HomeMy WebLinkAboutProduct Approval, metal 10/8/2019 Rorida Building Code Online
�• ��"h ���xHi5i 1 �A"tti :� �a, itt`�{ro � a�� NrFt �m t 5 L'"`§ �'�� a�}h� � '3,�i. I �` �3.^�.: p'Yr�3��i�'.'�v+ �p � �@�'a�;, {,VY/Fss v���r'�
BCIS Home { lag In j User Registration ! Hot Topics j Submit Surcharge I Stats&Facts i Publications Contact Us I BQS Site Map I Links i Search
iv,f1 Product Approval
i ?.USER:Public User
I
Product Annrnv l Menu>Pro or A plication Search>Application fist>Application Detail
RECEIVED
FL17022-R7
FL# OCT 15 1019
A (cation Type Revision
I
Code Version 2017 ermitting Department
Application Status Approved St. Lucie County
i
Comments 08/18/2017v,date reapply 08/21/17
Product Manufacturer Extreme Metal Fabricators,LLC
Address/Phone/Email 2160 SW Poma Drive File Copy
Palm City,FL 34990
(772)872-8034
Rvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com Technical Representative Richard McKuhen VIEAiWED FOR
,
Address/Phone/Email 2160 SW Poma Drive CODE COMPLIANCE
Palm City,FL 34990
rich) 872-8034 ST. I t e C I E C®U TY richard@emfab.net ate, iie�+'o.o rQqe_po i (0 TO 6!OCC l
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
I
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
- Evaluation Report-Hardcopy Received j
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R.Priest,P.E.
Validation Checklist- Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pg[f
Referenced Standard and Year(of Standard) Standard _ Year
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
I
https://www.floridabuilding.org/pr/pr app otl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 1/3
10/8/2019 Florida Building Code Online
I
Product Approval Method Method 1 Opti l n D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08/28/2017
Date Approved 10/10/2017
Summary of Products
I
FL# Model,Number or Name Description
17022.1 1-"5V Crimp" (R6) 26 Gauge steel,3/8"rib height,24"wide lapped roo I anel
mechanically attached to 15/32"plywood or Wood Dec ith
fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.1 5 V CRIMP ssrpdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf
a I in compliance with the installation method listed in Created by Independent Third Part�Yes
this report a ode sections of FBC. Refer to
manufacturer's installation instructions.
17022.2 2-"5V Crimp"(R6) 0.032"Aluminum,3/8"Rib height,21"wide lapped roof panel,
mechanically attached to 15/32"plywood or Wood Dick with
exposed fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssrpdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0 032 ALUML-asr odf
assembly in compliance with the installation method listed in Created by Independent Third Party:Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
i
17022.3 3-"1.5"Mechanical Seam" (115) 1.5"rib height,16"wide,24 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ:Yes seam 24ga ssrpdf
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other: Refer to evaluation report for conditions and limitations Evaluation Reports
of use.Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
method listed in this report and applicable code sections of seam 24ga ssr df
FBC.Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes
i
17022.4 4-"1.5"Mechanical Seam"(115) 1.5"rib height,16"wide,0.032"aluminum,standing seam roof
panel mechanically attached to 15/32"plywood or Wood Deck
with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ:Yes ALUMINUM ssr.pd
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes
Other: Refer to evaluation report for conditions and limitations Evaluation Reports
of use.Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
method listed in this report and applicable code sections of ALUMINUM ssr.pdf-
FBC.Refer to manufacturer's installation instructions. Created by Independent Third Party:Yes
i
17022.5 5-"1 in. Nail Strip"(115) 1"rib height,16"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssrpdf
of use.Install the assembly in compliance with the installation Created by Independent Third Party:Yes
I
httpsJ/wwwfloridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv2aBOpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3dio6d 2/3
10/8/2019 Florida Building Code Online
method listed in this report and applicable code sections of
FBC.Refer to manufacturer's installation instructions.
