Loading...
HomeMy WebLinkAboutProduct Approval C: Business & Professional Regulation' r SCIS Home :tag In ! User Rag Lttration 1 Hot Topic ! Submit Surcharge € Stets&Facts Publications i contact us# acts Site Map unim Search i �0f1da @; Product Approval USER:Public User Product Avoroval Menu>product or Application Search>Application List>Application Detail FL# FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v.date reapply 08/21/17 Archived p Product Manufacturer Extreme Metal Fabricators,LLC Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 �1 {772} 8034 ' flvalidatlotion@yahoo.com Authorized Signature Richard McKuhen RE flvaiidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Emali 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 hardoemMb. REVIEWED FOR richard@emfab.net Quality Assurance Representative CODE COMPLIANCE Address/Phone/Email ST. L U C y E CO TY Category Roofing wl6®CC o x7/14' Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R.Priest,P.E. Cf Validation Checklist-Hardcopy Received Certificate of Independence 1117022 R7 COI FL 17022.1 5 V CRIMP ssr.odf Referenced Standard and Year(of Standard) Rgindard Year TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products Fl.# Model,Number or Name Description 17022.1 1-"5V Crimp"(116) 26 Gauge steel,3/8"rib height,24"wide lapped roof panel mechanically attached to 15/32"plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions.Install the. FL17022 R7 AE FL 17022.1 5 V CRIMP ssr odf assembly in compliance with the installation method listed in Created by Independent Third Party:Yes this report and applicable code sections of FBC.Refer to manufacturer's installation Instructions. 17022.2 2-"5V Crimp"(116) 0.032"Aluminum,3/8"Rib height,21"wide lapped roof panel,mechanically attached to 15/32"plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure.+N/A/-Table A Evaluation Reports Other.Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf assembly in compliance with the installation method listed In Created by Independent Third Party:Yes this report and applicable code sections of FBC.Refer to manufacturer's Installation Instructions. 17022.3 3-"1.5"Mechanical Seam"(115) 1.5"rib height,16"wide,24 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use In HVHZ:No FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ:Yes seam 24ga ssr.odf Impact Resistant:No Verified By:Locke Bowden,P.E.49704 Design Pressure:+N/AJ-Table A Created by Independent Third Party:Yes Other.Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with the FL17022 R7 AE EL 17022.3 1.5 MECHANICAL Installation method listed in this report and applicable code seam 24ga ssr.odf sections of FBC.Refer to manufacturer's Installation Created by Independent Third Party:Yes Instructions. 17022.4 4-"1.5"Mechanical Seam"(115) 1.5"rib height,16"wide,0.032"aluminum,standing seam roof panel mechanically attached to 15/32"plywood or Wood Deck with clips and fasteners. Limits of Use Installation Instructions Approved for use In HVHZ:No Ft 17022 R7 II FL 17022,4 MECHANCIAL SEAM Approved for use outside HVHZ:Yes ALUMINUM ssr.odf Impact Resistant:No Verified By:Locke Bowden,P.E.49704 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other:Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM installation method listed in this report and applicable code ALUMINUM ssr.odf sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes instructions. 17022.5 5-"1 In.Nail Strip"(115) 1"rib height,16"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 7077 R7 II FL 17022.5 1.0 NAILSTRIP ssr.odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,A.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 7022 R7 AE FL 17022.5 2.0 NAILSTRIP ssr.odf limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes Installation method listed In this report and applicable code sections of FBC.Refer to manufacturer's Installation Instructions. 17022.6 5-"1 In.Nail Strip"(115) 1"rib height,16"wide,0.032"aluminum,standing seam roof panel mechanically attached to attached to 15/32"plywood or Wood Deck with fasteners, Limits of Use Installation Instructions Approved for use In HVHZ:No FL17022 R7 I1 FL 17022.6 1.0 NAIL STRIP 0.032 Approved for use outside HVHZ:Yes ALUM ssr.odf Impact Resistant:No Verified By:Locke Bowden,P.E.49704 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other:Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with the EL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 Installation method listed in this report and applicable code ALUM ssr.Ddf sections of FBC.Refer to manufacturer's Installation Created by Independent Third Party:Yes Instructions. 17022.7 7-"1.5 in.Nail Strip"(115) 1.5"rib height,19"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck With fasteners. Limits of Use Installation Instructions Approved for use In HVHZ:No FL17022 R7 11 FL 17022.7 1.5 Nall Strip 260A ssr.odf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.odf limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes Installation method listed in this report and applicable code sections of FBC.Refer to manufacturer's installation instructlons. 17022.8 8-"EMAX Rib"(115) 29 gauge steel,lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use In HVHZ:No FL17022 R7 II FL 177022.8 EMAX Rib ssr.Ddf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE.FL 177022.8 EMAX Rib ssr odf limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes Installation method listed In this report and applicable code sections of FBC.Refer to manufacturers installation Instructions. 17022.9 9-"PBR MAX"(RS) 26 gauge steel,lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.9 PBR RIB ssr.Ddf Approved for use outside HVHZ:Yes Verified.By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.9 PBR RIB ssr odf limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes Installation method listed in this report and applicable code sections of FBC.Refer to manufacturer's installation Instructions. Contact us;;2801 Blair Stone Read,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovrdeht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you de not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.U you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click�e. Product Approval Accepts: ®®® eCfia. Credit Card Safe l :Product Report Manufacturer: Extreme Metal Fabricators, LLC. , 2160 SW Poma Drive Palm City, FL 34990 772.187240.3.4. Florida Product Approval # 17022.S 1" Nailstrip NON RVNZ Compliant with Florida Building Code 2017 (611 ed.) i Compliant with Florida Product Approval Rule#61G20-3 Compliant: Keystone Certifications i Product: l"Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32"plywood or i Wood Deck w/0.42 specific gravity with 16"Coverage(Max.) Rib Height 1" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" (min.)Pancake Head Wood Screw to penetrate 3/16" (min.)thru bottom of support. Adhesive/Sealant : Bostik 9151 Chem-Chalk one component,polyurethane adhesive with 3/16"continuous bead application along base of male rib vertical flange at each panel seam. Underlayment:To be compliant with FBC Sec 1507.1.1 Slope:Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 DESIGN PRESSURE* -86 PSF Main field -97.25 PSF Perimeter I.......... —�. _. FASTENER SPACING 6"O.C. 6" O.C. SEAM ADHESIVE Not required 3/16"continuous bead (see details Reference Data: ARCHITECTURAL TESTING,INC.TST ID#: 1527 UL 580-06&UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen#1&#2 EQUIVALENCY:UL1897-04 is equivalent to Test Standard UL1897-12. *Design Pressure margin of safe 2:1 Certificate of independence: Locke Bowden,P.E.does not have,not will acquire a financial iipnasl�ny,company manufacturing or distributing products under this evaluation. ��•``�C 1). 13c;y� Locke Bowden,P.E.is not owned,operated,or contrail Y�,,• R�1• jian���cturer,or distributing products under this y • f'l�'"i report. • + • x • • seal STATE OF y r•• Ft ORIOF'.•• a,.' • Fs••....• - c� •`°���3' )NAL�• ; Y Limitations: 1.Underlayment to be compliance with current Florida Building Code(FBC)2017 60,ed.. 2.Minimum slope to be compliant with Florida Building Code 2017 6t'ed.,and per with Manufacturer's installation reference. 3.Products are compliant for State of Florida product approval per Rule 61 G20-3.Compliance Method:1-D 4.Engineering analysis for'project specific approval by local authorities wfjurisdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 61h ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty,installation,recommended product use outside of this report. FL 17022.5 1.0 Nail Strip(26GA Steel),16"Wide Roof Panel-Details 3/4� Panel Profile 16"o.c. Deck: -15/32"or greater Plywood, -Wood plank -Integral Snap Lock For METHOD 2: Apply 3116"Bead Bostik 915114 Sealant Continuous Along Male Rib Vertical Flange Fastener #10 x 1"Min. per Table"A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) FL 17022.5 1.0 Nail Strip(26GA Steel),16"Wide Roof Panel-Details Fastener #10 x 1"Min. per Table"A" Pancake Head Wood Screw 1"Nail Strip Roof Panel f v � m n f� Seam Adhesive Application: Deck: For Method 2 15/32"or greater Plywood,or Apply 3/16"Bead Bostik 915 TM Sealant -Wood plank Continuous Along Male Rib Vertical Flange (Refer to Table"A') Isometric View