HomeMy WebLinkAboutDesign Load Compliance I
S'T'ORM License a chobee Blvd,
4047 Okeechobee Blvd,Ste 106,
West Palm Beach, 33409
Phone(561)229-00404 8SMART
of Southeast Florida ��stormsmartsE.com
Property Information Building Information
Owner: Voss Milloway Wind Zone: 160 MPH.
Address: 7979 Plantation Lakes Exposure Category: C
Port Saint Lucie,FL 34986 Minimum Building Dimension: 9 ft.
Mean Roof Height: 18 ft.
Risk Category: II
I
Design Pressure Calculations.
Opening Location Device Device Device Max Positive Max Negative
Number L Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
2 Int 110.25 137 11.5 29.5 -32.4
i
3 Int 222.75 131.5 11 28.0 -30.9
4 End 152.25 131.5 11 28.8 -34.7
5 End 107.25 140 12 29.5 -36.0
i
Ii
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.