REPLACE DOOR IN 1 OPENING ONLY.
NEW DOOR TO BE IMPACT,RESISTANT-
HURRICANE SHUTTERS NOT REQUIRED.
i
I
I
OPENING PRODUCT DESIGN I
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 36 80 20.00 5 36.1 -47.2 FL16708.1 --6-5-0--T-65.0 FAMILY ROOM-LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
i
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
I
LESS THAN 30%OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING.EXEMPT FROM 2017 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 11 FT 6 IN
KICLITER RESIDENCE
1903 WYOMING AVENUE DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA