HomeMy WebLinkAboutNOA, Modified Bitumen REVIEWED FOR
CO®E COMPLIANCE MIAMI-DADE COUNTY
MIAMI�QADE ST. LUOIE
COUNTYPRODUCT CONTROL SECTION
SOC11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURC (RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
GAF
1 Campus Drive
Parsippany,NJ 07054 File COPY
SCOPE:
This NOA is being issued under the applicable rules and.regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County
Product Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade
County)reserve the right to have this product or material tested for quality assurance purposes. If
this product or material fails to perform in the accepted manner,the manufacturer will incur the
expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such
product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it
is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Liberty"'SBS Self-Adhering Modified Bitumen Roofing Systems Over
Cementitious Wood Fiber Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an
endorsement of any product,for sales, advertising or any other purposes shall automatically terminate
this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed,then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
i
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 15-0203.06 and consists of pages 1 through 8.
The submitted documentation was reviewed by Jorge L.Acebo.
NOA No.: 18-1219.01
M mDADE COUNTY Expiration Date: 04/01/24
"'• • Approval Date: 02/28/19
Page 1 of 8
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Category: Modified Bitumen
Material: APP/SBS
Deck Type: Cementitious Wood Fiber
Maximum Design Pressure: -280 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE L
Test Product
Product Dimensions Specification Description
Liberty'"SBS Self-Adhering 39.375"x 66' ASTM D6163 Self-adhering, SBS modified base or
Base/Ply Sheet ply sheet with glass reinforced mat.
Ruberoid®SBS Heat-Weld 39.37" ASTM D6164 Non-woven polyester mat coated with
Smooth (1 meter)Wide SBS polymer-modified asphalt and
smooth surfaced.
Ruberoid"SBS Heat-Weld 39.37" ASTM D6164 Non-woven polyester mat coated with
Granule (1 meter)Wide SBS polymer-modified asphalt and
surfaced with mineral granules.
Ruberoid®SBS Heat-Weld 39.37" ASTM D6164 Non-woven polyester mat coated with
170 FR (1 meter)Wide fire retardant SBS polymer modified
asphalt and surfaced with mineral
granules.
Ruberoid®SBS 39.37" ASTM D6164 Non-woven polyester mat coated with
Heat-Weld Plus (1 meter)Wide SBS polymer-modified asphalt and
surfaced with mineral granules.
Ruberoid®SBS Heat-Weld 39.37" ASTM D6164 Non-woven polyester mat coated with
Plus FR (1 meter)Wide fire retardant SBS polymer-modified
asphalt and surfaced with mineral
granules.
Ruberoid®EnergyCap'" SBS 39.37" ASTM D6164 Non-woven polyester mat coated with
Heat-Weld Plus FR (1 meter) Wide fire retardant SBS polymer-modified
asphalt and surfaced with mineral
granules with factory applied
EnergyCote"'.
Ruberoid®Torch Smooth 39.37" ASTM D6222 Non-woven polyester mat coated with
(1 meter)Wide APP modified asphalt and smooth
surfaced.
Tri-Ply®TP-4 39.37" ASTM D6222 Non-woven polyester mat coated with
(1 meter)Wide APP modified asphalt and smooth
surfaced.
Ruberoid®Torch Granule 39.37" ASTM D6222 Non-woven polyester mat coated with
(1 meter)Wide APP modified asphalt and surfaced
with mineral granules.
NOA No.: 18-1219.01
MLAMI•oa pe cout"mr Expiration Date: 04/01/24
Approval Date: 02/28/19
Page 2 of 8
I
Test Product
Product Dimensions Specification Description
RoofMatch" 107 sq. ft. ASTM D6222 Non-woven polyester mat coated with
APP Modified Granular (9.9 m2) APP modified asphalt and surfaced
with mineral granules.
Tri-Ply®TP-4G 39.37" ASTM D6222 Non-woven polyester mat coated with
(1 meter)Wide APP modified asphalt and surfaced
with mineral granules.
