Loading...
HomeMy WebLinkAboutProduct Approval (2) Usinesst-Professi. 'nil acts Home Login rZ lodda Uft�RcqiAnulon Hot submits.mtug, StatsikRicto PublIcuttonr Conbactils oassnemp unks seaft r ' Product'Apprawai useR:Public User EWL91.82212--8LMe-gs>ESM-d-ct 01 App$0flun Searct#>ARWc-00y tist>AppUention 00211 FL.# R5259-R28 Application Type Revision Code Version 2017 Application Status Approved Comments Archived El Product Manufacturer POLYGLASS USA Address/Phone/Emall 1111 W.Newport Center Drive Deerfield Beach,Fl-33442 (954)233-1330 Ext 242 malpert@polyglass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative Maury Alpert Address/Phone/einall 1111 W.Newport Center Drive Deerfield Beach,FL.33442 (912)429-8610 MAtpert@polyglass.com REVIEWED FOR Quality Assurance Representative Ariel Lender AddressIPhone/Emall 1111 W.Newport Center Drive CODE COMPLIANCE Deerfield Beach,FL.33442 (954)233-I250 ST. LUCIE COUNTY ALender@pol/glass.com Category Roofing BOCC Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nlemlnen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/13/2021 Validated By John W.Knezevich,PE 0 Validation Checklist-Hardcopy Received Certificate of Independence FL5259 R28 CO1-201801 COX NIEMINEN.pd Referenced Standard and Year(of Standard) Sitandand Ye r ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6164 2011 ASTM D6272 2011 FM 4474 2011 FRSAfTRX April 2012 2012 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method'1 Option D Date Submitted 01/24/2018 Date Validated 01/29)2018 Date Pending FBC Approval 01/30/2018 Date Approved 04/10/2018 SummarV of Products FL# Model,Number or Name Description 5259.1 PDlyglass Roof Roofing underiayments Underlayments Limits of Use Installation Instructions Approved for use In HVHZ.No FLS259 R28 II 2018 01 FINAL ER EDLYGLASS UNPERLAYMENTS 5254 Approved for use outside HVHZ:Yes R28.12df Impact Resistant:N/A Verified By;Robert Nleminen PE-59166 Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes Other.1.)The design pressure In this Evaluation Reports application relates to one particular EL5259_R28 AE 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS 259 underlayment system(over concrete deck) R28.edf for use under foam-on the systems(where Created by Independent Third Party;Yes the underlayment forms part of the load- path).Refer to ER Section 5.6.4 for other systems,other deck types and associated maximum design pressures.2.)Refer to ER Section 5 for other limits of use, ® RQ contact Us t:2402 elalr Stone Road,Taliahssseu_ Fl MaA phone:8504824 the State of Rarlda Is an AVEEO employer.1002yright 2007-7013 state,of Florida,::Privacy Statement;;Accessi lied statement::Refund Statement Under Florida low,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do net send electronic mall to this amity.Instead,contact the al0rs by phone or by tradldonal mall.If you have any questions,please contact 850.487.2395.*pursuant to Section 455.275(1), Ronda Statutes,effective October,1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.the emalts provided maybe used for o0kial communkadon with the Umnsee.However emall addresses are public reared.n you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the pubUe To determine ifyou am a licensee under Chapter455,F.S.,please dtckb . Product Approval Aceaptm ®rI R- ® Credit Card Safe i i NEMO(etc. Certificate ofAut6orhnUon#32455 353 Christian Street,Unit#13 ISO Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Polyglass USA,inc. Evaluation Report P12060.02.09-1124 1111 West Newport Center Drive FL5259-R28 Deerfield Beach,FL 33442 Date of Issuance:02/24/2009 ' 24 (954)233-1230 Revision 24:01 2018/ / SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6u' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the o the production facility Iodations . NEMO etc. requires a complete review of this the Quality Assurance r q P product(s), Q ty p fi► ( ) Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. ' INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: ���,,sv + 48 .1' Robert J.M.Nieminen,P.E. - ''}� z.. �q=_-''raw: The facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No.59166,Florida DCA ANEl983 n,E`s �- `E q� F.E.on 01/24/2018.This does not serve as an electronically signeddocument' CER11RCAMON OF INDEPENDENCE: 1. NEM01etc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. MEMO I etc.Is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nleminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING COMPONENT EVALUATION: I. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments,as produced by Polyglass USA,Inc., have demonstrated compliance with the following sections of the 6u'Edition(2017)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations J Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1.504.3.1 Wind uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3(1507.1.1 Physical Properties ASTM D226 2009 1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: End Examination Reference Date FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000 PRI(TST5878) Physical Properties PRIO1211 04/08/2002 PRI(TST5878) Physical Properties PUSA005-02-01 01/31/2002 PRI(TST 5878) Physical Properties PUSA-013-02 01 12/23/2002 PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI(TST 5878)' Physical Properties PUSA-013-02-03 12/23/2002 PRI(TST5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI(7ST5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI(TST5878) Physical Properties PUSA-033-02-01 01/12/2005 PRI(TST5878) Physical Properties PUSA 035-02-01 09/29/2006 PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI(TS75878) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI(TST5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI(TST 2508) Physical Properties JX201-17A 04/01/2008 MTI(TST 2508) Physical Properties RX14E8A 01/29/2009 ERD(TST 6049) Physi®I Properties 11752.09.99-1 02/08/2000 ERD('TST 6049) Wind Uplift 11757.08.01-1 08/13(2001 ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD tM6049) Physical Properties 02200.07.03 07/14/2003 ERD(TST 6049) Wind Uplift PIT40.o1.07 01/04/2007 ERD(TST 6049) Physica I Properties P5110.04.07-1 04/11/2007 ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD(TST-6049) Physical Properties .P13450.08.09 08/13/2009 ERD(TST 6049) Wind Uplift P30540.11.09-RI 11(30/2009 ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD(TST 6049) Wind Uplift P11030.11.09-2 W30/2009 ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD(TST GM) Physical Properties P33360.06.10 06/25/2010 ERD(TST6049) Physical Properties P33370.03.11 03/02/2011 ERD(TSTfi049) Physical Properties P33370.04.11 04/26/2011 ERD(TST6049) Physical Properties P37300.10.13. 10/19/2011 NEMO Etc,LLC. Evaluation Report P12060.02.09-RZ4 CergrtWW ofAuthorimtton A32455. 6 EDITION 12017)FSC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments,(954)233-1230 Revision 24:01/24/2019 Page 2 of 14 ONEmoletc. Entity Examination Reference Date ERD(TST 6049) Physical Properties P40390.08.12-1 08/05/2012 ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD(W 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD(TST 6049) Wind Uplift 11757.04.01-1-RI 04/30/2013 ERD(TST 6049) Wind Uplift P41630.08.13 08/0612013 ERD(TST 6049) Wind Uplift P12751.05.03-R1 11/26/2033 ERD(TST 6049) Wind Uplift P11791.11.03-RI 11/26/2013 ERD(TST 6049) Physical Properties P4S270.45.14 05/12/2014 ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD CW 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD(TST 6049) Physical Properties 6021109.14-6 09/08/2014 ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD CW 6049) Physical Properties P43290.10.14 10/17/2014 ERD(TST 6049) Physical Properties PLYG-SC7550.03.I5 03/24/2015 ERD(T-ST 6049) Physical Properties P40390.04.15 04/03/2015 ERD(TST 6049) Physical Properties P44360.10.14-RI 05/1812015 ERD(TST 6049) Physical Properties PLYG-SC8080.05.15-1 M/20/2015 ERD M 6049) Wind Uplift PLYG-SC8905.05.16-2 05A7/2M6 ERD(W 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/22/2016 ERD(TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016 ERD(W6049) Physical Properties PLYG-SC11900.03.27 03110/2017 ERD(TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017 ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/02/2014 Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01P2/2015 Polyglass USA Manufacturing Affidavit Products Current 02/28/2009 Polyglass USA P/L Affidavit Mule-Hide Cross 1% 03/01/2008 Polyglass USA Materials Affidavit Pollystick SA Compound 08f18/2011 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.10/05/2018 4. PRODUCT DESCRIPTION: 4. 4.1.1 Elastobase Is a fiberglass reinforced,SBS modified bitumen base sheet. 4.12 Elastobase P is a polyester-reinforced,SHS modified bitumen base sheet. 4.1.3 Polyglass 62 Base is a fiberglass-reinforced,asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet. 4.2.1 Pollysfick IVM or PoIVs;tIck MTS PLUS Is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,surfaced with polyolefinic film surface,meets FRSA/TRI April 2012. 4.2.2 PoWick IR Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an aggregate surface;meets ASTM D1970. 4.2.3 Pollystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,With a polyester fabric surface;meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Cert0kaft OfAtitharkWan#32455 fiTM EDITION(20,17)FOC NON44VHZ EVALUATION n5259-R28 Polyglass Roof Underlayments,(954)233-I230 Revision 24:02/24f2018 Page 3 of 24 ONEMO eft. 4.2.4 Polystick TU P Is a nominal 130-mll thick rubberized asphalt waterproofing membrane, glass-ftber/polyester reinforced,with a granular surface,meets FRSA/TRI April 2012. 