Loading...
HomeMy WebLinkAboutProduct Approval dbpraDeprorezionntaoif d FLA ManufacturedBuildmgProgram Sl1511��55 26D1 BlairStoneRoad niamoI1 Tallahassee,Florida3239M772 Phone:85D.437.1624,Fax 050.414.8436 Halsey Beshears, Secretary Ron DeSantis, Governor August 07,2019 Alex Martens Superior Sheds,Inc. 2323 S.Volusia Ave Orange City, FL 32763 RE: Manufacturer Certification,ID MFT-113; Expiration Date: August 07, 2022 Dear Alex Martens It is my pleasure to inform you that Superior Sheds,Inc., located at 2323 S.Volusia Ave,Orange City,FL 32763, has been approved under the Manufactured Buildings Program,as provided for under Chapter 553, Part I, Florida Statutes,to manufacture Storage Sheds, Manufactured Buildings for installation in Florida. Construction or modification on a manufactured building cannot begin until the Third Party Agency has approved the plans in accordance with the current Florida Building Code. Your Third Party Agency is a contractor for the Department and has statutory authority and responsibilities that must be met to maintain approved status.You may expect and demand quality plans review and inspections. Each Code change will make your plans obsolete until they have been reviewed,approved and indicated [on the cover page of the plans]for compliance with the Code by your Third Party Agency for plans review. Please ensure that your plans are in compliance and are properly posted on our website.All site-related installation issues are subject to the local authority having jurisdiction. The Department's contractor will make unannounced monitoring visits at least once each year. You must grant complete access to your manufacturing facility and records to remain in compliance with the rules and regulations of this program. I Your certification is approved for three years from this date.You will receive a renewal notice by Email generated by the BCIS(www.floridabuilding.org)for online renewal. If you have questions you may contact Robert Lorenzo at 850-717-1835 or our FAX at 850-414-8436. Please visit our website at www.floridabuilding.org to see valuable information on the Florida Manufactured Buildings Program. A copy of this letter must accompany applications for local building permits. Sincerely, Robert Lorenzo Manufactured Buildings Program cc:Top Line Engineering, LLC I i FDOH in St. Lucie County 114 Environmental Health Site Plan Approved for Construction Supersedes All F r evious Site Plans for OSTDS # 5'0 767&Well# ' Date:_-)J2.0 • Re��evv.�r. ` J�Czj f `'le 06) 6942 l�J 3 t4 i ljr iri�� _4 j IT7aCL; I 7P I SURVEYOR'S CERTIFICATE mwim_aL -mc LEGEND � UMNTYPICAL I HEREBY CERTIFY THAT THIS SURVEY MAP IS TRUE AND -O- -80TING VAAE FENCE 4UMETER CORRECT TO THE BEST OF MY KNOWLEDGE AND BEIdEF AS — •OUSTM CNAWLNX FENCE CM _CONCRETE MMNBh SURVEYED IN THE FIELD.I FURTHER CERTIFY THAT THIS -EQ87M VMO FENCE A _RON ROD SURVEY COMPLIES WITH THE MINIMUM TECHNICAL STANDARDS CASNPWE -CENR U N FENCE aw -N L DU SET FORTH IN CHAPTER SJ-17 BY THE FLORIDA BOARD OF LAND SU . RS URSUANT_TO CHAPTER 200946 FLORIDA E� t Y �RETEt AMENi STAT D NO ABOVE GRO NO ON _09W MY 1 4RONROD OR IRON PIPE ENCR H TH SHOWN. Sr' -BtOEwALKoRWMAWAY Poo -POINT OPCOW4ENCEW_W $ r \ •jt �Y �l11 NF -WOOD FRAME OW CONCRM � -RmANeNT CwMOL POw PPC -PONT OOFF TANGENCY OURV (MI JlEAOURED DU3TANCE BEARIlq T7EDDISTANCEiBEARRVO PROFESSIONAL SURVEYOR AND MAPPER ffr REVERSE CURVATURE FLORIDA (L7 4ALCWTED DISTANCE&SFARe FL REGISTRATION 811 CH �1 CO -CHORD BEARING (D) ­DEEDEO C%TANCE a BE'QW D MARK W.TEEPE,P.S.M. 40 4ELTAANOLE PBM -PROFESSIONAL SURVEYOA AND LEGAL. DESCRIPTIONom (AS FURNISHED BY CLIENT) LOT 4, BLOCK 3,GREEN ACRES UNIT THREE,ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 16,PAGE 11 f 28,PUBLIC RECORDS OF ST.LUCIE COUNTY,FL. ADDRESS: 4994 DEANNA LANE FORT PIERCE,FL. SURVEY NOTES: ,1} f z oa 1.NOT VALID UNLESS SEALED WITH AN EMBOSSED •(! j I SURVEYOR'S SEAL. t' 2.LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR RIGHTS-OF-WAY,EASEMENTS,OR OWNERSHIP. 