Loading...
HomeMy WebLinkAboutProduct Approval db FLt',Phan oFacturedBuildingProgram De ar'tnentofBUM 2601 Blair Stone.Road YJ �'e_fofessional 4 ulatsion Tallahassee;Florida 32399 0772 Phone:850.407.1924-Fax 850.414.8436 Halsey Beshears, Secretary Ron DeSantis, Govemor August 07, 2019 Alex Martens Superior Sheds,Inc. 2323 S.Volusia Ave Orange City, FL 32763 RE: Manufacturer Certification,ID MFT-113; Expiration Date: August 07,2022 Dear Alex Martens It is my pleasure to inform you that Superior Sheds,Inc., located at 2323 S.Volusia Ave,Orange City, FL 32763, has been approved under the Manufactured Buildings Program,as provided for under Chapter 553, Part I, Florida Statutes,to manufacture Storage Sheds, Manufactured Buildings for installation in Florida. Construction or modification on a manufactured building cannot begin until the Third Party Agency has approved the plans in accordance with the current Florida Building Code. Your Third Party Agency is a contractor for the Department and has statutory authority and responsibilities that must be met to maintain approved status.You may expect and demand quality plans review and inspections. Each Code change will make your plans obsolete until they have been reviewed, approved and indicated (on the cover page of the plans]for compliance with the Code by your Third Party i.gency for plans review. Please ensure that your plans are in compliance and are properly posted on our website.All site-related installation issues are subject to the local authority having jurisdiction. The Department's contractor will make unannounced monitoring visits at least once each year. You must grant complete access to your manufacturing facility and records to remain in compliance with the rules and regulations of this program. Your certification is approved for three years from this date.You will receive a renewal notice by Email generated by the BCIS (www.floridabuildinci.org)for online renewal. If you have questions you may contact Robert Lorenzo at 850-717-1835 or our FAX at 850-414-8436. Please visit our website at www.floridabuildinci.org to see valuable information on the Florida Manufactured Buildings Program.A copy of this letter must accompany applications for local building permits. Sincerely, Robert Lorenzo Manufactured Buildings Program cc:Top Line Engineering, LLC ................................... _ t SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS ' PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. �"'1✓ i 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE i BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). --------- ---=i,� 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)4"X44" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS CODE INFORMATION PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). CODE VERSION FBC 2017 6th Edition,ASCE-7 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS MANUFACTURER SUPERIOR SHEDS REMOVED. BUILDING TYPE MANUFACTURED LDING RESIDENTIAL LAWN(STORAGE 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO CONSTRUCTION TYPE V-B FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS ALLOWABLE NUMBER OF STORIES 1 BASIC WIND SPEED Vr-200mph 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE EXPOSURE D AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE ENCLOSURE ENCLOSED HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. ! 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). INTERNAL PRESSURE COEFFICIENT +/—0.18 LOCATE ANCHORS PER TABLE 4A OR 4B. IMPORTANCE FACTOR 1.15 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE ROOF DEAD LOAD 1OPSF (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH ROOF LIVE LOAD 2OPSF OR 300Ibe L AUTY THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED FLOOR DEAD LOAD BPSF IX PORTIONS OF SHEDS ON LEVELING BLOCKS. FLOOR LIVE LOAD STD.75PSF- 125PSF OPT. AUTM TABLE 4A IX 30" AUGER ANCHOR SPACING — SINGLE WIDE "R"RATING of WALLS, FLOOR. ROOF MODULES PER BUILDING I {{ SHED WIDTH LW I UPLIFT (PLF) END ANCHOR" MAX. INTERIOR SPACING••• HURRICANE PROTECTION USAGE NO XITM 13'-B" 7.00 243 0'-0"TO 3'-O" 10'-0" HURRICANE SHELTER USAGE NO SQUARE FOOTAGE LESS THAN 720 SOFT. 11'-8" 6.00 208 0'-0"TO 3'-0" 10'-0" :ED REVISIONS 10'-0" 5.00 174 0'-0"TO S-O" 10'-0" REV DESCRIPTON DATE BY 1 2017 FI3C 11/12/17 MTB 8'—O" 4.00 138 O'-0"TO 3'-0" 1 O'—O" 2 GROUND ANCHOR 6"AF.G MAX.,ANCHOR EXTENSION 5/26/18 MTB 6'-0" 3.00 104 0'-0"TO 3'-0" 10'-0" I TABLE B 30" AUGER ANCHOR SPACING — DOUBLE WIDE SHED WIDTH LW* UPLIFT (PLF) END ANCHOR-- MAX. INTERIOR SPACING"" U) Drawn By: MTB 20'-0" 1 10.00 400 0'-0"TO 3'-0" 5'-0" C:) Date: • LOAD WIDTH OF UPLIFT ON RUNNER LLJ 4/26/16 :.LOAD FROM END WALL OF AUGER ANCHOR = Scale: MAXIMUM SPACING BETWEEN ANCHORS (n N/A NOTES oeel 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. W ALL 2. ALL MEASUREMENTS ARE CENTER-TO-CENTER. C) GENERAL NOTES 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. 1. FOUNDATION PLANS ARE NOT PART OF THIS ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" PLAN SET AND ARE GOVERNED BY LOCAL BETWEEN ANCHORS.. JURISDICTION. I 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN 2. THIS BUILDING IS EXEMPT FROM THE FBC EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE w ENERGY CONSERVATION CODE PER SECTION TO THE SIDE AS POSSIBLE. J 1015.22. m 3. REFER TO TIE-DOWN DETAILS FOR PROPER INSTALLATION REQUIREMENTS TO MEET CODE O I LJJ J NOTCH OR COUNTERSINK BOLT THRU 2"x4" BOTTOM PLATE (/ 2"x4" BOTTOM PLATE NAILED I - 1/2"x5" (400 LB.) CONCRETE TO 2"x6" P.T. BASE LL_I N. WEDGE ANCHOR INTO SLAB ---- MIN. QTHRU 2"x4" P.T. BOTTOM PLATE(SEE TABLE 1 FOR SPACING) 1d------- �fj4" AB BY OTHERS THROUGH CONCRETE SLAB BY OTHERS THROUGH AND JURISDICTION LOCAL CODES AND JURISDICTION o_ 6/1 / 18 SHED WITH 'NO FLOOR' OPTION Q� ANCHORED TO CONCRETE _] J Matthew T. Baldwin P.E. QFlorida License #64608 W� z Sheet: AD-1 OF 1 H — SETUP AND INSTALLATION OF SINGLE WIDE SHED J. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED 30" AUGER ANCHOR THRU THE 2"x4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL (4,900LB) 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. INSTALLED PER MANUFACTURER'S 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO INSTRUCTIONS. EYELET AT FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. MAXIMUM OF 6" ABOVE GRADE. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG' FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. TABLE 1 TABLE 2 TABLE 3A ANCHORING TO CONCRETE SKID RUNNER SPACING* PAD TYPES SHED WIDTH UPLIFT (PLF) ANCHOR SPACING SHED WIDTH X1 X2 X3 TYPE PAD DIMENSIONS MAX. LOAD* MATERIAL 20'-0" 400 3'-6" 13'-8" 1'-1W 1-10l" 1'-104" I 2"x8"x16" 1778LBS CONCRETE BLOCK CEMENT AND SAND 13'-8" 280 3'-6" 11'-8" 2'-8" 6'-4" — II 4"x8"x16" 3500LBS CONCRETE BLOCK CEMENT AND SAND 11'-8" 240 3'-6" 10'-0" 1'-7" 6'-10" — III 16"x16" 3950LBS ABS PLASTIC PADS 10'-0" 200 3'-6" 8'-0" 0'-9" 6'-6" — IV 8"x8"x16" 1900LBS CONCRETE BLOCK CEMENT AND SAND 8'-0" 160 3'-6" 6'-0" O'-10" 51" — * BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPIC .NOTES 6'-0" 120 3'-6" -VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"x4" 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STA SKIDS ONLY. 13'-8" WIDE SHEDS HAVE (4) SETS OF SKIDS. ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 1 V-8"AND 13'—B" WIDE SHEDS ONL TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW*(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER INTERIOR SIDE RUNNER PAD TYPE PAD PAD TYPE 13'-8" SW/DW 4.15/332 0"TO 5" 6'-0" 1936LB I, II, III, OR IV 1879LB I, II, III, OR IV 11'-8" SW/DW 6.00/480 0"TO 6" 6'-0" 2558LB I, II, III, OR IV 2558LB I, II, III, OR IV 10'-0" SW/DW 5.00/400 0"TO 6" 6'—O" 2400LB I, II, III, OR IV 2400LB I, II, III, OR IV 8'-0" SW 4.00/320 0"TO 6" 6'-0" 2029LB I, II, III, OR IV 2133LB I, II, III, OR IV 6'-0" SW 3.00/240 0"TO 6" 6'-0" 1658LB I, II, III, OR IV 1866LB I, II, III, OR IV • LOAD WIDTH OF UPLIFT ON RUNNER NOTES 1. PAD SPACING IS END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. 2"x2" GALVANIZED WASHER 2"x2" GALVANIZED WASHER WITH 1/2" NUT 1/2"THREADED ROD WITH 1/2" NUT OPTIONAL FOR "HIGH SET" 1/2" THREADED ROD EYES BOLTED TOGETHER WITH 1/2"x2" OPTIONAL FOR "HIGH SET" BOLT & NUT WITH (2)2"x2" GALVANIZED 1/2" COUPLER 1/2" COUPLER _ WASHERS (2.0001-6 SHEAR CAPACITY) 1/2"02" FORGED EYEBOLT mGRADE a. EYES BOLTED TOGETHER WITH 1/2"x2" TYPE I, II, III, OR IV PAD WITH BOLT& NUT WITH (2)2"x2" GALVANIZED N BLOCKING AS REQUIRED (SEE TABLE 3). 1/2"x3" (400 LB.) SIMPSON A-24 CONCRETE `. WASHERS (2.000LB SHEAR CAPACITY) CONCRETE WEDGE ANCHOR CUP OR EQUAL LOCAL CODE 30" EARTH AUGER ANCHOR (SEE TABLE 1 FOR SPACING) (SEE TABLE 4 FOR SPACING) SHED WITH SKID SHED WITH SKID TO PAD OR BLOCKING ANCHORED TO CONCRETE TIE-DOWN DETAILS 2018-12-20TOP LINE ENGINEERING APPROVAL PLAN#S$-& End Wall Header Schedule 180C 180 C Side � 4 -- w�wc�anuv xoCE slue sp, Fas4rcn M.Inp vb o. .ter.nal uan.a.l -e'Wa. fAr 6 a-]'.atat'nats a eealvtnpi bn..et e.Nmt aer. I 1 I .>tr.z.r .,ea to u• a e e-r.a+m•.aa a — �''I'"�= - aw-x.meolixx+wm,.a.n.am.wpm aw r.:aau,wmw..pam.y.um nab no.o�wr w.nN.a.Im wau,evb I od nd.,+,aln.:.e b.malnaaa,a<lona. '� i 4s..nm.raeves mranmul.Nrw.,la z-z1r o,r,r P.r. i '�.,.me a .Tn.fineacm n.ul.aeemuw lop pam mwub.mblm.�un<a.e.,o�n CODE I F➢P no maw.a.w e.w.vu.imun.Pa..W.a Two, YI mPems ... Nu.rrn.v C- I "�">x aamcmN me Y •..•muss E'• a,®,�n csnti � �]N'as utv d ira-.® b rw 4V.K9C M1no v s,am HYOROVENT DETAIL ID W I WINDOWS FND WALLS WINDOWS& Dm 'rPUS 414'W/2•.4• (OPNONALT &DOORS DOOR fi'WIDE OR LESS G.F.I. -IB+ UTUEr N D O +-"`RnsC1"a wrier reoe uc aaic ��LM1'w.Y� �ubname-b,o _ I oEv4N Pxmwcs SOURCE L O Mac ma's°'° v nmc ROOF FRAMING PLAN — WIRING DIAGRAM aw eaoo.os u.a.a em a.mic aoou axs-M2q�, 0 A I m. "' .. REVlsorls c • MCRMON 611E er z I z Iz/Iz/n ' I Ma O.-•'ok N/A Li I Z 55-B-1 WC va a a. R FW- v m �, N=� STANDARD WALL DEFAI pia,m � a� wnR OCcai°,1010' s9wm 0 ELEVATION CROSS-SECNON END ELEVATION ma . .n., bwxuau.enRov _ L•a Z \\ // a < _ i�•; STATE wm I I TMvm ,a�n,cw I //�--• �-L O R I O p:i`��`� it /lllll 11 END ELEVATION ENDI ELEVATION na•+a mm Z FLOOR FRAMING PLAN In 51R1: SSB-1 OF I I _ I t I l I 1 f