HomeMy WebLinkAboutProduct Approval (2) Certificate of Authorization No. 29824 17520 Edinburgh Drive CREEK , Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6"EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS, INC. 'Issued October 19, 2017 P.O.Box 1404 Joplin,MO 64802 (417)624-6644 hfto://www.tamko.com RECEIVED Quality Assurance: UL LLC(QUA9625) SEP 2 4 2019 SCOPE qT ljicop Cnijnt�t, Amr-mittin Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1 Properties: Physical properties PRODUCT DESCRIPTION TAMKOV ASTM Slate ASTM D 6380,Class M,Type 11 underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. TAMKO@ ASTM Tile ASTM D 6380, Class M,Type 11 underlayment constructed-from an organic felt saturated 0 Underlayment With asphalt then coated on both sides with asphalt and surfaced with granules. TAMKO@)Master ASTM D 6380, Class S,Type IV underlayment constructed from an organic felt saturated U Smooth with asphalt then coated on both sides with asphalt and surfaced With a fine mineral. For use in non-HVHZ only. Uj TAMKO@)Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane Guard@ with a mineral surfacing and a removable release film on the adhesive side and removable selvedge release tape. TAMKO@ No.15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKO@)No.16 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKO@ No.30 ASTM ASTM D 226,Type 11 underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKOO No.30 UL ASTM D 226,Type 11 underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKO@ 7W Metal and Self-adhered,flexible,ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. TAMKO&TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. TBP14001.4 FL12328-R8 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. ' ^ ~ ' �~�0����*N��U�� T��x�ouu�mGpRooCuTa.�c. � ��`��.��*K[���� Tvmxmououerlavments TECHNICAL SERVICES,LLC T&MNO@/TAM'FELT Alternate 8oASTM D 226 11 underlayment constructed from a non- perforated organic felt that is saturated with asphalt. APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBQ and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners inthe deck shall be checked for protrusion and corrected prior buundndaymartapplication. The roof deck shall beconstructed ofclosely fitted plywood sheathing for new orexisting construction. Plywood deck ohmU be installed in accordance with F8O requirements. Roof decks shall have no more than 1/8" gap at abutting joints. The minimum |kcaV ^ except osfollows: o) The minimum application temperature o[TAK8KO@ TW Metal and Tile Undedaymertond TAMKOVDTVV Underlaymentaha||be4U=F. b) The minimum application temperature ufTAMNO(0Moisture Guard@ shall be35"F. The minimum roof slope shall bei nd wdhF8C requirements except as follows: o) The minimum slope ofTAK0KD9ASTIMSlate Surfaced Roll Roofing shall bo2:12. Undodaymenta uho|| be exposed in accordance with thammndtctuner'a nauummandoUuno, but in no 000e oheU exposure exceed 30days. Exception: lAMKO@TVVMetal and Tile Undedaymentmay beexposed for omaximum BOdays. Self-adhering unded.aymentsmay be adhered to primed orunphmedplywood substrates inthe non-HVHZ. All roof coverings shall be mechanically fastened through the underlayment to the roof deck. Allowable Roof Coverings: Metal Roof Mineral Wood Underla Asphalt Panels and SurfacedRoll Shingles and Slate Clay and yment Shingles Shingles Roofing -Shakes' Shinales Concrete Tile Surfaced Roll Roofing TAMK()@ ASTM Tile TAMKOO No.15 ASTM Felt TAMKO@ No.IS UL Asphalt Y2 TAMIKOP No.30 ASTM Felt TAMKO@)No.30 UL Asphalt, TAMIKOID TW Metal and Tile Notes: 1)Open valley applications per 1507.2.9.2 2)-Wood shingles only TBp14001.4 pu2328-R8 Page 2 of TAMKO BUILDING PRODCUTS,INC. CREEK TAMKO Underlayments TECHNICAL SERVICES,LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Contact the manufacturer when installing at temperatures below the minimum application temperature. 5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements. 6) All underlayments;shall be installed with the roll length parallel to the eave,starting at the eave,and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 7) The underlayment may be used as described in other current FBC product approval documents. 8) The underlayment shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding specific exposure limits for each underlayment. 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. REFERENCES gn& Report No. Standard Year PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM 0 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM 0 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2010 PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995 ASTM D 4798 2011 PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012 PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a UL LLC(TST9628) 13CA12269 ASTM D 226 2009 TBP14001.4 FL12328-R8 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein.' TAMKO BUILDING PRODCUTS,INC. • CREEK TAMIKO Underlayments TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. E IV 2017.10.19 No 74021 '�'� = 12:15:58 -04'00' -0 STATE OF 44/-Z 4 Zachary R. Priest, P.E. . .. .... r% 0#.; 0 Ft N�-Z Florida Registration No.74021 '�F;l ONA. Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation, CREEK Technical Services,LLC Is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest P.E.does not have,nor will acquire,a financial interest In any company manufacturing or distributing products under this evaluation. Zachary R.Priest P.E.does not have,nor will acquire,a financial interest In any other entity involved in the approval process of the product END OF REPORT TBP14001.4 FL12328-R8 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein.