Loading...
HomeMy WebLinkAboutProduct Approval 214/2019 Florida Building Code Online BCIS Home i Log In User Registration Hof Topic I Submit Surcharge Stats&Facts Publications Contact Us i SCIS Site Map 1 Unks 1, Search look d u Product Approval ;n USER:Public User, r Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL10124-1120 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany,NJ 07054 (800)766-3411 mstieh@gaf,com Authorized Signature Robert Nieminen Ireith@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany,NJ 07054 (800)766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/18/2021 Validated By John W.Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10124 R20 COI 2017 01 COI Nieminen,pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 TAS 107 1995 Equivalence of Product Standards Certified By Sections from the Code Ihfp:/Iwww.floddabuilding.org/pr/pr app dti.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3BoOyLwXhMdCmfpylEOIVYCA*/o3d*/o3d 1/2 2/4l2019 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 09/20/2017 Date Validated 09/27/2017 Date Pending FBC Approval 09/28/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and hip/ridge asphalt shingles Limlts.of Use Instillation Instructions Approved for use in HVHZ:No FL10124 R26 iI 2017 09 FINAL ER GAF Asphalt Approved for use outside HVHZ:Yes 5hinales FL10124-R20.pgf Impact Resistant:N/A Verified By:Robert Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER,Section S. Evaluation Reports FL10124 R26 AE 2017 09 FINAL ER GAF Asphalt Shingles FL10124-R20.pd Created by Independent Third Party:Yes back Next Contact Us::2601 Blair Stone Road,Tallahassee FL.32399 Phone:850-487-1824 The State of Florida Is an WEED employer.-ggayrlght 2007-2013 State aF Find&.::PrivaN Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records..If you do not want your.e-mall address released in respohse to a public-records.request,,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.!Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,FS.'must provide the Department with an email address If they have one.The emalis provided may be used for official communication with the licensee:However email addresses are public record.if you do not wish to supply a personal address,please provide the Department with an email address which can be made available to they public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Aaeeptr. Credit Card Safe http://www.floridabuilding.org/pr/pr_app_ tl.aspx?param=wGEVXQwtDquracBevcbdMONZD6Zesy3BoOyLwXhMdCmfpy[EOlvyCA%3d%3d 212 I EXTERIOR RESEARCH.&DESIGN,LLC. f' Certificate of Authorization#9503 353 CHRISTIAN STREET,UNIT#13 ! TRINITY ERD OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT GAF Evaluation Report 01506.01.08-1122 1 Campus Drive FL10124-1120 Parsippany,NJ 07054 Date of Issuance:01/03/2008 (800)766-3411 Revision 22:09/20/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida:The documentation submitted has been reviewed by Robert Nieminen', P.E. for use of the product under the Florida Building Code and Florida-Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6`h Edition (2017) Florida Building Code. sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. copy of this entire Evaluation R-r.GFt4MH=be==pmvided4o4he=Wer-by=the-rnanufa-.-. its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M.Nieminen,P.E. �k,zsrtsrrsss The facsimile seal appearing was authorized by Robert Nleminen, Florida Registration No.59266,Florida DC4 ANE1983 PZ on 09120/2017.This does not serve as an electionially slgned document. CERTIFICATION OF INDEPENDENCE: 1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen; P.E:does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. i 4 TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated:compliance with the following sections of the eh Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4/1507.1.1, Physical Properties ASTM D1970 2015 R905.2.3/R905.1.1 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507:2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entity Examination Reference Date GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant iR 01/13/2012 PRI(TST 5878) Physical Properties GAF-025-62-01 03/27/2002 PRI(TST-5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI(TST 5878) Physical Properties GAF-324-01-01 - 12/01/2011 PRI(TST 5878) Wind Dnven:Rain GAF-407-02-01 01/21/2013 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2060 UL(TST 1740) TAS 107 94NK9632 03/29/2000 02 02 2001 -- UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001 UL(TST 1740) ASTM D3161 01NK37122 12/18/2001 UL(TST 1740) A5TM D3462 01NK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM 63462 03N1(26444. 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1746) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 OSNK27924 02/10/2006 UL(TST 1740) ASTM D3161 OSNK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL(TST 1740) - ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 .08CA06100 03/13/2008 Exterior Research and Design,I.I.C. Evaluation Report 03S06.01.08-R22 CerdJkote clAuthorkatlon p9503 6°f EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1120. GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 2 of 6 TRINITY'ERD Entity Examination Reference Date UL(TST 1740) ASTM D3161,D3462 07CAS5908 04/01/2008 UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2069 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 U L(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 IOCA35554 03/05/2010 .UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010 U L(TST 1740) ASTM D3462 10CA07264 05/27/2010 UL(TST 1740) ASTM D3462 10CA11953 10/29/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IONK11951 10/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK22070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 SOCA53934 03/3112011 UL(TST 1740) ASTM 03161,D7158,D3462 11CA48924 10/22/1011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2012 ,UL,I.I.C.