Loading...
HomeMy WebLinkAboutProduct Approval (2) 7/31/2019 Florida Building Code Online � s A , 130S Home ( Log In user Registration Hot Topics I Submit Surcharge Stats&Facts I publications I Contact us Bas Site Map Unix Search FI 'dId i Pro duct Approval USER:Public User r @ Product Approval Menu.>Product or Agpllcation Search>application List>Application Detail FL FL16717-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W.Newport Center Drive Deerfield'Beach,FL 33442 (954)233-1330 Ext242 rbalpert@polyglass.com Authorized Signature Maury.Alpert fnalpert@polyglass.com Technical Representative Maury Alpert Address/Phone/Email 1111 W.Newport Center Drive Deerfield Beach,FL 33442 (912)429-8610 MAlpert@polygiass,com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/13/2021 Validated By Sohn W.Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL16717 R7 C01 2019 01 COI NIEMINEN.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D2178 2004 ASTM D4601 2012 ASTM D6162 2008 ASTM D6163 2008 ASTM D6164 .2011 ASTM D6222 2011 ASTM D6509 2009 TAS 110 2000 TAS 114 2011 v Jww.floridabuild'ing.org/pr/pr app dti.aspx?param=wGEVXQwtDqu6obl%2flZm6TpmvJBPDIAvtU4TdiLa%2f7C8EEaycfzy6LQ%3d%3d 1/2 is 7131l2019 Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted - 04/12/2019 Date Validated 04/14/2019 Date Pending FBC Approval 04/19/2019 Date Approved 06/18/2019 Summary of Products FL# Model,Number or Name Description 16717.1 Polyglass SBS and APP Modified bitumen roof systems Modified Bitumen Roof Systems Limits of Use. Installation Instructions Approved for use in HVHZ:Yes FL16717 R7 II 2019 04 FINAL Al ER POLYGLASS MODBIT HVHZ FL16717- Approved for use outside HVHZ:No 117,pdf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes Other: 1.)The design pressure in this Evaluation Reports application pertains to one system.Refer to ER FL16717 R7 AE 2019 04 FINAL ER POLYGLASS MB HVHZ FL16717-R7 adf Appendix for all systems and maximum design Created by Independent Third Party:Yes pressures.2.)Refer to ER Section 5 for Limits of Use. Back ER Contact us:;2601 Blair Stone Road,Tallahassee FL 32399 Phone:-850-067-1624 The State of Florida Is an AA/EEO employer..gaPyrlght9007-2D33 State of Florida. Prlvad Statement::Acaesslbllity Statement::Refund Statement Under Fiarida law,email addresses are public records.If you.do not want your e-mall address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.;Pursuant to Section455.275(1),. Florida statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click bp e. Product Approvil Accepts:. Credit Card We www.flaridabuilding.org/prfpr app_dtl.aspx?param=wGEVXQwtDqu8obl%2flZm6TpmvJBPDIAvtU4TdiLa%2f7C8EEaycfzy6LQa/a3da/o3d 2/2 ONEMOjetc. APPENDIX 1:ATTACHMENT RFQUIRFMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 6-10 1B Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 10-11 iC Woad New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 12 ID Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 13-14 3E Wood New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 15-17 1F Wood New or Reroof(Tear-Off) E Non-Insulated,Mech:Attached Base Sheet,'Bonded Roof Cover 18-20 1G Wood New,Reroof(Tear-Off)or Recover E Nan-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 21-26 2A Steel or Structural Concrete New,Reroof(Tear-Off)or Recover B Mech.Attached.Base Insulation,Bonded Top Insulation,Bonded Roof Cover 27-28 2B Steel or Structural Concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 29-32 2C Steel or Structural Concrete New,Reroof(Tear-Off)or Recover D-1 Insulated,Meth.Attached Base Sheet,Bonded Roof Cover 33-34 2D Steel or Structural concrete New,Reroof(Tear-Oft)or Recover D-2 Insulated,Mech.Attached Velociflex,Bonded Roof Cover 35-36 3A Structural Concrete New or Reroof[Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 37-45 3B Structural Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 45 4A Lightweight concrete New or Reroof(Tear-Off) A-1 Bonded insulation,Bonded Roof Cover 46-48 4B Lightweight concrete New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 49 4C Lightweight concrete New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 50-52 SA Cementitious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 53 5B Cementitious wood fiber New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 54 5C Cementitious wood fiber New,Reroof(Tear-Off)or Recover B Mech.Attached Base insulation,Bonded Top Insulation,Bonded Roof Cover 55 SD Cementitious wood fiber New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 55 SE Cementitious wood fiber New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet Bonded Roof Cover 55 6A Existing gypsum New or Reroof(Tear-Off) A-1 Bonded insulation,Bonded Roof Cover 56-58 6B Existing gypsum New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 59 6C Existing gypsum New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 59 6D Existing gypsum New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet Bonded Roof Cover 59 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 60-64 MEMO ETC,LLC Evaluation Report P40690.12.13-1-R8 for FL36717-117 Certificate of Authorization f13245S 6P EDITION(2017)FBC HVHZ EVALUATION Revision 8:04/11/2019 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems,(9S4)233-1330 Appendix 1,Page 1 of 64 NEMO etc. The following notes apply to the systems outlined herein: L The evaluation herein pertains to above-deck roof components;deck-attachment details noted below pertain to'as-tested'conditions under Testing Application Standard TAS 114,Appendix J. Roof decks shall be in accordance with FBC(HVHZ)requirements to the satisfaction of the Authority Having Jurisdiction. TYPE TESTED SPAN(FT O.C.) TESTED FASTENING TESTED FASTENER SPACING HIGHEST AS-TPSTEd'ALLOWABLE (INCH O:C.) PRESSURE(PSF) 15/324rich plywood 2 8d ring shank nails 6 -75.0 15/324nch plywood 2 #10 wood screws 6 -90.0 15/324nch plywood 2 #10 wood screws 4 -120.0 19/32-Inch plywood 2 8d ring shank nails 6 -60.0 19/32-Inch plywood 2 #10 wood screws 6 -127.5 22 ga.,Type B,Grade 33 steel 6 Tek/5 screws 6 -112.5 22 ga.,Type B,Grade 40 steel 6 5/8"puddle welds 6 -97.5 22 ga.,Type B,Grade 40steel 6 Traxx/5 screws with V"washers 6 -135.0 2. Fasteners shall be of sufficient length for the following engagements: ➢Wood: Minimum 0.754nch penetration. ➢Steel: Minimum 0.75-Inch penetration and engage the top flute of the steel deck. >Structural Concrete: Minimum 1.25-Inch embedment into pilot hole In accordance with fastener manufacturer's published Installation Instructions. 3. Unless otherwise noted,insulation may be any layer or combination of polyisocyanurate,polystyrene,cement-based roof board,gypsum-based roof board,mineral-wool,perlite or wood fiberboard that meets the CIA requirements of F.A.C.Rule 61GZO-3 and is documented as meeting FBC(HVHZ)1516 and,for foam plastic,FBC Chapter 26,when Installed with the roof cover. 4. If mechanical attachment'to the structural deck through lightweight insulating concrete Is proposed,field withdrawal resistance testing shall be performed to confirm equivalent or determine enhanced fastening patterns and density. All testing and fastening design shall he In compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 11.7 and/or Roofing Application Standard RAS 137. Calculations shall be prepared,signed and sealed by a qualified design professional. S. Preliminary Insulation attachment for System Type D=Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board. 6. Unless otherwise noted,insulation adhesive application rates areas follows. Ribbon or bead width is'at the time of application;the ribbons/beads shall expand.as noted in the manufacturer's published instructions. ➢ Hot asphalt(HA): Full coverage at 25-30lbs/square. ➢Dow INSTA STIK Quik Set Insulation Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,22-inch o.c. > Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0:25 to 0.5-inch wide ribbons,12-inch o.c. ➢Millennium PG-1 Pump Grade Adhesive.(M-PG3): Continuous 0.25 to 0.5-Inch wide ribbons,12-inch o.c. ➢OMG OlyBond 500(08500): Continuous 0.75 to 1-inch wide ribbons,12-Inch o.c.(PaceCart or SpotShot). Note: OlyBond Green maybe used where OlyBond 50015 referenced. > Oly8ond Classic(08 Classic): Full coverage at 1 gal/square. >ICP Adhesives Polyset CR-20: Continuous 2.5-3.5-inch wide ribbons,12-Inch o.c. > Note: When multiple layers(s)of insulation and/or coverboard are installed In ribbon-applied adhesive,board joints shall be staggered. ➢Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7, Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the-following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to Increase'the MDP listings In the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: > Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick) ➢Millennium PG-1 Pump Grade Adhesive(M-PG* MDP -157.5 psf (Min.0.5-inch thick) NEMO ETC,LLC Evaluation Report P40690.12.13-1 RB for FL16717-R7 Certificate of Authorization#32455 6m EDITION(2017)FBC HVHZ EVALUATION Revision 8:04/11/2019 Prepared by:Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(9S4)233-2330 Appendix 1,Page 2 of 64 ONEMOJetc.- > OMG OlyBond 500(08500): MOP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3) D OMG OlyBond SOD(OB50D): MOP -187.5 psf (Min.0.5-Inch thick ISO 95+GL) ➢OMG OlyOond 500(00500): MDP -315.0 psf (Min:0.5-Inch thick ENRGY 3) ➢OMG Oly8ond 50D(OB50D): MDP -487.5 psf (Min.O.5-Inch thick ACFoam II) ➢ICP Adhesives Polyset CR-20: MDP -117.5 psf (Min.1.04nch thick) 8. Banded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased,as calculated in compliance with Roofing Application Standard RAS 117 and/or Roofing Application Standard RAS 137 by a qualified design professional. 'This extrapolation is not permitted forsystems marked with an asterisk'. 10. For assemblies marked with an asterisk",the maximum design pressure(MDP)limitation listed shall be applicable to all roof pressure zones(i.e.,field,perimeters and corners).Neither rational analysis,nor extrapolation is permitted for enhanced attachment at enhanced pressure zones(Le.,perimeters,corners and extended corners). 11. Fastener spacing for mechanical attachment of insulation,anchor/base sheet or membrane is based on a minimum fastener resistance value in conjunction with the maximum design pressure(MDP)listed for a specific system.Should the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing—prepared,signed and sealed by a qualified design professional—may be.submltted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standard TAS 165 and calculations in compliance with Roofing Application Standard RAS 117 or Roofing Application Standard RAS 137. 12. For bonded Insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on Its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with Testing Application Standard TAS 124. 