Loading...
HomeMy WebLinkAboutTri Built Syn Underlayment Florida NOACREEK Technical Services, LLC GGI18001 FL23888 Page 1 of 2 Page 1 of 2 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6TH EDITION (2017) Manufacturer: TRI-BUILT Materials Group Issued February 12, 2018 9050 Louisiana Street Merrillville, IN 46410 (800) 516-1485 www.tribuiltmaterialsgroup.com Manufacturing Locations: Hangzhou, China Quality Assurance: PRI Construction Materials Technologies (QUA9110) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1, 1518.4 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) GGI-176-02-01.3 ASTM D 226 ASTM D 1970 2009 2015a PRODUCT DESCRIPTION TRI-BUILT® Synthetic Hybrid Roof Underlayment A mechanically attached, synthetic underlayment used an alternative to ASTM D 226, Type I and Type II roofing underlayments. The roll is available in 37.25-inch wide x 145-ft long format and weighs approximately 40 lbs with a minimum tear strength per ASTM D 4533 of 20 pounds. LIMITATIONS 1)Fire Classification is not within the scope of this evaluation. 2)Wind uplift resistance is not within the scope of this evaluation. 3)Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4)Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5)Roof slope limitations shall be in accordance with FBC requirements. 6)Contact the manufacturer when installing at temperatures below the minimum application temperature. 7)The underlayment may be used as described in other current FBC product approval documents. 8)Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 9)The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated. 10)All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. A CREEK Technical Services, LLC GGI18001 FL23888 Page 2 of 2 Page 2 of 2 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TRI-BUILT MATERIALS GROUP Synthetic Hybrid Roof Underlayment APPLICATION INSTRUCTIONS Deck Type: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing construction. Sheathing shall be installed in accordance with FBC requirements. New construction in the HVHZ shall be minimum 19/32 -inch plywood. Roof decks shall have no more than 1/8” gap at abutting joints. Attachment method (Non-HVHZ): Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and manufacturer’s installation instructions. Attachment method (HVHZ): Underlayment shall be installed with a minimum 4-inch head lap and minimum 6-inch end lap and be fastened as specified in FBC Section 1518.2. Allowable roof coverings (Non-HVHZ): Mechanically attached roof systems as prescribed in FBC Section 1507.1.1. Allowable roof coverings (HVHZ): Mechanically attached asphalt shingles, composite shingles, metal roof panels and shingles, or wood shakes and shingles COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT