HomeMy WebLinkAboutProduct Approval (2) 9/17/2019 CJV `� ie Florida Building Code Online
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I Contact Us I' BCIS Site Map Links I Search
a
; ' Product Approval
.USER:Public User
r
db
Product Approval Menu>Product or Application Search>Application List>Application Detail
t
FL# FL10674-R14
Application Type Revision
Code Version 2017 =-RECEIVEDApplication Status Approved
Comments
Archived G ,
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419) 376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC.
Quality Assurance Contract Expiration Date 04/20/2020
Validated By John W. Knezevich, PE
CF' Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R14 COI 2019 01 COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5Vp/o2boQTp/o2b6w7ahReg lCQ8ucR6ixECZJn4MvmV81Q%3d%3d 1/2
9/17/2019 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 06/13/2019
Date Validated 06/18/2019
Date Pending FBC Approval 06/23/2019
Date Approved 08/13/2019
Date Revised 08/15/2019
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles
Shingles and Starters
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10674 R14 II 2019 06 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R14.pdf
Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other: Refer to ER,Section 5. Evaluation Reports
FL10674 R14 AE 2019 06 FINAL ER OC ASPHALT
SHINGLES FL10674-R14.pdf
Created by Independent Third Party: Yes
Back Pext
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::PrivacyStatement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
aw._I ® eCheck
Credit Card',`_ '
Safe:;,:,:
4
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReg]CQ8ucR6ixECZJn4MvmV8]Q%3d%3d 2/2
NEW I etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
REPORTEVALUATION
Owens Corning Evaluation Report 037940.02.12-R9
One Owens Corning Parkway FL10674-1114
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 9: 06/13/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality
Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s),the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "MEMO I etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert J.M. Nieminen,P.E. ,��I^;=q'Sti. ThefaaimllesealappearingwasauthorizedbyRobert
� 's �.4 Nieminen,P.E.on 06/13/2019.This does not serve as an
Florida Registration No.59166,Florida DCA ANE1983 ::.{ .,.,,,,,« electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOIetc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOI etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project
on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically
for that purpose.
MEMO�etc.
ROOFING SYSTEMS EVALUATION:
SCOPE:1.
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 6t'Edition(2017)Florida Building Code and Florida
Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
; Section .';. Pro a Standard Year.
1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
E
nti Exarriinatlon Reference Date'
PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
PRI(QUA9110) Quality Control Service Confirmation 04/05/2020
PRODUCT4. DESCRIPTION:
4 1: ACCESSORY STARTERS.
4.1.1 Starter Strip Shingle and Starter Strip Plus are starter strips for asphalt roof shingles. Meets ASTM D3462.
4.1.2 Starter Shingle Roll is a mineral-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen starter strip,
nominal 7.2-inch wide x 33-ft 4-inch long roll,for use with asphalt shingles. Meets ASTM D1970.
4 2.'.-. ASPHALT SHINGLES:
4.2.1 Classic®and Supreme®are fiberglass r
einforced,3-tab asphalt roof shingles. Meets ASTM D3462.
4.2.2 Berkshire®are fiberglass reinforced,4-tab asphalt roof shingles. Meets ASTM D3462.
4.2.3 Duration®,TruDefinition® Duration®, Duration®Premium Cool,TruDefinition® Duration® Designer Color Collection,
TruDefinition® Oakridge', Oakridge® and WeatherGuard® HP are fiberglass reinforced, laminated asphalt roof
shingles. Meets ASTM D3462.
4 3: Hla&.RIDCE:SHwGLEs: - •
4.3.1 Berkshire'Hip&Ridge Shingles with Sealant,DuraRidge®Hip&Ridge Shingles with Sealant,ProEdge®Hip&Ridge
Shingles and WeatherGuard®HP Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
Meets ASTM D3462.
NEMO ETC,LLC Evaluation Report 037940.02.12-R9
Certificate of Authorization 1132455 6-EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1114
Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019
Page 2 of 10
ONEMOJetc.
LIMITATIONS:5.
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Wind Classification:
5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating acceptable use in all wind zones
UP to Vasd=150 mph (Vhit=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.2 Starter Strip Shingle and Starter Strip Plus noted in Section 4.1.1 and the Owens Corning hip&ridge shingles noted
in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F,
indicating acceptable use in all wind zones up to Vasd=150 mph(V,,it=194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
INSTALLATION:6.
61 GENERAL
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof(tear-off) or recover applications,subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6 2 ACCESSORY STARTERS:'•'
6.2.1 Installation of Starter Strip Shingle and Starter Strip Plus shall comply with the Owens Corning current published
instructions,using minimum five(5)nails per strip.
Feltundedayment 'i--Deck Fep undcA+ymcnt D.d, WSdk,6e d
Self-adhered rmdalayment
WeatherLocke
undedaymont
Drip edge
e�dg Drip edge Ddp—
edge
Nails located Nal lowed
2'�'ham cave
2-3-from enva
Install first Seg.seal`mg adhesive hstel6m Shrtar6tripfLe Sdaea�aatie:ireo
Starter Stdp . . \ positioned along eave with F removed \
shingle with .,.
6°removed Starter Strip shingle overhangs eaves and rakes WWI" Shen Stip Pb.mahupseaves and nkn 1/4-310•
Figure 1:Minimum Nailing,Starter Strip Figure 2:Minimum Nailing,Starter Strip Plus
NEMO ETC,LLC Evaluation Report 037940.02.12-R9
Certificate of Authorization#32455 6TH EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1114
Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019
Page 3 of 10
ONEMOjetc.
6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
Deck
Underlayment
Drip edge
Drip edge
f Y
Starter Shingle Roll adhered
-` directly to underlayment and
7 2 primed drip edge
Self-sealing adhesive
positioned along eaves
Figure 3:Starter Shingle Roll
ASPHALT.SHINGLES
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions:
➢ Berkshire'shingles require minimum five(5)nails per shingle.
➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Classic®&Supreme:
Normal Mansard or Area para Normal Mansard or Area para
Wind Areas High Wind desvanes y Wind Areas High Wind desvanes y
Area pare vientos normales Areas vientos fuertes Area para vientos normales Areas vientas fuertes
7' (A) 1.. Fl- 2^ (B r2. 7" 7" (AI �.Z r7. 2" (BI r2. 7.
77" 17" 12 121 _
5"Exposure 5 518"Exposure
Exposicidn Exposicidn
Figure 4:Minimum Nailing,Classic&Supreme Figure 5:Minimum Nailing,Classic&Supreme
(Standard Size) (Metric Size)
NEMO ETC,LLC Evaluation Report 037940.02.12-119
Certificate of Authorization#32455 6m EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1114
Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019
Page 4 of 10
ONEMOletc.
6.3.1.2 Berkshire®:
Sealant strip Sealant strip
L##ia de seiadar La tire de sellador
Yt 9"yt l3 W } 8',A- S eft. B Vz" 8 rft I
t..
Figure 6: 5-Nail Pattern,Berkshire Figure 7: 6-Nail Pattern,Berkshire
Sealamstrip,
La Lira de sellador.
�E--i�a--r• :�.f--t•��—ice
2. :AsphallYroofing cement'
Cements de techii de asfalto
Figure 8: Mansard or Steep Slope Pattern,Berkshire
NEMO ETC,LLC Evaluation Report 037940.02.12-R9
Certificate of Authorizatlon#32455 6-EDITION(2017)FBC NON-HVH2 EVALUATION FL10674-1134
Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019
Page 5 of 10
O. MEMO I etc.
6.3.1.3 Duration® TruDefinition®Duration Duration®Premium Cool&TruDefinition®Duration®Designer Color Collection:
4-Nail Fastening Pattern
SureNail®fastening area width
N�il,]ypical
1 12" 12' 1"
_precis Ca¢in0.5ureYaeu, - _.._•, @ my Eawo�waM.O. ... •' Owerrs Comm SunO •
8-118" .ry5(g..
esposwe
Figure 9:Standard 4-Nail Pattern,Duration
6-Nail Fastening Pattern.
SureNail®fastening area width
Nail,Typical
1" IV, '12" A.
.. jF;i.'n5 Co SweNail ,•' �:.'any 6uwoJ suarp... Owens Coming Surc(:asv •
F777�
8 118" li 518"
eap"sue -
Figure 10: 6-Nail Pattern,Duration
'Fastening for Slopes Greater Than 21:12,
SureNall0 fastening area width
Nall,typical
1" 12" 12" 1"
-gena Cartnn05ufeGa •'.Oxvft Cw J.a Su.Nad®': :•.
&118" 5-518"
osposu�e _ -
T2
Four 1",Spots'of Asphalt Roofing Cement
Figure 11: Mansard or Steep Slope Pattern,Duration
NEMO ETC,LLC Evaluation Report 037940.02.12-R9
Certificate of Authorization#32455 a EDITION(2017)FBC NON-HVH2 EVALUATION FL30674-R14
Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019
Page 6 of 10
ONEMOjetc.
6.3.1.4 Tru Definition'Oakridge®,Oakridge®:
4Nail.Pattern
Esguema con 4 claves:
1" 1^
5518"Exposure.,... 5;518"Exposul,
Nails,
Exposief6hde6.519pufg. Clavo— ;FxposrcOnde6618pitig.
Figure 12:Standard 4-Nail Pattern,Oakridge
6 Nail Pattern
Esgpema con 6 cfavos
1" 1^
Nails.
5 578"Expasuie, CWOS6 6 ran Exposure
Exposid&d0s/8puig. i Exposid6a de 65/801119.Figure 13:6-Nail Pattern,Oakridge
Fastening for Slopes Greater Than 21`12
SureN08 fastening area width
Noll;Typlcal
1" 12"
,:�wnna ca."maamw • 'IiLanwci'�o.. •owm cmmro sux+ar �. 't
8-118"551tS" -
T"
Fcur 1"Spots oTAsphelfRooMg Cement
Figure 14:Mansard or Steep-Slope Pattern,Oakridge
NEMO ETC,LLC Evaluation Report 037940.02.12-R9
Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1114
Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019
Page 7 of 10
ONEMOjetc.
6.3.1.5 WeatherGuard®HP:
I tPig.� tZp 3122
fg_I A.
vft anm
55 518;Egosvn 5 518-Esva
ERpom6bn da 5 5�8 poig. 6cpodcwn do 5 5?B PN%'
Figure 15:6-Nail Pattern,WeatherGuard HP
Mil Pattern
Esquema con 6 claws Nail 6118'from bottom
of shingle
Clave a 6 118 ping.de la
5 518'Exposure 6 Fasteners parte inferior de la t4a
Exposicion de 5 518 pulg. 6 sujetadores
r j1p- 2"
Four 1"Spots of Asphalt Roof Cement
Cuatro puntos de cemento de techo de asfalto de 1 pulgada
Figure 16:Mansard or Steep-Slope Pattern,WeatherGuard HP
6 4:: HIF;&RIDGE,SHINGLES
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
➢ Berkshire® Hip and Ridge Shingles with Sealant and DuraRidge® Hip & Ridge Shingles with Sealant require
minimum two(2) nails per shingle.
➢ WeatherGuard® HP Hip and Ridge Shingles and ProEdge® Hip & Ridge Shingles require minimum four (4)
nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
MEMO ETC,LLC Evaluation Report 037940.02.12-R9
Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVH2 EVALUATION F1.10674-1114
Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019
Page 8 of 10
OMEMO etc.
6.4.1.1 Berkshire®Hip&Ridge with Sealant and DuraRidge®Hip&Ridge Shingles with Sealant:
Fig. A Fig. B
Prevailing Wind Direction Top View
Direcci6n del viento predominante Vista superior
It 1
Nail
25W Clavo
Nails
p I • Omrins Coming SureW,
V'
Clavos
I
A i 8.r I G
[*-B"Exposure d I u
IEgmid6n de a pulg V
I
I
A
120
Figure 17:Isometric View,Berkshire and DuraRidge Figure 18:Plan View,Berkshire and DuraRidge
6.4.1.2 WeatherGuard®HP Hip&Ridge Shingles:
Fig.'A 9 4 Fig:C Hip&Ridge Shingle Fastening
Prevalling Wlnd Top View
Dlrectbn A
A -
Nails 4 4
f? Nails Nails
A I I ���
T . I I 2"-1102'
Exposure
6" 'Exposure
'12"
Figure 19:Isometric View,WeatherGuard HP Hip&Ridge Figure 20:Plan View,WeatherGuard HP Hip&Ridge
NEMO ETC,LLC Evaluation Report 037940.02.12-R9
Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVH2 EVALUATION F1.10674-1114
Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019
Page 9 of 10
NNEMOjetc.
6.4.1.3 ProEdge®Hip&Ridge Shingles:
Prevailing Standard —11'—
Wind Direction Sealant Strip Pattering
6"Exposure 1°►� �•�� ~I•� I.1'
12" I Sealant
Fasten 711 7��` 6"Exposure
Cover Exposed 1
Fasteners with
Roof Cement
Figure 21:Isometric View,ProEdge Figure 22: Plan View,ProEdge
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation
of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3
CIA requirements.
• QUALITY
PRI Construction Materials Technologies, LLC—QUA9110; 813 621-5777; bwilson@pricmt.com
- END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 037940.02.12-119
Certificate of Authorization+x32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1114
Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019
Page 10 of 10