4.2.5 PolvsUck TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface;meets ASTM D1970 and FRSA/TRl April 2012. 4.2.6 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA APP Cap Sheet(FR) are polyester . reinforced,APP modified bitumen cap sheets,meet FRSA/TRI April 2012. 4.2.7 Polystick Dual PW14 is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970. 4.2.8 Polystick rile ProM is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970 and FRSA/TRI April 2012. 4.2.9 Polystick MUX is a nominal 54-mil thick-dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polypropylene film surface,meets AC188 and physical requirements of ASTM D1970(See Section 4:3." Mechanically Fasfeiiei!°.omit/cid ed 4.3.1 Elastoflex 6 7U Is a polyester reinforced, modified bitumen the underlayment composed of a sand-surfaced SBS modified bitumen back-side and granule-surfaced APP modified bitumen top-side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M)in the"Single Ply System"from FRSAfrRI April 2012 (04-12)beneath mechanically fastened the roof systems or Not Asphalt applied "Cap Sheer in the"Two Ply System-from FRSA/TRI April 2012(0412)beneath mechanically fastened or adhered file roof systems. 4.3.2 Bastoflex S6 6 and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164. Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to"Mineral Surfabe Roll Roofing" (ASTM D6380, Class M)in the"Single Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened the roof systems. Elastoflex S6 G Is for use as an alternate to Hot Asphalt applied"Cap Sheet"in the'Two Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the 'Two Ply System"from FRSA/rRI April 2012(0412) beneath mechanically fastened tile roof systems. 4.3.3 Polyflex 6 and Polyflex 6 FR are polyester reinforced, APP modified bitumen n cap sheets; meet ASTM D6222. Polyflex 6 is for use as an alternate to Heat Applied"Cap Sheer in the'Two Ply System"from FRSA/TRI April 2012 (0442)beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat Applied"Cap Sheer in the'Two Ply System"from FRSA/TRI April 2012(0412) beneath mechanically fastened tile roof systems. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEW I etc. nor Robert Nleminen, P.E.are, In any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, Is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report Is not for use in the HVHZ. 5.3 Fire Classification Is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. S.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product Is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. MEMO ETC,U.C. Evaluation Report P12060.02-09-RZ4 ONVftcate ofAuthorkatlan M455 EDMON(2017)HIC NON-14VHZ EVALUATION FLMS-R28 Polyglass Roof underfayments;(954)233-1230 Revision 24:01/24/2018 Page 4 of 14 ONEMOjetc. 5.5 Allowable Roof Covers: .. - ;';;. ::<TA9LlE Z�II;OOF..COVER•O,RTIONS. ,nii: ;u::� under went As haitShin les Nall-On Tile -Foam-OnTile Metal Wood Shakes Slate &Shingles Elastobase Yes Yes(ease sheet n2plysystem) (Base sheet n25Yes Yes Yes 2-ply Elastobase P Yes Yes Yes Yes Yes Yes (Base Sheet in 2-01 system) (Base Sheet In 2-0y system) PolygfassGZBase No Yes Yes No No No (Base sheet int-pivsystem) (Base sheet int-plysynem) PolyglassAPPBase No Yes Yes No No No (Base Sheet ln2-pN system) (Base Sheetin2-plysymm) Polystick MTS or MTS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes PolystickTU P . No Yes Yes(See 5.5.1) No No No Polystick TU Plus Yes Yes Yes(See 55.1) Yes Yes Yes PolystickTUMax No Yes' Yes(See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes PolystickTile Pro Yes Yes Yes(See 5.5.1) Yes Yes Yes PoWckMU-X Yes No No Yes Yes Yes Elastoflex S6 G Yes Yes Yes(See 5.5.1) No Yes Yes ElastoflexS5GFR Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes(See 55.1) No Yes Yes Palyflex G Yes Yes Yes(See 55.1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes(See 55.1) No Yes Yes Mule-Hide SA-APP Cap Sheet Yes Yes Yes(See 55.1) No Yes Yes or SA-APP Cap Sheet(FR) 5.5.1 "Foam-0n Tlle"(s limited to use of the following Approved tile adhesives/underlayment combinations. Taei�;=A:ALLoilyge[E TILE Al)ll#E511/E/�DIDERLA'(MEIQ�COtU191NgT10N51: Adhesive . Florida Product Underlayments Approval DAP Foam Touch'n Seal StormBond Roof FL14506 Polystick TU Plus,Polystick TU Max Tile Adhesive Dow TileBond— FL22525 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro, ICP Adhesives Polyset®AH-160 FL6332 Elastaflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro, ICP Adhesives Polyset®RTA-1 FL6276 Elastoflex G TU,Elestoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) 1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval far overturning Moment Resistance Performance- NEMOETC,U.C. Evaluation Report P12060.02.09-R24 Certfflcatc ofAutharitown 032453 dM EDITION(2017)FBC NON-HVHZ EVALUATION Revision 24:01/24/2018 Polygla55 Roof Underlayments)(954)233-1230 Page 5 of 14 ONEMOletc. 