HomeMy WebLinkAboutProduct Approval (2) Certificate of Authorization No. 29824
17520 Edinburgh Drive
CREEK , Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6"EDITION(2017)
Manufacturer: TAMKO BUILDING PRODUCTS, INC. 'Issued October 19, 2017
P.O.Box 1404
Joplin,MO 64802
(417)624-6644
hfto://www.tamko.com RECEIVED
Quality Assurance: UL LLC(QUA9625) SEP 2 4 2019
SCOPE qT ljicop Cnijnt�t, Amr-mittin
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DESCRIPTION
TAMKOV ASTM Slate ASTM D 6380,Class M,Type 11 underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKO@ ASTM Tile ASTM D 6380, Class M,Type 11 underlayment constructed-from an organic felt saturated
0 Underlayment With asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKO@)Master ASTM D 6380, Class S,Type IV underlayment constructed from an organic felt saturated
U Smooth with asphalt then coated on both sides with asphalt and surfaced With a fine mineral. For
use in non-HVHZ only.
Uj TAMKO@)Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard@ with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKO@ No.15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic Felt
TAMKO@)No.16 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic Felt
TAMKO@ No.30 ASTM ASTM D 226,Type 11 underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic Felt
TAMKOO No.30 UL ASTM D 226,Type 11 underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic Felt
TAMKO@ 7W Metal and Self-adhered,flexible,ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO&TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not
specifically addressed herein.
' ^
~ '
�~�0����*N��U�� T��x�ouu�mGpRooCuTa.�c.
� ��`��.��*K[���� Tvmxmououerlavments
TECHNICAL SERVICES,LLC
T&MNO@/TAM'FELT Alternate 8oASTM D 226 11 underlayment constructed from a non-
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBQ and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners inthe deck shall be
checked for protrusion and corrected prior buundndaymartapplication.
The roof deck shall beconstructed ofclosely fitted plywood sheathing for new orexisting construction. Plywood deck
ohmU be installed in accordance with F8O requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum |kcaV ^ except osfollows:
o) The minimum application temperature o[TAK8KO@ TW Metal and Tile Undedaymertond TAMKOVDTVV
Underlaymentaha||be4U=F.
b) The minimum application temperature ufTAMNO(0Moisture Guard@ shall be35"F.
The minimum roof slope shall bei nd wdhF8C requirements except as follows:
o) The minimum slope ofTAK0KD9ASTIMSlate Surfaced Roll Roofing shall bo2:12.
Undodaymenta uho|| be exposed in accordance with thammndtctuner'a nauummandoUuno, but in no 000e oheU
exposure exceed 30days.
Exception: lAMKO@TVVMetal and Tile Undedaymentmay beexposed for omaximum BOdays.
Self-adhering unded.aymentsmay be adhered to primed orunphmedplywood substrates inthe non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Coverings: Metal Roof Mineral Wood
Underla Asphalt Panels and SurfacedRoll Shingles and Slate Clay and
yment Shingles Shingles Roofing -Shakes' Shinales Concrete Tile
Surfaced Roll Roofing
TAMK()@ ASTM Tile
TAMKOO No.15 ASTM
Felt
TAMKO@ No.IS UL Asphalt Y2
TAMIKOP No.30 ASTM
Felt
TAMKO@)No.30 UL Asphalt,
TAMIKOID TW Metal and Tile
Notes: 1)Open valley applications per 1507.2.9.2
2)-Wood shingles only
TBp14001.4 pu2328-R8 Page 2 of
TAMKO BUILDING PRODCUTS,INC.
CREEK TAMKO Underlayments
TECHNICAL SERVICES,LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturers published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments;shall be installed with the roll length parallel to the eave,starting at the eave,and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
gn& Report No. Standard Year
PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM 0 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM 0 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2010
PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995
ASTM D 4798 2011
PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012
PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a
UL LLC(TST9628) 13CA12269 ASTM D 226 2009
TBP14001.4 FL12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty,Installation,recommended use,or other product attributes that are not
specifically addressed herein.'
TAMKO BUILDING PRODCUTS,INC.
• CREEK TAMIKO Underlayments
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
E IV 2017.10.19
No 74021 '�'� = 12:15:58
-04'00'
-0 STATE OF 44/-Z
4
Zachary R. Priest, P.E.
.
.. .... r%
0#.; 0 Ft N�-Z Florida Registration No.74021
'�F;l ONA. Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this
evaluation,
CREEK Technical Services,LLC Is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest P.E.does not have,nor will acquire,a financial interest In any company manufacturing or distributing products under this evaluation.
Zachary R.Priest P.E.does not have,nor will acquire,a financial interest In any other entity involved in the approval process of the product
END OF REPORT
TBP14001.4 FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.