HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3
t �
BCIS Home ; Log In
User Registration Hot Topics ': Submit Surcharge Stats&Facts Publications ' Contact Us ',BCIS Site Map Links Search n kii
ProductApproval
USER:Public User
db'
�
AT Product Approval Menu>Product or Application Search>Application List>Application Detail
RECEIVED
4K r r,�r4r tv •
FL# FL14911-R11
Application Type Revision SEP 13 2019
Code Version 2017
Application Status Approved
ST. Lucie County, Permitting
Comments
Archived C3
Product Manufacturer Silver Line Building Products Corp.
Address/Phone/Email One Silverline Drive
North Brunswick,NJ 08902
(732)435-1000
jonberrian@slbp.com
Authorized Signature Jon Berrian
jonberrian@slbp.com
Technical Representative Jon Berrian
Address/Phone/Email One Silverline Drive
North Brunswick,NJ 08902
(732)435-1000
jonberrian@slbp.com
n, Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
0 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Hermes F.Norero,P.E.
the Evaluation Report
Florida License PE-73778
Quality Assurance Entity Window and Door Manufacturers Association-QA
Quality Assurance Contract Expiration Date 08/03/2021
Validated By Locke Bowden P.E.
fad Validation Checklist-Hardcopy Received
Certificate of Independence FL14911 R11 COI COI Silverline SS 2017-06-14.Ddf
Referenced Standard and Year(of Standard) Standard �e Year
AAMA/W DMA/CSA/101/I.S.2/A440 1 2008
AAMA/WDMA/CSA/101/I.S.2/A440 2011
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2009
ASTM E1996 2012
ASTM E330 2002
TAS 201 1994
TAS 202 1994
TAS 203 1994
https:Hfloridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquZRj59%2fDrx2lbtd... 9/1/2019
Florida Building Code Online Page 2 of 3
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/17/2018
Date Validated 10/14/2018
Date Pending FBC Approval 10/08/2018
Date Approved 10/18/2018
Summary of Products
FL# Model,Number or Name Description
14911.1 V1 Series/50 Series(2000) Single-Hung Window
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL14911 R11 I1 SWD017 SS 2018-10-1l.Ddf
Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E. Florida P.E.73778
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5140 SS 2017-10-20.Ddf
Report for allowable design pressures,sizes,installation Created by Independent Third Party:Yes
requirements and limits of use.
14911.2 V1 Series/50 Series(2111) Single-Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL14911 R11 II SWD018 SS 2018-10-11.Ddf
Approved for use outside HVHZ:Yes Verified By: Hermes F.Norero,P.E. Florida P.E.73778
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5141 SS 2017-10-20.1)df
Report for allowable design pressures,sizes,Installation Created by Independent Third Party:Yes
requirements and limits of use.
14911.3 V1 Series/50 Series(2200/2300) Single-Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL14911 R11 II SWD019 SS 2018-10-11.0
Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E. Florida P.E.73778
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5142 SS 2017-10-20.Ddf
Report for allowable design pressures,sizes,Installation Created by Independent Third Party:Yes
requirements and limits of use.
14911.4 V1 Series/70 Series(2127) Single-Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL14911 R11 II SWD049 S5 2018-10-11.Ddf
Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E.Florida P.E.73778
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Installation Instructions and Product Evaluation FL14911 R31 AE PER5485 SS 2018-02-14.0f
Report for allowable design pressures,sizes,installation Created by Independent Third Party:Yes
requirements and limits of use.
14911.5 V3 Series/70 Series(2127) Single-Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL14911 R11 1I SWD050 SS 2018-10-11.Ddf
Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E.Florida P.E.73778
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5486 SS 2018-04-19.0f
Report for allowable design pressures,sizes,installation Created by Independent Third Party:Yes
requirements and limits of use.
14911.6 V1 Series/70 Series(2907/4907) Single-Hung Window
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL14911 R11 II SWD053 SS 2018-10-11.pdf
Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E.Florida P.E.73778
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Installation Instructions and Product Evaluation
https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgi1Z 59%2fDrx21btd... 9/1/2019
Florida Building Code Online Page 3 of 3
Report for allowable design pressures,sizes,installation I FL14911 R11 AE PERS884 SS 2018-08-17.adf
requirements and limits of use. Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Olalr Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Coovrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida taw,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
PEM W ® E M
Credit Card
Safe
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDa,uZRj 59%2fDrx2l btd... 9/1/2019
BUILDING D RO P$ 398 East Dania Beach Blvd.
