FL# FL10124-1120
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
(800)766-3411
mstieh@gaf,com
Authorized Signature Robert Nieminen
Ireith@nemoetc.com
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(800)766-3411
TechnicalQuestionsGAF@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/18/2021
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10124 R20 COI 2017 01 COI Nieminen,pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
TAS 107 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Ihfp:/Iwww.floddabuilding.org/pr/pr app dti.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3BoOyLwXhMdCmfpylEOIVYCA*/o3d*/o3d 1/2
2/4l2019 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 09/20/2017
Date Validated 09/27/2017
Date Pending FBC Approval 09/28/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and hip/ridge
asphalt shingles
Limlts.of Use Instillation Instructions
Approved for use in HVHZ:No FL10124 R26 iI 2017 09 FINAL ER GAF Asphalt
Approved for use outside HVHZ:Yes 5hinales FL10124-R20.pgf
Impact Resistant:N/A Verified By:Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section S. Evaluation Reports
FL10124 R26 AE 2017 09 FINAL ER GAF Asphalt
Shingles FL10124-R20.pd
Created by Independent Third Party:Yes
back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL.32399 Phone:850-487-1824
The State of Florida Is an WEED employer.-ggayrlght 2007-2013 State aF Find&.::PrivaN Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records..If you do not want your.e-mall address released in respohse to a public-records.request,,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.!Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,FS.'must provide the Department with an email address If they have one.The emalis
provided may be used for official communication with the licensee:However email addresses are public record.if you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to they public.To determine If you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Aaeeptr.
Credit Card
Safe
http://www.floridabuilding.org/pr/pr_app_ tl.aspx?param=wGEVXQwtDquracBevcbdMONZD6Zesy3BoOyLwXhMdCmfpy[EOlvyCA%3d%3d 212
I
EXTERIOR RESEARCH.&DESIGN,LLC.
f' Certificate of Authorization#9503
353 CHRISTIAN STREET,UNIT#13
! TRINITY ERD OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-1122
1 Campus Drive FL10124-1120
Parsippany,NJ 07054 Date of Issuance:01/03/2008
(800)766-3411 Revision 22:09/20/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida:The documentation submitted has been reviewed by Robert Nieminen',
P.E. for use of the product under the Florida Building Code and Florida-Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6`h Edition (2017) Florida Building Code.
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
copy of this entire Evaluation R-r.GFt4MH=be==pmvided4o4he=Wer-by=the-rnanufa-.-.
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M.Nieminen,P.E.
�k,zsrtsrrsss The facsimile seal appearing was authorized by Robert Nleminen,
Florida Registration No.59266,Florida DC4 ANE1983 PZ on 09120/2017.This does not serve as an electionially slgned
document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen; P.E:does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
i
4
TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated:compliance with the
following sections of the eh Edition (2017) Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4/1507.1.1, Physical Properties ASTM D1970 2015
R905.2.3/R905.1.1
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507:2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Entity Examination Reference Date
GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant iR 01/13/2012
PRI(TST 5878) Physical Properties GAF-025-62-01 03/27/2002
PRI(TST-5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Physical Properties GAF-324-01-01 - 12/01/2011
PRI(TST 5878) Wind Dnven:Rain GAF-407-02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2060
UL(TST 1740) TAS 107 94NK9632 03/29/2000
02 02 2001 --
UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001
UL(TST 1740) ASTM D3161 01NK37122 12/18/2001
UL(TST 1740) A5TM D3462 01NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM 63462 03N1(26444. 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1746) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 OSNK27924 02/10/2006
UL(TST 1740) ASTM D3161 OSNK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) - ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161,D7158,D3462 .08CA06100 03/13/2008
Exterior Research and Design,I.I.C. Evaluation Report 03S06.01.08-R22
CerdJkote clAuthorkatlon p9503 6°f EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1120.
