA certified lead free, certified to UL499 and CSA22.2. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com 12/16 FORM NO. THD-PTE