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 62/26/2013 UL,I.I.C.(TST 9628) ASTM D3161 13CA32332 06/19/2013 UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015 UL,I.I.C.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 30/25/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 10/20/2016 UL,LLC.(QUA 9625) Quality.Control Inspection Report,R21,Tuscaloosa,AL 11/11/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,1121,Michigan Cty,IN 11/01/2016 UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Shaffer,CA 11/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016 --- UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 10/25/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 10/21/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,,Dallas,TX 11/04/2016 ';UL,LLC.(QUA 9615) Quality Control Inspection Report,R21,Ennis,TX 11/03/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 11/01/2016 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: . 4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot®, Camelot® 11, Fortitude""", Glenwood'", Grand Canyon®, Grand Sequoia*, Grand Sequoia® IR, Grand Sequoia® ArmorShieldTM, Monaco®, Sienna®, Timberline® American Harvest®, Timberline® ArmorShieldTM II,Timberline®Natural Shadow®,Timberline HD®,Timberline®Cool Series®,Timberline Ultra HD®and Woodland®are fiberglass reinforced,laminated asphalt roof shingles. '4.1.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip&Ridge Shingles: 4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge® ArmorShield"'" Ridge Cap Shingles and Timbertex®Premium Ridge Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. Exterior Research and Design,I.I.C. Evaluation Report MS06.01.08-R22 Certificate of Authorization#9S03 6""EDITION 12017)FBC NON-HVHZ EVALUATION FL10124-1120 GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 3 of 6 I I ] TRINITY!ERD 4.3 Accessory Starter Strips: .4.3.1 Pro-Start®Eave/Rake Starter Strip Shingles and WeatherBlocker"'Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified bitumen starter strip,nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6- inch or less. 4.3.3 StarterMatch" Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatch"A are installed as the second starter for Grand Canyon°and Grand Sequoia®series installations. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Unity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classiflcation: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D715k Class H,indicating the shingles are acceptable for use in all wind zones Up to Vasd=150 mph(V„n=194 mph).. Refer to Section 6 for installation requirements to meet this wind rating.- 5.4.2 The GAF hip•&ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and 11905.2.6.1 to ASTM D3161,Class F, indicating the shingles are acceptable for use in ail wind zones.up to Vasa=150 mph(V„n=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C,as defined in FBC 1609.4.3,and a heigniTt Vynau Tee or less. calculations by'a. qualifieddesign professional are required for condition's outside these limitations. Contact the shingle manufacturer for data specific to each shingle. . 'S.5 Ali products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. _ 6. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. �6.2 Starter Shingles or Starter Strip: 6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip Shingles and QuickStart Peel&Stick Starter Roll shall comply with the.GAF current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of as shingles.shall comply with the GAF current published instructions, using minimum four (4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: ➢ Camelot, Camelot 11, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five(5)nails per shingle. ➢ Slateline requires minimum six(6)nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6 or R90S.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. Exterior Research and Design,I.I.C. Evaluation Report 01506.01.09-RZ2 CertiJfcate ofAuthoHzatlon#9503. 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1120 -GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 4 of 6 TRINITY ERD 6.4 Hip&Ridge Shingles: 6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and Seal-A-Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel"Loctite Pl.S30 Roof&Flashing Sealant". 11:5' 4ellante ealant 1• (292mm) 1' (25 mm) (25 rnnduit d'dtancheitd �. 12' (305 mm) Nail Clavo 6 5/8'-7 5/8' Clouer (168-194 mm) 12' (305 mm) - 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two.(2),nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NPi Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. tt 5 Sealant • 1' (2°2 rn-rl 1 Sellarrl0 (2S inml {?5 im r-rd6it d'dtarch6 t6 F1 . t Nai (305 Trn j 9 1229 mr•Y, 12' {305 mT1 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1S07.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122 i C&V lcate ofAuthorkallon#9503 6"EDITION(2017)FBC NON-HVH2 EVALUATION FL10124-1120 j GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 5 of 6 I t , TRINITY ERD 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/11905.2.6.1.- 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of 'this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(847)664-3281 END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 01SO6.01.08&R22 Gertipcote ofAuthorkation A9503 6'EDITION(2017)FOC NON-HVHZ EVALUATION FL10124-R20 GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 6 of 6 i