Suite 338
A Perfect Solution in Every Drop! Dania Beach,FL 33004
Certificate of Authorization:29578 954.399.8478 PH
954.744.4738 FX
contact@buildingdrops.com
Product Evaluation Report
Of
Silver Line Building Products Corp.
V1 Series/70 Series Single-Hung Window(2127)
(Impact)(HVHZ)
for
Florida Product Approval
FL# FL14911
Report No. 5486
Current Florida Building Code
Method: 1—D(Engineering Evaluation)
Category: Windows
Sub—Category: Single Hung
Product: V1 Series/70 Series Single Hung Window
(2127)
Material: PVC
Product Dimensions: See Installation Instructions,SWD050
Prepared for:
Silver Line Building Products Corp.
One Silverline Dr.
North Brunswick, NJ 08902 ``��. E •, O
Prepared by: .:'L�. E,•S 'A���
Hermes F. Norero, P.E. w
N . 7 7 O
Florida Professional Engineer#73778 'O S q OF
Date:01/23/2018 % 7�
aT O
Contents:
Evaluation Report Pages 1-3 �is`S O L
Digitally signed by Hermes F.Norero,P.E. HerrnWs F1N0A6db, E.
Reason:I am approving this document Florida No.73778
Dale:2018.04.19 00:55:47-04'00'
BUILDING DROPS FL#: FL14911
A Perfect Solution in Every Drop! Date: 01/23/2018
Certificate of Authorization:29578 Report No: 5486
Manufacturer: Silver Line Building Products Corp.
Product Category: Windows
Product Sub-Category: Single Hung
Compliance Method: State Product Approval Method(1)(d)
Product Name: V1 Series/70 Series Single Hung Window(2127)
Scope: This is a Product Evaluation Report issued by Hermes F.Norero,P.E.(FL#73778)for Silver Line
Building Products Corp.based on Method id of the State of Florida Product Approval,Florida
Department of Business and Professional Regulation-Florida Building Commission.
Hermes F.Norero,P.E.does not have nor will acquire financial interest in the company .
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the Current Florida Building
Code.
See Installation Instructions SWD050,signed and sealed by Hermes F.Norero,P.E.(FL#73778)for
specific use parameters.
Limits of Use:
1. This product has been evaluated and is in compliance with the Current Florida Building Code,
including the"High Velocity Hurricane Zone"(HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Chapter 16 of the Current Florida Building Code and does not require an impact resistant
covering.
4. Site conditions that deviate from the details of drawing SWD050 require further engineering
analysis by a licensed engineer or registered architect.
5. See Installation Instructions SWD050 for size and design pressure limitations.
Hermes F.Norero,P.E.
Florida No.73778
Page 2 of 3
1(k BUILDING DROPS FLM FL14911
A Perfect Solution in Every Drop! Date: 01/23/2018
Certificate of Authorization:29578 Report No: 5486
Quality Assurance: The manufacturer has demonstrated compliance of window products in Accordance
with the Current Florida Building Code and State Rules for manufacturing under a
quality assurance program audited by an approved quality assurance entity through
Window and Door Manufacturers Association(FBC Organization#:QUA2515).
Performance Standards: The product described herein has been tested per:
• TAS 201-94
• TAS 202-94
• TAS 203-94
• ASTM E330-02
• ASTM E1886-05
• ASTM E1996-06/09/12
• AAMA/WDMA/CSA 101/I.S.2/A440-08
Referenced Data:
1. Product Testing performed by National Certified Testing Laboratories,Inc.
(FBC Organization#TST1589)
Report: Dated:
NCTL 110-16327-1 08/13/2013
Signed and Sealed by:Harold E.Rupp,FL PE No 15935,Sealed Date 02/06/18
NCTL 110-16327-2 11/05/2013
NCTL 110-16327-3 08/13/2013
2. Quality Assurance
Window and Door Manufacturers Association
(FBC Organization#:QUA2515)
3. Material Certification
Miami-Dade County Notice of Acceptance
Eastman Chemical Company(Previously Solutia)
Saflex(Vanceva Composites)PVB Interlayer
4. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance
with AAMA 303
Installation:
Refer to Installation Instructions(SWD050)for anchor spacing and more details of the installation
requirements.
Design Pressure:
Refer to Installation Instructions(SWD050)for anchor spacing and more details of the installation
requirements.
Hermes F.Norero,P.E.
Florida No.73778
Page 3 of 3
Silver Line
SILVER LINE BUILDING PRODUCTS CORP. ��' '
V1 SERIES170 SERIES SINGLE HUNG WINDOW (2127) NORTH BRUNSWICK,NJ 2
(I MPA C T RA TED)(H VHZ) PN.1100 2xm�9
J'
Z ry N
am �
o2,i"
CI
C3 tnZ pig' m
GENERAL NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MAX OVERALL SIZE MISSILE TABLE OF CONTENTS
MANUFACTURED TO COMPLY WITH THE CURRENT EDITION CONFIG. DESIGN
WIDTH HEIGHT PRESSURE IMPACT RATING SHEET REVISION SHEET DESCRIPTION >
FLORIDA BUILDING CODE(FBC),INCLUDING HVHZAND HAS z
BEEN EVALUATED ACCORDING TO THE FOLLOWING: w w
•
TAS 201-94 52" 73" O/X +55/-60 PSF UMI/SMI 1 - GENERAL NOTES&GLAZING DETAIL a
• TAS 202-94
TAS 203-94 2 - ELEVATION&ANCHOR LAYOUTS
•
� • ASTM E330-02 3 - VERTICAL SECTIONS REMARKS BY DATE
• ASTM E1886-05
• ASTM E1996-06/09/12 4 - HORIZONTAL SECTIONS
• AAMA/WDMA/CSA 101/IS.2/A44D-085 HORIZONTAL&VERTICAL SECTIONS,INSTALLATION NOES&
2. ADEQUACY OF THE EXISTING STRUCTURAL REINFORCEMENT DETAILS
CONCRETE/MASONRY,2X FRAMING,AND METAL FRAMING rxFwsrn ONOFruuoFsau
t AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF vFiiMviFmiicmaxs wseixsiuunoxio oivui
7 WITHSTANDING AND TRANSFERRING APPLIED PRODUCT mornlNEN RMEMDM=HFRnx,•u N9D
FNGINFFA eRARCx9FCf R4FLLPREPARESIFESREO9C
LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE
ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF Digitally si4" bNorero.P.E
INSTALLATION. hhtt
43/64"O.A.I.G.LAMINATED GLASS Reason:✓,9 s GlyTent
Date: 8 .38. lY/�
3. 1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND CONSISTING OF:
ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE 1/8"ANNEALED GLASS �� E• ��
_ STRUCTURE.BUCK DESIGN AND INSTALLATION IS THE 7/32"STEEL SPACER V� `S•• �� ��
RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF 3/32"ANNEALEDGLASS o N ] ]
RECORD FOR THE PROJECT OF INSTALLATION. 0.090"SAFLEX PVB INTERLAYER BY •1 7k
EASTMAN CHEMICAL COMPANY -0 5 A OF I);
4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE 3/32"ANNEALED GLASS () P•,. [!/
GENERIC AND MAY NOT REFLECTACTUAL CONDITIONS FOR
A SPECIFIC SITE.IF SITE CONDITIONS CAUSE INSTALLATION �i T
t OLICEN DEVIATE FROM EDETAILED REQUIREMENTS
ENGIN EROR ARCHI ECT SHALL P
AEPREPARE SITE EXTERIOR /// \\ INTERIOR L��G�````
SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN \ to
NON-HVHZ AREAS.IN HVHZ AREAS,ONE TIME PRODUCT I FLMDANPZ N.7=
APPROVALTO BE OBTAINED FROM MIAMI-DADE RER OR I we[oiwA euw,TO Je11
}i AHJ.
