Loading...
HomeMy WebLinkAboutProduct Approval NEMO I etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION GAF Evaluation Report 01506.01.08-1124 1 Campus Drive I FL10124-R22 Parsippany, NJ 07054 Date of Issuance:01/03/2008 (800)766-3411 Revision 24:04/12/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 611 Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). NEW I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: � ^•.-�:'E.�,'Vit-. Robert J.M. Nieminen, P.E. ,fiF"; ; rr r: The facsimile seal appearing was authorized by Robert S�. :c'• Nieminen,P.E.on 04/12/2019. This does not serve as an Florida Registration No.59165,Florida DCA 9 i'(�•..uia" electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOIetc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. STANDARDS:2. Section r Property Standard Year 1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entity- Examination Reference Date PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI(TST 5878) ASTM D1970(QuickStart) GAF-340-02-01 03/13/2012 PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 PRI(TST 5878) Wind Driven Rain GAF-895-02-01 11/20/2018 PRI(TST 5878) Wind Driven Rain GAF-896-02-01 11/20/2018 PRI(TST 5878) ASTM D3462 GAF-897-02-01 11/08/2018 PRI(TST 5878) ASTM D3462 GAF-898-02-01 11/08/2018 PRI(TST 5878) ASTM D3462 GAF-899-02-01 11/15/2018 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 01NK06632 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001 UL(TST 1740) ASTM D3161 01NK37122 12/18/2001 UL(TST 1740) ASTM D3462 01NK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 UL(TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 MEMO ETC,LLC Evaluation Report 01506.01.08-1124 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R22 GAF Asphalt Roof Shingles Revision 24:04/12/2019 Page 2 of 6 ONEMOjetc. Entity Examination Reference Date UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008 UL,LLC.(TST 9628) ASTM D3161 4788698165 03/24/2008 UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010 UL(TST 1740) ASTM D3462 10CA07264 05/27/2010 UL(TST 1740) ASTM D3462 10CA11953 10/29/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IONK12070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013 UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4788717529 09/09/2016 UL,LLC.(TST 9628) ASTM D3161 4788669132 12/13/2018 UL,LLC.(TST 9628) ASTM D3161 4788891098 02/14/2019 UL,LLC.(QUA 9625) Quality Control Service Confirmation 10/18/2018 4. ' ••DDESCRIPTION: 4.1 ACCESSORY STARTER STRIPS: 4.1.1 Pro-Start° Eave/Rake Starter Strip Shingles and WeatherBlockerTM Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6-inch or less. Meets ASTM D1970. 4.1.3 StarterMatchTM Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon" and Grand Sequoia®series asphalt shingles. StarterMatchTM are installed as the second starter for Grand Canyon®and Grand Sequoia®series installations. Meets ASTM D3462. 4.2 ASPHALT SHINGLES: 4.2.1 Marquis WeatherMax°, Royal Sovereign®and Sentinel®are a fiberglass reinforced 3-tab asphalt roof shingles. 4.2.2 Camelot®, Camelot® II, Fortitude TM, Glenwood TM, Grand Canyon°, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield TM, Sienna®, Timberline® American Harvest®, Timberline® ArmorShieldTM II, Timberline® Natural Shadow®, Timberline HD®, Timberline® HDZTM, Timberline® Cool Series®, Timberline Ultra HD® and Woodland®are fiberglass reinforced, laminated asphalt roof shingles. 4.2.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle. NEMO ETC,LLC Evaluation Report 01506.01.08-1124 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1122 GAF Asphalt Roof Shingles Revision 24:04/12/2019 Page 3 of 6 ONEMO I etc. 4.3 HIP&RIDGE SHINGLES: 4.3.1 Seal-A-Ridge®Ridge Cap Shingles,Seal-A-Ridge®ArmorShieldT"°Ridge Cap Shingles and Timbertex®Premium Ridge Cap Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph (Vit=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 The GAF hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to Vnd=150 mph(V,it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 GENERAL: 6.1.1 Roof deck,slope, underlayment and fasteners shall comply with FBC 1507.2/R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitteq. 6.1.4 GAF asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions. 6.2 STARTER SHINGLES OR STARTER STRIP:' 6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions. NEW ETC,LLC Evaluation Report 01506.01.08-1124 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-1122 GAF Asphalt Roof Shingles Revision 24:04/12/2019 Page 4 of 6 ONEMOjetc. 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: ➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five(5)nails per shingle. ➢ Slateline requires minimum six(6)nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.2.1 Fastening for Timberline® HDZ11;slopes 2:12 up to 21:12 1 39-3/8"(1 m) 7 11-518'-14-518'(295mm-372mm) 11-518'-14.518'(295mm-372mm) 112'-2-112'(1 3mm-64mm) UT-2-11T(131nm-64mm) 13-1/4" TARGET NAIL ZONE !337mm) :: ZONA OBJETIVO DE CLAVADO 67/8" 5-13116'-7-5/8'(1 48mm-194mm) Fl . F Ft STANDARD NAILING PATTERN: Nail shingles approximately 6 7/8'(174 min)from bottom of shingle,in nailing area,as shown.Nails must not be exposed.Not for use on Mansard roofs(21:12 slope and above). 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. 6.3.3.1 Fastening for Timberline® HDZT"";slopes greater than 21:12 39-3/8'(1m) 74-1fI-77-1fY 1386man-a45mm) 14-12'-17-12'(368mm-445mm) 6-1,7-9-1,7 165mm-241mm &1?-9-M,165mm-241mm tft-212'(13mm-64m) 12'-2-12'{13mm-61mm) 13-1/4 5-13/16'-6-114'(1 48mm-159 mm) [I El (3Tmm} ENHANCED NAILING PATTERN:* These shingles MUST be nailed a nominal 6"(152 mm)from bottom of shingle,above the cut-outs,as shown.Nails must not be exposed. NEMO ETC,LLC Evaluation Report 01506.01.08-1124 Certificate of Authorization#32455 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R22 GAF Asphalt Roof Shingles Revision 24:04/12/2019 Page 5 of 6 NEM®I etc. 14 6.4 HIP&RIDGE SHINGLES: 6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles 11.5" Sealant and Seal-A-Ridge ArmorShield Ridge Cap (251. (292 mm) (25 mm) Sellante mm)Shingles shall comply with the GAF current Endufld'etancheite published instructions with a minimum two (2) Wa nails, minimum 3/8-inch head diameter, per , r. ' shingle and nominal 0.25-inch diameter beads of Henkel "Loctite PL S30 Roof & Flashing Sealant". (305 mm) Nail { Clavo 6 5/8°-7 5/8" Clouer (168-194 mm) 12" (305 mm) 6.4.2 Installation of Timbertex Premium Ridge Cap 11.51 Shingles shall comply with GAF current 1" (292 mm) 1^ lant Selalante published instructions with a minimum two (2) (25Mm) (25 mm) Enduitd'6tanchdit8 nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn "NP1 Gun Grade Polyurethane Sealant" or Henkel "PL Roofing and Flashing Sealant". Nall Clavo 12" Clouer (305 mm) 9" (229 mm) 12" (305 mm) 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com - END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 01506.01.08-R24 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-1122 GAF Asphalt Roof Shingles Revision 24:04/12/2019 Page 6 of 6