Ruberoid®Torch FR 39.37" ASTM D6222 Non-woven polyester mat coated with
(1 meter)Wide fire retardant polymer modified
asphalt surfaced with mineral
granules.
Ruberoid®EnergyCap'"Torch 39.37" ASTM D6222 APP modified cap membrane with a
Plus FR (1 meter)Wide torch grade bottom surface and a
mineral granular top surface coated
with factory applied EnergyCoteT".
Ruberoid®EnergyCap'"Torch 39.37" ASTM D6222 APP modified cap membrane with a
Granule FR (1 meter)Wide torch grade bottom surface and a
mineral granular top surface coated
with factory applied EnergyCote'
GAFGLAS®Mineral Surfaced 39.37" ASTM D3909 Asphalt coated,glass fiber mat cap
Cap Sheet (1 meter)Wide sheet surfaced with mineral granules.
Tri-Ply®Mineral Surfaced Cap 39.37" ASTM D3909 Asphalt coated, glass fiber mat cap
Sheet (1 meter)Wide sheet surfaced with mineral granules.
GAFGLASI EnergyCap'"BUR 39.37" ASTM D3909 Asphalt coated, glass fiber mat cap
Mineral Surfaced Cap Sheet (1 meter)Wide sheet surfaced with mineral granules
and factory applied EnergyCotetm.
Topcoat®Membrane 1, 5, 55 gallons ASTM D6083 Acrylic,water based elastomeric
membrane system designed to protect j
various types of roof surfaces.
Topcoat®MB Plus 5 or 55 gallons Proprietary Water based, low VOC
primer designed to block asphalt
bleed-through.
Topcoat®Surface Seal SB 5,55 gallons ASTM D6083 Solvent based sprayable thermoplastic
rubber sealant designed to protect and
restore aged roof surfaces and to
increase roof reflectivity.
Topcoat®FlexSeal'" 1,5 gallons Proprietary Solvent based flashing compound for
or gutters and other detailing.
1 qt. tube
NOA No.: 18-1219.01
MIAMMADECOUNTY Expiration Date: 04/01/24
• Approval Date: .02/28/19
Page 3 of 8
APPROVED INSULATIONS:
TABLE 2
Manufacturer
Product Name Product Description (With Current NOA)
EnergyGuard'Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuardT"RH Polyiso Insulation Polyisocyanurate foam insulation GAF
Securock®Gypsum-Fiber Roof Board Gypsum board US Gypsum Corp.
Structodek®High Density Fiberboard High density fiberboard Blue Ridge Fiberboard,Inc.
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name- Description Dimensions (With Current NOA)
1. N/A N/A N/A N/A
NOA No.: 18-1219.01
MIAMI•DADE COUNTY Expiration Date: 04/01/24
Approval Date: 02/28/19
Page 4 of 8
EVIDENCE SUBMITTED:
Test Agency/Identifier Name Report Identifier Date
FM Approvals 4470 J.I.2B8A4.AM 07/02/97
4470 J.I.3B9Q 1.AM 01/08/98
4470 J.I.ODOA8.AM 07/09/99
4470 J.I.OY9Q5.AM 04/01/98
4470 3022139 05/26/05
4470 3044688 03/01/12
UL LLC UL 790 R10689 06/08/18
UL 790 R1306 12/19/16
Trinty I ERD ASTM D6222 G40620.07.12-2-R1 11/07/18
ASTM D6222 G30250.02.10-2 11/11/10
ASTM D6222 G6850.10.08 10/06/08
ASTM D6222 G6850.11.08 02/17/09
ASTM D3909 G30250.02.10-3-R2 06/03/15
ASTM D3909 G6850.08.07-1 08/13/07
ASTM D6862 C8500SC.11.07 11/30/07
ASTM D6164 G6850.08.08-R2 11/20/18
ASTM D4601 G43180.01.14-1 01/10/14
ASTM D6164 G43180.01.14-2A 01/07/14
ASTM D6164 G43180.01.14-2B 01/07/14
ASTM D6164 G43180.01.14-2C 01/07/14
ASTM D6222 G43190.11.13-1 11/15/13
ASTM D6164/D5147 G43180.03.14 03/03/14
ASTM D6222/D5147 G43190.03.14 03/06/14
ASTM D6164/D5147 G40630.03.14 03/06/14
ASTM D6164 G40630.01.14-2A 01/07/14
ASTM D6164 G40630.01.14-2B-Rl 01/16/15
ASTM D6164 G40630.01.14-2C 01/07/14
ASTM D6222 G43190.03.14-1 03/06/14
ASTM D6222/D5147 G43190.03.14-2 03/06/14
ASTM D6222 G43190.05.14-R1 05/20/14
ASTM D3909 G43610.01.14 01/22/14
ASTM D6164 G46160.09.14-3B 11/20/18
ASTM D3909 SC6870.08.14-R1 09/04/14
ASTM D1970 GAF-SC13285.03.17-1 03/08/17
ASTM D1970 GAF-SC16440.12.17 12/31/17
Atlantic&Caribbean Roof TAS 114-D 07-033 05/10/07
Consulting,LLC TAS 114-D 07-081 01/10/08
PRI Construction Technologies LLC ASTM C794 GAF-692-02-01 03/14/16
ASTM D6083 GAF-209-211-02-01 05/05/09
ASTM C1289 GAF-369-02-01 10/22/12
ASTM C1289 GAF-464-02-01 02/06/14
ASTM D6083 GAF-498-02-01 03/14/16
ASTM D6083 GAF-499-02-01 05/19/16
ASTM D6083 GAF-500-02-01 05/19/16
ASTM C1289 GAF-629-02-01 02/29/16
TAS 139 GAF-671-02-01 03/14/16
NOA No.: 18-1219.01
MAMFDADE COUNTY Expiration Date: 04/01/24
Approval Date: 02/28/19
Page 5 of 8
I
Membrane Type: APP/SBS, Self-Adhered
Deck Type 5I: Cementitious Wood Fiber,Insulated
Deck Description: Cementitious Wood Fiber
System Type A(1): All layers of insulation and the membrane are adhered.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
Structodek®High Density Fiberboard
Minimum 0.5"thick N/A N/A
Securock®Gypsum-Fiber Roof Board
Minimum 0.25" thick N/A N/A
Note: All layers of insulation shall be adhered to the deck with OlyBond 500`x'Adhesive or
OlyBond 500®Green beads 3/4" to 1" wide and spaced 6" o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Base sheet: One ply of LiberV"Self-Adhering Base/Ply Sheet to insulation in accordance with
manufacturer's application instructions.
Membrane: One or more plies of Ruberoid®SBS Heat-Weld Smooth,Ruberoid®SBS Heat-
Weld Granule,Ruberoid®SBS Heat-Weld 170 FR,Ruberoid®SBS Heat-Weld Plus,
Ruberoid®SBS Heat-Weld Plus FR or Ruberoid®EnergyCapT°'SBS Heat-Weld Plus
FR heat welded with minimum 3.0"wide laps to the self-adhering base/ply sheet in
accordance with manufacturer's application instructions.
OR
One or more plies of Ruberoid®Torch Smooth,Tri-Ply®TP-4,Ruberoid®Torch
Granule,RoofMatchT"APP Modified Granular,Tri-Ply®TP4G, Ruberoid®Torch
FR,Ruberoid®EnergyCapT"'Torch Plus FR or Ruberoid®EnergyCapT"'Torch
Granule FR torch applied with minimum 3.0"wide laps to the self-adhering base/ply
in accordance with manufacturer's application instructions
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be in accordance with manufacturer's application
instructions.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
approved asphalt at 60 lbs./sq.