oua� ON n swot
FBPE CERT.OF AUTHORIMTION Na 295711
\
-
S. APPROVED IMPAR STEELSPACER PROTECTIVE SYSTEM ISNOT REQUIRED FL fi:
ON THIS PRODUCT IN AREAS REQUIRING IMPACTMIN.GLASS F L 14911
RESISTANCE. 1/8"OR 3/32" a BITE 7/16"
SETTING BLOCK
6. WINDOW FRAME MATERIAL:PVC DOW 995 SEALANT DATE: 01.23.18
DWG.BY: CHK.BY:
t 7
COMPONENTS CSHALL HAVE BEEN PRESEERVATIVETREATED GLAZING DETAIL 1 HR HFN
=? OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN SCALE: NTS
CHAPTER 23. NOTE:
ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH DWG•#: SWD050
` S. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 SAFETY GLAZING REQUIREMENTS OUTLINED IN
GLASS CHARTS.SEE SHEET 1 FOR GLAZING DETAILS. CURRENT FBC AND ASTM E 1300 GLASS LOAD SHEET:
n RESISTANCE.
OF 5
Silver Line
bTAncWrWH
1Br
ONE SI WERUNE ORM
NORTH BRNNSWIM NJ 08902
PH:800 2304228
0 z
MAX.O.A FRAME tD FZ p
WIDTH 52" Z 5 vi g g -11
MAX.D.L.O. CL 0
WIDTH 47.69" z 3 s cr 4
3"MAX. 6"MAX. 6.25"MAX. 4 o z C7 m
A B FROM O.C. FROM fes-- I \ < 0 0 o d
3 3 CORNERS r CORNERSW L9
W Z O 7 a
1 v7:3 ¢ >co
NOTE: _ W
ALL FASTENERSAILIN a
THE MEETING RAIL IN
THE INTERIOR IAMB v.
w
6"MAX. ^p^ TRACK MUST BE FLAT HEAD
MAX.D.L.O.
HEIGHT 33.50" O.C. REMARKS BY DATE
C
4
12.50"MAX.
MAX.O.A FRAME O.C.
HEIGHT 73"
T- THEINnA 0NDETNLl DESWBFDHMNMGFNENC
p D IAATXOTREHECFACNALmxpGI0N0NTD PEDnC:
4 11R.IG SRTmNDG1ONSG16EDi1TAWn0HAUOD
FROM TXE uDuuuEAExrs DFunm xEaEDL A ummD
MAX.D.LO. "X^ ^X" FNGIXFD...ODENRfoau Ewim�DDa rD"�
HEIGHT 33.50" "XD 6.25"MAX.
s 3"MAX.
;, FROM FROM
c CORNERS CORNERS
s of
ELEVATION ANCHOR LAYOUT ANCHOR LAYOUT A
SINGLE HUNG WINDOW NAIL FIN-SINGLE HUNG WINDOW THROUGH FRAME-SINGLE HUNG WINDOW
O
i�� \\
"ft Y7FFld.Lai
FLONDA PZ Na]J1)G
BUHOING PROPS IND
ODB E DANA BEACN BUA/1TB
DANA BEAM FL 11004
FHP[CERT.OF ANHORQATION"2957E
FL#:
FL14911
DATE: 01.23.18
DWG.BY: CHK.BY:
f HR HFN
SCALE: NTS
s DWG.#: SWD050
SHEET:
a 2
OF 5
S7SILVERUNEDRNE
5
O
C=C�O[� 0000 NORTH BRUNSWICK,W 08902
PH:IBM)2344228
Z
1 1 E
❑ 0� m
w0 G
SEE GLAZING SEE GLAZING '^❑ m< =
�
oz zg
DETAIL,SHEET 1 DETAIL,SHEET 1 N 3 $ p�_6
O O Wcc=> Y m n
� O j ❑
w
m a
r a
REMARKS BY DATE
o
EXTERIOR INTERIOR EXTERIOR INTERIOR
T.ANDI AL
M IR.—ASRE ACI
siiNWR—A—nn
I If
conomoxswEixuunoxrooLvwic
a fROM MEREWIREMFNIS DANIIDXFAEIN,ADCENSED
FNGINFFAORAR[XDECf SXALLRNF➢ARE SRESREDxC
iDR USE WRN
c �* N .77
SEE GLAZING SEE GLAZING $ A OF !Y
DETAIL,SHEET I DETAIL,SHEET I ��OT • O 0'•.•'•lt��
O
I I .u+d0.`de
/ I / RABDA P.E.Na 73M
eUKUm mops INC
JB!E
DAM
BEACH"' /]]B
t� DAMA BEACH,FL].iWi
FBPE m77.OF AUTHORD'A710N A.2p57E
FL#:
FL14911
DATE: 01.23.18
s DWG.BY: CHK.BY:
HR HFN
A VERTICAL SECTION g VERTICAL SECTION
SCALE: NTS DWG.#: SWD050
Y
3 NAIL FIN 3 THRU FRAME SHEET:
z 3 n`[I/<I
20 FL 5
p Silver Line
MAndeiseri
ONE SILVERLINE DRM
NORTH BRUNSW M NI D9902
PH:800 23"2M
SECTION FOR INTERIOR SECTION FOR 0 n Z E
BLOCK&TACKLE SEE GLAZING SEE GLAZING CONSTANT FORCE z a m R
BALANCERS \ DETAIL SHEET 1 DETAIL SHEET 1 /o` BALANCERS G
_ 0 3 t3
� WO ug ug�Mx�
�3 0 moo'
W( N J 3
=m
JII Wj 0 Ym
� EXTERIOR W a
s
a
1 D.L.O. F a
REMARKS BY DATE
MAX.FRAME WIDTH
5
HORIZONTAL SECTION
4 UPPER SASH
noETUL5oF5O118
,t 2musurnainw2a�nuumxomanswa�svEn�rc
RIE I°SIfE m1101110M UJEE VdTYlAl1ON ro DEV I1h
fR0M i11E11EDUWEA1ENi5 DETRBED HFAEDI.�DCFMED
SEE GLAZING SEE GLAZING °N�"m�"a�N°AE owmn°TMRE°a M
DETAIL SHEET 1 INTERIOR DETAIL SHEET 1
N .7 7
S A OF '
IOP•'•�jjj�
EXTERIOR
r D.L.O. NDN sIl ROREfA)a c
RGRM PX-No 73M
OULMC OROF$Bio
395 E OANIA BEA01 BiVD./330
MAX.FRAME WIDTH EzsPE Dw°r�OF�w OR 1T N.29M
e FL N:
HORIZONTAL SECTION FL14911
c 4 LOWER SASH DATE: 01.23.18
DWG.BY: CHK.BY:
t HR HFN
SCALE: NTS
DWG.#: SWD050
3
SHEET:
OF 5
4
1/4"MAX.
MIN. SUBSTRATE MIN.EMBEDMENT
SHIM SPACE SUBSTRATE SUBSTRATE Silver Line
EDGE DISTANCE BY OTHERS 3 BY OTHERS BYOTHERS MAndaFii
INTERIOR
SCREW IN THE INTERIOR
CHANNEL
MIN. ON,
MIN. EDGE DISTANCE Ld
EMBEDMENT ONE SILVERUNE DRIVE
SCREW IN THE EXTERIOR ,�„z NORTHBRUNSWIMM09902
CHANNELQ PH:(8001 2364728
zy~
PERIMETERS -� 1/4"MAX o
BY OTHERS SHIM SPACE PERIMETER SEALANT Q u
BY OTHERS 1/4"MAX• 1z'N DS Z g
EXTERIOR SHIM SPACE
MIN. O X
EXTERIOR INTERIOR EXTERIOR INTERIOR
EMBEDMENT o o Of
A VERTICAL SECTION oz >? Z'mm1a1
6 � HORIZONTAL SECTION C HORIZONTAL SECTION
N3 aIs oaoE
THROUGH FRAME(HEAD) 6 THROUGH FRAME(JAMB) 6 NAIL FIN(HEAD) LO a a o
DO
oz- i
ei= N—C m
SUBSTRAT 1MSPACE REINFORCEMENT DETAILS W Q /a
BY OTHERS 10.34" n \
INTERIOR 0.63' 0.87" ~
2 L� 0.13" REMARKS BY DATE
z _ r"J -t
w 0.77" , 0."' �
_st I 0.46"
W EXTERIOR INTERIOR T 0.06" 0.87"
m 1
0.45"
Em T- EXTERIOR 1 O LOCK RAILLOCK ALUMINUM ALUMINUM
BOTTOM RAIL&SASH NomMREF
BEDHEREINAREGEMERIC TOOE O E
sROUME CDHIPMEATEDSE LEDHEE NTDDEYEO
FROM 1HF REQUIREMFNR DETMU]IXEREN,AUCENSED
MIN.EDGE FxraxunaxARanEcrswuPREVAREvsEsxarx
DISTANCE `````iiiliill!/J���''
HORIZONTAL SECTION E VERTICAL SECTION
o E o �.
