Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
r 8/26/2019 Florida Building Code Online BCIS Home I Login I User Regi tion I of To 7_- Su lnit Surde I IStats �acts I Publications I Contact Us^I BCIS Site Map, I ^Links I 'Search •I Florida � €� t Product Approval r USER:Public User FRECEIV—EDProduct Aoyroval Menu>Product or Application Search>Agplication List>Appllcati tail FL# FL15213-R3.,a ,Application Type ReVislon 7Code Version 2017 nt Application Status Approved y, Permitting Comments Archived L1 Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 (440)969-9773 Ext 16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 16 ronoconnell@21astpro.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a.Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F.Schmidt,P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan J. King, P.E. ri Validation Checklist-Hardcopy Received Certificate of Independence FL15213 R3 COI (b)Certificate of Independence.pdf Referenced Standard and Year(of Standard) Standard Year 101/I.S.2 1997 101/I.S.2/NAFS 2002 AAMA/WDMA/CSA101/I.S.2/A440 2005 ASTM E1886 2002 ASTM E1996 2002 ASTM E330 2002 TAS 201,202,203 1994 httpsJ/floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgv3yVVKJZlQRC3FgPGdg9z[GQYTOxnLFWhLKenbGmCoA%3d%3d 1/5 8/26/2019 Florida Building Code Online .� iT (lE BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge I Stats&Facts I Publications I Contact Us I BCIS Site Map I Links I Search bFlorida i :j Product Approval USER:Public User u� C4 rsrr 8`11 1 F:^�i�;u� Product Approval Menu>Product or Application Search>Application List Search Criteria Refine Search Code Version 2017 FL#' 15213.1 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL. Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search• esults-Applications Manufacturer Validated By Status d_R3 L15213- )viion Plastpro Inc./Nanya Plastics Corp. Ryan 1. King, Approved FL#: FL15213.1 P.E. istory Model:a.Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series (813)767- Fiberglass Door 6555 Description:6'8"Impact"Opaque Fiberglass Single Door-Inswing/Outswing (X-Configuration) Category: Exterior Doors Subcategory:Swinging Exterior Door Assemblies 'Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,.effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: LFONN eCkci. -ale Credit Card Safe https://fioridabuilding.org/pr/pr app_Ist.aspx 1/1 8/26/2619 Florida Building Code Online Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15213 R3 Equiv (a)Equivalency of Standards.pd Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/20/2017 Date Validated 10/20/2017 Date Pending FBC Approval 10/24/2017 Date Approved 12/12/2017 Summary of Products Go to Page Page 1/2 Model,Number or Name Description 15213.1 a.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door- �J Grain/Rustic/Mahogany Series Inswing/O2j2Z g-(X_-Qq figuratiori) Fiberglass Door Limits of Use nstallation Instructions Approved for use in HVHZ:No (Evaluation L15213 R3 II (a)Inst 15213.1.pdf Approved for use outside HVHZ:Yes erified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A ReportsOther:See INST 15213.1 for Design Pressure Ratings,anyL15213 R3 AE (a)Eval 15213.1.pdfadditional use limitations,installation instructions and produCreated by Independent Third Party:Yes particulars. 15213.2 b. Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing"Snap Frame"Glazing-Inswing/Outswing(OX or XO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.2 for Design Pressure Ratings,any FL15213 R3 AE (a)Eval 15213.2.