HomeMy WebLinkAboutDesign Pressure Calcs Cot OCT 16 `I019 Ittin9 t)CbuntY nt perm St.Lucie S 'H U T T E R C n R P O R AT t Q N 12980 SE SUZANNE DRIVE. HOBE SOUND, FL 33455 PH: (772)-545-3300 FAX: (772)-545-3297 Property Information Building Information Owner: Ellie Wheeler Wind Zone: 170 MPH. Address: 86 N EI Mar Dr Exposure Category: D Jensen Beach, FL 34997 Minimum Building Dimension: 35 ft. Mean Roof Height: 15 ft. Risk Category: 11 Design Pressure Calculations p � g (� ) IF .g (� ) O LP � �gative O enm Location Device Device Device Max Positive Max Ne Number Zone Width in Hey ht in Elevation ft Pressure s Pressure(psf) 11 1 End ill 89 7 40.1 -49.9 ------ -- ....................... ---........_.................— -....__..... ..........--....-........................-----_.....-....._................ 2 Int ] 11 57 7 41.5 -45,.3 - 3 — --Int ---- - 45 - -- - 89 --- -- -- 7 ----- 42.8 - --------- _46.7 --- - I i I I i I i i I i I Prepared in accordance wilh:ASCE 7-10,Chapter 30. Wind Loads-Comrponews and Cladding.6th Edition(2017)Florida Building Code. Page 1 of I i Identification Schedule for Opening Protective Device or System - - —-(Tlte follcrwing-nrirtinrunr info»ncrrion curd-inspecriort-q/_'r/ae-pron/v]sed-irrsralluriorr,opetriug !zr_orectii c de-ice orsysterrt)____ __ Address: 86 N E1 Mar Dr, Jensen Beach, FL 34997 TypeofStructure: PERMIT#: Dev. Device Device Approval k� w Shutter Shutter Anchor # Type Manufacturer PP /� �� �I � - Width Height A14I Spacing �^ 1. _ Panel EMS _ FL 1 1964-R4_ -49.9 89_ 111 89 °"'S°'"'Sr' 9-12 Frame/Concrete 2. Panel EMS FL l 1964-R4 -45.3 57 111 57 Tapcon 9 Concrete . 3. Panel EMS FL 11964-R4 -46.7 89 45 89 T"p"'"'Sofid S" 9-12 Concrete