3.'LAND DESCRIPTION HEREON WAS PROVIDED BY THE CLIENT. p 4.'BEARINGS SHOWN HEREON ARE BASED ON THE PLAT _ �1j�Q 5,THE PURPOSE OF THIS SURVEY IS FOR USE IN yt, OBTAINING TITLE INSURANCE AND/OR FINANCING AND SHOULD NOT BE USED FOR DESIGN OR CONSTRUCTION PURPOSES UNLESS OTHERWISE STATED ON THE SURVEY. ELEVATIONS SHOWN HEREON ARE BASED UPON �D Wt'iVt� ss ! 7.DIMENSIONS PREVAIL OVER SCALE. - � 8.ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY OR yVi`� 1 PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT '�I 0 OF THE SIGNING PARTY OR PARTIES. ---— n ! 9. SURVEY NOT-COVERED BY PROFESSIONAL LIABILITY INSURANCE. jy) 10.THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT �t)I OF A COMMITMENT FOR TITLE INSURANCE. ��MI7 N 1 11.UNDERGROUND UTILITY INST"TtONS,UNDERGROUND IMPROVEMENTS,FOUNDATIONS AND/OR ANDY OTHER UNDERGROUND STRUCTURE S RE THIS SURVEY UNLESS SPECIFICALLY NOTED. TATED BY 12 UNLESS NOTED OR DEPICTED OTHERWISE,ALL PROPERTY CORNERS SHOWN WERE FOUND AND HAVE NO IDENTIFICATION OR SAID•IDENTIFICAnON WAS ILLEGABLE. M1 13.THIS SURVEY IS PREPARED FOR THE EXCLUSIVE USE AND BENEFIT OF ONLY,THE PARTIES CERTIFIED TO HEREIN,RIGHTS OR LIABILITY TO ANY THIRD PARTIES CANNOT BE TRANSFERRED OR ASSIGNED. L4 CERTIFIED TO: hFLOOD ZONE: "lC' UNMAPPED `fl 12111C0160J DATED 2/16/12 ELEV -ELEVATION •TYPrALEMATION FIELD WORK.COMPLETED: 4INgH FLOOR ELEVATION m �H'""RL` BOOK CORN TONF StiRVEYIi� ; BOUNDARY AND IWROVEMEWM SURVEY 00�I Do �BOOK OOK �- 71 ` PREPARENTHR�: Po -PAOE *OU 325 SW so H QUICK CIRCLE ! �v I fouNo ( S LE: W DRAWN BY: FILE NO.: ppVMT vm � PORT ST.LUCIE,FLORIDA 3403 ' r, PKGFILE mm TMp TYPICAL ML*�77�1�� � DAT ' 1,W •MTERMETER FS PG: PAGE: l IM PANT ' corm tofww VdyIfl$Qh01ma0.00m(EIAASL}! PKG FH _ LP jl3wPOLE UP diiRiTYpOIE OR Ut 1l9 �lNiyEY SETUP AND INSTALLATION OF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING ,3IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. . AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED 30" AUGER ANCHOR THRU THE 2"x4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL (4,900LB) 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. INSTALLED PER MANUFACTURER'S . ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO INSTRUCTIONS. EYELET AT FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. MAXIMUM OF 6" ABOVE GRADE. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. I TABLE 1 TABLE 2 TABLE 3A ANCHORING TO CONCRETE SKID RUNNER SPACING* PAD TYPES SHED WIDTH UPLIFT (PLF) ANCHOR SPACING SHED WIDTH X1 X2 X3 TYPE PAD DIMENSIONS MAX. LOAD* MATERIAL 20'-0" 400 S-6" 13'-8" 1'-104" 1'-104" 1'-104" I 2"x8"x16" 1778LBS CONCRETE BLOCK CEMENT AND SAND 280 S-6" i l'-8" 2'-8" 6'-4" — II 4"x8"x16" 3500LBS CONCRETE BLOCK CEMENT AND SAND 11'-8" 240 S-6" 10'-0" V-7" 6'-10" — III 16"x16" 3950LBS ABS PLASTIC PADS 10'—O" 200 3'-6" 8'-0" 0'-9" 6'-6" — IV 8"x8"x16" 1900LBS CONCRETE BLOCK CEMENT AND SAND 160 3'-6" 6'-0" 0'-10" 51" — * BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPIC NOTES 6'-0" 120 S-6" -VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"x4" 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE ST< SKIDS ONLY. 13'-8" WIDE SHEDS HAVE (4) SETS OF SKIDS. ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 11'-8"AND 13'—B" WIDE SHEDS ONL TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW*(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER INTERIOR SIDE RUNNER PAD TYPE PAD PAD TYPE 13'-8" SW/DW 4.15/332 0"TO 6" 6'-0" 1936LB I, II, III, OR IV 1879LB I, II, III, OR IV 11'-8" SW/DW 6.00/480 0"TO 6" 6'-0" 2558LB I, II, III, OR IV 2558LB I, II, III, OR IV '10, .0" SW/DW 5.00/400 0"TO 6" 6'-0" 2400LB I, II, III, OR IV 2400LB I, II, III, OR IV 8'-0" SW 4.00/320 0"TO 6" 6'-0" 2029LB I, II, III, OR IV 2133LB I, II, III, OR IV 6'-0" SW 3.00/240 1 0"TO 6" 6'-0" 1658LB I, II, III, OR IV 1866LB I, II, III, OR IV • LOAD WIDTH OF UPLIFT ON RUNNER NOTES 1. PAD SPACING IS END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. &USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. 2"x2" GALVANIZED WASHER 2"x2" GALVANIZED WASHER - WITH 1/2" NUT 1/2"THREADED ROD WITH 1/2" NUT OPTIONAL FOR "HIGH SET" 1/2"THREADED ROD EYES BOLTED TOGETHER WffH 1/2"x2" OPTIONAL FOR "HIGH SET" BOLT & NUT WITH (2)2"x2" GALVANIZED 1/2" COUPLER 1/2" COUPLER _ WASHERS (2.000LB SHEAR CAPACITY) 1/2"x12" FORGED EYEBOLT " < x �4" a EYES BOLTED TOGETHER WITH 1/2"x2" TYPE I, II, III, OR IV PAD WITH BOLT & NUT WRH UB SHE GALVANIZED N BLOCKING AS REQUIRED (SEE TABLE 3). 1/2"x3" (400 LB.) \-SIMPSON A-24 CONCRETE: WASHERS (2.000LB SHEAR CAPACITY) CONCRETE WEDGE ANCHOR CLIP OR EQUAL LOCAL CODE 30" EARTH AUGER ANCHOR (SEE TABLE 1 FOR SPACING) (SEE TABLE 4 FOR SPACING) SHED WITH SKID SHED WITH SKID TO PAD OR BLOCKING ANCHORED TO CONCRETE TIE-DOWN DETAILS .. .., . SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. - 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS LEVEL,.BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). �• j'I 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THEv—r FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)4"x44" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE ((. LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. CODE INFOR ATION 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). CODE VERSION FBC 2017 6th Edition,ASCE-7 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS MANUFACTURER SUPERIOR SHEDS REMOVED. BUILDING TYPE LIANUFAMURED BUILDING RESIDENTIAL LAWN STORAGE 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO CONSTRUCTION TYPE V-B FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS ALLOWABLE NUMBER OF STORIES 1 L1GE BASIC WIND SPEED V-200mph 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE EXPOSURE 0 AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE ENCLOSURE ENCLOSED HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). INTERNAL PRESSURE COEFFICIENT +/-0.18 LOCATE ANCHORS PER TABLE 4A OR 48. IMPORTANCE FACTOR 1.15 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE ROOF DEAD LOAD IOPSF (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH ROOF LNE LOAD saPSF OR 300Iba THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED JALITY PORTIONS OF SHEDS ON LEVELING BLOCKS. FLOOR DEAD LOAD BPSF i JA FLOOR LIVE LOAD STD.75PSF- 125PSF OPT. JAUTY TABLE 4A •11X 30" AUGER ANCHOR SPACING - SINGLE WIDE 1"R"RATING of WALLS, FLOOR, ROOF MODULES PER BUILDING 1 JAUTY SHED WIDTH LW* UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING*** HURRICANE