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 2 of 6
TRINITY'ERD
Entity Examination Reference Date
UL(TST 1740) ASTM D3161,D3462 07CAS5908 04/01/2008
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2069
UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009
U L(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA35554 03/05/2010
.UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010
U L(TST 1740) ASTM D3462 10CA07264 05/27/2010
UL(TST 1740) ASTM D3462 10CA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK22070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 SOCA53934 03/3112011
UL(TST 1740) ASTM 03161,D7158,D3462 11CA48924 10/22/1011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2012
,UL,I.I.C.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 62/26/2013
UL,I.I.C.(TST 9628) ASTM D3161 13CA32332 06/19/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015
UL,I.I.C.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 30/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 10/20/2016
UL,LLC.(QUA 9625) Quality.Control Inspection Report,R21,Tuscaloosa,AL 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,1121,Michigan Cty,IN 11/01/2016
UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Shaffer,CA 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016
---
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 10/21/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,,Dallas,TX 11/04/2016
';UL,LLC.(QUA 9615) Quality Control Inspection Report,R21,Ennis,TX 11/03/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 11/01/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
. 4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot®, Camelot® 11, Fortitude""", Glenwood'", Grand Canyon®, Grand Sequoia*, Grand Sequoia® IR,
Grand Sequoia® ArmorShieldTM, Monaco®, Sienna®, Timberline® American Harvest®, Timberline®
ArmorShieldTM II,Timberline®Natural Shadow®,Timberline HD®,Timberline®Cool Series®,Timberline Ultra
HD®and Woodland®are fiberglass reinforced,laminated asphalt roof shingles.
'4.1.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge®
ArmorShield"'" Ridge Cap Shingles and Timbertex®Premium Ridge Cap Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
Exterior Research and Design,I.I.C. Evaluation Report MS06.01.08-R22
Certificate of Authorization#9S03 6""EDITION 12017)FBC NON-HVHZ EVALUATION FL10124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 3 of 6
I
I
] TRINITY!ERD
4.3 Accessory Starter Strips:
.4.3.1 Pro-Start®Eave/Rake Starter Strip Shingles and WeatherBlocker"'Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen starter strip,nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-
inch or less.
4.3.3 StarterMatch" Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and
Grand Sequoia® series asphalt shingles. StarterMatch"A are installed as the second starter for Grand
Canyon°and Grand Sequoia®series installations.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Unity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classiflcation:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D715k Class H,indicating the shingles are acceptable for
use in all wind zones Up to Vasd=150 mph(V„n=194 mph).. Refer to Section 6 for installation requirements
to meet this wind rating.-
5.4.2 The GAF hip•&ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and 11905.2.6.1 to ASTM D3161,Class F, indicating the shingles are acceptable for use in ail wind zones.up
to Vasa=150 mph(V„n=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies only to exposure category B or C,as defined in FBC 1609.4.3,and a
heigniTt Vynau Tee or less. calculations by'a. qualifieddesign professional are required for
condition's outside these limitations. Contact the shingle manufacturer for data specific to each shingle. .
'S.5 Ali products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
_ 6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
�6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel&Stick Starter Roll shall comply with the.GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of as shingles.shall comply with the GAF current published instructions, using minimum four
(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions:
➢ Camelot, Camelot 11, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield,
and Woodland require minimum five(5)nails per shingle.
➢ Slateline requires minimum six(6)nails per shingle.
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6
or R90S.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the GAF for details.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.09-RZ2
CertiJfcate ofAuthoHzatlon#9503. 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1120
-GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 4 of 6
TRINITY ERD
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and
Seal-A-Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with
a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter
beads of Henkel"Loctite Pl.S30 Roof&Flashing Sealant".
11:5' 4ellante
ealant
1• (292mm) 1'
(25 mm) (25 rnnduit d'dtancheitd
�. 12'
(305 mm)
Nail
Clavo
6 5/8'-7 5/8' Clouer
(168-194 mm)
12'
(305 mm) -
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions
with a minimum two.(2),nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NPi
Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
tt 5 Sealant •
1' (2°2 rn-rl 1 Sellarrl0
(2S inml {?5 im r-rd6it d'dtarch6 t6
F1
. t
Nai
(305 Trn j
9
1229 mr•Y,
12'
{305 mT1
6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1S07.2.6 or
R905.2.5. Staples are not permitted.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122
i C&V lcate ofAuthorkallon#9503 6"EDITION(2017)FBC NON-HVH2 EVALUATION FL10124-1120
j GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 5 of 6
I
t ,
TRINITY ERD
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/11905.2.6.1.-
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
'this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(847)664-3281
END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 01SO6.01.08&R22
Gertipcote ofAuthorkation A9503 6'EDITION(2017)FOC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 6 of 6