Loading...
HomeMy WebLinkAboutProduct Approval I� REVISIONS REV DESCRIPTION DATE APPROVED A REVISED PER NEW REQUIREMENTS 12/04/14 R.L B REVISED ANCHORS 03/27/17 R.L NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 4. FRAME MATERIAL: EXTRUDED RIGID PVC. FILE L;%.;PY 5. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 3 FOR GLASS DETAILS. 6. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. RECEIVED 7. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE 1 V L SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 6 FOR ANCHORING THROUGH WITH SUFFICIENT LENGTH TO I ACHIEVE N INTO WAOD FRAMING MINIMUM EMBEDMENT INTRO SUBSTRATES 0 C T 0 4 2019 LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 9. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD ST. Lucie County, Permitting SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 10. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 11. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 12. ALL FASTENERS TO BE CORROSION RESISTANT. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 (OR GREATER). SIGNED:03/27/2017 D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 .048" THICK MINIMUM PIO. oX INC` \\\`\5�1t�►t iC o MORGANTOWN, PA 19543 •-.'GENs�9s//� OCEANVIEW IMPACT SINGLE HUNG WINDOW _*• 0„61261 *= 48" X 72" TABLE OF CONTENTS FRAME ELEVATION AND NOTES -;:�0, TAT OF SHEET NO. DESCRIPTION ���`•• OWC N0. REV //��s. QR��.•�,�\�� 1 NOTES A.S.DRAWN: 08-01481 B �i�/S/DNA It�t��\��O 2 ELEVATIONS SCALE NTS 03/05/12 1 OF 7 // 3 CROSS SECTIONS AND B.O.M. L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 FL No.: 62514 4 — 7 INSTALLATION DETAILS 434-M-0609 rllomas@ldomaspe.com r, REVISIONS REV DESCRIPTION DATE APPROVED 48" MAX FRAME WIDTH AX F 13" A REVISED PER NEW REQUIREMENTS 12/04/14 R.L. 48" MAX FRAME WIDTH 1 M MAX O.C. 1" MAX B REVISED ANCHORS 03/27/17 R.L. 6" MAX MAX.80.C. 6" MAX. 1" MAX 6" MAX. 13" O 13" MAX / O / MAX O.C. MAX. / O.C. T 72" 72" I FRAME M,kX HEIGHT FRAME HEIGHT Q X � X � 1" MAX OCEANVIEW SINGLE HUNG WINDOW OCEANVIEW SINGLE HUNG WINDOW EXTERIOR VIEW EXTERIOR VIEW FRAME FLUSH INSTALLATION FIN INSTALLATION DESIGN PRESSURE RATING IMPACT RATING ±50PSF LARGEAND SMALL SIGNED:03/27/2017 MISSILE IMPACT VIWINCO INC. ���iu l UIIIi/ MISSILE LEVEL D,WIND ZONE 3 P.O. BOX 499 MORGANTOWN, PA 19543 OCEANVIEW IMPACT SINGLE HUNG WINDOW _*• 0 61 = 48" X 72" — ( r ELEVATIONS TATE OF ,p P�. A.S. Dwc No. 08-01481 Rg ZOR10.G\�` SCALE NTS DATE 03/05/12 SHEET 2 OF 7 L.ROBERTO LOMAS RE Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NO 27023 FL No.: 62514 434-688-0609 dlomas@lAamaspe.com PARTS LIST REVISIONS NO. PART NUMBER DESCRIPTION MANUFACTURER MATERIAL 1 REV DESCRIPnON DATE APPROVED 1 8917 HEAD Deceuninck PVC a I I❑ A REVISED PER NEW REQUIREMENTS 12/04/14 R.L 2 8911 SILL Deceuninck PVC ��---_I B REVISED ANCHORS 03/27/17 R.L 3 8919 JAMB w/SCREEN NUB Deceuninck PVC 4 8918 JAMB w/o SCREEN NUB Deceuninck PVC 0 Q El 31 5 16609 SILL INTERLOCK Minalex ALUMINUM 6105—T5 I—� 4 24 13 25 3 6 5142 SILL LEG Deceuninck PVC jJ ��J 11 20 7' 8640 UPPER SASH BRACKET Four—Jaks DIE CAST 29 23 22 30 ❑ INTERIOR 8 3515 WEATHER STRIPPING — SILL LEG UltraFab WOOL PILE �� ❑ 9 7531 SASH STOP Central Plastics PVC 19p ° 10 5303 SASH LIFE RAIL 18 L BTM Deceuninck PVC � � o En 11 5313 TOP SASH RAIL Deceuninck PVC EXTERIOR INTERIOR o 0 12 5307 STILES —TOP SASH Deceuninck PVC ❑ rawl 13 5306 STILES — BTM SASH Deceuninck PVC 34 14 p r� 14 5308 LOCK RAIL Deceuninck PVC 36 15 5309 KEEPER RAIL Deceuninck PVC 27 0 28 EXTERIOR 16 5146 BULB SEAL Deceuninck PVC 17 5144 GLAZING BEAD Deceuninck PVC 17 10 32 12 HORIZONTAL SECTION 12 18 6608H BARNEY BOLT Pennex ALUMINUM 6105—T5 19 8600 BARNEY SUDE BOLT Four—Jaks NYLON 35 0 8 15/16" 20 8625 BOTTOM BUTTON Four—Jaks PVC 3/32 ANN. 21 — IMPACT CUP Four—Jaks PVC 16 6 .090" PVB BY KURARAY 22 0650 CAM LOCK W/ LUG Four—Jaks DIE CAST 5 1/8" TEMP. 3/32" ANN. DESICCANT FILLED 23 8670 KEEPER Four—Jaks DIE CAST a STAINLESS STEEL SPACER(SU—D) 24 8718 BALANCE SPRING ASSEMBLY Four—Jaks STAINLESS STEEL 33 p 2 EXTERIOR INTERIOR 25 8750 PIVOT BAR Four—Jaks DIE CAST 1/2" BITE 26 8121 NITS LOCK Romai PE VERTICAL SECTION STRUCTURAL SEALANT 27 7240T SETTING BLOCKS TB Philly VINYL DOW INSTAGLAZE SETTING BLOCK 28 3462 SILICONE DOW (TB PHILLY) SILICONE 29 3715W KEEPER SCREW FH #6 (#5 H) X 1" Merchants STAINLESS GLAZING DETAIL 30 371OW LOOK SCREW FH #6 X 1" Merchants STAINLESS SIGNED:03/27/2017 31 13707 BALANCE COVER SCREW FH6X1-1/4" Merchants STAINLESS VIWINCO INC. ``�11111�1IICl/l���/ 32 3738 PNOTBAR SIDE SCREW FH #5 X 3/8 Merchants STAINLESS P.O. BOX 499 ���`J\�?.• •��1�/i/ 33 3732 PIVOT BAR BTM SCREW PH#6X3/8 Merchants STAINLESS MORGANTOWN, PA 19543 `r••��CENS"�9sT 34 4195 SCREEN RAIL Leading Edge ALUMINUM 6105—T5 OCEANVIEW IMPACT SINGLE HUNG WINDOW =*• 0 51 35 3285 FIBERGLASS SCREEN PHIFER FIBERGLASS SCREEN p 48" X CTI — �( "�` CROSS SECTIONS ���TATE OF ;�,� 36 3260 SPLINE DAPA VINYL ��( DRAWN: DWC NO. REV 37 3245 ICORNERS Hygrade I DIE CAST II� A.S. 08-01481 38 14060 UFr TABS Anlin ALUMINUM 6105—T5 scALE NTS — 03/05/12 --3 OF 7 !!111111111 L ROBERTO LOMAS P.E. LUIS R. Lomas P.E. OPTIONAL NFRAME f432WOODFORDRDLEWISVIf1E,NO27023 FL No.: 62514 434-668-0609 rllomas@Irlomaspe.com 1/2" MIN. REVISIONS EDGE DISTANCE { 3/4" MIN REV DESCRIPTION DATE APPROVED WOOD FRAMING METAL I I EDGE DISTANCE A REVISED PER NEW REQUIREMENTS 12/04/14 R.L. OR 2X BUCK STRUCTURE I I B REVISED ANCHORS 03/27/17 R.L. BY OTHERS 1 1/4" MIN. BY OTHERS EMBEDMENT 1/4" MAX SHIM SPACE INTERIOR SEALANT 1/4" MAX. SEALANT 1/4" MAX. EDGE DISTANCE APPROVED � APPROVED � i o SHIM SPACE � SHIM SPACE t o #10 WOOD ❑ SJ ❑ a ❑ U ❑ #10 SMS OR o 0 SCREW SELF DRILLING SCREWS METAL C3 SS SELF DRILLING STRUCTURE SCREW BY OTHERS APPROVED SEALANT EXTERIOR JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION EXTERIOR INTERIOR EXTERIOR INTERIOR 1 1/4" MIN. 1/4" MAX. G— EMBEDMENT DMENT r SHIM SPACE. INTERIOR 1/2 MIN. � EDGE DISTANCE 0 SILL TO BE SET SILL TO BE SET ON A BED OF ON A BED OF #10 WOOD SCREW O APPROVED SEALANT APPROVED SEALANT p WOOD FRAMING OR 2X BUCK 1/4" MAX. BY OTHERS APPROVED APPROVED SHIM SPACE APPROVED SEALANT SEALANT �o ❑ SEALANT �� ❑ 1/4' MAX, JAMB INSTALLATION DETAIL EXTERIOR WOOD FRAMING � �SHIM SPACE WOOD FRAMING OR 2X BUCK INSTALLATION OR 2X BUCK BY OTHERS METS SIGNED:03/27/2017 STRUCTURE BY OTHERS l P.O.N 00 499�� J�S R I 10 z�i//. VERTICAL CROSS SECTION MORGANTOWN, PA 19543 v,•�,�GENSF9d+ VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION OCEANVIEW IMPACT SINGLE HUNG WINDOW *• 0,.61261 WOOD FRAMING OR 2X BUCK INSTALLATION 48" X 72" FRAME INSTALLATION DETAILS ::-P- STATE OF 0 . NOTENTERIORAND EXTERIOR FINISHES,BY OTHERS, EV A.S.S: DRAWN: owO NO. 08-01481 RB / �S's o..-'tv\y\`� 1. NOTSHOWN FOR CLARITY. ' NTS DAA 03/05/12 4 OF 7 /iiIIINAi„`\�� 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE 3 R05/1 COMAS P.E. DESIGNED/N ACCORDANCEW/THASTME2f12 L.1432WOODFORDRDLEMS 14LMNC27023 Luis R. Lomas P.E. 434-MB-0609 dlnmas@ldomaspe.00m FL No.: 62514 2 1/2" MIN. REMSONS EDGE DISTANCE REV DESCRIPnON DATE APPROVED CONCRETE/MASONRY A REVISED PER NEW REQUIREMENTS 12/04/14 R.L. BY OTHERS o '••, oa. B REVISED ANCHORS 03/27/17 R.L e° 1 1/4" MIN. OPTIONAL.1X BUCK ° • , . °' ` EMBEDMENT TO BE PROPERLY a e' 1 1/4" MIN' SECURED — � EMBEDMENT SEE NOTE 3 SHEET 1 CONCRETE/MASONRY BY OTHERS APPROVED 1/4" 0 ;, y 1/4" MAX. SEALANT SHIM SPACE OPTIONAL PROPERLY .` SHIM SPACE SECURED ° 1/4" TAPCON Q SEE NOTE 3 SHEET 1 • °a ❑ ❑ 1/4" TAPCON INTERIOR .e' • a 0 .,a 6 2 1N. EXTERIOR I •' �� 0 INTERIOR EDGEGEG1 0 � � DISTANCE .a O APPROVED EXTERIOR SEALANT JAMB INSTALLATION DETAIL CONCRETEMASONRY INSTALLATION SILL TO BE SET NOTES: APPROVED ON A BED OF 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, SEALANT APPROVED SEALANT NOT SHOWN FOR CLARITY. 2 PERIMETER AND JOINT SEALANT BYOTHERS TO BE o OPTIONAL 1X BUCK 1/4" MAX, DESIGNEDINACCORDANCEWITHASTME2112 SIGNED:03/27/2017 � TO BE PROPERLY ❑ SHIM SPACE SEE NOTE 3 SHEET SECURED 1 P.00. BOO INC. `\J`s l¢IICQ ��i,// MORGANTOWN, PA 19543 �v,• �CENs 9iP�. CONCRETE/MASONRY ,v� F BY OTHERS '° ° °' g •�< ' . OCEANVIEW IMPACT SINGLE HUNG WINDOW *• 106x *^ •• a a:° <'. FRAME INSTALLATION DETAILS -;:13- TAT TAT OF •tv� d.+' �.•.°; a .. :'ne DRAWN: DWG NO. REV �ii�E`S:cIOR10P O6 scuE NTS DATE 03/05/12 s�T 5 B i9/0 of A OF 7 /,// III11�?\\`` VERTICAL CROSS SECTION L ROBERTO LOMAS P.E. CONCRETEMASONRYINSTALLATION 1432 WOODFORD RD LEWIS VILLE,AID 27023 LUIS R. Lomas P.E. 434-668.0609 /l/omas@Idomaspecom FL No.: 62514 1 1/4" MIN. REVIMONS EMBEDMENT REV DESCRPNON DATE I APPROVW #8 WOOD WOOD A REVISED PER NEW REQUIREMENTS12/04/14 R.L SCREW FRAMING BY OTHERS B REVISED ANCHORS 03/27/17 1 R.L. 1/4" MAX. SHIM SPACE 7/16" MIN EDGE DISTANCE � �r-I WOOD FRAMING 1/4" MAX BY OTHERS I SHIM SPACE ❑ it ❑ #B.WOOD SCREW INTERIOR 1 1/4" DO� o MIN. EXTERIOR INTERIOR EMBEDMENT o D 7/16" MIN EDGE DISTANCE EXTERIOR JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, ao NOT SHOWN FOR CLARITY. 1/4- MAX 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE Q F SHIM SPACE DESIGNED INACCORDANCE WITHASTME2112 SIGNED:03/27/2017 EDGEI6- MIN DISTANCE Id WOOD PIOINBOOINCX 499• ``\�)ro II�0 /z #8 WOODFRAMING MORGANTOWN, PA 19543 `ter•��GENSF9d+��� SCREW 1 1/4" MIN. BY OTHERS OCEANVIEW IMPACT SINGLE HUNG WINDOW *• 0,.81261 yt= EMBEDMENT 48" X 72" — ( lF VERTICAL CROSS SECTION FIN INSTALLATION DETAILS` STATE OF ;.N` WOOD FRAMING OR 2X BUCK INSTALLATION DRAWN:ADWO NO. OS-01481 RB Sr�Le NTS DATE 03/05/12 1 SNIT 6 OF 7 1//11111II0�`` L ROBERTO LOMAS P.E. LUIS R. Lomas P.E. 1432 WOODFORD RD LEMSVILLE,NO 27023 FL No.: 62514 434£88-0609 r8omas@lrfomaspacam REVISIONS REV DESCRIPDON DATE APPROVED ��--1 7/16 --j A REVISED PER NEW REQUIREMENTS 12/04/14 R.L ---777--- D El B REVISED ANCHORS 03/27/17 R.L T f � L o 2' I 3^ 2" 3" 1 1/ 1 3/4" 1 7/16" 3/4" a �❑ 1 1/8" 4 1/16"--I I--3 1/4 —� �--3 1/4-—� �—2 1 166" 1 1/4' 1 3/4" o� j I Frame Sill Frame Head Frame Jambs VTop Sash Rail VINYL PVC.059 THICK 5/8 F—1 5/8" c A I VINYL PVC.069 THICK VINYL PVC.069 THICK VINYL PVC.069 THICK Upper Sash Meeting Rail VINYL PVC.059 THICK Lower Sash Meeting Rail VINYL PVC.059 THICK i�q 0 o o 1 3/4" 1 7/16" 1 7/16" Le—I 1 1/8- 1 1 1/8- � L f_----�f 5/8" Frame Sill(Nailing Fin) Frame Head(Nailing Fin) Frame Jambs(Nailing Fin) Lower Sash 111 VINYL PVC.069 THICK VINYL PVC.069 THICK VINYL PVC.069 THICK Lift Rail Lower Sash Stiles Upper Sash Stiles VINYL PVC.059 THICK VINYL PVC.059 THICK VINYL PVC.059 THICK 3/8" 7' _E1/8" 15/16" x..-.3/16" 1 1/16" �-- --� 5/8 �T 7/16" Sill Riser Reinforcement Glazing Bead Bulb Seal VINYL PVC.059 THICK Aluminum 6105 TS Anadized .060 THICK VINYL PVC.059 THICK VINYL PVC.059 THICK SIGNED:03/27/2017 WINC INC P.00. BOOX 499• ���\\J\?`RE�Lo MORGANTOWN, PA 19543 v�•�\G NSF.J+ OCEANVIEW IMPACT SINGLE HUNG WINDOW _*• a 51� *_ 48" X 72" -.ptiyttro .� Z: COMPONENTS ;�. TAT OF �tvr� A DRAWN: R DWC NO. OS—014S1 B sc1LE NTS I DATE 03/05/12 1 sHEET 7 OF 7 L.ROBERTO LOMAS P.E. P.E. Lomas Luis R. L 1432 WOODFORD RDLEWISVILLE,NC27023 FL Noas P 434-688-0609 Alomas@Wmespacom Florida Building Code Online Page 1 of 4 vF ; SCIS Home ` Log In ; User Registration 1 Hot Topics Submit Surcharge I Stats&Facts Publications Contact Us i SCIS Site Map i Links I Search Florida r Product Approval � USER;Public User Product Approval Menu>Product or ADphCation Search>Application List>Application Detail -- ((��LL_��''^^ y'�/�D FL# FL20468-R3 Application Type Revision 0 4 2U�g Code Version 2017 OCT Application Status Approved ST. Lucie County, Permitting Comments Archived Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton,OH 43517 (419)298-1740 rickw@rwbldgFnsull cpm Authorized Signature Vivian Wright L 'Xwm 1�0 PY rickw@rwbldg n Er 6 Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect,or a Licensed Florida Professional Engineer 1_1 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J.King,P.E, IA Validation Checklist-Hardcopy Received Certificate of Independence FL20468 R3 COI (c)Certificate of Independence odf Referenced Standard and Year(of Standard) Standard Year AAMA/W DMA/CSA 101/I.S.2/A440 2005 ASTM E1886 2005 ASTM E1886 2002 ASTM E1996 2009 ASTM E1996 2006 ASTM E1996 2002 ASTM E1996 2005 ASTM E330 2002 TAS 202 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL20468 R3 Eauiv EQUIVALENCY OF STANDARDS.pdf httD://www.floridabuilding.oriz/pr/pr app dtl.aspx?param=wGEVXOwtDasJ9a49YAeXJv... 10/1/2019 Florida Building Code Online Page 2 of 4 f Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/09/2018 Date Validated 10/11/2018 Date Pending FBC Approval 10/21/2018 Date Approved 12/11/2018 Summary of Products FL# Model,Number or Name Description 20468.1 a.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.1 for Design Pressure Ratings, any FL20468 R3 AE (c)Eva[20468 1.odF additional use limitations,Installation instructions and product Created by Independent Third Party: Yes particulars.(For Fiber-Classic and Smooth-Star Door panels, this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.2 b.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s)(Inswing/Outswing; XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 II (e)Inst 20468 2 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F, Schmidt,P.E,43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20468.2 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468 2.odf additional use limitations,installation Instructions and product Created by Independent Third Party: Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of Installation.) 20468.3 c.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 fI (e)Inst 20468 3 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20468.3 for Design Pressure Ratings,any FL20468 R3 AE (d) Eval 20468 3 odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars, (For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of part numbers for these doors,which have been stained or painted within six months of installation.) 20468.4 d.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 iI (e)Inst 20468 4 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20468.4 for Design Pressure Ratings,any FL20468 R3 AE (c)Eval 20468.4.odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars.(For Fiber-Classic and Smooth-Star Door panels, this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.5 e.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s)(Inswing/Outswing; X0,OX or OXO configurations) http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXOwtDasJ9a49YAeXJv... 1 o/1/2(119 Florida Building Code Online Page 3 of 4 Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.5.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20468,5 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.5.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. (For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of Installation.) 20468.6 FfTOI.erma-Tru Fiber Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass h-Star Double Door with or without Sidelites(Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use In HVHZ: No FL20468 R3 II (e)Inst 20468.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Create b Independent Third Party: Yes Design Pressure: N/A Eva is Other:See INST 20468.6 for.Doe, n Pressure Ratings,any FL20468 R3 A val 20468.6. df additional use,imitation ' stallation instructions and product Created by Independen ird Party: Yes particulars. (For Fi -Classic and Smooth-Star Door and Sidelite panel is product approval requires the use of"J" part num s for these doors,which have been stained or paint ,thin six months of installation.) 0468.7 g.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Com s e Edge Fiberglass Smooth-Star .n le Door(Inswing/Outswi con uration) Limits of Use I stallation Inst ctions Approved for use in HVHZ: No FL20468 R3 II (e)Inst 20468.7.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.434 9 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.7 for Design Pressure Ratings,any FL20468 R3 AE (d) Eval 20468.7.odf additional use limitations,installation instructions and product Created by Independent Third Party:Ye particulars.(For Fiber-Classic and Smooth-Star Door panels, this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 0468.8 h.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed C posite Edge Fiberglass Smooth-Star Single Door with Sidelite(s) swing/Outswing; XO,OX or OXO configurations) Limits o I e Installation Instr*11111.'.s Approved. se in HVHZ: No FL20468 3 e Int 20468,8. df Approved for u tside HVHZ:Yes Verifle . Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes ated by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: See INST 20468.8 for Design Pressure Ratings,any FL20468 R3 AE (d) Eval 20468.8.odf additional use limitations,installation Instructions and product Created by Independent Third Party: Yes particulars. (For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.9 I,Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass Smooth-Star Double'Door with or without Sidelites(Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.9.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.9 for Design Pressure Ratings,any FL20468 R3 AE (d) Eval 20468.9.0f additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. (For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.10 j.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.10.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F, Schmidt, P.E,43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20468.10 for Design Pressure Ratings,any FL20468 R3 AE (d)Evai 20468.10.odf additional use limitations;Installation instructions and product Created by Independent Third Party: Yes particulars. (For Fiber-Classic and Smooth-Star Door panels, htt-o://www.floridabuilding.org/pr/pr app dtl.as-ox?param=wGEVXOwtDasJ9a49YAl?XJv... 10/1/2019 Florida Building Code Online Page 4 of 4 this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.11 k.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s) (Inswing/Outswing;XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 II (e)Inst 20468 11 DdF Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.11 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468 1l Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. (For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"Y' part numbers for these doors,which have been stained or painted within six months of installation.) 20468.12 I.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 iI (e)Inst 20468 12 pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.12 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.12.odf additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars. (For Fiber-Classic and Smooth-Star Door and Sidelite panels, this product approval requires the use of"I" part numbers for these doors,which have been stained or painted within six months of installation,) Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Cooyriaht 2007.2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: M ® ® we:k M Credit Card Safe htti)://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXOwtDasJ9a49YAl?XJv.,. 10/1/2019 RECEIVED OCT 0 4 299 R R IV Building Consultants Inc, T ucie County, PermNR9jl ing and Engineering Services for the B i din MM�3 C C try P.Q.Bos 230 Valrico,FL 33595 Ph..813. 9.919 t OPY Florida Board of Professional Engineers Certificate of Authorization No.9813 / WIMATMEMIUMNIMMIME Emu= Product Sub Category. Manufacturer Product Name Category Swinging Therma Tru Corporation Fiber-Classic and Smooth-Star Exterior Exterior Door 118 Industrial Drive Composite Edge Glazed Fiberglass Single Door Doors Assemblies Edgerton,OH 43617 InswinglOutswing Phone 419.298.1744 "Impact' Scope: This is a.Product Evaluation report issued by R W Building Consultants, inc.and Lyndon F.Schmidt, P.E.for Therma Tru Corporation based on Rule Chapter No.61 G20-3,Method 1.D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt, P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition(2017).Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"Wand includes Wind Zone 4 as defined in ASTM E1996 and FBCSections 1609.1.2.2&R301.2.1.2.1. 4, For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5.-Site conditions that deviate from the details of drawing FL-20468.7 require further engineering analysis by a licensed.,engineer or registered architect. 6. Fiber-Classic&Smooth-Star Door panels require the use of"J"part numbers and must be stained or painted within six months of installation 7. See drawing FL-20468.7 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01460274 ASTM E1886-05,E1996-05 Testing Evaluation Lab.,Inc. V.K.Wright ASTM E330-02, E331-00 TEL 06-0718-1 101/I.S.2/A440-05 Testing Evaluation Lab.,lnc. V.K.Wright ASTM E1886-02, E1996-02, E330-02 TEL 01460130 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc. V.K.Wright ASTM E1886-02, E1996-02 TEL 01461612 ASTM E1886-05,E1996-09 Testing Evaluation Lab.,lnc. V.K.Wright ASTM E330-02, E331-00 2. Miami Dade NOA Materials Testing. 16-1117.01 Butacitell PVB Interlayer(Kuraray) 17-0712.05 Saflex®PVB Interlayer(Eastman Chemical Company) ,�s,��ao�t3srs -ine 3 Drawinci No. Prepared bySic No. FL-20468:7 RW Building Consultants,Inc.(CA#9813) r,�grrr } �"r`f 'N"o Lyndon F.Schmid&Sealedt P.E. 4. Calculations Prepared by wQ a �. "" 4ogned&Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) rlo 43409 �,Cyndon F.Schmidt, P.E. 5. Quality Assurance zk Certificate of Participation issued by National Accreditation and g Management Institute,certifying that Therma Tru Corporation is1; STATE OF L noon F.Schmidt,P.E. manufacturing products within a quality assurance program that complies ��, �• 4 t7 � �'0 Y FL PE No.43409 with ISO/IEC 17020 and Guide 53. dais 0 R ,• �r 12/14/2017 Sheet 1 of 1 po�eB¢'I� jN,�arrr° \\\luulrrllp THERMAITRU® DOORS _ � - ?�= d Fiber-Classic. & Smooth-Star. ��� 1 {Ill \\ u! •i tomo o U N- -Z p v a Z a $ o Em o'.y 9° c w COMPOSITE EDGE 37,75"MAX a` r^n 0 4tm a a a di r FRAME WIDTH c 4 a m GLAZED FIBERGLASS SINGLE DOOR I �_ CW O ja INSWING/OUTSWING a 'IMPACT' - 2 GENERAL NOTES i Fo zo � z 1. This product has been evaluated and is in compliance with the 6th Edition z ¢r` (2017)Florida Building Code(FBC)structural requirements excluding the"High <z Velocity Hurricane Zone(HVHZ). O rn 2 �/ ® f-m !Q ¢W� 2 Product anchors shall be as listed and spaced as shown on details.Anchor .w 0 /` o Ua embedment.to base material shag be beyond wall dressing or stucco. N w c!= of r=W �< mg < a 3. When used in areas requiring wind bome debris protection this product LL < 7 a a E complies with FBC Sections 1609.12&R301212 and does not require an impact resistant covering.This product meets missle level"D"and includes Wind m Zone 4 as defined in ASTM,E1996 and FeC Sections 1609"122&R3012121. w � E Z m 4. For 2x stud framing construction,anchoring of these units shall be the same as Z o Y that shown for 2x buck masonry construction. 0 a o S. Site conditions that deviate from the details of this drawing require further a z o .z 3 w W O engineering analysis by licensed engineer or registered architect. Z:E Ln o_Qa� 6. Fiber-Classic&Smooth-Star Door panels require the use of"J"part numbers andir poll C must be stained or pointed within sbc months of installation. o 1 F eK Aiwa d a TABLE OF CONNNLS ? DESIGN PRESSURE(PSI) DESIGN PRESSURE(PSI) - a SHEENDFSCRIPUON CONFIGURATION LOCK INSWING OUTSWING HARDWARE = r- I Typical Bevations,Design Pressures&General Notes w POSITIVE NEGATIVE POSITIVE NEGATIVE ���a 2 Door Panel Details 3 Bevatiors X Latch&Deadboft +47.0 -53.0 +50.0 -50.0 0 a 4 Horizontal& Vertical Cross Sections(2X Buck) "r z 5 Horizontal&Vertical Cross Sections(1X Buck) x Muttipoint +50.0 -50.0 +50.0 -50.0 DATE 08/02/16 3 a 6 Horizontal&Vertical Cross Sections(Direct to Masonry) scnrr:- N.T.S. 7 vertical Cross sections(Ihreshalds) See Sheet 3 for Hardware Specifications By. JK m' W 8 Buck&Frame Anchoring 9 Hardware Details CHK.er LFS 10 Glazing Details Danwwc NG: 11 Components FL-20468.7 12 Bill of Materials = WEr_L of 12 G z R:\Olents\Thenna TrU PERMANENT\A-Flodda Product Approvals\FL-20968 WBDR TT FC SS Impact-Composite\C-Drawings\FL 20468(2017)-CURRENT\FL-20468.7-9.dwg,2.1 79,25"MAX.DOOR PANEL HEIGHT N� fT O n Z c O m gC; r;;s< m °ov N W Zz zz Z \`\\ �A00 m ® O T,' o; m ' oz •--� E---s,s' Q 79.25"MAX.DOOR PANEL HEIGHT N N T x ARi OA O O O o �� zW .., n I0 n I 0 N w A C o 0 8' \� 0 H -1 tom—5.5' 79.06'MAX.DOOR PANEL HEIGHT ,� ' NN OO m m 0 0 —10 0 0 —bu 0 00 y « y cq Z ..... X00 ��„ ®� 0 (D1 0 ° g 0 0 a °o � 5,s° Q m m N W 0.82" � � 0.89" H N l7 9O z m0 0 ��a 8rn-u i p G)Z m � r— m Z ^^ Z 7. D \\` H L ��.� F,scHM/ 0.87' 0,89,I��--i /� a L .. �• No.43409 O 2 10/09/18-t%%. PRODUCT: 00.um � anta Praparad Byl QSTATE OF •, r�1 THERMA—TRU Lyndon F. Schmidt ��� �2pR(pl,.•'G\°� IN N 01 FIBERGLASS DOOR P.E. No. 43409 �i�1SS+•"'• O z\ 3 10 08 18 REV. DOOR PANEL OPTION NOTE MT /��IVALIE\\� '' y N 2 11 iS 17 RECESSED PANEL NOTATION JK PART OR ASSEMBLY: GD BUILDING CONSULTANTS, IDo X .0 1 7 17 17 UPDATE TO 8th ED 2017 FBC JK �/�,�/�/�P.O, eoz 230, Valrleo, FL 33595 N m NO DATE BY DOOR PANEL DETAILS •� Phone No.: 813.859.9197 REVISIONS FBPE C.A. No. 9813 2016 R.W.BNILGIND CO NB NLTANTB INC. � R:\Clients\Therma Tru PERMANENT\.•Florida Product Approvals\FL-20468 WBDR TT FC SS Impact-Composite\C-Drawings\FL 20468(2017)-O.JRRENT\FL-20460.7-9.dwg,3.1 A N CNS a N A N v \ p P A Q � A W o n ° Q.0 DIA. U W 7 �a o n m g 0 � 0 + A ° (D=M ° \ :3C) o m v Sao � � D � a m o � p o CD ao '^ ♦ ' � S ..a. ° a 0 r�s1 0 o_ o o a' T. C m m -i m Irl o A to e ;D C114 G No.43409 10/09/1 Q PRODUCT: oecumente Proparod By: ��0• BTATEOF �� rr P THERMA—TRU Lyndon F. Schmidt �j��'•,!20R10�. \� w ru FIBERGLASS DOOR P.E. No. 4J409 1,l , \ J f0 08 18 REV. DOOR PANEL OPTION NOTE MT /i���NAI.V\\\ r ` y N 2 11 15 17 RECESSED PANEL NOTATION JK PART OR ASSEMBLY: GD BUILDING CONSUL7ANTS,1��1�111\\ ILb x ti 1 7 17 17 UPDATE TO 6th EO 2017 FBC JK P.O. Box 230, VDirlco, FL 33595 N v M NO DATE BY ELEVATIONS Phone No.: 813,659,9197 REVISIONS FBPE C.A. No. 9813 ®2C 1 6 R.W.BUILDING CONDULTANTe IND. + L R:\Clients\Thema Tru PERMANENT\A-Flodda Product Approvals\FL-20468 WBDR T7 FC SS Impact-CompositelC-Drewings\FL 20468(2017)-CURRENT\FL-20468.7.9.dwg,4.1 �z M 1, to aN � r �7O-S (0 f Q �n o z m N D I0 PC M A A a ° H O god a ' m V O o p n A 1-1/4"MIN. EMB.(TYP.) n 01 SV z C o Q >< 90 N �£o c-n r) 3 m � o ' •V. p ° m Zi Z r T sCH41 43409 10/09/18' 1 _ Y2 PRODUCT: Documents Prepared 8y: -110, STATE OF •• � N FIBERGLASS DOOR P.E. Noon F43409Sch 1dt '�i, �S, OR401.•�G,`� o $ Z QWDATE REV. DOOR PANEL OPTION NOTE M7 �, Ol�g1.E' rRECESSED PANEL NOTgTION JK PART OR ASSEMBLY: GD BUILDING CONSULTANTS. �UPDATE TO 6th ED 2017 FBC JK P.O. Box 230, VaIrICO, FL 33595 BY CROSS SECTIONS VERTICAL Phone No,: 813.859.9197 REVISIO S LICFBPE C.A. No, 9813 02016 R.W.BUILOINO CONSULTANTS INC. RACljents%TheMa TIV PERMANENT\A Flolida Product Appmals\FL-20460 WBDR TT FC SS IMPact-CoutposfteNC- D,8wIn9s\FL 20460(2017)-CURRENT\FL-20468.7-9.dw9,5-1 M 4-1 4. to N > 0 1. 2 (0 n 0 0 Cr cr 00 M 0 �;u All 0sq G SK r A I�o yW Ln 00 MO 3 n C r) > ff 'Q4 - SCHM No.43409 PRODUCT: 0-Urn me Prvp—d Byl THERMA—TRU Lyndon F. Schmidt P.E. No. 43409 FIBERGLASS DOOR REV. DOOR PANEL OPTION NOTE MT MAI.\\\\\ SULTAN RECESSED PANEL NOTATION— JK PART 0 ASSEMBLY: LOING CONSULTANTS, UP, 9 C31 —1 7 17 17 ATE TO 6th ED F20177 FBC JK Box 230, Voldco, FL 33595 P3 ul A �,�- w HORIZONTAL & rRTlCAL 14 m NO_RATE By CROSS SECTIONS IX BUCK) Phone No.i 813.659.9197 RFV7ISONS FSPE C.A. No. 9813 0 201 6 R.W.BUILDING C—SULTANTR IND. R:\Cllents\Therma Tw PERNANENT\A-Flodda Product Approvals\FL-20468 WSDR TT FC SS Impact-Composlte\C-DrawingsWL 20468(2017)-CURRENT\FL-20468.7.9.dwg,6.1 m a d 2' MAX. CC OtO O tc MIN. 0 �Y a :10 g m Cr t O 09 m A N z g 0 o o A is �O 70 A W N �QN . N o mop Z 0m 10 �n 3 rn 1.25' 07 MIN. Fl A' 1.5"MAX. 4" MAX. gggo o Z Do p 3 MIN. o to z o 0 n a H 0 m O rn n N rn Q � z 0w nom z .. P T N •��o O OHO 0 r 4. �3, t7 vo AO 1.5' 111111 MIN. `�\111 117j� M t' m z 30 z 4.25' ° 1.5'MAX. Lz - ? No.43408 = 10/09/18 $� 4 PRODUCT: DocumanU Prepared 9y: ��f7 6iAT1?OF r'I THERMA—TRU Lyndon F'43409T Schmidt �'�'• II FIBERGLASS DOOR P.E. No. 43409 �i�SS• ��� � ro 3 10 OB 16 RES! DOOR PANEL OPTION NOTE MT �I/7jlO1VAL Ep�� L4 N 2 11 15 17 RECESSED PANEL NOTATION JK PART OR ASSEMBLY: �iDBUILDING CONSULTANTS, Iw X to 1 7 17 17 UPDATE 70 6th ED 2017 FBC JK HORIZONTAL & VERTICAL rJ�,�/(! P,O. Box 230, Valrlco• FL 33595 ry v rn NO DATE BY SECTIONS DIRECT TO MASONRY) Phone No.: 813.859.8197 REVIS ONS FSPE CA, No. 9813 ID 201B R.W.BUILDING aaNaULTANTa INC, R:\OlentsVrherma Tru PERMANENT\A-Flodda Product Approvals\FL-20468 WBDR TT FC SS Impact-Composlte\C-DrawingsWL 20468(2017)-CURRENT\FL-20468,7.9.dwg,7.1 — Z to rn�I r0_ryp � _N 3 3 3 x a� U U�- H1 G' V z o w O o 1-,0o $ mais Ab a C, k 0 O N C Z7 CL • Q W Z1 C OT V U3 v� v ° $ O p n ° xIq m o N z T O.0 v 3.' o m x 03 O °° ° °° 4wt z B z ° G �o .N ° v m �r $ Z � A m N 7r�xr0 o 70 A g > $ con ° •. Ob w A > Z N M its � d 2 ° (n yypppp ° ° 7 G A ° r m rP •• ° ,,j�°,l � p w o. No.43409 '7E 10/09/1 $ 4 $ PRODUCT: Doeumentrr Prepared By, ��Q• BTATEOF FT THERMA—TRU Lyndon F. Bohmldt ':�'� .�COMD�;.•'' \� I FIBERGLASS DOOR P.E. No. 43409 \ J 10 08 18 REV. DOOR PANEL OPTION NOTE Mi ? 17 17 117 UPDATERECESSETOP�E ED NOTATION JK FBC JK PART OR ASSEMBLY: �^ BUILDING Box 2305 Valr�o. FL 3,3595 IN v or NO DATE BY VERTICAL CROSS -tlrllU/Phone No.: 813.859.9197 REVISIONS SECTIONS (THRESHOLDS) FBPE C.A. No. 9813 0 201 6 R.W.BUILDING CCNBYLTANTe INC. R:\CientSkTherma Tru FERMANENS\A-Ftodda Pmduct Approvals%FL-20468 448D0.1T FC SS Impact-Co.poslte\C-Drawings\FL 20468(2017)-CURRENf\FL-20468.7.9.dwg,8.1 -00 s'4 MY z � A � In z . I6"MAX, �y^_�! 4"{TYP.)—►{ O.C.(TYP.) c • 4, m � b = Z C C .517 4 14"MAX. e(TYP.) O.C.(TYP.) O rrox X H N M ? No.43409 = 10/09/18 PRODUCT,. 0000mente Preparod By: • � STATE OF t F� THERMA—TRU Lyndon F. Schmidt �i�''.!20R10�.•''� N R FIBERGLASS DOOR P.E. No. 43409 �tj 2 3 10 08 18 REV. DOOR PANEL OPTION NOTE MT 77/IIIc1011111,f�AL $ r- ` y N 2 11 15 17 RECESSED PANEL NOTATION JK PART OR ASSEMBLY; G]� BUILDING CONSULTANTS, 10 ( 0a T, to 1 7 17 17 UPDATE TO 6th ED 2017 FSC JK BUCK & FRAME ANCHORING eJ1. P'O. Sax 230,Valricc, FL 33595 N v rn NO DATE BY Phon6 No.; 813.859.9197 REVISIONS FSPE C.A. No. 9813 2016 R.W.BUILD—CONSULTANTS lNa. RiWiemskThenna TIC PERMARENT\A-Ronda Product ApprovIIIS\FL-20468 WOOR TT FC SS Impact-Composite\C-DrmvinqS\FL 20468(2017)-CURRENT\FL-20468-7-9.dw9,9.1 Z () n Za' 2 OR Q 0 -0 z n P !�6 C� i 9. 0 z 03 0 (K) ❑ CZ) ❑ tp N DO CD 0 0 Q. CT F-1-sw i 0 — l5. . ak — DO ce —11— 5q� 3: K _44.88"4 I.Sl co z 0 Ve 29.25"(TYP.) —11.25'FROM TOP 2: BOOKDOOR OFJAMB I V/ 29,7S'(TYP,) 11.125"FROM TOP/\ Ul/HYBRIDDOOR OFJAMB to 0 z ti E�- 30.31" 45.25"(t IS-) 0 ov co 05 z O 7% r) I SCHAfl' 0 No.43409 10/09/18::'l PRODUCT., Document.Prepared BY: STAM p 5i THERMA—TRU Lyndon F. Scahmidt FIBERGLASS DOOR P.E. Na. 43409 .....OF I- a fO 08 18 REV, DOOR PANEL OPTION NOTE MT P ?! JK PART ASSEMBLY:11 15 17 RECESSED PANEL NOTATION OR ASSEMB BUILDING CONSULTANTS, 1 7 17 17 iivnATr TO 8th ED (2017) FBC JK d 1.WP.O. Dox 230, Valrico, FL 33595 NO. DATE BT HARDWARE DETAILS Phone No.: 813.659.9197 L�..l CO—ULTANTs INC. REVISIUN—S— I FSPE C.A. No. 9813 R:\0lents\*n'eana Tru PCRMAMeNT\A-Florida Product Approvals¢L-20468 WBDR TT FC SS Impact-CompositekC-Drawlnqs\FL 20468(2017)-CURRENTXFL-20468,7-9.dw9,103 ft 75 X ZR L z 0 0 M Z > 'pi Ct z z 0 63.2Y D.L.O.HEIGHT To ig Z 0 z T 3" (TYP.) 12"MAX.0,C. (TYP.) z > V A M z rn -0 z V) M 0 0 z m 0 I Sc. .....Hu N0.43409 PRODUCT: Docurnanta IlroP—d Bp F. -;,-0, STAM OF THERMA—TRU Lyndon Schmidt !o ril FIBERGLASS DOOR P.E. No. 43409 3 REV. DOOR PANEL OP770H NOTE MT o 1% y N 2 11 15 17 RECESSED PANEL NOTATION JK PART OR ASSEMBLY: BUILDING CONSULTANTS 7 17 17 UPDATE TO 6111 ED 2077 FBC JK GLAZING DETAILS RCWP.O. Box 230, Valrico, FL 33595 14 0) NO, DATE BY Phone No,: 813,659.9197 REVISIONS FSPE C.A. No. 9813 C 2016 R.W.BUILVINc;rONOULTANTS INC. R:\Cjlents%Therma Tru PERMANENT\A-Florida Product Approwls),FL-20468 WBDRrr PC SS Impact-C0.posIte\C-DralngS\FL 20468(2017)-CURRENT\FL-20468.7-9.dwg,11.1 1.29" 1.55, ce % Ln . .... -3 ,X 0 0.082" ca 4, n n 14 0.46'— Or T 1 0 IT L Ft, 0.911, 0 0 P- 0,69'_1 0.7S' SCH S N0.43409 10/09/18Sav", PRODUCT Documents Prepared By:":�O- • STATE OF THERMA—TRU Lyndon F. S.hmidt F'. DOOR E. No 43409 FIBERGLASS REV. DOOR PANEL OPTION NOTE MT RWBUILDIN CONSULTANTS,-N 4 RECESSED PANEL NOTATION JK PART OR ASSEMBLY: 01 G CONSULT �l 7 17 17 UPDATE TO 6th ED (2017) FBC Po w P.O. Box 230, Valrico, FL 33595 IN 14 C) NO. DATE BY COMPONENTS Phone No.: 813.659.9197 REVISIONS FBPE C.A. No. 9813 2016 R.W.BUILOING CcINSULTANTS INC. ``��iurnlrrq BELL OF MATERIALS BILL OF MATERIALS REM# DESCRIPTION MATERIAL ITEM# DESCRIPTION MATERIAL A 1 X BUCK(SG>=0.42) WOOD 25 #8 x 2-1/2 PFH WOOD SCREW STEEL =V'3 ;Co zCM � B 2X BUCK(SG>=0.42) WOOD 26 #8 x 5/B"PFH WOOD SCREW STEEL �i: Z `_` C 1/4"MAX.SHIM SPACE - 27 LATCH STRIKE PLATE STEEL % '•.-_ ,. yy` 0 m. D 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 28 DEADBOLT STRIKE PLATE(STANDARD) STEEL �i >n m MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI 28A DEADBOLT SUB STRIKE PLATE STEELrr rrm z o M o E 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 28B DEADBOLT STRIKE PLATE(SECURITY) STEEL a �N _ G 3/16"X 3-1/4"TTW CONCRETE SCREW STEEL 29 4!'X 4"HINGE STEEL o r$ o m o J 114'X 3-3/4"PFH ELCO OR TTW CONCRETE SCREW STEEL 30 LATCH&DEADBOLT STRIKE PLATE(TONGUE SYSTEM) ALUM/COMP R B m L #10 X 2-1/7'PFH WOOD SCREW[].IS'MIN.EMBEDMENT) STEEL 31 MULTIPOINT STRIKE PLATE(TONGUE SYSTEM) ALUM/COMP a 4 . \a M 3116'X 2-1/4'[TW CONCRETE SCREW STEEL 32 INSWING THRESHOLD ALUM/COMP E a= N 3116"X 2-3/4"ITW CONCRETE SCREW STEEL 33 INSWING THRESHOLD ALUM/COMP 1 JAMB(FINGER JOINT PINE) WOOD 34 INSWING THRESHOLD ALUM/COMP 6 WEATHERSTRIP(MEDIUM REACH) FOAM 35 INSWING THRESHOLD ALUM/COMP 7 WEATHERSTRIP(LONG REACH) FOAM 36 INSWING THRESHOLD ALUM/COMP 8 SWEEP VINYL 37 INSWING THRESHOLD ALUM/COMP �o a 9 SWEEP(USE w/MODERATE CLIMATE THRESHOLD) VINYL 38 INSWING THRESHOLD ALUM/COMP I cn 10 SWEEP(USE w/PUBLIC ACCESS THRESHOLD) VINYL 39 INSWING THRESHOLD ALUM/COMP m 15 PUBLIC ACCESS THRESHOLD ALUM 40 DOOR PANEL(BOOK) 16 OUTSWING THRESHOLD ALUM/COMP 41 DOOR PANEL(HYBRID) - ~III 17 OUTSWING THRESHOLD ALUM/COMP 42 DOOR PANEL(Ul) - of o m 18 OUTSWING THRESHOLD ALUM/COMP a a Zi 22 #8 x 3/4"PFH WOOD SCREW STEEL 8 23 #10 x 3/4"PFH WOOD SCREW STEEL m 24 #10X 1"PFH WOOD SCREW STEEL E O V •• Z Z ILV) o CONCRETEANCHORNOTES., z o 3 1.Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. a n 2 Concrete anchor locations noted as MAX_ON CENTER"must be adjusted to z a o w maintain the min.edge distance to mortarjoinfs,additional concrete anchors o w' may be required to ensure the"MAX ON CENTER"dimension are not exceeded oo 3.Concrete anchor table: w a d :'""'':.,x''.:''`;;;:;;::[:.;..:;;;;;t;:'•;:a11N:..... :.. MIIJ,C..... ANCE, MIN:•CfiE4R%kNCE m n m e ANCHQR ANCHOR TO MASONRY iO ADJACENT". w i "t.Ti'P.� SIjE• EMBEDMENT. o n r a :...................::::..:>.:::...: ::.:...... . :.. :EDGE;: ''ANCHOR':. _2 i� o^^o m g TAPCON® 1/4" 1-1/4" 2" 4" o 0 51N—Z a ELCO ® 1/4" 1-1/4" 1" 4" DATE 08/02/16 z ULTRACON 5 N.T.S. TAPCON / / AS SHOWN 1-1/2" JK it 1TW ® 3 16" 1-7 4" � m WOOD SCREW INSTALLATION NOTES: ' € 1.Maintain o minimum 5/8"edge distance,?"end distance,S 1"o.c.spacing Of MAW= € wood screws to prevent the splitting of wood. FL-20468.7 0 snEEr12 of 12 o — _ d Florida Building Code Online Page 1 of 4 z - SCIS Home Log In I User Registration �, 'Hot Topics 1 Submit Surcharge Stats&.Facts ( Publications i Contact Us SCIS Site Map I Links Search Flanda rProduct Approval r" USER:Public User Product Aooroval Menu>Product or Application Search>Application List>Application Detail a FL# FL R3 F I L E� covw='�"y Application Type Revision Code Version 2017 Application Status Approved RECEIVED _ Comments Archived , i� O C T 0 4 2019 Product Manufacturer Therma-Tru.Corporation ST. Lucie County, Permitting Address/Phone/Email 118 Industrial Drive Edgerton,01-143517 (419)298-1740 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants,com. Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email ` Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered,Architect or a Licensed Florida Professional,Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J. King, P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL20468 R3 COI•(c)Certificate of Independence.odf Referenced Standard and Year'(of Standard) Standard Year - -_` AAMA/W D MA/CSA 101/I.S.2/A440 2005 ASTM E1886 2005 ti ASTM E1886 2002 ASTM E1996 2009 ASTM E1996 2006. ASTM E1996 2002 ASTM E1996 2005 . ASTM E330 2002,,'`•, TAS 202 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL20468 R3 Eauiv EQUIVALENCY OF STANDARDS.pdf http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJv... 10/1/2019 Florida Building Code Online Page 2 of 4 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/09/2018 Date Validated 10/11/2018 Date Pending FBC Approval 10/21/2018 Date Approved 12/11/2018 Summary of Products \ A) Q ` FL# Model,Number or Name Description 20468.1 a.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing;X configuration) _ Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 II (e)Inst 20468.1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.1 for Design Pressure Ratings,any FL20468 R3 AE (c)Eval 20468.1.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door panels, _ this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of Installation.) 20468.2 b.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s)(Inswing/Outswing;XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 II (e)Inst 20468.2.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.2 for Design Pressure Ratings,any FL20468 R3 "AE (d)Eval 20468.2.1)df additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.3 c.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing;XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.3.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20468.3 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.3.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. (For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"Y' part numbers for these doors,which have been stained or painted within six months of installation.) 20468.4 d.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II '(e)Inst 20468.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F, Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20468.4 for Design Pressure Ratings,any FL20468 R3 AE (c)Eval 20468.4.odf additional use limitations,installation instructions and.product Created by Independent Third Party:Yes particulars. (For Fiber-Classic and Smooth-Star Door panels, this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.5 e.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s)(Inswing/Outswing; XO,OX or OXO configurations) http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJv... 10/l/2019 Florida Building Code Online Page 3 of 4 400 Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 II (e) Inst 20468.5.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20468.5 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.5.odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. (For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of Installation.) 20468.6 r2hoerma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass th-Star Double Door with or without Sidelites(Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 II (e)Inst 20468.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.6 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.6.1)df additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. (For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.7 g.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.7.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20468.7 for Design Pressure Ratings,any FL20468 R3 AE (d) Eval 20468.7.odf additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars. (For Fiber-Classic and Smooth-Star Door panels, this product approval requires the use of"J"part numbers for Ir`n these doors,which have been stained or painted within six months of installation.) 20468.8 Eh Tru Fiber Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass tar Single Door with Sidelite(s) (Inswing/Outswing; XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 II (e)Inst 20468.8.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20468.8 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.8.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. (For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.9 rTheo Tru Fiber Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass Star Double Door with or without Sidelites(Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 II (e)Inst20468.9.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.9 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.9.odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. (For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.10 j.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 II (e)Inst 20468.10.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.10 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.10.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. (For Fiber-Classic and Smooth-Star Door panels, http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJv... 10/1/2019 Florida Building Code Online Page 4 of 4 this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.11 FkThermaTru Fiber Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass oth-Star Single Door with Sidelite(s) (Inswing/Outswing; XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R3 II (e)Inst 20468.11.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20468.11 for Design Pressure Ratings,any FL20468 R3 AE (d) Eval 20468.11.1)df additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of installation.) 20468.12 I.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20468 R3 II (e)Inst 20468.12.oddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.12 for Design Pressure Ratings,any FL20468 R3 AE (d)Eval 20468.12.odf additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars. (For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J" part numbers for these doors,which have been stained or painted within six months of installation.) Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity..Instead,contact the office by phone or by traditional mail.if you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtD gsJ9a49YAgXJv... 10/l/2019 LLucie E® • R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry2019 C P,O.Box 230 Valrico,PL 33595 Phone 813.659.9197 Florida Board ofProfessional Engineers CertificateofAuthorization No.9813 Permitting 10 MEMO= Product Category Sub Category Manufacturer Product Name Exterior Swinging Therma Tru Corporation Fiber-Classic and Smooth-Star Exterior Door 118 Industrial Drive Composite Edge Opaque Fiberglass Single Door Doors Assemblies Edgerton,OH 43517 Inswingl0utswing Phone 419.298.1740 'Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants, I an yY�r�1don chmUeropy Corporation based on Rule Chapter No.61 G20-3, Method 1 D of the State of Floncta ppr Business&Professional Regulation, RW Building Consultants and Lyndon F.Schmidt, P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has-been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.2.2&R301.2.1.2.1. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-20468.1 require further engineering analysis by a licensed engineer or registered architect. 6. Fiber-Classic&Smooth-Star Door panels require the use of"J"part numbers and must be stained or painted within six months of installation 7. See drawing FL-20468.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed bV ETC 01-741-10700.0 TAS 202-94 ETC Laboratories Wendell W.Haney, P.E. ETC 01-741-10702.0 TAS 202-94 ETC Laboratories Wendell W.Haney, P.E. TEL 01461612 ASTM'E1,886-05, E1996-09, E330-02 Testing Evaluation Lab.,lnc. V.K.Wright TEL 01460145 ASTM E1886-02, E1996-021 E330-02 Testing Evaluation Lab.,lnc. Lyndon F.Schmidt, P.E. 2. Drawing No. Prepared by Signed&Sealed by No. FL-20468.1 RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt, P.E. 3. Calculations Prepared by Signed&Sealed bV Anchoring RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt, P.E. 4. Quality Assurance ��eAaeuoa47°°yap Certificate of Participation issued by National Accreditation and a°� ...... Management Management Institute, certifying that Therma Tru Corporation is ��® 1;•�1 G E N manufacturing products within a quality assurance program that complies No 43409 with IS0/IEC 17020 and Guide 53. '53 STATE OF e oS�o R A �\ �e Lyndon F.Schmidt,P.E. �®o®/�N�o Eo0®0 12/5/2017 FL PE No.43409 Sheet 1 of 1 "IHERMAITRU" DOORS 00 Fiber-Classic. & Smooth-Star. onmz o 2 7- 2E Za9m 0'a COMPOSITE EDGE FRAME WIDTH mAx 0.4 d E Lj OPAQUE FIBERGLASS SINGLE DOOR F37*75 2 INSWINGIOUTSWING "IMPACT" Q:O GENERAL NOTES C, Z i2 ( Z I This product has been evaluated and is in compliance with the 6th Edition 1:5 il "2017)Florida Bulding Code(FBC)structural requirements excludiing theHigh 8 CWIC(3 0 Velocity Hurricane Zone(WHZ). < E) -cr 2 Product anchors shall be as Wed and spaced as shown on details.Anchor =r embedment to base material shall be beyond wall dressing or stucco. w0 4 3. When used in areas requiring wind borne,debris protection this product complies with FBC Sections 16M.]2&R301 91.2 and does not require an M impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM El 996 and FBC Sections 1609.122&R301 9 1.2.1. E" 00 4 4- For 2x stud framing construction.anchoring of these units shall be the some as that shown for 2)c buck masonry construction. Z 0 .5- Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineeror registered architect. Z ?u 6. Fiber-Clossic:&Smooth-Star Door panels require the use of"J'Pad numbers and must be stained or pointed within six months of installation. t; TABLE OF CONTENTS Uj Z SHEET# I DESCRIPTION !;[ &General Notes a I I Typical Sevotions.Design Pressures 2 Door Panel Detals DESIGN PRESSURE(PSI) DESIGN PRESSURE(PSI) Z 3 Elevations 10 NZ a I Crass sections 2X 2 cl, LOCK INSWING OUTSWING 4 rlX,2 CONFIGURA77ON -081021 6 5 Horizontal&Vertical Cross Sections .24 HMDWARE DAw- I POSRIVF NEGATIVE 6 Ro�nzontol&Vertical Cross Sections(Direct to Mummy) POSTITIVE NEGATIVE s=L- N.T.S. 7 Vertical Cross Sections Uhresholdsl x Latch&Deadboll +67.0 -67.0 +67.0 -67.0 am in, JK M a Tuck&—Frome Anchoring -50.0 LFS 9 Hardware Deloffs x Mullipoint +50.0 -50.0 +50.0 MMW ria:- FL-20468.10 Components '"t t Bal of Materials 1 See Sheet 3 for Hardware Specifications sim OF_L1 R:\OlentsUherma Tru PERNANENT\A-Ftodda Product Approvais(FL-20468 W8DR TT FC SS impact-Composite\C-Drawing$\FL 20466(2017)-OJRRENT\FL-20468,I.3.dw0,2,1 79.25'MAX.DOOR PANEL HEIGHT ��sy O 4 y 0 t2 Z a N'' O O� O q W P P 02 � X N �2 � 0 03 13 A r I0 �M tNA 5 79.25'MAX.DOOR PANEL HEIGHT NN Z LlO Z r be O 1� m 13 a ISI ZO=3 13 Ip ci *0 CL,, C) �m 00 0 --� �— —-5.5° Q ° 79.06"MAX.DOOR PANEL HEIGHT N N 1 1 3 O Y.7Y" rn g 2 0 a 5.5' N N 03 0 \ 0.936' �0 0.99^ ZZ rlM m L 0 �o'� o, m I0 oa z �9 a -V=1 aa0 ro 7i rn Z :V NA z !7 ..mm z I Om C} r) L •J:,;°%"r`'`•' •:?' r''d'r `�11111r�1111ff11 tQ - 5' ,;�:r• }::.i:% y r:..':i`•,�...4.. t�`G S\iHu 11111 0,991,—h"--"�-I � No.43408 z Yato9tY? c PRODUCT: Doaumanta Prepared By: NATE OF •• f, 7HERMA—TRU Lyndon F. Schmidt i�i'�••' +1XOR50*.••G\ I FIBERGLASS DOOR P.E. No. 43409 kN tv !O 08 i8 REY. DOOR PANEL OPTION NOTE MT 11 y 11 15 17 RECESSED PANEL NOTATION JK PART OR ASSEMBLY: G%� //BUILDING CONSULTANTS, IVC�.I11t 1� m in'241 7 t7 17 LIPOATE TO 8th EO 2017 FBC JK eJ L' P,O, t?ox 230, Voirico, FL 33595 rn NO DATE By DOOR PANEL DETAILS vv Phone No.: 813.659.9197 REVISIONS FSPE C.A. No. 9813 10 2C 1 6 R.W.B..L....CONBtl4TA 1— _a_»__NTXA-Florida Product om_&-__,TTFCa Impact-_ «-_tniiffl.»eAmmaNT\F_ q,e a� w� 4 r �o 2k § « , \ \ § in� E2 E} 7 #C=D R ; a/mg ƒg [ & g7g0 =, mom o &� o ae8 % \ \ ID (D CD ( w {�: § k0 22 � \ — — a ;- §Ll El, k § E - \ \k � w , �'a©■x� � #m■ \ 10/09/1; \ - § PRODUCT: __, Prep_ By: �o % mm� z 9a+—u �_ __• _ 44� FIBERGLASS o R « 43409 ' . . . � § )\ 7\ s e mREV. DOOR PANE OPTION NOTE E ' A\ « \ kq\/ 71/RECESSED Jaz/� \ PART OR a_» � / CONSULTANTS/33595 \ / « m oI*E E ELEVATIONS _ 813.859.9197o201 .»_�,=_m_.� REVISIONS _Ec No. 9813 R:\OIents\Therma Tru PEP.MANENT\A-Florida Produd ApprovalskFL-20468 WBDRTT FC SS Impact-CompositeW-DrawingsVI.20468(2017)-QJRRMFL-20468.1-3.dwo,4.1 7- 0 :X C) -jF on A ttnn "I M Z' .0b IIIIII na O� z Z t 10 0 ar 1-114-MIN. p EMB.(TYP.) L7 0 00 £o icy n. Do OR 4. M so q 7- M C N..43409 Tk 10104/18 • PRODUCT Documents Prepared Byl STATE OF 'S THERMA—TRU Lyndon F. SchnnIdt C' FIBERGLASS DOOR P.E. No. 43409 RM DOOR PANEL OPTION NOTE MT f 0 01:: RECESSED PANEL NOTATION JK PART OR ASSEMBLY: BUILDING CONSU c- 2 — 17 17 UPDATE TO 6th ED (20177FBC JK '4a i 2'- 1 7 HORIZONTAL rJ& VERTICAL WP.O. Box 230, Voldco, FL 33595 NO DATE By CROSS SEC71ONS (2X BUCK) Phone No.: 813.659.9197 REVISIONS FSPE G.A. No. 9813 20-1 6-R.W.Su'lLODII—A CONMULTA—D INC. R:\Cllents\Therma Tru PERMANENT\A•Florida Product Appravals\FL-20468 WBDR TT FC SS Impact-Composite\C-Drawings\FL 20468(2017)-CURRENT\FL-20468.1.3Awg,5.1 A Z � M d . a• a s ozz —Y,�. n C N�o A U] y T O � N A Y Q0 D O ry C m o. O N o 70 o° C A 0 rn •. V 3 o Z M M v O • °p n A Z O r�l p. 0 A A N W N O r"= V y=o O N ?. N V pX S�In tr11 y n ° o ° m O z ```t\\til lllfffff' No.43408 10/09/18 4 PRODUCT: Document. Prepared By; —0, STATE OF r o THERMA—TRU Lyndon F. Schmidt •.,A(Cry;pl,.• FIBERGLASS DOOR P.E. No. 43409 a o z\ 3 10 08 18 REV. DOOR PANEL OPTION NOTE Mi y N 2 11 15 17 RECESSED PANEL NOTATION 1B01 PART OR ASSEMBLY: CDC���BUILDING co ly •D°io x in 1 7117117 UPDATE 70 6th ED 2017 FSC HORIZONTAL & VERTICAL "R�/(/ P•O. Box 23D, Valrico, FL. 33895 01 NO DATE CROSS SECTIONS (1X BUCK) Phone No.; 813.859.9197 REVISIONS FBPE C.A. No. 9813 ®20I S R.W.BUILDING ca N.0 LTANTII INC. R:\Cllents\Therma Tru PERMANENT\A-Florida Product Approvals\FL-20468 WSDR TT FC SS Impact-Composlte\C-Drawings\FL 20468(2017)-CURRENRFL-20468.1.3.dwg,6.1 p p 7 MAX. Oo SO MIN. 0 n 0 :10 F a� �n c m 3 rTt °• I .A, t7 Cr O�� IA N _gg m o 0 Iz 0sS m D m o 2,1 ' 4' n v to z 0 m v y MIN. -1 O Z z 2.25" 4 1.5"MAX. rit y (C:�Z . M is m� II rT1 t7 w N z 4„ l+ +Q MAX. G) O�qOZ ; y�v g T A p MIN. 0 n m °20 C7 m 0 H A N 3 n o a X. 33 �~ a S2 �3 O o . A IA IA \.§N A tAi °�Z m • n z a a s ff° 3 � o �A' n A 10 r � 4.• �o Q 1.5' 1111111 a to c�11 MIN. Q i L4,25- 6 1,5"MAX, p � 09 1009/1/ qq E PRODUCT: Decumente Prepared Oyl STATE .r r R THERMA-TRU Lyndon F. Sohmldt ��/'�•'• FlOR10�•,.''G,\� I FIBERGLASS DOOR P.E. No. 43409 //SS"••••••" `� I0, oN z 3 10 O6 1 6 REV. DOOR PANEL OPTION NOTE Mi /////�OfVA�I \� LJ 17 117 1UPDATETO6 NED 201 17 RECESSED PANEL NOTATION7FBC JK JK PART OR ASSEMBLY: CD BUILDING CONSULTANTS, f�1�. I-• m 'L fi 1 P.O. Box 230, VoIrleo, FL 33595 rn O NDATE BY HORIZO phone ND.: 813.659,9197 REVISIO SECTIONS TAL & VERTICAL(DIRECT TO MASONRY) FBPE C.A. No. 9613 ®2016 R.W.BUiIOINO DON94LTANTe IND.- S R:%Cfients\Therma Tru PEItMAt4EN7\A-Florida Product ApprovaiS\FL-20468 WBDR TT FC SS Impact-Composftc\C-Drawings\FL 2D468(2017)-CURRVMFL-20468.I-3.dw0,73 z 0 .14 Opp • 0 4P. -0,9 8� 0 QW �Q X 0 C., r) z 170 M v CD =r S M z rn r) P CD 0 M C r< n cr n 0 A 0 top :2 so PRODUCT; Ocaumento Prepared By: -,,o THERMA—TRU Lyndon No F.4340Sch Idt FIBERGLASS DOD P.C. FIB R 9M _3 WREV. DOOR PANEL OP77ON NOTE MT 2 RECESSED PANEL NOTATION J PART OR ASSEMBLY: I BUILDING CONSULTANTS,0,., 1 7 17 17 UPDATE To 6th ED (2017) FEC JW P.O. Bow 230, Valrico, FL 33595 rn NO, DATE BY VERTIC L CROSS RW RUVISIONS SECTIONS ?THRESHOLDS) Phone No.: 813.659,9197 FSPE C,A. No. 9813 0 2016 R.W.BUILDINO CON-NT.IND. R:\Giants\Therma Tru PERMANENT\A-Florida Product Appravai6\FL-20468 WSDR TT FC SS Impact-Composite\C-Drawings\FL 20468(2017)-CURRENT\FL-20468.L-3,dw0,8.1 Z �c 9 In 16"MAX. N.(IYP.) O —►1 t-+ .C.(TYP,( x z G� 13"MAX. 4"(TYPJ O.C.(TYP.) b i7° Z 3: V r o 4 Z 1S �<O O 14"MAX. - I 6"(7YP.)—►I }�— �=' O.C.(TYP.) �m X N No.43409 _ * 10109118: PRODUCT: Documante Prepared By: • $TATE OF THERMA—TRU Lyndon F. Schmidt ��i� •.t20R19�.•° FIBERGLASS DOOR P.E. No. 43409 �CD O o z 3 10/08/15 REV? DOOR PANEL OPTION NOTE M7 2 11 15 17 RECESSED PANEL NOTATION JK PART OR ASSEMBLY: GDq�jBUILDING CONSULTANTS, IGS. jJ iq\ 1 7 17 17 UPDATE TO 8th ED 2017 F&C JK BUCK & FRAME ANCWQRING ,JN P'O. Box 230, Vairico, FL 33595 I cn 0 DATE BY Phone No.: 813.659.9197 REVISi NS FBPE C.A. No. 9813 2D 7 e q.W,aurLalNo Oa N9 UI.TANTa INa. R:\C1entsl'1herma Tru PERMANENT),-Florida PmduCt ApprovaisiFL-20468 WSDR TT FC SS Impact-Composite\C-prawingslFl 20468(2017)-CURRENRFL-20468.1-3.dwg,9.1 Q _ n� r��r[}p'111 X + Ua 05 c G Of� w to O� C C A H Z„i C C Z.-1 () QDo Tr 4Nit ( n n CL O 2 -t O n 'y3 or C3 o O m p ❑ O ❑ CO fn *t O �rn 00 CD o a 0 �o Q r CL y 0 AA - o rn w Q Q 44.88"(t 1.5')—+I o N <O M m a N m 29.25"(TYP.) 11.25"FROM TOP BOOK DOOR OF JAMB 29.75"(TYP.)�t-11.12S'FROMTOP m U1/HYBRIDDOOR OFJAMB z t7 m b r•- C) m Im (--25.37' 30.31"--) 1-•-- --45.25'(J:I.S'( =1 C C z%-i {C� C �c O Pnc 7n O 9c r 7C ae c 8E Lo `t111111lt����' rn n$ o `� o ��� F,SCN Q L `��� •'V,GF118� r a �t F. No,43409 10/09/18 S? � � � PRODUCT: Oocumente Prepored Hyt � •` F THERMA—TRU Lyndon F. Schmidt rrjr'jS� ' FLDgTDI.• \ lto O 'd z\ 3 10 OB 18 REV. DOOR PANEL OPTION NOTE MT F78ERGLASS DOOR P.E. No. 430.08 r�is�s/pFVAI. 2 tt t5 17 RECESSED PANEL NOTAT70N JK PART OR ASSEMBLY: L7� BUILDING OONSULTAtJTS, qc X y\ t' 7 17 17 UPDATE TO 6th ED 2017 FOC JK J(i P.O. Bolt 230, VcHco. FL 33595 �+ m NO DATE gY HARDWARE DETAILS Phona No.: 813,659,9197 REVISIONS FBPE C,A, No. 9813 2016 R.W.tlult.OtNa tiaNBUi.TANTa INC. R;\0lent5\Themla Tru PERMANENTiA-Florida Product Appmvals\FL-20468 W8DR TT PC SS Impact-ComposlteiiC-DraygniisliFf.20468(2017)-CURRENlliFL-20460.1-1dwii,10.1 1.35" nwi t-f, E F 0 0 0 CL Ln In Ln > 0 CD 1 14 01082, to n 3 > F I I I 0 0.911, i.or 0 X. :3 0.69' 3 ig 0,75' I III/,, ac. No.43409 PRODUCT: Documents Prapored Dy: STATE OF —TRU Lyndon F. Schmidt Jo No Z THERMA FIBERGLASS DOOR P.E. No. 43409 'Co 3 REV. DOOR PANEL OPTION NOTE MT R, BUILDING U III( III%% TATION JK PART 2 RECESSED PANEL NO OR ASSEMBLY: DONS E 42— P.O. Box 230, Voirloo, FL 33596 rn 1 7 17 17 UPDATE TO 6th ED (20171 F13C JK NO 0 Wy DATE -- COMPONENTS Phone No.: 813.859.9197 REVISIONS FBPE C.A. No. 9813 2016 R.W.BUILDINO CONBU4TANTS INC, `��NlrUrrrrq BILL OF MATERIALS BILL OF MATERIALS ITEM# DESCRIPTION MATERIAL REM# DESCRIPTION MATERIAL A 1X BUCK(SG2-1 ¢:Q— " ( ) WOOD 25 #8 x /7'PFH WOOD SCREW STEEL B 2X BUCK SG>=0.42 = =� z �F'?`p=LL m ( ) WOOD 26 #8 x 5/8"PFH WOOD SCREW STEEL o- C 1/4"MAX.SHIM SPACE - 12 27 LATCH STRIKE PLATE STEEL ''- _ __. ,g.` 00 D 114'X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 28 DEADBOLT STRIKE PLATE(STANDARD) STEELLo MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI 28A DEADBOLT SUB STRIKE PLATE STEEL I1Ilt%t` z o:2 o E 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 28B DEADBOLT STRIKE PLATE(SECURITY) STEEL `� 0,N•.z G 3/16"X 3-1/4 m ?m o J 1/4"X 33/4"PFH ELCO OR Ti1N CONCRETE SCREW STEEL 30 LATCH 8,DEADBOLT STRIKE PLATE(TONGUE SYSTEM) ALUM/COMP ^ n w" 5 d t m L #10 X 2-1/2'PFH WOOD SCREW(1.15"MIN-EMBEDMENT) STEEL 31 MULTIPOINT STRIKE PLATE(TONGUE SYSTEM) ALUM/COMP s 4 a \a M 3/16"X 2-1/4"ITW CONCRETE SCREW .STEEL 32 INSWING THRESHOLD ALUM/COMP E N 3116'X 2 3/4"ff W CONCRETE SCREW STEEL 33 INSWING THRESHOLD ALUM/COMP o �a € 1 JAMB(FINGER JOINT PINE) WOOD 34 INSWING THRESHOLD ALUM/COMP 6 WEATHERSTRIP(MEDIUM REACH) FOAM 35 INSWING THRESHOLD ALUM/COMP 7 WEATHERSTRIP(LONG REACH) FOAM 36- INSWING THRESHOLD ALUM/COMP 8 SWEEP VINYL 37 INSWING THRESHOLD ALUM/COMP �o s 9 SWEEP(USE w/MODERATE CLIMATE THRESHOLD) VINYL 38 INSWING THRESHOLD ALUM/COMP �( 10 SWEEP(USE w/PUBLIC ACCESS THRESHOLD) VINYL 39 INSWING THRESHOLD ALUM/COMP ms m 15 PUBLIC ACCESS THRESHOLD ALUM 40 DOOR PANEL(BOOK) 3 16 OUTSWING THRESHOLD ALUM/COMP 41 DOOR PANEL(HYBRID) _ m 17 OUTSWING THRESHOLD ALUM/COMP 42 DOOR PANEL(Ul) 18 OUTSWING THRESHOLD ALUM/COMP a n< g 22 #8 x 3/4"PFH WOOD SCREW STEEL E 8 23 T#10 x 3/4"PFH WOOD SCREW STEEL m 24 #10x 1"PFH WOOD SCREW STEEL v O � lt' 20� aFo a�.w 3 CONCRETE ANCHOR NOTES: w?w p 1.Concrete anchor locations at the comers may be adjusted to maintain the min. z t edge distance to mortarjoints. n$ 2 Concrete anchorlocations noted as MAX.ON CENTER"must be adjusted to 0 0 — maintain the min-edge distance to mortar joints,additional concrete anchors m a may be required to ensure the'MAX ON CENTER"dimension are not exceeded.. w¢ < 3.Concrete anchor table: �� 6 M{N CLE/ANCE MIN �LEARAN�� d -ANCHOR ANCHOR AQIM TO MASONRY 70,ADJACENT.'' ? TYPE $RE o ..... ..........:................ ::...::..:: ITW LL TAPCON® 1/4" 1-1/4" 2" 4" n N o 0 Z o ELCO ° ULTRACON 1/4" 1-1/4" 1" 4" DATE 08/02/16 n N.T.S. z TATrw 3/16" 1-1/4" AS SHOWN 1-1/2" Mr.W. JK m r a+x.er: LFS 3 WOOD SCREW INSTALLATION NOTES: o WWW uo- ¢ 1.Maintain a minimum 5/8"edge distance,I"end distance.8 I"o.c.spacing of }'x_20468.1 wood screws to prevent the splitting of wood. a sir 11 or 11