Loading...
HomeMy WebLinkAboutWind Load Calculation A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE OPENING (Location) IS THIS A WINDOW PRODUCT LOCATION Corner Zone WINDOW GLAZING ACCEPTANCE APPROVED PRESSURE RATING DESIGN PRESSURE M OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER (+)PSF (-)PSF (+)PSF (-)PSF TESTED IZEDIMENSIONS MULLION REQ Y/N REQ Y/N/NA 1 Int W 7/8°IMP 18-0911.04 55 55 35.5 38.7 74 X 63 73.13x49.63 N N 2 Int W lis"IMP 18-0.918.04 55 55 37.8 41.0 55 X 79 35.63x37.25 N N 3 Int W lis"IMP 18-0911.04 55 55 36.2 39.4 74 X 63 72.88x37.38 N N 4 Int W lis°IMP 18-0911.04 55 55 35.6 38.8 74 X 63 72.63x49.25 N N 5 Int W 7/8"IMP 18=0.918.04 55 55 37.8 41.0 55 x 79 36.0007.00 N N 6 End W 7/8"IMP 18:=0918.04 55 55 37.8 50.6 55 X 79 35.75x37.25 N N 7 Int W 7/8"IMP ',`18=0911.04 55 55 36.2 39.4 74 X 63 72.88x37.38 N N 8 End W 7/8"IMP -0911.04 55 55 35.5 46.1 74 X 63 73.25x49.63 N N 9 Int W 7/8"IMP 1'8-0918.04 55 55 37.8 41.0 55 X 79 36.13x37.25 N N 10 Int W 7/8"IMP 18-0911.04 55 55 36.2 39.4 74 X 63 73.0007.38 N N u: ! . `° m cis O C M 3 rt 3 RECEIVED SP 17 2019 ST. Lucie County, Permitting �IGmH STMT 500 SW 12th Ave - Deerfield Beach, FL 33442 IL N Ph. 561-922-6747 WIN OWS. Fax.661-292-3562 Property Information Building Information Owner: ENGLAND,GEORGE&KATHERINE Wind Zone: 170 MPH. Address: 5600 PALMETTO DR Exposure Category: C FORT PIERCE,FL 34982 Minimum Building Dimension: 15 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 73.13 49.63 7 35.5 -38.7 _.._.__._.... -._._....__. ......--................._...............-._................._....---....................................-....... _.........--......._....._._............._._....................- ----..._......._............._......---............_.-........._......- 2 Int 35.63 37.25 7 37.8 -41.0 ---._............-- ---.._... _..-- -- --- ...................... 3 Int 72.88 , 37.38 7 36.2 -39.4 . . _...-......_..............---............................_._...........__._..............._.......................----..........._........................................_....----............................._................_-........................:.............._..............._ .......................__...........---..................................__....----.................---._..........._....... ..--- 4 Int 72.63 49.25 7 35.6 -38.8 - -- ..-........................__....- -- -..._.._........._...._......-........------.._...... - 5 Int 36.00 37.00 7 37.8 -41.0 .............................................._._._......................................................................_.........................................._....-_.....................__._......._... .._............_..........._..._...__......._.....-..__........................................_...............-:-............_.................-----......................_................_..._............._............... ......----... 6 End 35.75 37.25 7 37.8 -50.6 --............_..___- -- --._.._.................._..._..__.._...._...._.._....... - --.....----........__._.._. ._...._........_ _ 7 Int 72.88 37.38 7 36.2 -39.4 --...._.__....---..._._....._......_..._.- -....._._.._....--- - -- =--...._...---...__....---...._............................................._.._............----..........................-- . ..............__.._ ..__.......- . 8 End 73.25 49.63 7 35.5 -46.1 9 Int 36.13 37.25 7 37.8 -41.0 10 Int 73.00 37.38 7 36.2 -39.4 FILL Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1