Loading...
HomeMy WebLinkAboutProduct Approval REVIEWED FOR CODE. COMPLIANCE LU( DESIGN,LLC. j RECEIVED erhficate o Authorization JJ9503 ®HRISTIAN STREET, UNIT#13 �TRIi�6iTY ERQ SEP 2 7 20119 OXFORD,CT 06478 a _ _._. ..• �°'" (203)262-9245 i EVALUATION REPORT ' ST. Lucie County, Permitting TRI-BUILT Materials Group,LLC Evaluation Report A42960.10.12-116 PO Box 70 FL16048-R6 Rutherford, NJ 07070 Date of Issuance:10/25/2012 (800)516-1485 Revision 6:,09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for .use of the product under the Florida Building Code and Florida Building Cade, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. fDESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:.The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: pssttrrr�,, Robertl.M. Nieminen,P.E. r,=* t t The facsimile seal appearing was authorized by Robert Nieminen, 'Florida Registration No.59166,Florida DCA ANE198.3 P.E.on 09/25/2017.This does not serve as an electronically signed document. I CERTIFICATION OF INDEPENDENCE: 1. Trinity]ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does'not have.nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. ate, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting Or design guidance unless retained specifically for that purpose. i i I _ r I i �. ERD. _ TRINITY ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 6th Edition(2017)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.4/1507.1.1,1507.2.9.2 Physical Properties .ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012 3. REFERENCES: Enti Examination Reference Date ERD(TST6049) Physical Properties S40540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties S40540.11.13 11/19/2013 ERD(TST6049) Physical Properties -S4054o.b3.14 03/26/2014 ERD(TST6049) Physical Properties S44870.04.14-2 04/02/2014 ERD(TST6049) Physical Properties S44870.04.14-3 04/02/2014 ERD(TST6049) Physical Properties S44870.04.14-1 04/10/2014 ERD(TST6049) Physical Properties S44870.04.14-4 04/10/2014 ERD(TST6049) Physical Properties S43530.02.14-1-R1 05/14/2014 ERD(TST6049) Physical Properties S43530.05.14 05/28/2014 ERD(TST6049) Physical Properties S40540.10.14 10/31/2014 ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 ERD(TST6049) Wind Resistance SC14045.05.17-111 06/07/2017 UL,LLC.(QUA9625) Quality Control Multiple-Listing R16814 12/10/2015 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.b7/18/2020 4. PRODUCT DESCRIPTION: 4.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width; meets ASTM D1970. 4.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012. 4.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-116 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-116 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 2 of 6 f °TRINITY ERD 5.4 TRI-BUILT Roof Underlayments may be used with any- prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF CovER OPTIONS Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate Shingles &Shingles Tri-Built Sand-R SA Shingle Yes No No No Yes Yes Underlayment Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes Underlayment See 5.5.1 Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underlayment i 5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations. TABLE lA:ALLOWABLE TILE AOHESIVE f UNDERLAYMENT COMBINA7ION51 I Adhesive Florida,Product Approval Underlayments ICP Adhesives Polyset®AH-160 FL6332 Tri-Built S/A HT TU Underlayment Dow TileBond'" FL22525 Tri-Built S/A HT TU Underlayment 5.'6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT Materials Group,LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT Materials Group, LLC requires tongue-and.-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Dens Deck Prime;.SECU ROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems (Tri-Built.S/A. HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVH2 EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 3 of 6 t. l ERL QTRINITY 5.6.3 Bond to Mechanically Attached Base Laver: - Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226,Type I or Il.felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04- 12). 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure=-45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional),ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. #2 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Soprema Elastocol 600c Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. #3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self-adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end-laps. #4 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2)spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three, equally spaced rows in the center of the sheet. Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. Exterior Research and Design,LLC. Evaluation Report A42960.10.12-116 Certificate of Authorization#9503 6 H EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 4 of 6 „ i _ TRINITY ERD 5.6.4.1 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements: 5.7 Exposure Limitations: Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE.$UPPAGE UMi7AnONS FOR DIRECT-DEGIC TILE INSTALIATlONB Underlayment Tile Profile Staging Method Maximum Slope Flat Max.10-tile stack 6:12 j Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted,followed by 8 tiles high 6:12 on slope,as shown below) i j Tri-Built S/A HT TLI Underlayment Lugged I i I I I i i Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6T”EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 5 of 6 TRINITY ERD 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile applications: While priming is optional,TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the,release film diagonally while holding the membrane tight. Firmly roll, broom or hand-press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below,sealed in accordance with TRI-BUILT Materials Group,LLC requirements. When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Tri-Built S/A HT TU Underlayment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Gulfport, MS 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625;(314)578-3406; k.chancellor@us.ul.com -END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-116 Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 6 of 6 �. - REVIEWED FOR CODE COMPLIANCE NEMO etc. ST a C®U�pTrrtificate of Authorization#32455 �+ Chrjstian Street, Unit#13 B®CC Oxford,CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY • • Polyglass USA,Inc. SEP 2 7 20i9 Evaluation Report P9290.02.08-R21 150 Lyon Drive - FL1654-R23 Fernley, NV 89408 Date of Issuance:02/11/2008 ST. Lucie County, Permitting(954)233-1330 Revision 21.10/08/2018 -. I SCOPE: ' This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use.of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6eh Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: Polyglass SOS and APP Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.of any changes to the product(s),the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 65-page Appendix. Prepared by: -05`, Robert J.M.Nieminen,P.E. n,'`�s. eq°+, The facsimile seal appearing was authorized by Robert Florida Registration N0.59166,Florida DCA ANE1983 ?%�S:�; � �' Nieminen,P.E.on 10/08/2018.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. s . ONEMOletc. ROOFING SYSTEMS EVALUATION: SCOPE:1. Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems,as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the a Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section v - Property Standard _Year 1504.3.1 Wind FM 4474 2011 i 1504.3.1 Wind UL 1897 2012 1504.7 Impact FM 4470 2012 1507.11.2 Physicals ASTM D6162 2008 1507.11.2 Physicals ASTM D6163 2008 1507.11.2 Physicals ASTM D6164 2011 1507.11.2 Physicals ASTM D6222 2011 1507.11.2 Physicals ASTM D6509 2009 3. REFERENCES: Entity Exam° Reference, Date. _ .Entl _.,_Exam=. Reference Date ERD(TST6049) Physicals P10490.10,08-2 10/30/2008 FM(TST1867) FM 4470 2DOAO.AM 12/23/1998 ERD(TST6049) FM 4470/4474 P13760.09.09 09/10/2009 FM(TST1867) FM 4470 2DSA9.AM 06/22/1999 ERD(TST6049) FM 4470/4474 P13770.09.09 09/10/2009 FM(TST1867) FM 4470 3006646 01/04/2000 ERD(TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 FM(TST1867) FM 