13. For recover Installations,the existing roof shall be examined In accordance with FBC1521. For Recover Applications using System Type D,the insulation is optional. 14. Lightweight Insulating Concrete(LWC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC Is referenced,refer to current LWC NOA or HVHZ Product Approval for specific deck construction and limitations. For systems where specific LWC Is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thlckness is 2- inches. For LWC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent"LWC references,listings were established through testing over lightweight concrete cast using only foaming agent(ASTM C896),water and Portland cement(ASTM C15%with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO(FBC CER3592). Unless otherwise noted,use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. •• ROOF COMS REFERENCE IAYER MATERIAL APPLICATION BP-AA Base Ply One or more lies Polyglass G2 Base,FBC Approved ASTM D4601,Type II Hot Asphalt at 20.40 (Base and Ply sheets, Ply One or-more plies Polyglass:PlyIV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV or VI Ibs/square Asphalt-Applied) Note. Asphalt-applied sheets or insulation shall not be appUed to poly-J!!m surfaced membranes Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 HP,Elastoshield HT RG350 at 1.5-2.0 SBS-CA1 Cap Ply Elastoflex VG,Elastoflex V G FR,Elastoflex 56,Elastoflex S6 HP,Elastoflex S6 G,Elastoflex S6 G Fit,Elastoshield TS G,Elastoshield TS gal/square G FR,PolVfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) Base Ply One plyflastobase(sand/sand),Elastoflex V,Elastoflex 56,Elastoflex S6 HP Polyplus 35 at 1.5-2.0 SBS-CA2 Ca PI Elastoflex V G,Elastoflex V G FR,Elastoflex S6,Elastoflex S6 HP,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshleld TS G;Elastoshield TS p y G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) gal/square NEMO ETC,LLC Evaluation Report P40690.12.13-1-118 for;FL36717-R7 Certificate of Authorization#32455 a EDITION(2017)FBC HVHZ EVALUATION Revision 8i 04/11/2019 Prepared by: Robert Nieminen,PE-59156 Polyglass Modlfled Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 3 of 64 - NEM0 etc.-- P. REFERENCE I LAYER MATERIAL APPLICATION Base Ply or Ply One or more plies Elastobase(sand/sand or poly/sand),Elastobase P(sand/sand or poly/sand),Elastoflex V,Elastoflex S6,Elastoflex SBS-AA S6 HP,Elastoshleld HT Hot Asphalt at 20410 (SBS,AsphaR-Applied) Cap Ply Elastoflex V,Elastoflex V G,Elastoflex V G FR;Elastoflex S6,Elastoflex S5 HP,Elastoflex S6 G,Elastoflex S6 G FR,.Elastoshleld TS G, Ibs/square Elastoshield TS G FR,Poiyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed). Note. Asphalt-applied sheets or Insulation shall not be applied to poly-flm surfaced membranes. SBS-TA Base Ply or Ply One or more plies Elastobase(sand/poly),Elastobase(poly/poly),Elastoflex V,Elastoflex S6,Elastoflex S6 HP,Elastoshleld HT (SBS,Torch-Applled) Cap Ply Elastoflex V,Elastoflex V G,Elastoflex V G FR,Elastoflex 56,Elastoflex 56 HP,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshleld TS G, Torch-Applied Elastoshleld TS G FR,Polyfresko G SBS(poly-film backed),Polyfresko G SBS FR(poly film backed) Base Ply One or more plies Elastoflex SA V,Elastoflex SA V FR,Elastoflex SA V Plus,Elastoflex SA V Plus FR SBS-SA Cap Ply Elastoflex 5A P,Elastoflex SA PTR;Polyreflect Self-Adhering (SBS,Self-Adhering) Note: Unless otherwise noted,permissible membrane substrates jorSBS-A are limited to the SBS-SA Base Ply options herein, Elastobase(poly/sand)o►Elastobase.(poly/poly). APP-CAI Cap Ply Polyflex G FR PG350 at 1.5-2.0gal/square APP-TA Base Ply or Ply One or more plies Polyglass Base,Polyflex,Polybond Torch-Applied (APP,Torch-Applied) Cap Ply I Polyflex,Polyflex G,Polyflex G FR,Pol bond,Polybond G,Polyfresko G,Polyfresko G FR APP-SA Cap Ply Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polykool (APP,Self-Adhering) Note. Unless otherwise noted,permissible membrane substmtes jorAPP-SA are limited to the SBS-SA Base Ply options herein, Self-Adhering Elastobase(poly/sand)or Elastobase(poly/poly). 16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure(MOP)limitations. The lesser of the MOP listings below vs.those in Table 3A applies: •• . .N PE R TABLE OPTION PRIMER VAPOR BARRIER INSULATION ADHESNE MDP # TYPE ATTACH (PSF) VB-1. PG100 Elastoflex SA V Plus Self-Adhering Inta-Stlk or CR-26,12-inch o.c -60.0 VB-2. PG100 Polyglass Base Torch-appiled Inta-Stik or CR-20,12-Inch o.c. -75.0 VB-3. PG100 Elastoflex SA P Self-Adhering Insta-Stlk,12-inch o.c -75.0 VB-4. PG100 Elastoflex SA P Self-Adhering Millennium One Step Foamable Adhesive,12-Inch o.c. -157.5 VB 5. PG100 Elastoflex SA P Self-Adhering CR-20,12-inch o.c. -270.0 VB-6. PG100 Elastoflex SA V,Elastoflex SA V FR,Elastoflex SA V Self-Adhering Millennium One Step Foamable Adhesive,Millennium PG-1 Pump Grade -290.0 Plus,Elastoflex SA V Plus FR Adhesive,OlyBond 500 or CR-20,12-inch o.c.. NEMO ETC,LLC Evaluation Report P40690.12.13-1-118 for FL16717-R7 Certificate of Authorization#32455 6'"EDITION(2017)FBC HVHZ EVALUATION Revision 8:04/11/2029 Prepared by. Robert Nleminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(9S4)233-1330 Appendix 1,Page 4 of 54 -ON EMO'- etc. 17. The following surfacing maybe applied to the Cap Ply without adverse effect on the system wind load performance.,Refer to current Florida Product Approval for,approved Polygiass and KM Coatings roof coatings for application limitations and a Roofing Materials Director forfire ratings associated with'coating usage. OPTIONSSURFACING OPTION# SURFACING NOA SURF-1. PG300 Fibered Roof Coating 17-1020.01 SURF-2. PG600 Non-Fibered Aluminum Roof Coating 17-1020.01 SURF-3. PG650 Fibered Aluminum Roof Coating, 17-1020.01 SURF-4. PG700 High Quality'Elastomerie Roof Coating 17-1020.01 SURF-S. PG700Q5(Quick Set)High Quality Elastomeric Roof Coating 17-1020.01 SURF-15. PG800 Asphalt Emulsion Roof Coating 17-1020.01 SURF-7. Polyplus 60 Premium Non-Flbered Aluminum Roof Coating 17-1020.01 SURF-8. Polyplus 65 Premium Fibered Aluminum Roof Coating 17-1020.01 SURF-9. Polybrlte 70 Premium Grade Elastomeric Roof Coating 17-1020.01 SURF-10. Polybrite 70QS(Quick Set)Premium Grade Elastorneric Roof Coating 17-2020.01 SURF-11. Polybrite 90 High Solids Silicone.Roof Coating 17-1020.01 SURF-12. Polybrite 95 Silicone Roof Coating 17-1020.01 SURF-13. KM Acryl 15 17-1020.01 SURF-14. KM Acryl 15 CIS 17-1020.01- SURF-15. KM Acryl 25 17-1020.01 SURF-16. KM Acryl 25 QS 17-1020.01 SURF-17. KM PS9250 174020.01 SURF-18. KM PS#220 17-1020.01 18. "MDP"=Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC(HVHZ)1620 and RAS 128 for determination of design wind loads. i NEW ETC,LLC Evaluation Report P40690.12.13-1-118 for FL16717-R7 Certificate of Authorization#32455 6-EDITION(2017)FBC HVHZ EVALUATION Revision 8:04/11/2019 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 5 of 64 "NEMO]etc. TABLE 11`� WOOD DECKS-NEW CONSTRUCTION OR REROOF(TCAR-OU) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAILS),BONDED ROOF COVER System Base Sheet Roof Cover(Note 15) MDP No. Deck(Note 1) Type Fasten Attach Base Ply Cap Ply (P�) 1D-inch o.c.In 4-Inch lap and 10-inch o.c.in W-302. Min.15/32-Inch plywood Polyglass Base Simplex MAXX Cap three(a),equally spaced,staggered center APP-TA APP-TA -75.0 rows W-103. Min.15/32-Inch plywood Polyglass G2 Base,Elastobase, Simplex MAXX Cap 9-inch o.c.in 4-inch lap and 9-inch o.c.in four BP-AA,SBS-AA,SBS- SBS-SA,APP-SA,SBS- _90 0 Elastobase P (4),equally spaced,staggered center rows TA,APP-TA AA,SBS-TA,APP-TA W-104. Min.15/32-Inch plywood Polyglass Base Simplex MAXX Cap 9-inch o.c.in 4-Inch lap and 9-inch.o.c.in four App_TA APP-TA -90.0 (4),equally spaced,staggered'center rows W-1o5. Min.15J32-Inch plywood Elastobase,Elastobase P Simplex MAXX Cap 6-inch o.c.at 2 Inch lap and 6-inch o.c.in two BP-AA,SBS-AA,SBS- SBS-SA,APP-SA,.SBS- _g0.0 (2),equally spaced,staggered center rows TA,APP-TA AA,SBS-TA,APP-TA W-106. Min.15/3Z-inch plywood Elastobase,Elastobase P Simplex MAXX Cap 6-Inch o.c.at 2-inch lap and 6-Inch o:c.in three BP-AA,SBS-AA,SBS-' SBS-SA,APP-SA,SBS- 105.0 {3),equally spaced,staggered center rows TA,APP TA AA,SBS-TA,APP TA W-ID7. Min.19/32-inch plywood Elastobase,Elastobase P 32 ga.,1-5/8-Inch diametertln caps with 11 6-Inch o.c.Im4-Inch lap and 6-Inch o.c.In four BP-AA,SBS-AA,SBS- SBS-SA,APP-SA,SBS- _312.5 ga.annular ring shank nails (3),equally spaced,staggered center rows TA,APP TA AA,SBS-TA,APP•TA 'SEIF•ADNfRINGBASEPLY: .' :." ;: i �: a lxo 1 P; 7'Ak i�yt°y_, r r :r�.,,a s Min.15/32-inch(existing) Simplex MAXX Cap B-Inch o.c.at min.3-inch lap and 8-inch o.c.at SBS-SA,APP-SA,SBS- W-108. or min.19/32-inch(new) Elastobase(poly-film top) Note:MAX(Caps are to be primed with three(3),equally spaced,staggered center SBS-SA TA,APP TA 6D.0 APA rated plywood PG100orASTM 041 primer rows "isr` Elastobase,Elastobase P(poly- 32 ga,1-5/8-inch diameter tin caps with 11 8-inch o.c.in 4-Inch lap and 8-inch o.c.in three SBS-SA SBS-SA,APP-SA,SBS- _60.0 s�VU 1p�;j Min.19/32-Inch plywood 4 film to a` 3:,a31;d„r p) g annular ring shank nails (3),equally spaced,staggered center rows TA,APP TA Elastobase,Elastobase P(poly- 32 ga.,1.5/84nch diameter tin caps with 11 B-Inch o.c.In 4-Inch lap and 8-Inch o.c.in three poi ex SA Base APP-TA -60.0 W-110. Min.19/32-Inch plywood film top) ga.annular ring shank nails (3),equally spaced,staggered center rows W-111. Min.19/32-inch plywood Elastobase,Elastobase P(poly- 32 ga.,1-5/84nch diameter tin caps with 11 4-inch o.c.in 4-Inch lap and 4-inch o.c.in four SBS-SA SBS-SA,APP-SA,SBS- -97.5 film top) ga.annular ring shank nails. (4),equally spaced,staggered center rows TA,APP-TA Elastobase,Elastobase P(poly. 32 ga.,1-5/e-inch diameter tin caps with 11 4-Inch o.c.In 4-inch lap and 4-Inch o.c.in four Pol ex SA Base APP TA -97.5 W 312. Min.19/32-Inch plywood film top) ga.annular ring shank nails. (4),,equally spaced,staggered center rows 32 ga.,1-5/8-Inch diameter tin caps with 11 Elastoflex SA V Plus, W-113. Min.19/32-inch plywood Elastobase,Elastobase P(poly- ga.annular ring shank nails. Note:Tin caps 6-Inch o.c.In 4-Inch lap and 64nch o.c.in four SBS-SA,APP-SA,SBS Elastoflex SA VPlus -112.5 film top) an,to be primed with P6100 orASTM 041 (4),equally spaced,staggered center rows FR TA,APP TA primer. 32 ga.;1-S/84nch diameter tin caps with 11 W-114. Min.19/32-inch plywood Elastobase,Elastobase P(poly- ga.annular ring shank nails.Note:Tin caps 6-Inch oc.in 4-Inch lap and 6-Inch o.c.in four Polyflex SA Base APP-TA -112.5 film top) are to be primed with PG100 orASTM D41 (4),equally spaced,staggered center rows primer. NEMO ETC,LLC Evaluation Report P40690.12.13-1-118 for FL16717-117 Certificate of Authorization#32455 67"EDITION(2017)FBC HVHZ EVALUATION Revision 8:04/11/2019 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 20 of 64