Loading...
HomeMy WebLinkAboutenginnering Architectonic Inc St. Lucie County iPlanning& Development Services Building and Code Regulation Division September 6,2019 i RE: 4120 Selvitz Road r To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and her certify that the proposed garage door is in compliance with the 2017 Florida Building Code, 160 mph wind zone, exposure "C",risk category II. From Table 1609.3.1: Vul, 160mph V,,d= 124mph From Table 1609.7(1): 16'h x 20'w door, 160mph=+23.3/-26.0 From Table 1609.7(2): 30' mean roof height, Exposure C=1.40 Required Design Pressures: 23.3 x 1.40=32.62 -26 x 1.40=-36.4 Product:Janus International Corporation,Series 3100 26 ga. Door Assembly Product Pressures: +35.0&-38.0 Res i OF y: H EA( ,. CIA .; ite tonic, Inc. .•'.�e 'STERED P�,G 806 Delaware Avenue Tel: 772.460 7751 www,architectonicinc.com Fort Pierce,Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1