4470 3001334 01/25/2000 ERD(TST6049) FM 4470/4474 P30550.12.09 1Z/02/2009 FM(TST1867) FM 4470 3001334 02/15/2000 ERD(TST6049) Physicals P33960.12.10 12/30/2010 FM(TST1867) FM 4470 3000857 01/12/2000 ERD(TST6049) FM 4470/4474 P33970.03.11 03/15/2011 FM(TST1867) FM 4470 3004091 01/12/2000 ERD(TST6049) Physicals P37590.03.13-3A 03/06/2013 FM(TST1867) FM 4470 3006115 05/02/2001 ERD(TST6049) FM 4470/4474 P39680.03.13 03/04/2013 FM(TST1867) FM 4470 301.2321 07/29/2002 ERD(TST6049) Physicals P37590.03.13-1-R1 06/26/2013 FM(TST1867) FM 4470 3014692 08/05/2003 ERD(TST6049) Physicals P37590.03.13-2-R1 07/01/2013 FM(TST1867) FM 4470 3014751 08/27/2003 ERD(TST6049) Physicals P37590.07.13-2 07/01/2013 FM(TST1867) FM 4470 3007170 01/13/2004 ERD(TST6049) Physicals P37590.03.13-5-R1 07/01/2013 FM(TST1867) FM 4470 3019317 06/30/2004 ERD(TST6049) Physicals P37590.07.13-1 07/02/2013 FM(TST1867) FM 4470 3020703 07/30/20D4 ERD(TST6049) FM 4470/4474 P41630.08.13 08/06/2013 FM(TST1867) FM 4470/4474 3018332 01/31/2006 ERD(TST6049) Physicals P45940.09.13 09/04/2013 FM(TST1867) FM 4470/4474 3023368 03/20/2006 ERD(TST6049) Physicals P44370.10.13 10/04/2013 FM(TST1867) FM 4470/4474 3024594 05/23/2006 ERD(TST6049) Physicals P39520.09.14-2 09/11/2014 FM(TST1867) FM 4470/4474 3023458 07/18/2006 ERD(TST6049) FM 4470/4474 SC6160.11.14 11/10/2014 FM(TST1867) FM 4470/4474 3030668 09/12/2007 ERD(TST6049) Physicals P45440SC.03.15-1 03/31/2015 FM(TST1867) FM 4470/4474 3032172 06/12/2009 ERD(TST6049) Physicals SC5170.05.15 05/08/2015 FM(TST1867) FM 4470/4474 3049631 04/21/2014 ERD(TST6049) FM 4474 SC8085.05.15 05/19/2015 FM(TST1867) FM 4470/4474 3GS7029 02/02/2017 ERD(TST6049) Physicals SC5170.12.15 12/29/2015 NEMO(TST6049) Criticality 45-PLYG-18.001.06.18 06/23/2018 ERD(TST6049) FM 4470/4474 SC9455.15 04/Ol/2016 NEMO(TST6049) FM 4474 4L-PLYG-18-W3.08.18 08/21/2018 ERD(TST6049) FM 4470/4474 PLYG-SC8905.05.16-1 05/17/2016 NEMO(TST6049) FM 4474 PLYG.d.C4.CS,CS 09/21/2018 ERD(TST6049) FM 4470/4474 PLYG-SC8905.05.16-2 05/17/2016 NEW(TST6049) Criticality 45-PLYG-18-001.10.18 10/03/2018 ERD(TST6049) FM 4470/4474 PLYG-SC10915.07.16-it1 09/23/2016 PRI(TS75878) Physicals PUSA-062-02-01 12/04/2007 ERD(TST6049) UL 1897 PLYG-SC12025.10.16 10/12/2016 PRI(TST5878) Physicals PUSA-061-02-02 01/28/2008 ERD(TST6049) FM 4470/4474 PLYG-SC11475.16 11/17/2016 PRI(TST5878) Physicals PUSA-064-02-02 02/27/2008 ERD(TST6049) FM 4470/4474 PLYG-SC13235.01.17 01/17/2017 PRI(TST5878) Physicals PUSA-062-02-02 12/04/2008 ERD(TST6049) FM 4470/4474 PLYG-SC13920.05.17 05/30/2017 PRI(TST5878) TAS 114 PUSA-188-02-01 02/08/2017 ERD(TST11294) FM 4470/4474 PLYG-CTL13945.05.17-1 05/30/2017 PRI(TST5878) TAS 114 PUSA-188-02-02 02/08/2017 ER6(TST11294) FM 4470/4474 PLY6-M13945.05.11-3 05/30/2017 PRI(TST5878) TAS 114 PUSA-188-02-03 02/08/2017 ERD(TST6D49) FM 4470/4474 PLYG-SC13945.05.17 05/30/2017 PRI(TST5878) TAS 114 PUSA-202-02-01 05/17/2017 I ERD(TST6049) FM 4470/4474 PLYG-SC15760.09.17 09/1112017 PRI(TST5878) TAS 114 PUSA-202-02-02 05/17/2017 FM(TST1867) FM 4470 2WW AM 08/D4/1994 M-D(CER1592) HVHZ Various NOAs Various FM(TST1867) FM 4470 OD3A3.AM 04/04/1997 M-D(CER1592) Prop.for Rev. 10-0823 10/12/2010 UL(QUA9625) Quality Control Service Confirm 09/13/2018 NEMO ETC,LLC Evaluation Report P9290.02.08-R21 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL1654-1123 Polyglass Modified Bitumen Roof Systems,1954)233-1330 Revision 21:10/08/2018 Page 2 of 4 i ONEMOJetc. 4. PRODUCT DESCRIPTION: This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. TABLE 1:ROLL-GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS ? Type Product . ` specMcation Reference Grade 7,ype Polyglass G2 Base ASTM D4601 N/A II Base Sheets Polyflex SA Base ASTM D4601 N/A II Polyglass APP Base ASTM D6509 N/A N/A Polyglass HT Base 650 ASTM D6162 S III Elastobase ASTM D6163 S 1 Elastoflex V ASTM D6163 S I Elastoflex SA V Base ASTM D6163,Table 2 S I Elastoflex SA V FR Base ASTM D6163,Table 2 S I SBS Membranes Elastoflex SA V Plus ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastobase Poly ASTM D6154 S I Elastoflex 56 ASTM D6164 S I Elastoflex S6 Type If ASTM