PROTECTION USAGE No aJX 13'-8" 7.00 243 0'-0"TO S-0" 10,-0" HURRICANE SHELTER USAGE No SQUARE FOOTAGE LESS THAN 720 SO.Fr. 11'-8" 6.00 208 0'-0"TO 3'-0" 10'-0" ;ED REVISIONS 10'-0" 5.00 174 0'-0"TO S-T 10'-0" REV DESCRIPTON DATE BY 8'-0" 4.00 138 0'-T TO S-Or 10'-0" 1 2017 FBC 11/12/17 MM 2 GROUND ANCHOR 6"AF.G MAX.,ANCHOR EXTENSION 5/26/18 MM 6'-0" 3.00 104 0'-0"TO 3'-0" 10'-0" TABLE B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW* UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING*** Drawn By: 20'-0" 10.00 400 0'-0"TO 3'-0" 5'-0" CQ Date: MTB LOAD WIDTH OF UPLIFT ON RUNNER LLI 4/26/16 •' LOCATION FROM END WALL OF AUGER ANCHOR = Seale: ••' MAXIMUM SPACING BETWEEN ANCHORS U) N/A NOTES Model : 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. LLJ ALL 2.ALL MEASUREMENTS ARE CENTER-TO-CENTER. GENERAL NOTES 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. 1. FOUNDATION PLANS ARE NOT PART OF THIS ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-D" PLAN SET AND ARE GOVERNED BY LOCAL BETWEEN ANCHORS.. JURISDICTION. 4.ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN 2. THIS BUILDING IS EXEMPT FROM THE FBC EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE w ENERGY CONSERVATION CODE PER SECTION TO THE SIDE AS POSSIBLE. J 1015.22. M 3. REFER TO TIE-DOWN DETAILS FOR PROPER INSTALLATION REQUIREMENTS TO MEET CODE. O LJ__I -_J 0 NOTCH OR COUNTERSINK BOLT z THRU 2"x4" BOTTOM PLATE Cn 2"x4" BOTTOM PLATE NAILED I 1/2"x5" (400 LB.) CONCRETE TO 2"x6" P.T. BASE LI-I ^!. WEDGE ANCHOR INTO SLAB �4" MIN. p THRU 2"x4" P.T. BOTTOM PLATE I� — (SEE TABLE 1 FOR SPACING) Ld------- - CD _B BY OTHERS THROUGH CONCRETE SLAB BY OTHERS THROUGH _AND JURISDICTION LOCAL CODES AND JURISDICTION 0 6/1 /18 SHED WITH 'NO FLOOR' OPTION F= ANCHORED TO CONCRETE J J Matthew T. Baldwin P.E. Q Florida License #64608 w = AD-1 OF 1 r z Sheet: F- — r 1 � 1 -y End Wall Header Schedul¢180C -- 2018-12-20 TOP LINE ENGINEERING APPROVAL PLAN#SS-B-180-C Side Wall Header Schedule(180C) ! l Di Nn1tNUN Sv�SMF.V101S SCv ta'W,Oe Fnlnen vl abap S•f ad a a�r•¢I J! __ .� -¢-Ilai pn (•rA mal uaf m _ - • r ' �I - 1-faf 3-T•¢IJI'wH L 1 - I -Yf arhf nmv v -Ya¢IJ1•rab SW�Nrmv Wpl v»b,gtramecµne•¢,•„arm L,,,y��Ly�_. YawteE apart aWJcval,n,al3a•am Wla —���/�Ij���� 4 W-NmnEervllect aNEf,apAN las,rypal«a W. r�r a WWa+MeM6rafMvaopm,INa Vut Mermrellmn SaY cvnGvcb alW.uv eLov — —\ �rii I WEeWA q�em(vv ava domlrabrvclNda .� �. 49e teNvatlaYatrNmmlela/wa4le.2.Trifaf[f p.T. + m v��nmC �• COSEI lqN 1 a Tae ImJerrr De mbtlW b es lop ptle W Ovn Imr be cm,tiroa v¢ergla gWidmv nd be by matvrvn apm sltlad, cmc vu®1 W.tlsacrlm 1i a.uc me w , I � II .m•.a �m..a�w sna Y I •.24 a•rmas k'� ��. �.�r ua�"N'� .r mwac• � 111C l=^'��r°pra� YWa xs ab sm �! �� 1)TDROVENT DETAIL SIpE WALL WINDOWS EHD WALLS WINDOWS& 4'•4'W12�a4' onmx (OPDONALI l� DOOR 6'WIDE OR LE55 arN.a�>�wmmrt _ OwPaN¢nnw C.F.I. OUILLT -wL 5we oNs a-6 uc vAne. k£ P "` rww an la¢ SOURCEN O � omul v L WIRING DIAGRAM Y•emrm v a+.s npow m 6¢ar.zra-w.r ROOF FRAMING PLAN REY k YKI W. w a•. mm a Ir•w mnma M d RMSpNi n a MIE I z w z u/1x/rr �Li NA �}�irav H�iuOOwa STANDARD WALL DETAIL mm � �SKr <O a',m" " �6R an..mmr rim, exmvx s�a`nr�,amu���m NV •�roAvmm ar-a room n.0 iva Fl NATION CROSS-S CTION FNO ELEVATION _ yWj O __ _ rm anmrw x v4 r. a° mlmxlsuNsmruo zz- Ld r ~ l i�'• STATE al.m rw ( p. .rw n+.evo I i�'•• O R 10 .` I imam EVATION ENS FI,FVATIN r,m,me sv vaaa m m `� Fl OOR FRAMING PLAN k E. SSB-1 OF •w vovul q I i