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Polystick(all variations),Dual Pro,Tile Pro,Polyflex SAP or SAP FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)self-adhered to: ➢ New untreated plywood;ASTM D41 primed new untreated plywood;Existing plywood;ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note:Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: D ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch-applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond-to-Insulation: Polystick(all variations),Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered to: ➢ ASTM C1289, Type ll, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard;Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. Polyflex G or Polyflex G FR torch-applied to: A ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on the systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underiayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Laver: Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)Dual Pro or Tile Pro self-adhered to: ➢ ASTM D226,Type I or 11 felt;Elastobase;Elastobase P or Mule-Hide Nail Base. Elastoflex G TU,Elastoflex S6 G or Elastaflex S6 G FR in hot asphalt to: ➢ ASTM D226,Type I or II felt,Elastobase;Elastobase P,Mule-Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch-applied to: ➢ Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For Installations under foam-on file systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012(0412),Appendix A,Table 1,or as listed in Section 5.6.4 herein,or as tested in accordance with FBC Section 1504.3.1. NEMO ETC,LLC. Evaluation Report P12060.02.09-RZ4 rertfimffi ofAutharkanon#32455 6m EDITION(2017)FBC NON-HVHZ EVALUA71ON FL5259-R28 Polyglass Roof Underlaymerds;(954)233-1230 Revision 24:01/24/2018 Page 6 of 14 ONEMOIetc. 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on file systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 15049 has already been applied).Refer to FRSA/TRI April 2012(04- 12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #2 Maximum Design Pressure=-97.5 psf: Deck: Min.15/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 19"ring shank nails through 32 ga.,1-518m diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure=-105 nsf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 - Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,,Polyflex SAP,Poiyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x IX"ring shank nails through 32 ga.,1-5/9"diameter tin caps spaced 12-Inch o.c. #4 Maximum Design Pressure=-135 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)P6100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Joints: Min.flinch wide strips of Elastoflex SAV overall plywood joints. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #5 Maximum Design Pressure=-315 IDsf Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Tile P%Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and M ule-Hide SA-APP Cap Sheet(FR),self-adhered. #6 Maximum Design Pressure=-622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer. PG100orASTMD41 Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #7 Maximum Design Pressure=-30.0 psf*: Deck- Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastabase or Mule-Hide Nail Base(poly film top surface) Fasteners: 11 ga.x ti25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-Inch o.c.at the 3-inch wide side laps and 64nch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. NEW ETC,I.I.C. Evaluation Report P12060.02.09-R24 certtff—ofaurhorrzauon#32455 6'H EDITION(2037)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments,(954)233-1230 Revision 24:02/24/2018 Page 7 of 14 ONEMO etc. #8 Maximum Design Pressure=-37.5 Dsf*: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 64nch o c.at the 3-inch wide side laps and 6-Inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #9 Maximum Design Pressure=-37.5 psf*: Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)ortwo(2)layers ASTM D226,Type 11 felt Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch ox.at the 3-inch wide side laps and 12-Inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt #10 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)layer ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8­41nch diameter tin caps Spacing: flinch o.c.at the 24nch wide side laps and flinch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Palystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt #11 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. . Base Sheet: Two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin raps Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt #12 Maximum Design Pressure=-45 psi: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Havinglurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 94nch o.c.at the 2-inch wide side laps and 18-Inch o.c.attwo(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #13 Maximum Design Pressure=-52.5 psi. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.atthe 2-inch wide side laps and 12-inch o.c.attwo(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied. #14 Maximum Design Pressure=-525 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 34nch wide side laps and 64nch o.c at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. NEMO ETC,LLC. Evaluation Report P12b60.02.09-1124 Certittcate ofAutharhntbn#32455 EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 8 of 14 ONEMO etc. #15 Maximum Design Pressure=-52.5 psf: Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Having jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied rap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3Anch wide side laps and 6-inch o.c.at four.(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #16 Maximum Design Pressure=-60 Psf: Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority Havinglurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps Spacing: 8-Inch o.c.at the 4-Inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex 56 6,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #17 Maximum Design Pressure=-60 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #18 Maximum Design Pressure=-67.5 Psf: Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base{requires use of torch-applied underlayment) Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 84nch o.c.at the 4-inch wide side laps and 84nch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mapping of hot asphalt or torch-applied or Polyflex G,torch- applied. #19 Maximum Design Pressure=-75 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of Porch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 34nch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c.at the 4-inch wide side laps and 104nch o.c.at three(3)equally spaced staggered center rows. Underlayment Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch- applied. #20 Maximum Design Pressure=-90 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface far hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 64nch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastaflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #21 Maximum Design Pressure=-90 DO: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c at the 44nch wide side laps and 6-inch o.c at three(3)equally spaced staggered center rows. Underlayment Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hat asphalt or Polyflex G,torch-applied. #22 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having.lurisdlction. Base Sheet: Elastobase(sanded tap surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 CerbTwte ofAuftda Bon#32455 6EDITION(2017)FBC NON-HVHZ EVALUATION FLM9-RZB Polyglass Roof Underlayments;(954)233-1230 Revision 24:02124/2018 Page 9 of 14 ONEMOletc. #23 Maximum Design Pressure=-90 Lwf Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass GZ Base or Polyglass APP Base(requires use of torch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c,at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch- applied. #24 Maximum Design Pressure=-97.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.254nch x 3/8-Inch head diameter annular ring shank roofing nails at 15/8-inch diameter tin caps Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #25 Maximum Design Pressure=-105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface fortorch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: &Inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #26 Maximum Design Pressure=-112.5 psf Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-Inch o.c at the flinch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin-caps Base Ply: Polystick MTS or Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick Tu Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #27 Maximum Design Pressure=-120 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface fortorch-applied cap) Fasteners: OMG#12 Standard Raofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing. 6-Inch o.c.at the flinch wide side laps and 6-inch o.c at five(5)equally spaced staggered center rows. underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #28 Maximum Design Pressure=-120 asf Deck: Min.35/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP orTrufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-Inch o.c.at the 44nch wide side laps and 6-inch c.c at five(5)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.1 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum Design Pressure of-45 psf. NENIO ETC,I.I.C. Evaluation Report P32060.02.09-R24 Certlftcate ofAuftrhaffan 932455 6TM EDITION(2012)FBc NON-HVHZ EVALUATION F15259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 10 of 14 ONEMOjetc. 