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.3 c.Smooth Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing"Snap Frame"Glazing-Inswing/Outswing(OXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II fa)Inst 15213.3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.3 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.3.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.4 d.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing"Lip Lite"Glazing-Inswing/Outswing (OX or XO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.4.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.4 for Design Pressure Ratings,any FLIS213 R3 AE (a)Eval 15213.4.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.5 e.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing"Lip Lite"Glazing-Inswing/Outswing (OXO- Fiberglass Door Configuration) Limits of Use Installation Instructions https://floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yWKJZIQRC3FgPGdg9zlGQiYTOxnLFWhLKenbGmCoA%3d%3d 2/5 8/26/2019 Florida Building Code Online Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.S.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.5 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.5.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.6 f.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Double Door- Grain/Rustic/Mahogany Series Inswing/Outswing (XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS213 R3 II (a)Inst 15213.6.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.6 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.6.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.7 g.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Double Door with Sidelites Grain/Rustic/Mahogany Series utilizing"Snap Frame"Glazing-Inswing/Outswing(OXXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FLIS213 R3 II (a)Inst 15213.7.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.7 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.7.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.8 h. Smoot Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Double Door with Sidelites Grain/Rustic/Mahogany Series utilizing"Lip Lite"Glazing-Inswing/Outswing (OXXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.8.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.8 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.8.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.9 is Smooth/Wood Grain/White Wood 68"Non-Impact"Glazed Fiberglass Single Door utilizing"Snap Grain/Rustic/Mahogany Series Frame"Glazing-Inswing/Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.9.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.9 for Design Pressure Ratings,any FL1S213 R3 AE (a) Eval 15213.9.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.10 j.Smooth/Wood Grain/White Wood 68"Non-Impact"Glazed Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing"Snap Frame"Glazing-Inswing/Outswing (OX or XO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.10.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.10 for Design Pressure Ratings,any FL15213 R3 AE (a)Eval 15213.10.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.11 k.Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing"Snap Frame"Glazing-Inswing/Outswing(OXO- Fiberglass Door` Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.11.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A. Evaluation Reports Other:See INST 15213.11 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.11.pdf Created by Independent Third Party:Yes https://floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yWKJZIQRC3FgPGdg9z[GQiYTOxnLFWhLKenbGmCoA%3d%3d 3/5 8/26/2019 Flodda.Building Code Online additional use limitations,installation instructions and product particulars. 15213.12 I.Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Double Door utilizing"Snap Grain/Rustic/Mahogany Series N Frame"Glazing-Inswing/Outswing(XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.12.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.12 for Design Pressure Ratings,any FL15213 R3 AE (a)Eval 15213.12.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.13 m.Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Double Door with Sidelites Grain/Rustic/Mahogany Series N utilizing"Snap Frame"Glazing-Inswing/Outswing (OXXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.13.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.13 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.13.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.14 n.Smooth/Wood Grain/White Wood 68"Non-Impact"Glazed Fiberglass Single Door utilizing"Lip Grain/Rustic/Mahogany Series N Lite"Glazing-Inswing%Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.14.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.14 for Design Pressure Ratings,any FL15213 R3 AE (a)Eval 15213.14.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.15 o.Smooth/Wood Grain/White Wood 68"Non-Impact"Glazed Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series N utilizing"Lip Lite"Glazing-Inswing/Outswing(OX or XO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.15.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.15 for Design Pressure Ratings,any FL15213 R3 AE (a)Eval 15213.15.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.16 p.Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series N utilizing"Lip Ute"Glazing-Inswing/Outswing (OXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.16.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.16 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.16.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.17 q.Smooth Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Double Door utilizing"Lip Grain/Rustic/Mahogany Series N Lite"Glazing-Inswing/Outswing(XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.17.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:,No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15213.17 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.17.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.18 r. Smooth/Wood Grain/White Wood 68"Non-Impact"Glazed Fiberglass Double Door with Sidelites Grain/Rustic/Mahogany Series N utilizing"Lip Lite"Glazing-Inswing/Outswing(OXXO- Fiberglass Door Configuration) https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yWKJZ1QRC3FgPGdg9zlGQiYTOxnLFWhLKenbGmCoA%3d%3d 4/5 8/26/2019 Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.18.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created.by Independent Third Party:Yes Design Pressure: N/A Evaluation lieports Other:INST 15213.18 for Design Pressure Ratings,any FL15213 R3 AE (a)Eval 15213 18.pfff additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.19 s.Smooth/Wood Grein/White Wood 8'0"Impact"Opaque Fiberglass Single Door- Grein/Rustic/Mahogany Series N Inswing/Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R3 II (a)Inst 15213.19. df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:INST 15213.19 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.19.pdf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 15213.20 t.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series N utilizing"Snap Frame"Glazing-Inswing/Outswing (OX or XO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R3 II (a)Inst 15213.20.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:INST 15213.20 for Design Pressure Ratings,any FL15213 R3 AE (a)Eval 15213.20.Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. Go to Page Page 1/2 Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Cop i ht 2007-2013 state of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: M& 19R 99M - Credit Card Safe https://fioridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQRC3FgPGdg9zlGQiYTOxnLFWhLKenbGmCoA%3d%3d 5/5 RW R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 / / � '/ / R'II I i / 1 Octoher1 Product Category Sub Category Manufacturer Product Name Plastpro Inc. Smooth I Wood Grain I White Wood Grain Exterior Swinging Exterior Door 5200 W. Century Blvd. Rustic/Mahogany Doors Assemblies Los Angeles,CA Series Fiberglass Door Phone 440.969.9773 Inswing/Outswing-"Impact" Scope: Product.Evaluation report issued by R W Building Consultants, Inc.&'Lyndon F.Schmidt, P.E.(System ID#1998)for Plastpro Inc.,based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F,,Schmidt, P.E.do not have not will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. ' Limitations: 1. This product has been evaluated and is.in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3.-When used in areas requiring wind bome debris protection this product complies with FBC Sections 1609.1.2&R3012.1.2 and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.2.2&R301.2.1.2.1. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering•analysis by a licensed engineer or registered architect. 6. See drawing FL-15213.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 2005-02-21-001 ASTM E330-02 and ASTM El886/E1996-02 Testing Evaluation Lab.,lnc. Wendell W.Haney, P.E. 2. Drawing No. Prepared bV Signed&Sealed bV No. FL-15213.1 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt, P.E. 3. Calculations Prepared by Signed&Sealed bV Anchoring RW Building Consultants, Inc,.(CA#9813) Lyndon F.Schmidt, P.E. 4. Quality Assurance 00000aeauooQ�D000 Certificate of Participation issued by National Accreditation and °o©o�•SQCHA#/,s�Ro�oo Management Institute,certifying that Plastpro Inc.is manufacturing 0°° �,•°° Gf� products within a quality assurance program that complies with o� o°�,� ISO/IEC 17020 and Guide 53. o PIo 43409 °o p : ° STATIE O 4 ®via ° °o OR,° /ON P�%- 0o LyndonFL PE Notl43409 Ga&dueon'n 10/19/2017 Sheet 1 of 1• L RECEIVED plastpro' ..o�:. UO ;T. Lugie County, Permitting M 5200 W. CENTURY BLVD. z LOS�6VC�-r.ELES CC004 y� 37.50"MAX.O.A. ���� � >>° m FRAME WIDTH C4 U N U m Smooth / Wood Grain / White Wood Grain ^ ' 9 x W o C E m ?m° m� Rustic /Mahogany a N m a a 3 .0 LL D Series Fiberglass Door o o 3'Ld a:INSWING/OUTSWING ,IMPACT, z z N Z 0 p Wp J CO o GENERAL NOTES 110CL GO 5w N Jw 1. This product has been evaluated and is in compliance with the 6th Edition o d ^ o a N (2017)Florida Building Cade(FBC)structural requirements excluding the"High 0 a q Velocity Hurricane Zone"(HVHZ). a a 2. Product anchors shall be as listed and spaced as shown on details.Anchor m 'm embedment to base material shall be beyond wall dressing or stucco. Ul v ILI 0! 3. When used in areas requiring wind bome debris protection this product n a complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an o s LL impact resistant covering.This product meets missile level"D"and includes Wind y y z Zone 4 as defined In ASTM E1996 and FBC Sections 1609.1.2.2&R301.2.1.2.1. W 4. For 2x stud framing construction,anchoring of these units shall be the same a " that shown for 2x buck masonry construction. a FILr 5. Site conditions that deviate from the details of this drawing require further >> i engineering analysis by a licensed engineer or registered architect. m w a TABLE OF CONTENTS o SHEEr# DESCRIPTION w^z r°c Z OVERdLI DESIGN PRESS(1RE(PSF)s, v 1 Typical elevation,design pressures,&general