HomeMy WebLinkAboutProduct Approval NEMO I etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
REPORTEVALUATION
GAF Evaluation Report 01506.01.08-1124
1 Campus Drive I FL10124-R22
Parsippany, NJ 07054 Date of Issuance:01/03/2008
(800)766-3411 Revision 24:04/12/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 611 Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality
Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s),the Quality Assurance or the production facility location(s). NEW I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
� ^•.-�:'E.�,'Vit-.
Robert J.M. Nieminen, P.E. ,fiF"; ;
rr r: The facsimile seal appearing was authorized by Robert
S�. :c'• Nieminen,P.E.on 04/12/2019. This does not serve as an
Florida Registration No.59165,Florida DCA
9 i'(�•..uia" electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOIetc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project
on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically
for that purpose.
ONEMOletc.
ROOFING SYSTEMS EVALUATION:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF, have demonstrated compliance with the
following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
STANDARDS:2.
Section r Property Standard Year
1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Entity- Examination Reference Date
PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011
PRI(TST 5878) ASTM D1970(QuickStart) GAF-340-02-01 03/13/2012
PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
PRI(TST 5878) Wind Driven Rain GAF-895-02-01 11/20/2018
PRI(TST 5878) Wind Driven Rain GAF-896-02-01 11/20/2018
PRI(TST 5878) ASTM D3462 GAF-897-02-01 11/08/2018
PRI(TST 5878) ASTM D3462 GAF-898-02-01 11/08/2018
PRI(TST 5878) ASTM D3462 GAF-899-02-01 11/15/2018
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 01NK06632 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001
UL(TST 1740) ASTM D3161 01NK37122 12/18/2001
UL(TST 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
MEMO ETC,LLC Evaluation Report 01506.01.08-1124
Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R22
GAF Asphalt Roof Shingles Revision 24:04/12/2019
Page 2 of 6
ONEMOjetc.
Entity Examination Reference Date
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008
UL,LLC.(TST 9628) ASTM D3161 4788698165 03/24/2008
UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010
UL(TST 1740) ASTM D3462 10CA07264 05/27/2010
UL(TST 1740) ASTM D3462 10CA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4788717529 09/09/2016
UL,LLC.(TST 9628) ASTM D3161 4788669132 12/13/2018
UL,LLC.(TST 9628) ASTM D3161 4788891098 02/14/2019
UL,LLC.(QUA 9625) Quality Control Service Confirmation 10/18/2018
4. ' ••DDESCRIPTION:
4.1 ACCESSORY STARTER STRIPS:
4.1.1 Pro-Start° Eave/Rake Starter Strip Shingles and WeatherBlockerTM Premium Eave/Rake Starter Strip Shingles are
starter strips for asphalt roof shingles. Meets ASTM D3462.
4.1.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified
bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6-inch or less.
Meets ASTM D1970.
4.1.3 StarterMatchTM Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon" and Grand
Sequoia®series asphalt shingles. StarterMatchTM are installed as the second starter for Grand Canyon®and Grand
Sequoia®series installations. Meets ASTM D3462.
4.2 ASPHALT SHINGLES:
4.2.1 Marquis WeatherMax°, Royal Sovereign®and Sentinel®are a fiberglass reinforced 3-tab asphalt roof shingles.
4.2.2 Camelot®, Camelot® II, Fortitude TM, Glenwood TM, Grand Canyon°, Grand Sequoia®, Grand Sequoia® IR, Grand
Sequoia® ArmorShield TM, Sienna®, Timberline® American Harvest®, Timberline® ArmorShieldTM II, Timberline®
Natural Shadow®, Timberline HD®, Timberline® HDZTM, Timberline® Cool Series®, Timberline Ultra HD® and
Woodland®are fiberglass reinforced, laminated asphalt roof shingles.
4.2.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle.
NEMO ETC,LLC Evaluation Report 01506.01.08-1124
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1122
GAF Asphalt Roof Shingles Revision 24:04/12/2019
Page 3 of 6
ONEMO I etc.