D6164 S II Elastoflex VG ASTM D6163 G I Elastoflex VG FR ASTM D6163 G I Elastoflex 56 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G I Polyfresko G SBS(sand or poly-fi(m back) ASTM D6164 G I Polyfresko G SBS FR(sand or poly-film back) ASTM D6164 G 1 SBS Membranes Elastoshield TS G ASTM D6164 G I Elastoshield TS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Polyreflect ASTM D6164 S I Polyflex ASTM D6222 S 1 Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G I Polyfresko G ASTM D6222 G I Polyfresko G FR ASTM D6222 G I APP Membranes Polybond ASTM D6222 S I Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G I Polyflex SA P FR ASTM D6222 G I Polyfresko G SA ASTM D6222 G I Polykool ASTM D6222 S I 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations,foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. NEMO ETC,LLC Evaluation Report P9290.02.08-R21 Certificate of AuthorizationN32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL3654-R23 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Revision 21:10/08/2028 Page 3 of 4 s ONEMOletc. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations,the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question,field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1),1609.3(2)or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 611320-3. INSTALLATION:6. 6.1 Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions,subject to the Limitations/Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP"= Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. REQUIREMENTS:7. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. PLANTS:8. MANUFACTURING Contact the noted CIA agency for information on product locations covered for F.A.C.Rule 611320-3 QA requirements 9. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(314)578-3406,k.chancellor@us.ul.com -THE 65-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT- NEIVIO ETC,LLC Evaluation Report P9290.02.08-R21 Certificate of Authorization#32455 eEDITION(2017)FBC NON-HVHZ EVALUATION F1.1654-1123 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Revision 21:10/08/2018 Page 4 of 4 ONEMOletc. TABLE 1G: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: • BONDED ROOF COVER SYNtu m Deck(Note i) Type -,Base Roof 5)_ N1DP se Sheet ' .Cover_(Notel Fasten Attach Base Ply Cap Ply Osf) No BME P Min.15/32- 9-inch o.c.at min.2-inch lap and 18-inch o.c.at None SBS-AA,SBS-TA,APP- -45.0' W-81 inch plywood Elastobase,Elastobase P Simplex MAXX Cap two(2),equally spaced,staggered center rows TA Min.15/32- 32 ga.,1-5/8-inch diameter tin caps with 12 ga.annular 6-inch o.c.at min.3-Inch lap and 6-inch o.c.at None SBS-AA,SBS-TA,APP- 45.0 W-82 inch APA Elastobase,Elastobase P' ring shank nails four(4),equally spaced,staggered center rows TA rated OSB Min.15/32- Elastobase,Elastobase P(poly-film 32 ga.,1-5/8-inch diameter tin caps with 12 ga.annular 6-inch o.c.at min.3-inch lap and 6-inch o.c,at W-83 Inch APA top) ring shank nails four(4),equally spaced,staggered center rows None SBS-SA,APP-SA 45.0 rated OSB Min.15/32- 32 ga.,1-5/8-inch diameter tin caps with 12 ga.annular 6-inch o.c.at min.3-inch lap and 6-inch o.c.at W-84 inch APA Polyglass APP Base ring shank nails four(4),equally spaced,staggered center rows None APP-TA -45.0 rated OSB Min.15/32- 9-inch o.c.at min.2-Inch lap and 12-inch o.c.at None SBS-AA,SBS-TA,APP- -52.5 W-85 inch plywood Elastobase,Elastobase P Simplex MAXX Cap two(2),equally spaced,staggered center rows TA W-86 Min.15/32- Elastobase,Elastobase P Original Simplex Cap Nails(1-inch metal head diameter, 6-Inch o.c.at min.3-Inch lap and 6-inch o.c.at SBS-AA,SBS-TA,APP- 52.5 inch plywood 11 gauge x min.1.25-inch long annular grooved shank) four(4),equally spaced,staggered center rows None TA W 87 Min.15/32- Elastobase,Elastobase P(poly-film Original Simplex Cap Nails(1-inch metal head diameter, 6-inch o.c,at min.3-Inch lap and 6-Inch o.c.at None SBS-SA,APP-SA -52.5 inch plywood top) 11 gouge x min.2.25-Inch long annular grooved shank) four(4),equally spaced,staggered center rows W 88 Min.15/32- Polyglass APP Base Original Simplex Cap Nails(1-inch