17022.6 6-"1 in. Nail Strip"(115) 1"rib height,16"wide,0.032"aluminum,standing seam roof
panel mechanically attached to attached to 15/32"plywood or
Wood Deck with fasteners,
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.0321
Approved for use outside HVHZ:Yes ALUM ssrpd
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and limitations Evaluation Reports
of use.Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
method listed in this report and applicable code sections of ALUM ssr.pdf
FBC.Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes
17022.7 7-"1.5 in. Nail Strip"(115) 1.5"rib height,19"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 H FL 17022.7 1.5 Nail Strip 26GA ssrlpdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party: Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
of use.Install the assembly in compliance with the installation Created by Independent Third Party:Yes
method listed in this report and applicable code sections of
FBC.Refer to manufacturer's installation instructions.
17022.8 8-"EMAX Rib" (115) 29 gauge steel,lapped roof panel mechanically attached to
15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 177022.8 EMAX Rib aff_,2 f
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 177022.8 EMAX Rib ssrodf
of use.Install the assembly in compliance with the installation Created by Independent Third Party: Yes
method listed in this report and applicable code sections of
FBC.Refer to manufacturer's installation instructions.
17022.9 9-"PBR MAX"(115) 26 gauge steel,lapped roof panel mechanically attached to
15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.9 PBR RIB ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.9 PBR RIB ssr.pdf
of use.Install the assembly in compliance with the installation Created by Independent Third Party:Yes
method listed in this report and applicable code sections of
FBC.Refer to manufacturer's installation instructions.
Oach fdext
I
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an WEED employer.Co ri ht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
_ I
q M
Credit Card.
Safe
I
httpsJ/www.floridabuilding.org/pr/pr app d.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 313
}
1 V
y .. .
Extr' me Metal
_ • •uctAerit• • -Fabricators,
2160 SW Poma Drive'
Palm City, Fl. 34990
272)872=8034
• • • ` • • • • s 1 • NON HVRZ
Compliant with Florida Building Code 2017 (61 ed.)
Compliant with Florida Product Approval Rule#61G20-3
Compliant: Keystone Certifications
I
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood
Deck w/min.0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1 (Method 1 Attachment):#9 x 1-1/2" Hex-Washer Head wood screw* to penetrate
3/16" min.thru deck or 5/8"embedment into wood plank. (*or sufficient length to meet
i
requirements)
Fastener 2 (Method 2,3, &4 Attachment): #10 x 1-1/2" Hex-Washer Head wood screw*�to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance wit FB e . 07.
Se astener attachment speciFcations above
Install Details: Table A Allowable ads METHOD METHOD 2 METHOD 3 . METHOD.4
DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF 7228 PSF
ROW SPACING_. 16"o,C. 16"D.C. _ . , 8"D.C. 6"oll.c.
FASTENER SPACING (ALONG Panel widt 12"o•c. 12"O.C. 12"o.c. 12"o.c.
FASTENER SIZE #9 7 #10 #10 #10
Reference Data: ARCHITECTURAL TESTING,INC.TST ID#:1527
UL 580-06& 1897-041 Test Report X893.01-450-18 05/02/24
Test Report F3366.01-450-18 12/18/25
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equiva/entto test standard UL 1897-1I�r *Design pressure margin ofsafety2:1
Locke Bowden,P.E.does not have,not will acquire a financial Iniq aMcg q�►m� faduring or distributing products
% o .t ��
under this evaluation. �.
Locke Bowden,P.E.is not owned,operated,or controlled by any coiApar(#;jmh41df4tures,or distributing products under this
report.
�� ;71'7 S� 4�
►p�/{A`�•([.,,`r) .. i
i
1
FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details
' Limitations:
1. Underlayment to be compliance with current Florida Building Code(FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed.,and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61620-3.Compliance Method: 1-D
' 4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.
I
Fasteners-
49 x 1-112'Min.or
410■1-1/2"Min.perTable A'for Row 5-V ainip Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
� _�1/��`. i��,z,...\vim�::\✓_:����..�:�;/�1,.l.-
Deck:
Wooed plank or greater Plywood,Or
-
24-
318"
OPMMALSTRIAMOt S
Panel Profile
Nominal 12" Nominal 12"
O.C. O.G.
i
Fasten
#9 X 1-1/2"Min. or #10 X 1-1/2"Min.per
Table"A" Hex Washer Head Screw
Spaced 12"o.c.across the Panel Width
Panel Refer to Table"A"for Spacing Along Panel
Overlap Length
Deck-15/32"or greater
Plywood,or
-Wood plank
I
' I