4.3 HIP&RIDGE SHINGLES:
4.3.1 Seal-A-Ridge®Ridge Cap Shingles,Seal-A-Ridge®ArmorShieldT"°Ridge Cap Shingles and Timbertex®Premium Ridge
Cap Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in
all wind zones up to Vasd=150 mph (Vit=194 mph). Refer to Section 6 for installation requirements to meet this
wind rating.
Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.2 The GAF hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to Vnd=150
mph(V,it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 GENERAL:
6.1.1 Roof deck,slope, underlayment and fasteners shall comply with FBC 1507.2/R905.2 and the shingle manufacturer's
minimum requirements.
6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally
Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitteq.
6.1.4 GAF asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set
forth in FBC Section 1511 or R908 and CertainTeed published installation instructions.
6.2 STARTER SHINGLES OR STARTER STRIP:'
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip Shingles
and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions.
NEW ETC,LLC Evaluation Report 01506.01.08-1124
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-1122
GAF Asphalt Roof Shingles Revision 24:04/12/2019
Page 4 of 6
ONEMOjetc.
6.3 ASPHALT SHINGLES:
6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4)
nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions:
➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and
Woodland require minimum five(5)nails per shingle.
➢ Slateline requires minimum six(6)nails per shingle.
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.3.2.1 Fastening for Timberline® HDZ11;slopes 2:12 up to 21:12
1 39-3/8"(1 m)
7 11-518'-14-518'(295mm-372mm) 11-518'-14.518'(295mm-372mm)
112'-2-112'(1 3mm-64mm) UT-2-11T(131nm-64mm)
13-1/4" TARGET NAIL ZONE
!337mm) ::
ZONA OBJETIVO DE CLAVADO
67/8" 5-13116'-7-5/8'(1 48mm-194mm)
Fl . F Ft
STANDARD NAILING PATTERN:
Nail shingles approximately 6 7/8'(174 min)from bottom of shingle,in nailing area,as shown.Nails must not be exposed.Not for use on
Mansard roofs(21:12 slope and above).
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required.
Contact the GAF for details.
6.3.3.1 Fastening for Timberline® HDZT"";slopes greater than 21:12
39-3/8'(1m)
74-1fI-77-1fY 1386man-a45mm) 14-12'-17-12'(368mm-445mm)
6-1,7-9-1,7 165mm-241mm &1?-9-M,165mm-241mm
tft-212'(13mm-64m) 12'-2-12'{13mm-61mm)
13-1/4 5-13/16'-6-114'(1 48mm-159 mm)
[I El
(3Tmm}
ENHANCED NAILING PATTERN:*
These shingles MUST be nailed a nominal 6"(152 mm)from bottom of shingle,above the cut-outs,as shown.Nails must not be exposed.
NEMO ETC,LLC Evaluation Report 01506.01.08-1124
Certificate of Authorization#32455 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R22
GAF Asphalt Roof Shingles Revision 24:04/12/2019
Page 5 of 6
NEM®I etc.
14
6.4 HIP&RIDGE SHINGLES:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles 11.5" Sealant
and Seal-A-Ridge ArmorShield Ridge Cap (251. (292 mm) (25 mm) Sellante
mm)Shingles shall comply with the GAF current Endufld'etancheite
published instructions with a minimum two (2)
Wa
nails, minimum 3/8-inch head diameter, per
, r.
' shingle and nominal 0.25-inch diameter beads
of Henkel "Loctite PL S30 Roof & Flashing
Sealant". (305 mm)
Nail {
Clavo
6 5/8°-7 5/8" Clouer
(168-194 mm)
12"
(305 mm)
6.4.2 Installation of Timbertex Premium Ridge Cap 11.51
Shingles shall comply with GAF current 1" (292 mm) 1^ lant
Selalante
published instructions with a minimum two (2) (25Mm) (25 mm) Enduitd'6tanchdit8
nails, minimum 3/8-inch head diameter, per
shingle and beads of Sonneborn "NP1 Gun
Grade Polyurethane Sealant" or Henkel "PL
Roofing and Flashing Sealant". Nall
Clavo 12"
Clouer (305 mm)
9"
(229 mm)
12"
(305 mm)
6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5.
Staples are not permitted.
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3
QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com
- END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 01506.01.08-R24
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-1122
GAF Asphalt Roof Shingles Revision 24:04/12/2019
Page 6 of 6