HomeMy WebLinkAboutProduct Approvals, shingles 6/25/2019 Florida Building Cod'e Oriline
;:
;IWw.
ae t 0 . •
f Je
:•
BCIS Home Log In I User Registration Hot Topics ` Submit Surcharge Stats&'Facts f Publications Contact Us BCIS Site Map ; Links Searchd-
F dda
Product.Approval
USER:Public User
4�Y,N�A l'SS
Product ApprovalMenu>Product or Agpsation Search>gpolication Llst>Application Detail
•
FL.# FL10674-R13
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning r
Address/Phone/Email One Owens Corning Parkway
Toledo,'OH 43659
(740)404-7829 a
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscoming.corn. j
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
x, mel.sancrant@owenscornig.com
P�s r
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
r, I Evaluation'Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nie.minen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich, PE
R.ii Validation Checklist—Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTMD7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT°/g2b6w7ahReglCQ8ucR6ixEBFhs7tvJgZew%3d%3d 1/2
I
6/25/2019 Florida Building Code,Online
Product Approval Method Method 1 Option D
I
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
DateAevised 06/13/2019
u off; rc►du' ;��. <f
Nlolei Nperi ber or Mame, ':J`�, s.Descr>pt�on, < r z
10674.1 Owens Corning-Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles
Shingles and Starters
^� Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10674.1113 II 2017 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pdf
Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to.ER,Section 5. Evaluation Reports
a -€ FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES F1_10674-R13.p�df
Created by Independent Third Party:Yes
Contact Us,.:2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The Stale of'Plorida is an AA/EEO employer.Copyr1ght 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under-Florida law,email addresses are public records.If you do not want your email,address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phoneorby traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455:275(1),
-> Florida Statutes,effective October 1,_2012,licensees licensed under Chapter 455;F.S.must provide the:Department with an email address if they have one.,The(emails
-` provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
i
j
i
I
i
tittps://www.floridabuilding.org/pr/pr_app�dtl:aspx?param=wGEVXQwtDgtBNbF-Y5V%2boQT%2b6w7ahReglCQBucR6ixEBFhs7tVJgZew%3d%3d 2/2
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
F)o TRINITY 3
ERD
353 CHRISTIAN STREET,UNIT#1
ERC3 OXFORD,CT 0647;8
(203)262-9245
EVALUATION REPORT
Ow.ens-Corning. Evaluation Report 037940.02.12-RS
One Owens Corning Parkway FL10674-R1;3
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)A04-7829 Revision 8: 10/09/201'7
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated "for compliance with the 61h Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling.shall be in accordance, with the requirements the Accredited Quality Assurance Agency noted
herein.and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE:: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the: Code that late to the product change.
Acceptance of this Evaluation Rp
.e ort b the named client constitutes agreement to notify Robert Nieminen,,P.E. if the
product changes or the referenced Quality Assurance documentation'changes.: Trinity IERD requires a complete
review of this Evaluation Report relative to updated Code requirementswith each Code Cycle.
ADVERTISEMENT: The Evaluation:Report number preceded by the words `TrinityI ERD Evaluated" maybe,displayed in
advertising literature. If any portion of the Evaluation Report is displayed;then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be;provided to the user by the manufacturer or
its distributors and Shall be.avalable for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared b ,)l�irre•n,,,,
9
RobertJ.M.Nieminen P.E. ''�;�Su 4 9 The facsimile seal appearing was authorized by Robert
Florida Registration No.59165 Floridd DCA ANE1983 k =f'a�"�+ ` Nieminen,P.E on 10/09/2017.This does not serve as anr'
electronically signed document.
CERTIFICATION.OF INDEPENDENCE:
1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated'orcontrolled byany company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in anyother entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinityl ERD:nor Robert Nieminen, P:E.are, in any way,.the Designer of Record for arty
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design.guidance unless retained
specifically for that purpose.
I
I
TRINITY J ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
I
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance.Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated
compliance with the following,sections of the 6th Edition (2017) Florida Building Code and.Florida Building Code,
Residential Volume through testing in accordance with the following Standards'. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1507.2.5;R905.2.4 Physical Properties ASTM D3462 2010'
1507.2.7.1,R905.2.6.1 Wind ResistanceASTM D3161 2016
1507.2.7.1,8905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Entiy Examination Reference, Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3. 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA202613 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals.&Wind Resistance 4786093137 02/01/2014
ULLLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1591) FBC HVHZ'Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service'Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:-
4.1 Asphalt Shingles:
4.1.1 Classic and Supremem are fiberglass reinforced,3-tab asphalt'roof shingles.
4.1.2 Berkshires are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 DevonshireTM are fiberglass reinforced,,5-tab asphalt roof shingles.
4.1.4 Duration®, TruDefinitions Durations, Durations Premium 'Cool, TruDefinitions Duration® Designer Color
Collection, TI`ubefinitionsOakridge, Oakridge* and Weather.Guard® HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
®
4.2.1 Berkshire Hip&:Ridge'Shingles, High Ridge,WeatherGuard HP Hip &'Ridga Shingles, ProEd ga HipRidge
Shingles and DuraRidgell Hip&Ridge Shingles are fiberglass reinforced,.hip and ridge asphalt roof shingles.;'
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. 5.1 1MITATThis is a buildingcode evaluation. Neither Trinit ERD nor Robert Nieminen P.E. are in an way, th
Y� Y Y, e
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permittinIg or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product..
I
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118
Certificate of Authorization#9503 6TM EDITION(2017)'FEIC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of'8
�I
i
(-)o
TRINITY ERC)
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 15073.7,4
and 11905.2.6:1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable
for use in all wind zones Up to VaSd = 150 mph (Vk,it = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and 11905:2.6:1 to ASTM D3161, Class F, indicating the
shingles are,'acceptable for use in all wind zones up to Vasd=150 mph (V„it=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C,as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 611320-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4.or R905.2.3.
6_2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or -R905.2.6, with the following
exceptions:
Berkshire shingles require minimum five(5)nails per shingle.
➢ WeatherGuard HP shingles require minimum six(6)nails per shingle.
➢ Devonshire'"shingles require minimum six(6)nails per'shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.25. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are'
i
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Feltunderlayment Deck Fettundertaynwrt Deck Self-adhered
Wase ed4cm
SeU adhered undodaymerd
Weatherlocke i
undmlaj ment
Dripedge= .' Q4 edge edge
redge �.
r,t�r
r-
Nails located '
2°-3°trOT e9Ye
2t-.3*from one i
Install first adhesive
` gStarterStpositioned With
Istlremoved
shinglesvisrStripflu �b e
6"removed \ \\
Starter Strip shingle overhangs eaves mrd mikes?ri-vi Stertrar Strip l'kkaavmhangs raves and tikes 1/4'-Y/4"
I
i
Exterior Research and Design,LLC: Evaluation Report.037940.02.12-RB
Certificate of Authorization 119503 6T"EDITION(2017)FBC.NON-HVHZ EVALUATION FL10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of18
I
I
i
i
I
ERS
TRINITY J
6.2.6 Minimum Nailing—Classic®&Supreme:
NormI -Nlaensrd or Arra para Normal Mons"or Arse pane
Wind Arens Niel+Wtnd -desvanrs y VAnd Bron, ffigh VInd desvanas y
Areapin vhWtoa normales Areas vientor fwrtes Ana.pam"vMnroa eormalea A4m wer'.fwrMs
r- r tA} r r 2- 4B z• r
tz�
i I
W Exposur6 5 WW Exposure
Exposiei6n Expoaitldn
6.2.7 Minimum Nailing-Berkshire®:
j
SealaN:strip' Seelaot drip
1a iirada sewor /to tka de sAdar
�" fi Yz• 9 Yf 9 Lj 8 ve 8
r i
i
Standard Fastening Pattern 6-Nail Fastening Pattern
Seafad3trip
to ffra de seilador
�«—�r f—►a>rte--►r�--�a
i
"tL�:S.Yf AYf 8Yt; 8Yf i
t"
r
rte.
JlsphatCroofingcemerit
l:erimpto de teedo ifs astetto
Mansard or Steep Slope Fastening Pattern
i
I �
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118
Certificate of Authorization#9503 6m EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:.30/09/2017
Page 4'of 8
i
i
I
I
TRINITY EKL)
6.2.8 Minimum Nailing—DevonshlreT"":
I I
a n n e n
NMI
Nails
T:
All
_ - ...
317
5518°exposure..
&eai�ltlocadon
Fxposkibli de 5 418 ping I.lWad6n del sellador s s
Ten 1"Spots of Asjihalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition
Duration Designer Color Collection:
4-NaII.Fastening Patter - - - 6diallFastening,Pd"
4aN611AMbnlrtp area rARh" Smetta9&hlfaNnp ansa fiWh
i------
�^ 1r L 1r 1r 1r i r
&U9"6318"- Y'.�: ''a s 6119"9•G9"
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening foi-$Ugm_Gtester Than 21:12
- - - _ eu•t1.iIDa.hnhg aia"wWM
N�rypka
1• 1r 1r
a116'ssle•
SM"I
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118
Certificate ofAuthorization 1!9503 6EDITION(2017(FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8.
i
i
C-)o
TRINITY I ERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard® HP Hip and. Ridge Shingles.
and ProEdge Hip & Ridge Shingles.shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidge"" Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations,.including the use of hand-sealing for
Wind warranties.
6.3.2 Fasteners shall be in accordance.with the manufacturer's published requirements, but not less than F,BC
1507.2.6 or 11905.2.5. Staples arenotpermitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 4 Fig.2
E— PirnpValq -
D'veoectl tlon F- TupView SIae1lieyi
Na➢s—�--�-1 A- Nails-.. - - .Nails
�.. 4 T•.21 Z- t-
Top LaMnat_ed
3'- 'Piece
1 1
\ �p
P 1 1 I I
�F�SOfe n I
ul
I
1
1
1
6.3.4 Minimum Nailing—WeatherGuard°HP Hip and Ridge:
Fig.A 44
Fig.C Hip&Ridge Shingle Fasteni ng
Wind TopVpvr
Pl�eraedlg
f—Dln3ctbn A
A I
Nails_ 4 q
a i i
Nails Nails
P I 1 T•
z• 2" -
I 1 I I
•Y i ♦ w
\ SFYposure i
\ I 17'
I
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6TN EDITION(2017)FBC-NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 0'f'8
I
rTRINITYI ER,
i
6.2.1 Minimum Nailing—TruDefinition Oakridge®,Oakridge®:
4 Nail Pattern '6'Nall iiattem
Squema con 4 elavos Esquema coir 6 caws
T' �.
IE-- tr --sl It— iz—�I IF � =>1 IE— re-'�►{
�,A
5518", posure Nails 65iS"Ezposute Wails
&pasid6ndo55/8pu1g. Claw, Expasitl¢nde55/8pulg.. 55/8 Expos.. 6law$ 5liffEzposure
Expasian de 5618 ping Fxposieion de 5 5/8 yu1g.
Standard Fastening Pattern 6-Nail Fastening Pattern
fastening for.SlopesGreater Than 21.12
suAuws rnan6p cfa rtUst
NA tYpbm
- I
tam- ,y
y I
x t Tr
vau V spot WAspMd Roo"C4WAM
i
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuar&HP:
�■ 1 slug lr♦tild•View
I
.�.'. X.a� .may^.* Irtil�wra�'Ihew>�tMrl�!
Exterior Research and Design,LLCi Evaluation Report 037940.02.12-118
Certificate of Authorization 1!9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 ofi 8
I
I
rTRINI-ry JERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
PrevaRinp Standard X19'
Wind Dintion Fasm patternm
• sswlam
92° i
Ftatna 7'h 7'h"1 8•
�iflt -Y ;
A
6.3.6 Minimum Nailing—DuraRidgelm Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Top View
,Vw en pl-
®iraad�u�ri prc�Ciiiunm T I' vhUz pe1W I-
I
Na
2'le sy.1# s„ rseo
Is.
4
E
I
' I
F
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in_order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com
i
END OF EVALUATION REPORT-
Exterior
EPORT-Exterior Research and Design,LLC.'; Evaluation Report 037940.02.12-118
Certificate of Authorization#9503 6EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of i3
I