6 NAIL FIN(JAMB) 6 MEETING STILE _��`, SPO
INSTALLATION NOTES: ANCHOR SCHEDULE * N T
• 1. ONE(1)INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. MIN.EDGE
METHOD SUBSTRATE ANCHOR SCHEDULE MIN EMBEDMENT DISTANCE "O
2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION OFTHE 08 WOOD SCREW S A OF
MAXIMUM SIZE LISTED. WOOD:MIN.SO=0.65 per,,HEAD1.s o.75• � 0 )uP (V ;
NAILING FIN 3 THREADS MIN
3. INSTALL INDIVIDUAL IITHOUTCONSSI ERATIONHOFTSOLERANCES).TOWITHIN A LERANCESARENOTCUMULATVEFFROMONEINSTALLATIONANCHORTOTH NEXT. M�NCE OF:1:1/2 INCH THE DEPICTED LOCATION&SPACING IN THE ANCHOR LAYOUT M'Fy�33K5UGE 5�1 08TEKSCREW pENErRMEDN�BEroND a.so• ii�''I p
NDI OI 0ORds.a E
010 PAN HEAD INRDRIOA P.E.NO 73718
4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S).MAXIMUM ALLOWABLE SHIM STACK TO BE 3/8 INCH.SHIM EXTERIOR CHANNEL 1•S 0.75• BUY➢No MOM,PIC
368 F DAMA BEAW BLVD./338
WHERE SPACE OF 1/16 INCH OR GREATER OCCURS.SHIM(S)SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. DAM1 BEACN,n L3
WOOD:MIN.SO=0.55 FBPE QAT.OF N1TNOf02ATION N.29318
010 FLAT HEAD IN THE
S. FOR MASONRY OR CONCRETE OPENINGS,IX WOOD BUCK MAY BE USED(OPTIONAL AS LONG AS THE MINIMUM EMBEDMENT AND EDGE INTERIORCHANNEL 1.5• 0.75• FL#:
DISTANCE REQUIREMENTS ARE STILL MET WITHIN THE CORRESPONDING HOST SUBSTRATE.SEE GENERAL NOTE#3 ON SHEET 1 FOR MORE F L 14911
INFORMATION. 3 THREADS MIN
T 010 PAN MEAD INEL PENETRATION ALDATE:BEYOND OSO'
K 6. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES,INCLUDING BUT NOT LIMITED TO STUCCO,FOAM,BRICK VENEER,AND THROUGH FRAME METAL:18 GAUGE Stool, EJ(TERIORCHANN01.23.18
SIDING. MIN.Fy-33KSI
010 FLAT MEAD IN THE 3 THREADS MIN DWG. R cHKI-I F N
.'`
INTERIOR CHANNEL PENETRATION BEYOND 0.50'
j 7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT METAL
COATING.
CONCRETE:fc=3000PSI 3/16•IAT HEAD ON 125- ,.75. SCALE: NTS
FLATHEAD SW D050
e B. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK,DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS.EDGE DISTANCE IS MEASURED DWG.#:
FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK.
MASONRY:CMU perASTM 3116'rTWTAPOON 125- 1.75• SHEET:
9. INSTALLATION ANCHORS SHALL BE INSTALLED I N ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS C90 MIN.20DO PSI FLATHEAD
SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER.
10. FOR INSTALLATION ANCHORS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK,USE FLAT HEAD ANCHORS. OF 5
a