5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(0412),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case,Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 2-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk's carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after Installation. Polystick MTS, MTS PLUS,TU P,TU Plus,TU Max, Dual Pro,Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180-days after installation. Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile,in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation,unless the prepared roof covering is to be adhesive-set the (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller,as set forth in Section 4.3,Note 1 of ASTM D1970-15,should be established as to slip resistance. 5.9 Tile Slippage Limitations(FRSA/TRI April 2012(0412)1: When loading roof tiles on the'underlayment in direct-deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. FgBL !2:.TILESI:IPRJCGE+iJMITATIGNSFOft: R�CiflD_EGKTILB�IY-STIONS.: Underlayment Tile Profile Staging Method Maximum Slope Flat 10-tile stack 7:12 Elastoflex G TU Lugged 8-tile stack(6 over 2) 6:12 Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack(4 over 2) 4.12 Flat 6-tlle stack(4 over 2) 5:12 Polystick MTS or MTS PLUS Lugged 6-tile stack(4 over 2) 4:12 PolystickTile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12 Flat 6-tile stack(4 over 2)or 10-tile stack 7:12 Polystick TU Max Lugged 6-tile stack(4 over 2) 7:12 Lugged 10-tile stack 6:12 Flat title stack(4 over 2) 6:12 Polystick TU P Lugged 6-tile stack(4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-tile stack(4 over 2) 7:12 Flat or Lugged 1GAIle stack 6:12 Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4:12 NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 QuIl mteofAuthor=10n#32455 6TMEDITION(2017)FOC NON-HVHZEVALUATION FL5259-R28 Polyglass Roof underlayments;(954)233-1230 Revision 24"01/24/2018 Page 11 of 14 ONEMOletc. 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6:3 Elastobase Elas#oa'sQ P: i Mele=Hide NailBasee`.: 6.3.1 Non-Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226,Type 11 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase,Elastobase P or Mule-Hide Nail Base may be covered with a layer of Poiystick,Polyflex SAP,Polyflex SA P FR, Mule-Hide SA APP Cap Sheet or SA-APP Cap Sheet (FR), self-adhered, Elastoflex 6 TU, Elastoflex S6 6 or Elastoflex S6 6 FR in hot asphalt or Polyflex 6 or Polyflex 6 FR,torch applied. Roof cover limitations are those are those associated with the top-layer underlayment,as set forth in Table 1, 6.3.2 Tile Applications: Elastobase,Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the"Iwo Ply System"from FRSAf MI April 2012(04-12). Reference is made to Table 1 and Section 5.6.4 herein,coupled with FRSA/TRI April 2012(04-12)Installation Manual. US:112 e`.'tU:P'TtJPlus TU Max f)ua�%Pb";�il�ePgQhMU-�t'or:PolyfteicSAP,•,PoCyfleX.SAPFit' 6.4 . Polystick,N1TS;.IVITSIRL ., .. X,. ;. r ,... :.,.,._.,. F ti . ..�.F,.... _ Mute-Hide SA=APRCajpSheetorlVlulNtdeSA=APR CapSfieet;� R) '_ :. 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970(except Polystick TU P)underlayment In FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers: All self-adhering materials,with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule- Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter metal disk or Simplex-type metal cap nail,at a minimum rate of 12"o.c. Polystick TU Plus should be back- nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back-nailed. All seal-lap seams (selvage laps) must be firmly rolled with a minimum 28 Ib. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro,align the edge of the tap sheet to the end of the glue pattern (the sheet will overlap the fabric). J view of ovelap Seam of Dual Pro and Tile Pro All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus SO Premium Modified Wet/Dry Cement or Polyglass PGS00 Modified Cement applied in between the application of the lap. Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys, or exposed roof to wall details NEMO ETC,LLC- Evaluation Report P12060.02.09-R24 Qrttfkate ofAurhorlmtran N32455 6m EDITION(2017)FBC NOWHVHZ EVAWATION FL5259 R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 12 of 14 ONEMOjetc. Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass P6500 Modified Cement to the area in need of repair,followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shalt be Installed In a water shedding manner. All Po(ystick membranes shall be Installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-16 weighted-roller or,on steep slopes,use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches,laps(min.28 Ib roller)or small areas of the roof that are not accessible to a large roller or broom, 6.4.3 Tile AnP11cation s Lawt allowed for PolvsUck Dual Pro,IR Xe or Polystick MU-X): Reference is made to FRSA/TRI April 2012 (04-12) installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened file roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s),Base Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1. For adhesive-set the applications,refer to Section 5.6.4 herein. 6.4.4 Two(2)Piy Underlavment Systems: Polystick MTS or MTS PLUS followed by Poiystick MTS,MTS PLUS,TU P,TU Pius,TU Max,Tile Pro,MU-X or Polyflex SAP Is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated With the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired. Polystick MLS or MTS PLUS followed by Poiystick TU P,TU Plus,TU Max,Tile Pro or Polyflex SAP is allowable for use under foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. stl.. .A.. .E(ast�pfl.° :�p ?ElaStgfle>G 6:C'i'� .y •{:.: 6.5.1 Elastoflex 6 TU,Elastoflex S6 G or Elastoflex S6 G FR shalt be installed incompliance with current Polyglass published Installation requirements. For use In tile applications: ✓ Elastoflex 6 TU is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"from FRSA/TR1 April 2012(04-12)beneath mechanically fastened the roof systems or the Hot Asphalt applied"Cap Sheet'in the'"fwo Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"from FRSA/TRI April 2012 (0412)beneath mechanically fastened idle roof systems or the Hot Asphalt applied"Cap Sheet"in the'Two Ply System"from FRSA/TRl April 2012(04-12)beneath mechanically fastened or adhered the roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened tile roof systems or the Hot Asphalt applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened the roof systems. 6.5.2 For hot-asphalt-applications,Elastoflex G TU,Mastoflex S6 6 or Elastoflex S6 6 FR shall be fully asphalt-applied to the substrates noted In Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide,off-set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.V )• •J - .n.-'-.'�'::}:.. ;�.i-..; ::C''.i::•'�.::""iyi.~: •.iii 5;}.. ..t�::;:'. 'IP'Fi_yf(ekG'or�P'ofy�li�ac�C��;. ��`� r �' - 's.•.:. .. 6-6.1 Polyflex G or Polyflex G FR shall be installed In compliance with current Polyglass published installation requirements. For use in the applications: ✓ Polyflex 6 is for use as an alternate to the Heat Applied"Cap Sheet"in the`Two Ply System"from FRSA/TRi April 2012(04-12)beneath mechanically fastened or adhered tie roof systems(Base Sheet Limited per 5.6.3). i ✓ Polyflex G FR is for use as an alternate to the Heat Applied"Cap Sheet"in the"Two Ply System"from FRSA/TRi April 2012(0412)beneath mechanically fastened the roof systems(Base Sheet Limited per 5.6.3). MEMO ETC,Ur— Evaluation Report P22060.02M-RJ.4 Certykz to ofAuthorimtron#32455 6'"EDITION(2017)FBC NON-HVH2 EVALUATION FLS259-R26 Poly&ss Roof Underlayments,(9s4)233-123D Revision 24:01"2018 Page 13 of 14 1 e OMEMO(etc. 6.6.2 Polyflex 6 or Polyflex G FR shall be fully torch-applied to the substrates noted in Section S.S. Side laps shall be minimum 34nch and end-laps minimum 6-Inch wide,off-set minimum 3 feet from course to course. Side and end laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staeinm 6.7.1 Tile shall be loaded and staged in a manner that prevents file slippage and/or damage to the underlayment. Refer to Table 2 herein,and Polyglass published requirements for the staging. 6.7.2 Battens and/or Counter-battens,as required by the the manufacturer and FRSA/TRI April 2032(04-12)must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail- boards,to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after Installation of self-adhering membranes and before loading of roofing tiles is forty-eight(48)hours. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C.61620-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. rodu:;.Pcf s .,• •So'eei�'cations<i:::�:�K:::x'.�-�. ..:.,:; `.�:;'::; ( 1.•;. Fernley,NV;Hazleton,PA&Winter Haven,FL ASTM D1970 Pol stick MU-X Hazleton,PA M-D 13-0004 Elastoflex G TU ASTM D1970 Polystick IR-Xe Hazleton,PA&Winter Haven,FL ASTM D1970&FRSA/TRI April 2012 Polystick TU Plus ASTM D1970&FRSA/TRI April 2012 Polystick TU Max Tuscaloosa,AL ASTM D4601,Type II Polyglass G2 Base ASTM D226(physicals) Elastobase,Elastobase P ASTM D6509 Polyglass APP Base FRSA/TRI April 2012 Polystick MTS,Polystick MTS PLUS FRSA/'TRI April 2012 PolystickTU P Winter Haven,FL FRSA/TRI Aprll 2012 Polyflex SAP,Polyflex SA P FR ASTM D1970 Polystick Dual Pro ASTM D1970&FRSA/TRI April 2012 Polystick Tile Pro ASTM D6164 Elastoflex S6,Elastoflex S6 G FR ASTM D6222 Polyflex G,Polyflex G FR 9. QUALITYASSuRANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- NEMO ETC,LLC. Evaluation Report 1312060.02.09-1124 CetVkate ofAuthorkatian#32455 6TM EDITION(2017)FBC NON-HVHZ EVALUATION FL525B428 Polyglass Roof Underlayments;(954)733-1230 Revison 24:01/24/2018 Page 14 of 14