2. GAFGLAS®Mineral Surfaced Cap Sheet,Tri-Ply'Mineral Surfaced Cap Sheet or
GAFGLAS'EnergyCapT"BUR Mineral Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. Topcoat'Membrane,Topcoat®MB Plus(to be used as a primer with Topcoat®Membrane)
or Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq.
4. Fibered Aluminum Roof Coating.
Maximum Design
Pressure: -120 psf. (See General Limitation#9)
NOA No.: 18-1219.01
MIAMI•DADECOUNTY Expiration Date: 04/01/24
• Approval Date: 02/28/19
Page 6 of 8
_ i I
i
Membrane Type: APP/SBS, Self-Adhered
I
Deck Type 5I: Cementitious Wood Fiber
Deck Description: Cementitious Wood Fiber
System Type A(2): All layers of insulation and membrane are adhered.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
EnergyGuard"'Polyiso Insulation,EnergyGuard"'RH Polyiso Insulation
Minimum 1.5" thick N/A N/A
Note: All layers of insulation shall be adhered to the deck with OlyBond 500®Adhesive or
OlyBond 500®Green beads 3/4" to 1" wide and spaced 8" o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Base sheet: One ply of LibertyTh` SBS Self-Adhering Base/Ply Sheet to insulation in accordance
with manufacturer's application instructions.
Membrane: One or more plies Ruberoid®SBS Heat-Weld Smooth,Ruberoid®SBS Heat-Weld
Granule,Ruberoid'SBS Heat-Weld 170 FR,Ruberoid®SBS Heat-Weld Plus,
Ruberoid®SBS Heat-Weld Plus FR or Ruberoid®EnergyCap- SBS Heat-Weld Plus
FR heat welded with minimum 3.0"wide laps to the self-adhering base/ply sheet in
accordance with manufacturer's application instructions.
OR
One or more plies of Ruberoid®Torch Smooth,Tri-Ply®TP-4,Ruberoid®Torch
Granule,RoofMatcr APP Modified Granular,Tri-Ply®TP-4G,Ruberoid®Torch
FR,Ruberoid®EnergyCapT"'Torch Plus FR or Ruberoid®EnergyCap'Torch i
Granule FR torch applied with minimum 3.0"wide laps to the self-adhering base/ply
in accordance with manufacturer's application instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be in accordance with manufacturer's application'
instructions.
1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq.respectively in a flood coat of
approved asphalt at 601bs./sq.
2. GAFGLAS®Mineral Surfaced Cap Sheet,Tri-Ply®Mineral Surfaced Cap Sheet or
GAFGLAS'EnergyCap'"BUR Mineral Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. Topcoat®Membrane,Topcoat®MB Plus(to be used as a primer with Topcoat®Membrane)or
Topcoat'Surface Seal SB applied at 1 to 1.5 gal./sq.
4. Fibered Aluminum Roof Coating.
Maximum Design
Pressure: -280 ps£ (See General Limitation#9)
I
NOA No.: 18-1219.01
MIAMMADECOUNTY Expiration Date: 04/01/24
• Approval Date: 02/28/19
Page 7 of 8
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance,refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using
the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt,panel size shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required.on.all applications over closed cell
foam insulations when the base sheet is fully mopped.If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles,24" o.c.; or strip
mopped 8"ribbons in three rows,one at each side lap and one down the center of the sheet allowing a
continuous area of ventilation. Encircling of the strips is not acceptable. A 6"break shall be placed
every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a
minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested,are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchoribase sheet or membrane attachment is based on
a minimum fastener resistance value in conjunction with the maximum design value listed within a
specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing,prepared,signed and sealed by a Florida Registered
Engineer,Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA,General Limitation#9 will not be
applicable.)
8. All attachment and sizing of perimeter hailers,metal profile,and/or flashing termination designs shall
conform with Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e.
field,perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones(i.e.perimeters,extended corners and corners).
(When this limitation is specifically referred within this NOA,General Limitation#7 will not be
applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE