HomeMy WebLinkAboutNOA-Tile 9-savEv
1
perm�tt�g 1e Go0^gent
St.
,,Q MIAMI-DADE COUNTY
MIAMI-QADE O'L!� PRODUCT CONTROL SECTION
SEA— r' 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) l� Miami,Florida.33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) REVIEWED FOR www.miamidade.aov/economy
Eagle Roofing Products LLC CODE COMPLIANCE
1575 East,C.R.470 ST. LU C I E COUNTY
Sumterville,FL 33585
BOCC (A(f
C�(�`f
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use-of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade.County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur,the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: High Profile Concrete Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA-shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA.shall be cause for,termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No.17-0822.15 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Semino File ®p ,/
NOA No.18-0523.04
CMLDADEMC OUNTY Expiration Date: 10/05/21
• Approval.Date: 07/19/18
Page 1 of 7
I . -
ROOFING ASSEMBLY APPROVAL
Category: . Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE:
This approves a new roofing system using High Profile Concrete Tile as manufactured by Eagle Roofing
Products LLC in Sumterville,FL and described in Section 2 of this Notice of Acceptance. For use in locations
where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure
values obtained by calculations in compliance with RAS 127 using the values,listed in section 4 herein. The
attachment calculations shall be done as a moment based system.
2.PRODUCT DESCRIPTION:
Manufactured by Test Product
Applicant Dimensions Specifications Description
High Profile Concrete Tile Lenght= 17" TAS 112 High profile concrete roof tile. For direct deck or
Width= 12 V4" Type 1a battened nail-on applications.
Thickness=_V2" Class III
Trim Pieces Lenght=varies TAS 112 Accessory-trim,concrete roof pieces for use at
Width=varies hips,rakes,ridges and valley terminations.
varying thickness Manufactured for each tile profile.
2:1 PRODUCTS MANUFACTURED BY.OTHERS
Product Name Product Description Manufacturer
(With Current.NOA)
ICP Adhesives Polyset®AH-160 Two component polyurethane ICP Adhesives and Sealants,Inc.
foam adhesive.
TILE BOND'Roof Tile Adhesive Single component polyurethane The Dow Chemical Company
foam roof tile adhesive.
DAP Foam Touch N Seal Two component polyurethane The Dow Chemical Company
StormBone 2 Roof Tile Adhesive foam adhesive.
2.2 MANUFACTURING LOCATION
2.2.1. Sumterville,FL
NOA No.18-0523.04
CMAMWADEouNW Expiration Date:10/05/21
• Apprbval'Date: 07/19/18
Page 2 of 7
2.3 EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
PRI Asphalt Technologies ERPF-001-02=03 TAS-1.12 Aug.2006
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III TAS 102& 102(A)
Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994
1994 TAS 108 (Nail-On)
Redland Technologies P09647-01 Wind Tunnel Testing Aug. 1994
TAS 108 (Mortar Set)
Redland Technologies P0402 Withdrawal Resistance Testing of screw Sept. 1993
vs. smooth shank nails
The Center for Applied 94=083 Static Uplift Testing April 1994
Engineering,Inc. TAS 101 (Adhesive Set)
The Center for Applied 94-084 Static Uplift Testing May 1994
Engineering,Inc. TAS 101 (Mortar Set)
The Center for Applied 25-7094-(3,6& 9) Static Uplift Testing Oct. 1994
Engineering,Inc. TAS 102
The Center for Applied 25-7120-(1 &2) Static Uplift Testing Nov. 1994
Engineering,Inc. TAS 102
The Center for Applied 25-7183-(3 &4) Static Uplift Testing Feb. 1995
Engineering,Inc. TAS 102
The Center for Applied 25-7214-(3,4,&7) Static Uplift Testing March, 1995
Engineering,Inc. TAS 102
The Center for Applied 25-7804-4 Static Uplift Testing Sep. 1996
Engineering,Inc. TAS 102
Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998
Testing Services TAS 101
Celotex Corporation 520191-2-1 Static Uplift Testing March 1999
Testing Services TAS 101
Walker Engineering,Inc. Calculations Aerodynamic Multiplier Sep.2006
ATL of South Florida RT1211.02-15 TAS-112 12/17/15
ATL of South Florida RT0706.03.17 TAS-112 09/25/17
PRI Construction Materials DAPF-001-02-01 TAS 101 11/30/17
NOA No.18-0523.04
MIAMI•DADE COUNTY Expiration Date:10/05/21
• Approval Date: 07/19/18
Page 3 of 7
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications,a static field uplift test in accordance with TAS 106 shall be
required,refer to applicable Building Code.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112,appendix`A'. Such testing shall be submitted to the Miami-Dade County
Product Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless
stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable Building Code.
3.7 All products listed herin shall have aquality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
4. INSTALLATION
4.1 Eagle Roofing Products LLC, High Profile Concrete Tile and its components shall be installed in strict
compliance with Roofing Application Standard RAS 118,RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight(W)and Dimensions (I x w)
Tile Profile Weight-W(lbf) Length-1(ft) Width-w(ft)
High Profile Concrete Tile 10 1.417 1.04
Table 2: Aerodynamic Multipliers- ft3
Tile A(ft3) A(ft3)
Profile Batten Application Direct Deck Application
High Profile Concrete Tile 0.300 0.277
Table 3: Restoring Moments due to Gravity-M ft-Ib
Tile 321:12" 4":12" 511:12" 6":12" Greater than
Profile 7":12"
High Profile Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
Concrete Tile Deck Deck Deck Deck Deck
6.68 6.99 6.57 6.88 6.44 6.73 6.28 6.56 6.10 6.38
NOA No.18-0523.04
MIAWDADEC0UNMW Expiration Date: 10/05/21
Approval Date: 07/19/18
Page 4 of 7
c
Table 4: Attachment Resistance Expressed as a Moment- Mf(ft-lbf)
for Nail-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" plywood) (min. 19/32" plywood)
High Profile 2-10d Ring Shank Nails 28.6 41.2 19.4
Concrete Tile 1-10d Smooth or Screw 5.1 6.8 2.8
Shank Nail
2-10d Smooth or Screw 6.9 9.2 7.3
Shank Nails
1 #8 Screw 20.7 20.7 18.1
2#8 Screw 43.2 43.2 29.8
1-10d Smooth or Screw 23.1 23.1 19.0
Shank Nail Field Clip)
1-10d Smooth or Screw 29.3 29.3 24.0
Shank Nail Eave Clip)
2-10d Smooth or Screw 27.6 27.6 38.6
Shank Nails Field Clip)
2-10d Smooth or Screw 38.1 38.1 41.8
Shank Nails Eave Clip)
2-10d Ring Shank Nails' 33.1 48.1 45.2
1. Installation with a 4"tile headlap and fasteners are located a min. of 2%"from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
High Profile Concrete Tile Adhesive 29.3 2
493
1 See manufactures component approval for installation requirements.
2 The Dow Chemical Company TileBond Average weight er patty 10.7 grams.
ICP Adhesives Polyset@ AH-160.Average weight per patty 8 grams.
3 DAP Foam Touch N Seal StormBond 2 Roof Tile Adhesive average weight per paddy 8 grams.
Table 6: Attachment Resistance Expressed as a Moment- Mf(ft-lbf)
for Single Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
High Profile Concrete Tile ICP Adhesives Polyset®AH-160 66.53
ICP Adhesives Polyset®AH-160 38.74
3 Large paddy placement of 63grams of Polyset®AH-160.
4 Medium paddy placement of 24grams of Polyset®AH-160.
NOA No.18-0523.04
MIAMMADE couNTY Expiration Date: 10/05/21
Approval Date: 07/19/18
Page 5 of 7
• J
Table 7: Attachment Resistance Expressed as a Moment- Mf(ft-lbf)
-for Mortar Set Systems
Tile Tile Attachment
Profile Application Resistance
High Profile Concrete Tile Mortar Sets 24.5
5 Tile-Tite Roof Tile Mortar.
5. LABELING:
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See
Detail Below),or following statement: "Miami-Dade County Product Control Approved".
�Mill
EAGLEV -.
LORIDA
(LOCATED ON UNDERSIDE OF TILE)
OR
EAGLE FL
(LOCATED ON FRONTSIDE OF TILE)
High Profile Concrete Tile LABEL,SUMTERVILLE PLANT
NOA No.18-0523.04
MIAMI•DADE COUNTY Expiration Date: 10/05/21
•• Approval Date: 07/19/18
Page 6 of 7
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by AHJ or applicable Building Code in order to properly evaluate the
installation of this system.
PROFILE DRAWING
NAIL KOLE
.o_
too
12W#
High Profile Concrete Tile
END OF THIS ACCEPTANCE
NOA No.18-0523.04
MIAMMADE couNnr Expiration Date: 10/05/21
• Approval Date: 07/19/18
Page 7 of 7
r .