Loading...
HomeMy WebLinkAboutNOA, Modified Bitumen REVIEWED FOR CO®E COMPLIANCE MIAMI-DADE COUNTY MIAMI�QADE ST. LUOIE COUNTYPRODUCT CONTROL SECTION SOC11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURC (RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy GAF 1 Campus Drive Parsippany,NJ 07054 File COPY SCOPE: This NOA is being issued under the applicable rules and.regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Liberty"'SBS Self-Adhering Modified Bitumen Roofing Systems Over Cementitious Wood Fiber Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its i distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 15-0203.06 and consists of pages 1 through 8. The submitted documentation was reviewed by Jorge L.Acebo. NOA No.: 18-1219.01 M mDADE COUNTY Expiration Date: 04/01/24 "'• • Approval Date: 02/28/19 Page 1 of 8 ROOFING SYSTEM APPROVAL Category: Roofing Sub-Category: Modified Bitumen Material: APP/SBS Deck Type: Cementitious Wood Fiber Maximum Design Pressure: -280 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE L Test Product Product Dimensions Specification Description Liberty'"SBS Self-Adhering 39.375"x 66' ASTM D6163 Self-adhering, SBS modified base or Base/Ply Sheet ply sheet with glass reinforced mat. Ruberoid®SBS Heat-Weld 39.37" ASTM D6164 Non-woven polyester mat coated with Smooth (1 meter)Wide SBS polymer-modified asphalt and smooth surfaced. Ruberoid"SBS Heat-Weld 39.37" ASTM D6164 Non-woven polyester mat coated with Granule (1 meter)Wide SBS polymer-modified asphalt and surfaced with mineral granules. Ruberoid®SBS Heat-Weld 39.37" ASTM D6164 Non-woven polyester mat coated with 170 FR (1 meter)Wide fire retardant SBS polymer modified asphalt and surfaced with mineral granules. Ruberoid®SBS 39.37" ASTM D6164 Non-woven polyester mat coated with Heat-Weld Plus (1 meter)Wide SBS polymer-modified asphalt and surfaced with mineral granules. Ruberoid®SBS Heat-Weld 39.37" ASTM D6164 Non-woven polyester mat coated with Plus FR (1 meter)Wide fire retardant SBS polymer-modified asphalt and surfaced with mineral granules. Ruberoid®EnergyCap'" SBS 39.37" ASTM D6164 Non-woven polyester mat coated with Heat-Weld Plus FR (1 meter) Wide fire retardant SBS polymer-modified asphalt and surfaced with mineral granules with factory applied EnergyCote"'. Ruberoid®Torch Smooth 39.37" ASTM D6222 Non-woven polyester mat coated with (1 meter)Wide APP modified asphalt and smooth surfaced. Tri-Ply®TP-4 39.37" ASTM D6222 Non-woven polyester mat coated with (1 meter)Wide APP modified asphalt and smooth surfaced. Ruberoid®Torch Granule 39.37" ASTM D6222 Non-woven polyester mat coated with (1 meter)Wide APP modified asphalt and surfaced with mineral granules. NOA No.: 18-1219.01 MLAMI•oa pe cout"mr Expiration Date: 04/01/24 Approval Date: 02/28/19 Page 2 of 8 I Test Product Product Dimensions Specification Description RoofMatch" 107 sq. ft. ASTM D6222 Non-woven polyester mat coated with APP Modified Granular (9.9 m2) APP modified asphalt and surfaced with mineral granules. Tri-Ply®TP-4G 39.37" ASTM D6222 Non-woven polyester mat coated with (1 meter)Wide APP modified asphalt and surfaced with mineral granules. Ruberoid®Torch FR 39.37" ASTM D6222 Non-woven polyester mat coated with (1 meter)Wide fire retardant polymer modified asphalt surfaced with mineral granules. Ruberoid®EnergyCap'"Torch 39.37" ASTM D6222 APP modified cap membrane with a Plus FR (1 meter)Wide torch grade bottom surface and a mineral granular top surface coated with factory applied EnergyCoteT". Ruberoid®EnergyCap'"Torch 39.37" ASTM D6222 APP modified cap membrane with a Granule FR (1 meter)Wide torch grade bottom surface and a mineral granular top surface coated with factory applied EnergyCote' GAFGLAS®Mineral Surfaced 39.37" ASTM D3909 Asphalt coated,glass fiber mat cap Cap Sheet (1 meter)Wide sheet surfaced with mineral granules. Tri-Ply®Mineral Surfaced Cap 39.37" ASTM D3909 Asphalt coated, glass fiber mat cap Sheet (1 meter)Wide sheet surfaced with mineral granules. GAFGLASI EnergyCap'"BUR 39.37" ASTM D3909 Asphalt coated, glass fiber mat cap Mineral Surfaced Cap Sheet (1 meter)Wide sheet surfaced with mineral granules and factory applied EnergyCotetm. Topcoat®Membrane 1, 5, 55 gallons ASTM D6083 Acrylic,water based elastomeric membrane system designed to protect j various types of roof surfaces. Topcoat®MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer designed to block asphalt bleed-through. Topcoat®Surface Seal SB 5,55 gallons ASTM D6083 Solvent based sprayable thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase roof reflectivity. Topcoat®FlexSeal'" 1,5 gallons Proprietary Solvent based flashing compound for or gutters and other detailing. 1 qt. tube NOA No.: 18-1219.01 MIAMMADECOUNTY Expiration Date: 04/01/24 • Approval Date: .02/28/19 Page 3 of 8 APPROVED INSULATIONS: TABLE 2 Manufacturer Product Name Product Description (With Current NOA) EnergyGuard'Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuardT"RH Polyiso Insulation Polyisocyanurate foam insulation GAF Securock®Gypsum-Fiber Roof Board Gypsum board US Gypsum Corp. Structodek®High Density Fiberboard High density fiberboard Blue Ridge Fiberboard,Inc. APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name- Description Dimensions (With Current NOA) 1. N/A N/A N/A N/A NOA No.: 18-1219.01 MIAMI•DADE COUNTY Expiration Date: 04/01/24 Approval Date: 02/28/19 Page 4 of 8 EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Identifier Date FM Approvals 4470 J.I.2B8A4.AM 07/02/97 4470 J.I.3B9Q 1.AM 01/08/98 4470 J.I.ODOA8.AM 07/09/99 4470 J.I.OY9Q5.AM 04/01/98 4470 3022139 05/26/05 4470 3044688 03/01/12 UL LLC UL 790 R10689 06/08/18 UL 790 R1306 12/19/16 Trinty I ERD ASTM D6222 G40620.07.12-2-R1 11/07/18 ASTM D6222 G30250.02.10-2 11/11/10 ASTM D6222 G6850.10.08 10/06/08 ASTM D6222 G6850.11.08 02/17/09 ASTM D3909 G30250.02.10-3-R2 06/03/15 ASTM D3909 G6850.08.07-1 08/13/07 ASTM D6862 C8500SC.11.07 11/30/07 ASTM D6164 G6850.08.08-R2 11/20/18 ASTM D4601 G43180.01.14-1 01/10/14 ASTM D6164 G43180.01.14-2A 01/07/14 ASTM D6164 G43180.01.14-2B 01/07/14 ASTM D6164 G43180.01.14-2C 01/07/14 ASTM D6222 G43190.11.13-1 11/15/13 ASTM D6164/D5147 G43180.03.14 03/03/14 ASTM D6222/D5147 G43190.03.14 03/06/14 ASTM D6164/D5147 G40630.03.14 03/06/14 ASTM D6164 G40630.01.14-2A 01/07/14 ASTM D6164 G40630.01.14-2B-Rl 01/16/15 ASTM D6164 G40630.01.14-2C 01/07/14 ASTM D6222 G43190.03.14-1 03/06/14 ASTM D6222/D5147 G43190.03.14-2 03/06/14 ASTM D6222 G43190.05.14-R1 05/20/14 ASTM D3909 G43610.01.14 01/22/14 ASTM D6164 G46160.09.14-3B 11/20/18 ASTM D3909 SC6870.08.14-R1 09/04/14 ASTM D1970 GAF-SC13285.03.17-1 03/08/17 ASTM D1970 GAF-SC16440.12.17 12/31/17 Atlantic&Caribbean Roof TAS 114-D 07-033 05/10/07 Consulting,LLC TAS 114-D 07-081 01/10/08 PRI Construction Technologies LLC ASTM C794 GAF-692-02-01 03/14/16 ASTM D6083 GAF-209-211-02-01 05/05/09 ASTM C1289 GAF-369-02-01 10/22/12 ASTM C1289 GAF-464-02-01 02/06/14 ASTM D6083 GAF-498-02-01 03/14/16 ASTM D6083 GAF-499-02-01 05/19/16 ASTM D6083 GAF-500-02-01 05/19/16 ASTM C1289 GAF-629-02-01 02/29/16 TAS 139 GAF-671-02-01 03/14/16 NOA No.: 18-1219.01 MAMFDADE COUNTY Expiration Date: 04/01/24 Approval Date: 02/28/19 Page 5 of 8 I Membrane Type: APP/SBS, Self-Adhered Deck Type 5I: Cementitious Wood Fiber,Insulated Deck Description: Cementitious Wood Fiber System Type A(1): All layers of insulation and the membrane are adhered. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' Structodek®High Density Fiberboard Minimum 0.5"thick N/A N/A Securock®Gypsum-Fiber Roof Board Minimum 0.25" thick N/A N/A Note: All layers of insulation shall be adhered to the deck with OlyBond 500`x'Adhesive or OlyBond 500®Green beads 3/4" to 1" wide and spaced 6" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base sheet: One ply of LiberV"Self-Adhering Base/Ply Sheet to insulation in accordance with manufacturer's application instructions. Membrane: One or more plies of Ruberoid®SBS Heat-Weld Smooth,Ruberoid®SBS Heat- Weld Granule,Ruberoid®SBS Heat-Weld 170 FR,Ruberoid®SBS Heat-Weld Plus, Ruberoid®SBS Heat-Weld Plus FR