metal head diameter, 6-inch o.c.at min.3-inch lap and 6-inch o.c.at None APP-TA -52.5 Inch plywood 11 gauge x min.1.25-Inch long annular grooved shank) four(4),equally spaced,staggered center rows Elastobase,Elastobase P,Polyglass G2 Base,CertainTeed Glasbase, 8-Inch o.c,at min.flinch lap and 8-inch o.c,at Min.19/32- 32 ga.,1-5/8-Inch diameter tin caps with 11 ga.annular SBS-AA,585-TA,APP- W-89 Inch plywood Firestone MB Base,JM Perma-Ply ring shank nails three(3),equally spaced,staggered center None TA 60.0 28,Tamko Glass Base or GAFGLAS rows #75 Min.19/32- Elastobase,Elastobase P(poly-film 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular S-Inch o.c,at min.4-inch lap and 8-Inch o.c.at W-90 three(3),equally spaced,staggered center None SBS-SA,APP-SA -60.0 Inch plywood top} ring shank nails rows W-91 Min.15/32-: Polyglass G2 Base,Elastobase, 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 8-inch o.c.at min.4-inch lap and 8-inch o.c.at SBS-AA,SBS-TA,APP- 67.5 inch plywood Elastobase P ring shank nails four(4),equally spaced,staggered center rows None TA W 92 Min.15/32- Polyglass APP Base 32 ga.,1-5/8-inch diameter tin caps with it ga.annular 8-Inch o.c,at min.4-Inch lap and 8-inch o.c.at None APP-TA -67.5 Inch plywood ring shank nails four(4),equally spaced,staggered center rows 10-Inch o.c.at min.4-inch lap and 10-inch o.c. SBS-AA,SBS-TA,APP- W-93 Min.15/32- Polyglass G2 Base,Elastobase, Simplex MAXX Cap at three(3),equally spaced,staggered center None TA -75.0 inch plywood Elastobase P rows 104nch o.c.at min.4-inch lap and 10-inch o.c. W 94 Inch plywood. Polyglass APP Base Simplex MAXX Cap at three(3),equally spaced,staggered center None APP-TA -75.0 Inch plywood.. rows MEMO ETC,LLC Evaluation Report P9290.02.08-R21 for FL1654-R23 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 21:10/08/2018 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 18 of 65 ONEMOjetc. CONSTRUCTIONTABLE IG: WOOD DECKS—NEW •.. SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAILS),BONDED ROOF COVER System Deck(Note;l). " 'BateRoo 5) MDP Sheet "- "' f Cover(Note 1 No T e Fasten x- Attach Base Ply. Cap fly 1psf) W-95 Min.15/32- Polyglass G2 Base,Elastobase, Simplex MAXX Cap 9-Inch o.c.at min.4-inch lap and 9-inch o.c.at None SBS-AA,SBS-TA,APP- 90.0 inch plywood Elastobase P four(4),equally spaced,staggered center rows TA Min.15/32- 9-inch o.c.at min.4-inch lap and 9-inch o.c,at None APP-TA -90.0 W 96 Inch plywood Polyglass APP Base Simplex MAXX Cap four(4),equally spaced,staggered center rows Min.15/32- 6-inch o.c.at min.2-inch lap and 6-inch o.c.at SBS-AA,SBS-TA,APP- W 97 inch plywood Elastobase,Elastobase P Simplex MAXX Cap two(2),equally spaced,staggered center rows None TA 90.0 W 98 Min.19/32- Elastobase,Elastobase P(poly-film 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 4-inch o.c.at min.4-Inch lap and 4-inch o.c.at None SBS-SA,APP-SA -97.5 Inch plywood top) ring shank nails. four(4),equally spaced,staggered center rows Min.15/32- 6-inch o.c.at min.2-Inch lap and 6-inch o.c.at SBS-AA,SBS-TA,APP- W-99 inch plywood Elastobase,Elastobase P Simplex MAXX Cap three(3),equally spaced,staggered center None TA 105.0 rows Min.19/32- 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 6-inch o.c.at min.4-inch lap and 6-inch o.c.at None SBS-AA,SBS-TA,APP- _112.5 W-100 inch plywood Elastobase,Elastobase P ring shank nails four(4),equally spaced,staggered center rows TA Min32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 6-inch o.c,at min.4-inch la and 6-inch o.c.at W-101 Inch plywood Elastobase,Elastobase P(poly-film ring shank nails. Note:Tin caps are to be primed with P None SBS-SA,APP-SA -112.5 Inch plywood top) P6100 orASTM D41 primer. four(4),equally spaced,staggered center rows .ASPH" PLIE[IORTORCHAPPLIED BASE PLY:::'. - .. Min.15/32- 9-inch o.c.at min.2-inch lap and 18-inch o.c.at BP-AA,SBS-AA,SBS- SBS-SA,APP-5A,SBS- -45.0" W-102 inch plywood Elastobase,Elastobase P Simplex MAXX Cap two(2),equally spaced,staggered center rows TA,APP-TA AA,SBS-TA,APP-TA Min.15/32- 32 ga.,1-5/8-inch diameter tin caps with 12 ga.annular 6-inch o.c.at min.3-inch