HomeMy WebLinkAboutProduct Approval (2) • File COPY 9tvEWE® FOR RECEIVE® CODE COMPLIANCENEMO I etc. Authorization#32455 SEP 2 7 ?019 ��° �—���� s et, Unit#13 ®!�� e ford,CT 06478 ST. Lucie County, Permitting (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION Owens Corning Evaluation Report 037940.02.12-119 One Owens Corning Parkway FL10674-1114 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 9: 06/13/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). NEW I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. i This Evaluation Report consists of pages 1 through 10. Prepared by: -dry Robert J.M.Nieminen P.E. %�,�,',q:�s :.•• The facsimile seal appearing was authorized by Robert r '.;cSy f�• c' Nieminen,P.E.on 06/13/2019.This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 ";?'r�..°`.���'•`' electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOJetc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. ` S. This is a building code evaluation. Neither NEMO I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6a'Edition(2017)Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. STANDARDS:2. Section Pro a ,_ Standard Year 1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Enti Examination Reference Date _._. .._. _..._.. _.. _., .. .. ., PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various PRI(QUA9110) Quality Control Service Confirmation 04/05/2020 4. '••• DESCRIPTION: 4.1 ACCESSORYSTARTERS: 71 4.1.1 Starter StripShingle and Starter Strip Plus are start* a ,, g p r strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 Starter Shingle Roll is a mineral-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen starter strip, nominal 7.2-inch wide x 33-ft 4-inch long roll,for use with asphalt shingles. Meets ASTM D1970. ASPHALT SHINGLES.� o ` ' 4.2.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.Meets ASTM D3462. 4.2.2 Berkshire*are fiberglass reinforced,4-tab asphalt roof shingles. Meets ASTM D3462. j 4.2.3 Duration*,TruDefinition* Duration*, Duration'Premium Cool,TruDefinition®Duration*Designer Color Collection, TruDefinition*Oakridge, Oakridge* and WeatherGuard* HP are fiberglass reinforced, laminated asphalt roof shingles. Meets ASTM D3462. HIP&R'1bGE SHINGLES:.. 4.3.1 Berkshire*Hip&Ridge Shingles with Sealant,DuraRidge®Hip&Ridge Shingles with Sealant,ProEdge®Hip&Ridge Shingles and WeatherGuard*HP Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. Meets ASTM D3462. NEMO ETC,LLC Evaluation Report 037940.02.12-R9 Certificate of Authorization#32455 9-EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1114 Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019 Page 2 of 10 ONEMOletc. LIMITATIONS:5. 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating acceptable use in all wind zones up to Vasd=150 mph(Vult=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C,as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 Starter Strip Shingle and Starter Strip Plus noted in Section 4.1.1 and the Owens Corning hip&ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating acceptable use in all wind zones up to Vasd=150 mph(Vult=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6 1 GENERAL 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6 2 ACCESSORY STARTERS 6.2.1 instructions,using using minimum five(5)nails per strip. Felt r Plus shall comply with the Owens Corning current published Fdtrmdulaynient Deck w andaure.ar t>e<k wt.r a ed SeU adhtred. Wwalam WeatherLocN tmdo ayawnt ( Drip edpa _ ��0e e Na1s loafed ° Ya°'fromoars Y 3 hamem hMas fast SaEseafmg adhesive edeshe Starterstr'� positioned along eave wMcra or �aMgave shmcle with -.. 6°removed StarttaS*shingle ovedunpssam and rakesW4 Sunee P6 —1t1aK M—Wr*K114 dW Figure 1:Minimum Nailing,Starter Strip Figure 2:Minimum Nailing,Starter Strip Plus NEMO ETC,LLC Evaluation Report 037940.02.12-R9 Certificate of Authorization N32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1114 Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019 Page 3 of 10 fONEMOjetc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Deck Underlayment Drip edge s,d Drip edge E SJ f. Starter Shingle Roll adhered 4 directly to underlayment and primed drip edge Self-sealing adhesive positioned along eaves Figure 3:Starter Shingle Roll 6 , ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. ➢ WeatherGuard'HP shingles require minimum six(6)nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Classic®&Supreme: Normal Mansard or Area psra Normal Mansard or Area pare Wind Areas High Wind desvanes y Wind Areas High Wind desvanes y Area pare vientos normalas Areas vientos faerte3 Area pen vientos normeles Areas vienros fuertes t' (A) 1., F.I. r (B 2• t' t"2 fA► tt^ tr • t t2t . . . . . . . . . . . . . . . . . S"Exposure 6 Wir Exposure Exposicion Exposicidn Figure 4:Minimum Nailing,Classic&Supreme Figure 5:Minimum Nailing,Classic&Supreme j (Standard Size) (Metric Size) NEMO ETC,LLC Evaluation Report 037940.02.12-119 Certifrcote of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1134 Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019 Page 4 of 10 ONEMOletc. 6.3.1.2 Berkshire®: Seabrt strip Sealantswp Lathe da-se kdr.. La fua de sellador 1 8 Vz 9 yz" 9 W $Vt'. "8 pie" 8 7h" 8 rff 8 W, Figure 6: S-Nail Pattern,Berkshire Figure 7: 6-Nail Pattern,Berkshire Seab strIp La tZra de wlkdor :t3Yt 8�P $V 1 `X. 24 Asphalt roof oig:cement Ceiimnfodelecho.de dodd Figure 8: Mansard or Steep Slope Pattern,Berkshire I NEW ETC,LLC Evaluation Report 037940.02.12-119 Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1114 Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019 Page 5 of 10 ONEMOjetc. 6.3.1.3 Duration®,TruDefinition®Duration Duration®Premium Cool&TruDefinitiono Duration*Designer Color Collection: 4-Nail:FasteningPattern SureN"fastenin8 area vu dtli ' Nail,_7ypical - r�,cwierg surety •; .,�.�o �!�s� `r• orn.n candy sm.wa+� ,..o:. r � Figure 9:Standard 4-Nail Pattern,Duration 6-N911.Fastening_PattgM SureNalN0fastening;area wlc th, Nall;lyplcal, 1" 127• 42" 1" -.Wr Scwi g 3—Mi J-,a a••-,,7: -L...:8uwn� Figure 10: 6-Nail Pattern,Duration Fastening fo-r:Slopes:GreaterThan,2112 SureNall®.faetening,area'iwldt6 Nall,Typical 1" 12" 12" 1" r.'pxensCum!nps- 1.%_.;' ae.+5.815utoJ suae+0'c.- - �Oiaem CaNiq SiaeNaln "-ram. exp" '2R 6444 Four 1"Spots'ofAsphalt Rooflng:Cement Figure 11: Mansard or Steep Slope Pattern,Duration I NEW ETC,LLC Evaluation Report 037940.02.12-119 Certificate ojAuthorization#32455 a EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R14 Owens Coming Asphalt Roof Shingles Revision 9:06/23/2019 Page 6 of 10 I ' ONEMOjetc. 6.3.1.4 TruDefinition"Oakridee®,Oakridee®: -4 Na(i Pattern , 'Esquema cor14 davos= i 5$I8e Exposure,.. Nails cfavos. 5 518 Exposure £>rposfdonde5b/Spufg. Exposrc(dnde5&/Bprrlg Figure 12:Standard 4-Nail Pattern,Oakridge G-Naii`t'attem wfta con 6 ctavos . ' tz — Nails: 53/8"Exposure Ctavos '5 518 Exposure - Expos+cfort;de vr5/8pyfg: Fxposrcidride b5/8'pilg. Figure 13:6-Nail Pattern,Oakridge Fastening far Mopes Greater T,han;21:12. SureNan fastening area width Nall,Typical Ir ..P"m CmdC5.�1-.. • ? .MCSdNo1..�0" ^..L cn fanb SSYta1 :�.. t - e.t�" Four v SpotS WAsphelt Roofing Cement i Figure 14:Mansard or Steep-Slope Pattern,Oakridge NEMO ETC,LLC Evaluation Report 037940.02.12-R9 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1114 Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019 Page 7 of 20 ONEMOjetc. 6.3.1.5 WeatherGuard®HP: '� 't�t2p 9�� I� no am E�dc6ti�de 5 68 ping. fitposiC�n do 6 pW�g. Figure 1S:6-Nail Pattern,WeatherGuard HP 6 Nail Pattern Esquema con 6 davos Nail 61/8'from,bottom of,shilgle. $518'Ex wre 8'Fasteners pave a 6118 pping de le po 6 parte infeiorde la t4a Exposici3n de 5 518 pulg. ,suJet rs. 2• t • — Four 1'Spots of Asphalt Roof Cement Cuatro puafos de cemado do tecbo de asfalto de 1 pulgada Figure 16:Mansard or Steep-Slope Pattern,WeatherGuard HP 6.4 HIP'&RIDGE SHINGLES. 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire® Hip and Ridge Shingles with Sealant and DuraRidge® Hip& Ridge Shingles with Sealant require minimum two(2)nails per shingle. ➢ WeatherGuard' HP Hip and Ridge Shingles and ProEdge® Hip & Ridge Shingles require minimum four(4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. NEMO ETC,LLC Evaluation Report 037940.02.12-119 CertifrcateofAuthorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R14 Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019 Page 8 of 10 ONEMOjetc. 6.4.1.1 Berkshire®Hip&Ridge with Sealant and DuraRidge®Hip&Ridge Shingles with Sealant: Fig. A Fig. B Prevailing Wind Direction Top View Direccon del viento predominante Vista superior Nail 25ln Clavo A I e' .Owens:Comfng SiseNg", Nails 4 �" Clavos 1 I I I I I I I EI e g EXIM, Wn de e ping V II I A 12" Figure 17:Isometric View,Berkshire and DuraRidge Figure 18:Plan View,Berkshire and DuraRidge 6.4.1.2 WeatherGuard®HP Hip&Ridge Shingles: Fig;.A q Ftg C:Hip&-Ridge Shingle Fasterong.` Preva�Ing 1NIad TopVkiY Direction ." Nails q`q I I A i i Nails Nails I[ i1i �osure . 5 Exposure. Figure 19:Isometric View,WeatherGuard HP Hip&Ridge Figure 20:Plan View,WeatherGuard HP Hip&Ridge NEMO ETC,LLC Evaluation Report 037940.02.12-R9 Certiflcateof Authorization#32455 6m EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-R14 Owens Corning Asphalt Roof Shingles Revision 9:06/13/2019 Page 9 of 30 i I ONEMOjetc. 6.4.1.3 ProEdge®Hip&Ridge Shingles: Prevailing Standard11° Wind Direction Fastening SealarnStrip Pattern. 6•Exposure j12Sealant Fasten 711 78°Expos t eCover Exposed 1 Fasteners with ':Roof Cement MIN Figure 21:Isometric View,ProEdge Figure 22: Plan View,ProEdge LABELING:7. 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1S07.2.7.1/R90S.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. QUALITY10. PRI Construction Materials Technologies,LLC—QUA9110; 813 621-5777;bwilson@pricmt.com END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 037940.02.12-R9 Certificate of Authorization#32455 6TM EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1114 Owens Corning Asphalt Roof Shingles Revision 9:06/23/2019 Page 10 of 10