or Ruberoid®EnergyCapT°'SBS Heat-Weld Plus FR heat welded with minimum 3.0"wide laps to the self-adhering base/ply sheet in accordance with manufacturer's application instructions. OR One or more plies of Ruberoid®Torch Smooth,Tri-Ply®TP-4,Ruberoid®Torch Granule,RoofMatchT"APP Modified Granular,Tri-Ply®TP4G, Ruberoid®Torch FR,Ruberoid®EnergyCapT"'Torch Plus FR or Ruberoid®EnergyCapT"'Torch Granule FR torch applied with minimum 3.0"wide laps to the self-adhering base/ply in accordance with manufacturer's application instructions Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be in accordance with manufacturer's application instructions. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral Surfaced Cap Sheet,Tri-Ply'Mineral Surfaced Cap Sheet or GAFGLAS'EnergyCapT"BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Topcoat'Membrane,Topcoat®MB Plus(to be used as a primer with Topcoat®Membrane) or Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq. 4. Fibered Aluminum Roof Coating. Maximum Design Pressure: -120 psf. (See General Limitation#9) NOA No.: 18-1219.01 MIAMI•DADECOUNTY Expiration Date: 04/01/24 • Approval Date: 02/28/19 Page 6 of 8 _ i I i Membrane Type: APP/SBS, Self-Adhered I Deck Type 5I: Cementitious Wood Fiber Deck Description: Cementitious Wood Fiber System Type A(2): All layers of insulation and membrane are adhered. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard"'Polyiso Insulation,EnergyGuard"'RH Polyiso Insulation Minimum 1.5" thick N/A N/A Note: All layers of insulation shall be adhered to the deck with OlyBond 500®Adhesive or OlyBond 500®Green beads 3/4" to 1" wide and spaced 8" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base sheet: One ply of LibertyTh` SBS Self-Adhering Base/Ply Sheet to insulation in accordance with manufacturer's application instructions. Membrane: One or more plies Ruberoid®SBS Heat-Weld Smooth,Ruberoid®SBS Heat-Weld Granule,Ruberoid'SBS Heat-Weld 170 FR,Ruberoid®SBS Heat-Weld Plus, Ruberoid®SBS Heat-Weld Plus FR or Ruberoid®EnergyCap- SBS Heat-Weld Plus FR heat welded with minimum 3.0"wide laps to the self-adhering base/ply sheet in accordance with manufacturer's application instructions. OR One or more plies of Ruberoid®Torch Smooth,Tri-Ply®TP-4,Ruberoid®Torch Granule,RoofMatcr APP Modified Granular,Tri-Ply®TP-4G,Ruberoid®Torch FR,Ruberoid®EnergyCapT"'Torch Plus FR or Ruberoid®EnergyCap'Torch i Granule FR torch applied with minimum 3.0"wide laps to the self-adhering base/ply in accordance with manufacturer's application instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be in accordance with manufacturer's application' instructions. 1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 601bs./sq. 2. GAFGLAS®Mineral Surfaced Cap Sheet,Tri-Ply®Mineral Surfaced Cap Sheet or GAFGLAS'EnergyCap'"BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Topcoat®Membrane,Topcoat®MB Plus(to be used as a primer with Topcoat®Membrane)or Topcoat'Surface Seal SB applied at 1 to 1.5 gal./sq. 4. Fibered Aluminum Roof Coating. Maximum Design Pressure: -280 ps£ (See General Limitation#9) I NOA No.: 18-1219.01 MIAMMADECOUNTY Expiration Date: 04/01/24 • Approval Date: 02/28/19 Page 7 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance,refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required.on.all applications over closed cell foam insulations when the base sheet is fully mopped.If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles,24" o.c.; or strip mopped 8"ribbons in three rows,one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6"break shall be placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested,are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchoribase sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,prepared,signed and sealed by a Florida Registered Engineer,Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter hailers,metal profile,and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 18-1219.01 MIAMI•DADE COUNTY Expiration Date: 04/01/24 "'• • Approval Date: 02/28/19 Page 8 of 8