lap and 6-inch o.c.at BP-AA,SBS-AA,SBS- SBS-SA,APP-SA,SBS- W-103 Inch APA Elastobase,Elastobase P ring shank nails four(4),equally spaced,staggered center rows TA,APP-TA AA,SBS-TA,APP-TA -45.0 rated OSB Min.15/32- 32 ga.,1-5/8-inch diameter tin caps with 12 ga.annular 6-inch o.c.at min.3-inch lap and 6-inch o.c.at W-104 inch APA Polyglass APP Base ring shank nails four(4),equally spaced,staggered center rows APP-TA APP-TA -45.0 rated OSB Min.15/32- 9-inch o.c.at min.2-Inch lap and 12-Inch o.c,at BP-AA,SBS-AA,SBS- SBS-SA,APP-SA,SBS- -52.5 W-105 inch plywood Elastobase,Elastobase P Simplex MAXX Cap two(2),equally spaced,staggered center rows TA,APP-TA AA,SBS-TA,APP-TA W-106 Min.15/32- Elastobase,Elastobase P Original Simplex Cap Nails(1-inch metal head diameter, 6-inch o.c.at min.3-inch lap and 6-inch o.c,at BP-AA,SBS-AA,SBS- SBS-SA,APP-SA,SBS- -52.5 inch plywood 11 gauge x min.1.25-inch long annular grooved shank) four(4),equally spaced,staggered center rows TA,APP-TA AA,SBS-TA,APP-TA W-107 Min.15/32- Polyglass APP Base Original Simplex Cap Nails(1-inch metal head diameter, 6-inch o.c.at min.3-inch lap and 6-inch o.c,at APP-TA APP-TA -52.5 inch plywood 21 gauge x min.1.25-inch long annular grooved shank) four(4),equally spaced,staggered center rows Elastobase,Elastobase P,Polyglass G2 Base,CertainTeed Glasbase, 8-inch o.c.at min.4-inch lap and 8-inch o.c.at Min.i9/32- 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular BP-AA,SBS-AA,SBS- SBS-SA,APP-SA,SB5- W-108 Firestone MB Base,JM Perma-Ply ring shank nails three(3),equally spaced,staggered center TA,APP-TA AA,SBS-TA,APP-TA -60.0 Inch plywood 28,Tamko Glass Base or GAFGLAS rows #75 W-309 Min.15/32- Polyglass G2 Base,Elastobase, 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 8-inch o.c.at min.4-inch lap and 8-inch o.c.at BP-AA,SBS-AA,SBS- - -SBS-SA,APP-SA,SB5- -67.5 Inch plywood Elastobase P ring shank nails four(4),equally spaced,staggered center rows TA,APP TA AA,SBS-TA,APP-TA NEMO ETC,LLC Evaluation Report P9290.02.08-R21 for FL1654-1123 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 21:10/08/2018 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems,(9S4)233-1330 Appendix 1,Page 19 of 65 NNEMIDjetc, TABLEIG: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: • BONDED ROOF COVER System Base Sheet, Roof Cover(Note 15)• MDP No. Deck(Note 1) Type Fasten Attach Base Ply Cap Ply (Psf) W-110 Min.15/32- Polyglass APP Base 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 8-inch o.c.at min.4-inch lap and 8-inch o.c.at APP-TA APP-TA -67.5 Inch plywood ring shank nails four(4),equally spaced,staggered center rows Min.15/32- Polyglass G2 Base,Elastobase, 10-inch o.c.at min.4-inch lap and 10-inch o.c. BP-AA,SBS-AA,SBS- SBS-SA,APP-SA,SBS- W-111 inch plywood Elastobase P Simplex MAXX Cap at three(3),equally spaced,staggered center TA,APP-TA AA,SBS-TA,APP-TA -75.0 rows _ Min.15/32- 10-inch o.c.at min.4-inch lap and 10-Inch o.c. W-112 Inch plywood Polyglass APP Base Simplex MAXX Cap at three(3),equally spaced,staggered center APP-TA APP-TA -75.0 rows W-113 Min.15/32- Polyglass G2 Base,Elastobase, Simplex MAXX Cap 9-inch o.c.at min.4-inch lap and 9-Inch o.c.at BP-AA,SBS-AA,SBS- SBS-SA,APP-SA,SBS- -90.0 inch plywood Elastobase P four(4),equally spaced,staggered center rows TA,APP-TA AA,SBS-TA,APP-TA W-114 Min.15/32- Polyglass APP Base Simplex MAXX Cap 9-inch o.c.at min.flinch lap and 9-inch o.c.at APP-TA APP-TA -90.0 inch plywood four(4),equally spaced,staggered center rows W-115 Min.15/32- Elastobase,Elastobase P Simplex MAXX Cap 6-inch o.c.at min.2-inch lap and 6-inch o.c,at BP-AA,SBS-AA,SBS- SBS-SA,APP-SA,SBS- -90.0 inch plywood two(2),equally spaced,staggered center rows TA,APP-TA AA,SBS-TA,APP-TA Min.15/32- 6-inch o.c.at min.2-Inch lap and 6-inch o.c.at BP-AA,SBS-AA,SBS- SBS-SA,APP-SA,SBS- W-116 inch plywood Elastobase,Elastobase P Simplex MAXX Cap three(3),equally spaced,staggered center TA,APP-TA AA,SBS-TA,APP-TA 105.0 rows Min.19/32- 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 6-inch o.c.at min.4-inch lap and 6-inch o.c.at BP-AA,SBS-AA,SBS- SBS-SA,APP-SA,SBS- Elastobase,inch plywood Elastobase,Elastobase P ring shank nails four(3),equally spaced,staggered center rows TA,APP-TA AA,SBS-TA,APP-TA 112.5 SELF-ADHERING.BASEPLY7. Min.15/32- Elastobase,Elastobase P(poly-film 32 ga.,1-5/8-inch diameter tin caps with 12 ga.annular 6-inch o.c.at min.3-Inch lap and 6-inch o.c.at SBS-SA,APP-SA,SBS- W-118 Inch APA top) ring shank nails four(4),equally spaced,staggered center rows SBS-SA TA,APP-TA -45.0 rated OSB W-119 Min.15/32- Elastobase,Elastobase P(poly-film Original Simplex Cap Nails(1-inch metal head diameter, 6-inch o.c.at min.3-inch lap and 6-inch o.c.at SBS-SA SBS-SA,APP-SA,SBS- -52.5 inch plywood top) 11 gouge x min.1.25-Inch long annular grooved shank) four(4),equally spaced,staggered center rows TA,APP-TA W-120 Min.15/32- Polyglass APP Base,Elastobase, Original Simplex Cap Nails(1-inch metal head diameter, 6-Inch o.c.at min.3-inch lap and 6-inch o.c.at Polyflex SA Base APP-TA -52.5 inch plywood Elastobase P(poly-film top) 11 gauge x min.1.25-inch long annular grooved shank) four(4),equally spaced,staggered center rows Min.19/32- Elastobase,Elastobase P(poly-film 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 8-Inch o.c.at min.4-inch lap and 8-inch o.c.at SBS-SA,APP-SA,SBS- W-121 inch plywood top) ring shank nails three(3),equally spaced,staggered center SBS-SA TA APP-TA -60.0 rows Min.19/32- Elastobase,Elastobase P(poly-film 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 8-inch o,c,at min.flinch lap and 8-Inch o.c.at W-122 inch plywood top) ring shank nails three(3),equally spaced,staggered center Polyflex SA Base APP-TA -60.0 rows W-123 Min.19/32- Elastobase,Elastobase P(poly-film 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 4-inch o.c.at min.4-inch lap and 4-inch o.c.at SBS-SA SBS-SA,APP-SA,SBS- 97 5 inch plywood top) ring shank nails. four(4),equally spaced,staggered center rows TA,APP-TA Min.19/32- Elastobase,Elastobase P(poly-film 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 4-inch o.c,at min.4-inch lap and 4-inch o.c.at W-124 -inch plywood top) ring shank nails. four(4),equally spaced,staggered center rows Polyflex SA Base APP-TA 97.5 MEMO ETC,LLC Evaluation Report P9290.02.08-R21 for FL1654-R23 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 21:10/08/2018 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 20 of 65 .ism 1 .. � � i . 4� :� '. * .. � _ 't Rr_ .. ' � .. a k :. .. f4 � ` .. � a •. i .. _. • .. I � � �• ' � � � ! � ONEMOletc. TABLEIG: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAILS),BONDED ROOF COVER System, Base Sheet ;, 'Roof Cover(Note 15) MDP Deck(Note 1) No. Type Fasten "Attach Base Ply Cap Ply (psf) 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular Elastoflex SA V Plus, W-125 Min.19/32- Elastobase,Elastobase P(poly-film ring shank nails. Nate:Tin caps are to be primed with 6-inch o.c.at min.4-inch lap and 6-inch o.c.at Elastoflex SA V Plus SBS-SA,APP-SA,SBS- _312.5 Inch plywood top) PGI00 orASTM D41 primer. four(4),equally spaced,staggered center rows FR TA,APP TA Min.19/32- Elastobase,Elastobase P(poly-film 32 ga.,1-5/8-Inch diameter tin caps with 11 ga.annular 6-inch o.c.at min.flinch lap and 6-inch o.c.at W-126 inch plywood top) ring shank nails. Note:Tin caps are to be primed with four(4),equally spaced,staggered center rows Polyflex SA Base APP-TA -112.5 PG100 or ASTM D41 primer. TABLE 1H: WOOD-DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREWS PLATES),BONDED ROOF COVER System " Base Sheet Roof-Cover(Note 15) , MDP Deck(Note ) No;, Type• Fasten Attach Base Ply" Cap (Psf) No BAS'EPLY7 Elastobase,Elastobase P, Polyglass G2 Base, OMG Flat Bottom Plates(square)with Roofgrip#14, None Min.19/32-Inch CertainTeed Glasbase, 12-inch o.c,at min.4-inch lap and 12-inch o.c.at SBS-AA,SBS-TA,APP- W-127 Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast#14 or -52.5 plywood Firestone MB Base,1M Trufast 3"Metal Insulation Plate with Trufast HD two(2),equally spaced,staggered center rows TA Perma-Ply 28,Tamko Glass Base or GAFGLAS#75 W 128 Min.19/32-Inch Elastobase,Elastobase P OMG Flat Bottom Plates(square)with Roofgrip#12 12-inch o.c.at min.4-inch lap and 12-inch o.c.at None SBS-AA,SBS-TA,APP- _60.0 plywood two(2),equally spaced,staggered center rows TA Min.19/32-inch Trufast Versa Fasteners(min.%"penetration)&Plates; 12-inch o.c.at min.4-inch lap and 12-inch o.c.at SBS-AA,SBS-TA,APP_ APA rated OSB Elastobase,Elastobase P 2 screws per plate installed 180'into the holes of the two(2),equally spaced,staggered center rows None TA -67.5 VV_129 or plywood plate,parallel to the width-direction of the sheet* Note: *For re-roof or recover construction,field withdrawal resistance testing(Note 11)shall yield minimum 199lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate maybe utilized to produce minimum withdrawal resistance Min.19/32-inch Elastobase,Elastobase P Trufast Versa Fasteners(min.%"penetration)&Plates; 12-inch o.c.at min.4-Inch lap and 12-Inch o.c.at APA rated OSB (poly-film top) 2 screws per plate installed 180°Into the holes of the two(2),equally spaced,staggered center rows None SBS-SA,APP-SA -67.5 W-130 or plywood plate,parallel to the width-direction of the sheet* Note: *For re-roof or recover construction,field withdrawal resistance testing(Note 11)shall yield minimum 199 Ibf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance Min.19/32-inch Trufast Versa Fasteners(min.''/a"penetration)&Plates; 12-inch o.c,at min.4-inch lap and 12-Inch o.c,at APA rated OSB Polyglass APP Base 2 screws per plate installed 180°into the holes of the two(2),equally spaced,staggered center rows None APP-TA -67.5 W-131 or plywood plate,parallel to the width-direction of the sheet* Note: *For re-roof or recover construction,field withdrawal resistance testing(Note 11)shall yield minimum 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance NEMO ETC,LLC Evaluation Report P9290.02.08-R21 for FL1654-1123 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 21:10/08/2018 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 21 of 65 . . Y � -� � R" b :t: .. ON EMO etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER System Substrate Base Insulation Layer Top Insulation Layer RoofCover`(Note No:, . (Notes 1&12) Type Attach Type, Attach Base Ply Ply _ Cap Ply (Psf) (Optional)Min.1-inch Polytherm, R-42 Existing asphaltic roof ACFoam II,Polytherm G,ACFoam III, OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 SBS-CA1, None SBS-CA1,SBS- -127.5 ENRGY 3,Polytherm H,H-Shield or Multi- Board SBS-CA2 CA2,APP-CA1 Max FA3 (Optional)Min.1-Inch Polytherm, ACFoam II,Polytherm G,ACFoam ill, Min.0.25-inch Dens Deck Prime or SECUROCK CR 20 SBS-CA1, (Optional)SBS-CA1, SBS-CA3,SBS- R 43 Existing asphaltic roof ENRGY 3,Polytherm H,H-Shield or Multi- CR-20 Gypsum-Fiber Roof Board SBS-CA2 SBS-CA2 CA2,APP-CAl 120.0 Max FA3 (Optional)Min.1-inch Polytherm, ACFoam II,Polytherm G,ACFoam III, Min.0.25-inch Dens Deck Prime or DEXcell FA SBS-CA3,SBS- R 44 Existing asphaltic roof ENRGY 3,Polytherm H,H-Shield or Multi- CR-20 Glass Mat Roof Board CR-20 SBS CAI None CA2 APP CA1 127.5 Max FA3 (Optional)Min.1-inch Polytherm, ACFoam 11,Polytherm G,ACFoam III, Min.0.25-inch SECUROCK Gypsum-Fiber Roof SBS-CA1, SBS-CA1,SBS R-45 Existing asphaltic roof ENRGY 3,Polytherm H,H-Shield or Multi- CR-20 Board CR-20 SBS-CA2 None CA2,APP-CA3 -127.5 Max FA3 (Optional)Min.1-Inch ENRGY 3, Min.0.25-inch Dens Deck Prime or SECUROCK CR-20 SBS-CA3, None SBS-CA1,SBS- -232.5 R 46 Existing asphaltic roof Polytherm H,H-Shield,Multi-Max FA3 CR-20 Gypsum-Fiber Roof Board SBS CA2 CA2 TABLE • APPLICATIONS SYSTEM TYPE F:NON-INSULATED,BONDED BASE SHEET,BONDED ROOF COVER Substrate Roof Cover(Note 15) ,System No.. Primer MDP(psf) (Notes 1&12) Base Ply Ply Cap Ply'. Existing asphaltic (Optional if using asphalt applied Base)BP-AA,SBS- _ R-47 roof PG300 BP-AA(Optional if using asphalt applied Ply) AAA SBS-TA or APP-TA SBS-AA,SBS-TA,APP-TA 45.0 NEMO ETC,LLC Evaluation Report P9290.02.08-R21 for FL1654-R23 Certificate of Authorization#32455 CH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 21:10/08/2018 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 65 of 65 - , -� . ��µ _- _ . 1 � - -- , , _ Fi .� _ t S �,��� +�}_ �k . � k i�; _. ':p y - s Y i � .:�5 i I � 1 ' � �. p .. ' L