notes DATE:02/16/12 z 2 Door panel details SWING FRAMEr scaE: N.T.S. 3 Horizontal cross sections DIMENSION POSfr1VE NEGATIVE;: owc.BY: JK m 4 Vertical cross sections ' g 5 Buck and frame anchoring-2X buck masonry construction INSWING 37.50"x 82.00" +65.0 -70.0 3 6 From anchoring-1 X buck masonry construction oanwiHc Ho.: OLITSWING 37.50"x 80.37" +65.0 -65.0 FL-15213.1 7 Bill of materials&components ro V - SHEEr 1 OF 7 z n, R\t7ients\Plastpm,Inc PERMANENT\A-Florida Product Approvals\FL-15213 Fiberglass Door-Inswing-Outswing\C-Dmwings\FL15213(2017)\FL-152131-Adwg,21 79.25°MAX.DOOR PAN[3 HBGHf N-+ N A a O = . BOO -- - N 6o v X N N ? = A A 4 1 .O N J UffM-T 0 c;5 'D n A n Q 120 F� nm m 0 a m N a z o � N 3 O O a .o I m m2 92 oIn m A fa° 3 w s T 1.5T 1.59' - N A N N m A O 0 O H n n cotto. T � e \{{111111/1, N0.43409 October 19,201 i D PRODUCT: Document,Prepared ey. Lyndon F. Sehmldt ��j�••'. �11�' IPLASTPRO INC. N D Z\ FIBERGLASS DOOR P.E No. 43409 ;owilL N\\ o N ti 2 1-071-971-7 UPDATE TO 6TH E0. (2017 FBC LFS PART OR ASSEMBLY: �/� BUILDING CONSULTANTS. INC: 04/22/15 UPDATE 1t,5TH ED. (20)4 FBC JK d 1� P.O. Box 230, VDlrico, FL 33595 I� N NO DATE BY DOOR PANEL DETAILS Phone No.: 613.659.9197 REVISIONS FSPE C.A. No. 9813 0 207'2 R.W.BUILDING CDNEIII-W6 IND. MOlients\Plasip%Inc PERMANENT\A-Florida Product Approvals\FL-15213 Fiberglass Door-lnswing-Outswing\C-Drawings\FL 15213(2017)\FL-152131-Rclwg,3.1 so A Z o W N 0�0 w 0 � •l oG) 3A m no n O• ® �H:_ N `zU ate. O d. Z 61.1 C W W W N N Z O O pp M m ;o 22 A 5-,y r A 0 C ® C W 0 N A O O Z H M 0 ww wN 117777 d 22 Z A W M m 22 M A A r w ER CA �zy 4 oOS �>c 0=0 I vm O v m � A W Co y rn W N n A SCHA`�pinmlrr� ' f " '' N0.43409 October 19,2017 o n $ 'PRODUCT- DooumaMa Praparod By:1� PI IW N i< N FIBERGLASS I OR E.d on No F43409 Schmidt ��jO��. o U1 " y 2 10 19 17 UPDATE TO 6TH ED. (2017) FBC LFS PART OR ASSEMBLY: r!L BUILDING CONSULTANTS,INC. in 1 04122,115 UPDATE TO 5TH ED. (2014) FBC JN HORIZONTAL CROSS SECTIONS �1V P•o. Box 230, Valrlco, FL 33595 N NO DATE BY Phone No.: 813.059.9197 REVISIONS FBPE CA No. 9813 02012 R .BUILDING ODN.IILTA INC. IINGientsVPlastpro.Inc PERMANENT\A-Florida Product ApprovaMFL-15213 Fiberglass Do"-Inswing-Outswing\C-Drawings\FL 15213(2017)\FL-152131-Adwg.41 .. m m O A W rr A W O A 22 O 0m 00m n•` v n ° a :3 n rc Q no NARK O O o. Z O � A Cie .. a .a O.1S' C SINK (TYP.) 1- 4"MIN. EM .(IYP.) en V a 7)1 am C a �^ 2 N m x Q0 >. ton b =i C;a9.. 0 0 2 y o A O. I 2 Z O � co A 1-114-MI EMB.(TYP.J p%\vo11ll I itIf, No.43409 fiber i9,20_17 PRODUCT: Documents •.,.. �9►;. :�``� o PLASTPRO INC. F Ed No.F434091dt Ln o' Z FIBERGLASS DOOR /� 2 70 19/17 UPDATE 1D 6TH ED. (2017) FBCALFSPART'OR ASSEldBLY: K7),,BUILDINGCONSULTANTS, INC. 1 422 15 UPDATE TO STH ED. 2014) F13C VERTICAL CROSS SECTIONS el liUl/ P•OBox 230, Valrlco, FL 33595 NO DATE YYY Phone No.: 813.659.9197 REVISIONS I FBPE C.A. No. 9813 776-7 2 R.W.BUILDING 6CNBULTANTO INC. 0Zd) _ yt m ul 7&JAMB Z -Z" 9 m cW P ^� 2X s e m d a LL BUCK �T°, E c z m 6 O a: [� _TYP.HEAD a v' 2X JAMBS 8 z BU FRAME ' 6a zo Di • ZD cr) O'n •• W� o OPS NRY WG NRY MASONRY '�'W `o V OPENING U am 2 ^1' u - ^p ^O U �o UU a >> � cam a a yw C -f' �f+• ��m N N N y Z ry BUCKANCHORING HINGEJAMB FRA ANCHORING STRI JAMB E,E C Maso 2X buck constructionEll CONCRETE ANCHOR NOTES: 1. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. o a 2 Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to a a d maintain the min.edge distance to mortar joints,additional concrete anchors 21 F 13 ' ? may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. 6 ° 3. Concrete anchor table: 31 26 lu,s•.y;::•::;:;;;;;.;>,.;:;:;::;::;: .;;.;•::::.::.::.:::.....•: ;..::/{kA'NC✓ :'tiK1YY CLpAkANcEANCH�(� ANCHok J41jN MTO MASI7NRY TO ADJACENT _ MBEbEN _........EDGE..... ...........ANG}IOR... .. 8 13 Z a ........ o Dare:'02116112lTW z TAPCON® 2" 4" WALE ° N.T.S. M BY: JK m s E ® 1/4" 1-1/4, 1" 4" ULTRACON cxk.BY: LFS 3 HINGE JAMB STRIKE PLATE DETAIL WOOD SCREW INSTALLATION NOTES: ow,wIxc N6.-.'— Maintain o.:Maintain a minimum 5/W edge distance,I"end distance,R i"o.c.spacing of FL-15213.1 0 wood screws to prevent the splitting of wood. sxEer 5 OF 7 c O�`` T / N I C rJ Z 10) �ifln p 1 �M ,--g�m z v 30 "N ^ q v_ Z o Z U a TYP.HEAD& H g 9 o L a y ^ JAMBS \," �' a "� M a.a V BU K � eg $Z Opt N ^ O FRAME C.0(r CJO ?Z H � �?D 00 C MASONRY "N Lio o OPENING Z am!Q �O s x = o O ~ m o a a x LLp UV mU En O O a v N z it y Z HINGE AMB FRAMEANCHORING STRIKE JAMB 8 g Masonry 1 X buck construction m CONCRETE ANCHOR NOTES: 1.Concrete anchorloca}lora of the co ay be fasted to maintain the min. edge distance to mortar faints. 2.Concrete onchorlocations noted as MAX.ON CEM ust be adjusted to $ maintain the min.edge distance to mortorjoints,addrf' I concrete anchors a a i V maybe required to ensure the"MAX.ON CENTER"dimensf arenot exceeded. 1 >> z g 3.Concrete anchor table: �h {JCHOf{ ANCNCSR /V[I�1, MIN a{EARAMCE M ELEARANCF 31 N 33 .....TYPE SiTE EM6LDMENT Tl)MASONRY TOA CENT.„ c *o m .. .. . ..... ... .. ...... EDGE ...:...... .......ANCHO ..:. �$ 27 w o a TAP ON® 1/4" 1.1/4" T 4" DATE:-02116112 i ELCO ULTRA ON 1/4" 1-1/4" 1" 4" SUM N.t.S. I On.er: JK a s ITW ® 3/16" 1.1/4" 3" 3 e TAPCON HINGE JAMB STRIKE PLATE DETAIL cHx a- WOOD SCRL W INSTALLATION NOTES: DRWNO NO.: N I.Maintain a minimum 5/8"edge distdnce,1"end distance,&i"o.c.spacing of - FL-152 73.1 13 woad screws to prevent the splitting of wood. SHEET 6 Or 7 N b d BILL OF MATERIALS REM DESCRIPTION MATERIAL 1 MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE =a.- 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 2 1 X BUCK SG>=0.55 WOOD 2X BUCK X$SHIM SPACE WOOD ','i'�i `` `` z 00 5 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL �" = ��I/III 0 n•.11 Z 6 #10x2-1/2°PFH WOOD SCREW 1.15"MIN.EMBEDMENT STEEL g v z c z°v 8 #9 x 3/4"PFH WOOD SCREW STEEL F„ 9 m 1?w 9 DOOR SKIN MIN.0.07S'THICK FIBERGLASS '^ �' e g 5°t m IL 10 INSWING VINYL DOOR BOTTOM SWEEP BY ENDURA VINYL �± 4.56" 456° a "� m d a 10A VINYL DOOR BOTTOM SWEEP#3628 BY HOLM IND. VINYL ° d O ti E 11 REINFORCEMENT WOOD FOR LOCK WOOD '•^ '".'; . 12 FINGER JOINTED PINE JAMB WOOD a 13 #9 x 2-1/4"PFH WOOD SCREW STEEL 2.17 ---� 2.12" --�� 14 BOTTOM RAIL CELLULAR PVC 2 4„ c 15 INSWING ADJUSTABLE THRESHOLD BY ENDURA ALUM./WOOD 243 `3 15A INSWING ADJUSTABLE'ALUMINUM THRESHOLD BY DLP ALUM./WOOD ?o ¢w 16 FORCE 5 WEATHER STRIPPING BY ENDURA FOAM 12 JAMB 23 POLYFIBERJAMB o(n •• ¢o 16A COMPRESSION WEATHER STRIP QLON 650 BY SCHLEGEL FOAM 17 KWIKSETKEYED ENTRY-SIGNATURE SERIES STEEL W in og 18 KWIKSETDEADBOLT-SIGNATURE SERIES 780 STEEL a mat 20 POLYURETHANE FOAM BY NANYA POLYURETHANE �I m � 21 4"x 4"BUTT HINGE STEEL g 4 23 POLY FIBER JAMB COMP./VINYL a a 24 HINGE&LATCH STILE CELLULAR PVC — m €� 25 TOP RAIL CELLULAR PVC 4.56" —{ 4.56" 26 DEADBOLT STRIKE PLATE STEEL I 27 LATCH STRIKE PLATE STEEL ell!l 28 OUTSWING BUMP THRESHOLD ALUM./WOOD „a 6' 29 1 HINGE&LATCH STILE REINFORCEMENT LVL 1-2 30 114'X 3-3/4"PFH ITW CONCRETE SCREW STEEL y z � 31 #9 x 1"PFH WOOD SCREW STEEL Iu E) 32 114'x 3-1/4"PFH ITW CONCRETE SCREW STEEL 33 3/16"X 3-1/4"PFH ITW CONCRETE SCREW STEEL IgA ADJUSTABLE INSWING SILL 28 OUISWING BUMP THRESHOLD 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS t �o ^� B w q N r o 5.62" ovo � Z ai DATE:02/16/12 °z_ s34 SME: .N. a NO.BY: JK S 15 ADJUSTABLE INSWING SILL otuwwc HO.: ro FL-15213.1 n b SHEEP 7 OF 7 6 d