Loading...
HomeMy WebLinkAboutProduct Approval EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION 16 GA.5V-CRIMP PANEL' FLORIDABUILDINGCODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 14645:2=R3 ROOFING q r 61; �rr`,vr_r METAL ROOFING I REVIEWED FOR SEP i CODE COMPLIANCE 5T. Lucle County,Permi�ing ST. LUCIE COUNTY Prepared For: OCC Metal Sales 1VIanufacturing Corporation 545 South 3rd Street, Suite 200 Louisville,KY 40202 Telephone: (502)855-4300 Fax! (502)855-4200 File C-O O Prepared By: ?' Bala Sockalingam,.Ph.D.,P.E. Florida Professional Engineer#6224:0 1216 N Lansing Ave., Suite C Tulsa,OK 74.106 Telephone: (91.8)492-5992 FAX: (918)493=3568 This report consists of Evaluation Report(3 Pages including cover) Installation Details (1 Page) � �eotc�e�arr�eo 0 e�o�e P SOCK,4 4 0 •.2 o No 62240 d � _jam • o Report No. C2182-2 3; :cc-z- STATE OF 441 Date: 9.9.17 0,�• w.� OR1VP�\�wAl- `o ens a®90 C�. 20 l"7 FL 14645.2-R3 C2182-2 9.9.17 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel(ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" plywood or min. 3/a" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c. (Minimum) in the field and edges. Designed as per FBC 2017. Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1 Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 84.5 psf @ fastener spacing of 24" o.c. (Factor of Safety=2) 131.3 psf @ fastener spacing of 18" o.c. 149.6 psf @ fastener spacing of 12" o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". At panel ends 6 fasteners per panel width. (4 located adjacent to ribs and 2 between ribs) At intermediate 4 fasteners per panel width. (4 located;adjacent to ribs) Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current FL 14645.2-R3 C2182-2 9.9.17 Page 3 of 3 approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T235-07,Reporting Date 7/12/07 Project No. TI 72-08,Reporting Date 4/29/08 h` Y oanrm er: oacuo er: as os R01: WTE• PANEL FASTENER SPACING 1'1 '/21/1. SV—CRIMP SEE DETAIL 1 PER ALLOWABLE PRESSURE k TABLE ON THIS SHEET. g yWn n MIN. 2X_ WOOD RAFTER/JOIST/ W8 n 1 u UNDERLAYMENT SHALL BE INSTALLED MINIMUM ATTACHMENT: 19/32�DTHICK (MIN.) AS PER MANUFACTURERS INSTALLATION 8d x 2.5" LONG RING SHANK NAIL GUIDELINES OR x 2" LONG WOOD SCREWS TRUSS AT MAX. 24' O.C. SPACED ® 6" O.C. IN THE FIELD & AT PLYWOOD EDGES FASTENER PATTERN AT INTERMEDIATE LOCATIONS 24" d SV-CRIMP SEE DETAIL 1 U N 0 M 7MIN. GUIDELINES =UNDERL MENT SHALL BE INSTALLED PLYWOOD AS PER MANUFACTURER'S INSTALLATION MINIMUM ATTACHMENT: 19/32' THICK (MIN.) IIJ2.5" LONG RING SHANK NAIL >N2X_ WOOD RAFTER/JOIST/ OR #8 x 2" LONG WOOD SCREWS D0o TRUSS AT MAX. 24" O.C. SPACED @ 6" O.C. IN THE FIELD & pp ATPLYWOOD EDGES FASTENER PATTERN AT PANEL ENDS <� TYPICAL PANEL INSTALLATION X-SECTION ALLOWABLE UPLIFT PRESSURE FASTENER PRESSURE nl SPACING (PSF) ZdZ °- (IN) Q c #9-16 OR #10-14 WOODSCREWS a WITH SELF SEALING WASHER AT 24 64.5 a IL m MAXIMUM SPACING OF 24" O.C. U oxo 18 131.3 Ug 5V-CRIMP 12 149.6 S MIN 26 GA. GENERAL NOTIES@ IN 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE NJ FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (1 = 0.017'). EFFECTIVE COVERING WIDTH OF PANEL = 24". tz 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. UNDERLAYMENT PLYWOOD 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS 19/32"THICK (MIN.) PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA CODE. IF AUM DETAIL 1 REQUIIREMENTS NG OF THISDIFFERENCE DRAW NG &O THE OCCURS CODE,THENCODE STHEIHALIL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS -Z 218SHEV REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. sH 2 2 1 OF 1