HomeMy WebLinkAboutWind Load Calculation Florida Window & Door Co.
1125 N.Dixie Hwy Tel.(561)848-4900
Lake Worth,FL 33460 floridawindowanddoor.com
Property Information Building Information
Owner: John Marsh Wind Zone: 160 MPH.
Address: 7705 Palomar Street Exposure Category: C
Fort Pierce,FL 34951 Minimum Building Dimension: 30 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive IF Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(ps fl PressureIL (psf)
1 End 111 50 7 30.5 -39.0
2 End 37 38 7 33.5 -44.8
3 End 37 38 7 33.5 -44.8
4 End 37 38 7 33.5 -44.8
5 End 72 80 7 30.5 -38.8
6 End 26 38 7 33.5 -44.8
7 End 74 38 7 32.0 -41.9
8 End 37 38 7 33.5 -44.8
9 End 74 38 7 32.0 -41.9
10 End 37 38 7 33.5 -44.8
11 End 74 38 7 32.0 -41.9
12 End 37 38 7 33.5 -44.8
13 End 37 38 7 33.5 -44.8
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code.
Page 1 of 1