HomeMy WebLinkAboutProduct Approval .
. .
�
~
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate 9fAuthorization*9s43
sssCHRISTIAN STREET,UNIT#za
QOTRINI-ff ERD ED OXFORD,CT 06478
EVALUATION REPORT
GAF 2 4 2M Evaluation Report 01506.01.08-1122
1 Campus Drive F110124-1120
Parsippany` NJ 07054 LST. ----
eeo Date of Issuance;01/03/2008
(000)766-3411 Revision 22:09/20/2017
Scmps:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building [ode and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6 1h Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency, noted
herein and F8C1587.2-7'1/09OS.2.6.1.
ComnmucmCOMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, orprovisions ofthe Code that relate tothe product change.
_____ 'ptauomxzf.-tb|s'Eva|uadon'-Report�by-tha^named-elientconstbutes'a�reen{e��o~notU\�RbbdMrmi _15-Mf�he'^-' '
product changes or the referenced Quality Assurance documentation changes. Trinity IEKD requires a complete
review ofthis Evaluation Report relative toupdated Code requirements-with each Code Cycle.
AovemnSs |smcTheEvs|uaDonReportnumberprooededbythaxvmrds °Trinity|ER0Eva|uated^ maybedisp|ayedin
K U '
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
b provided '
InSpscnOm:Upon neques�acopy ofth�enDre�a|uadonReport shaU epro� � to the uyerbythe manufacturer or
-hsdkstrbutooandshaUbeavaUab|efurinspacOonottheiobsiteattherequestoftheBui|dinQOffidai
This Evaluation Report consists ofpages 1through 6'
U
Prepared by:
LU
� w Rmbe��M.N�m�em' P.E. The m=�mseal ��*����"w�^��
�m�=" Florida Registration No.59166,Florida D6«AxE1983 ' xc
document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity|sno does not have, nor does it intend to uvqmmm or Will it aonv/me, a finvnua| interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
I nobmrtNieminan p.c.does not have nor will acquire,a financial interest i^any company manufacturing o,distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This isubuilding code am|wadpn. Neither Trinity I ERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,ii/was used for permitting or design guidance unless retained
specifically for that purpose.
Q\TRINITY IERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF,have demonstrated compliance with the
following sections of the e Edition (2017) Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4/1507.1.1, Physical Properties ASTM D1970 2015
R905.2.3/R905.1.1
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Entity Examination Reference Date
GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012
PRI(TST 5878) --Physicaal-P-
r6peftles GAF-025-02-01 03/27/2002
PRI(TST 5878). ASTM D3462--,.---_._._,__g6E;Q59�02;IQ1-._ -09/02"/`��2004--------
P r D3462 GAF-080-02-01. 05/25/2005
AM
PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011
PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/199'3
UL(TST 1740) ASTM D3462 99NK43835 01(11/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 01NK06632 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001
UL(TST 1740) ASTM D3161 01NK37122 12/18/2001
UL(TST 1740) ASTM D3462 OINK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CAS367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/66/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL{TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
U L(TST 1740) ASTM D3161,D7158,D3462 OSCA06100 03/13/2008
Exterior Research and Design,LLC. Evaluation Report 01506.0I.08-R22
CerafjImte OfAutharization#9503 EDITION(2017)FSC NON-HVHZ EVALUATION FL10124-RZ0
GAF Asphalt Roof Shingles Revision 22:09/2D/2017
Page 2 of 6
rTFUNI-fYIERD
Entity Examination Reference Date
UL(TST 1740) ASTM D3161,D3462 07CASS908 04/01/2008
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D34,62 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161jD7158,D3462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010
UL(TST 1740) ASTM D3462 10CA07264 05/27/2010
UL(TST 1740) ASTM 153462 IOCA11953 10/29/2010
UL(TST 1740) ASTM 03161,D7158,D3462 1ONK11951 10/30/2010
UL(TST.1740) ASTM D3161,157158,D3462 1ONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 OBCA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASfIVI D3161,157158,D3462 11CA48408 12/09/2011
UL(TST 1740) ASTM D3161,D7158o D3462 IICA48725 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC.(TST-9628) ASTM D3161,D7158,D3462 4786875675 07-/1-7/2015
UL,LLC.(TST 9628) ASTM D3161,07158,D3462 4787434542� _ .----0511712016
UL;LL&-(QUk96-25-)--kaI CWW-rb-r�� Inspection Report,R21,Mobile,A'L 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 10/20/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 11/01/2016
UL,U-C,(QUA 9625) Quality Control Inspection-Report,1121,Shafter;-CA: -11/17/2016
UL,-LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection.Report,R21,Minneapolis,MN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 10/21/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 11/04/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 11/03/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 11./01/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis® WeatherMaxO, Royal Sovereign" and Sentinel" are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot', CamelotO 11, Fortitude"", Glenwood', Grand Canyon", Grand Sequoia", Grand SequoiaO IR,
Grand SequoiaO ArmorShieldym, Monaco', SlennaO, TimberlineO American HarvestO, Timberline"
ArmorShield' 11,Timberline® Natural Shadow®,Timberline-HD®,Timberline" Cool SeriesO,Timberline Ultra
HD®and WoodlandO are fiberglass reinforced,laminated asphalt roof shingles.
4.1.3 SlatelineO is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridgell
ArmorShield Tm Ridge Cap Shingles and Timbertex®Premium Ridge Cap Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R22
Certificate ofAutharization#9503 6TN EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 3 of 6
Y
5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 611320-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions,using minimum four
(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions:
i Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield,
and Woodland require minimum five(5)nails per shingle.
i Slateline requires minimum six(6)nails per shingle.
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal,'special methods of fastening are
required. Contact the GAF for details.
Exterior Research and Design,U.C. Evaluation Report 01506.01.08-R22
Certificate of Authorization#9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-1120
GAF Asphalt Roof Shingles Revision 22:W20/2017
Page 4of6
r
i
Q\TFUNITYIERD
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and
Seal-A-Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with
a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter
beads of Henkel"Loctite PL S30 Roof&Flashing Sealant".
11.5" Sealant
1" (292 mm) 1" Sellanto
{25 mm) (255 in Enduft d'etanch6hii
r _ �►
' .. . 12"
Nail (305 mm)
Clavo .
6 SIT-7 518" Clouer
(168-194 mm)
12"
(305 mm)
6.4:2--Installation of Time6ertex Premium Ridge Cap Shingles shall comply with GAF current published instructions
_ with a mani.mum two_{2�}.--nai minimum_3,Anch>head=diamete►�pershi = -- - o - onn—e orn Pl��
Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
111V — Balm
1" (2w2 mm) V $Qlluttg
�2b
in (25 rttn S-nduitd'i5tanchiSbi
3x..
INa�
CEM {305 turn)
{Snuar
9`
(�rnrcig
(3+35 mm)
6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or
8905.2.5. Staples are not permitted.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R22
Certificate of Authorization#9543 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 5 of 6
TPNIW ERD
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61020-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(847)664-3281
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R22
Cer"Ite of Authorization#3503 EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 6 of 6