HomeMy WebLinkAboutProduct Approval, underlayments, noa Lo
BCIS Home r �
dbg In User Registration Hot Topics Submit Surcharge Stats&Facts € Publications ( Contact Us BCIS Site Map 'Links Search
a
;_
Product Approval
USER:Public User
Product Aooroval Menu>Product or Aoolication Search>Application List>Application Detail
FL# FL18686-R3 ® �peLo.?�ti
Application Type Revision x,
Code Version 2017
w _ Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
d�q / ry•
f
Co",omments File EL
Archived
S &
Product Manufacturer GAF REVIEWED FOR
r Address/Phone/Email 1 Campus Drive C t9
Parisppany, NJ 07054 CODE COMPLIANCE
(800) 766-3411 g�
mstieh@gaf.com
ST. LUCOE COUNTY
' k 1ualY®C C
Authorized Signature Michael Stieh
mstieh@gaf.com
Technical Representative Michael Stieh
4 Address/Phone/Email 1 Campus Drive
Parsippany, NJ 07054
v (973) 628-3000
mstieh@gaf.com
` Quality Assurance Representative Richard Weiman
Address/Phone/Email 1 Campus Drive
Parsippany, NJ 07054
(973) 872-4421
RWeiman@gaf.com
9, Category Roofing
Subcategory Underlayments
Compliance Method
Evaluation Report from a Product Evaluation Entity
&�•��� � Evaluation Entity Miami-Dade BCCO- EVL �
ec Quality Assurance Entity Miami-Dade BCCO-QUA
Quality Assurance Contract Expiration Date 02/22/2023
Validated By Miami-Dade BCCO-VAL
i
s � �r
� Certificate of Independence
Referenced Standard and Year(of Standard) Standard Year
ASTM D226 2009
Equivalence of Product Standards
Certified By
Sections from the Code
z�
Product Approval Method Method 1 Option C
Date Submitted 02/26/2018
r Date Validated 03/16/2018
Date Pending FBC Approval
Date Approved 03/26/2018
s �.�,fi � Summa "�.Ef Pros�ucls h - -
n 18686.1 FeltBuster High-Traction Synthetic Roofing Felt
�N Limits of Use Installation Instructions
F � ' Approved for use in HVHZ:Yes FL18686 R3 II 18-0119.15.pdf
" .- Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO - EVL
r
z Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: FL18686 R3 AE 18-0119,15.odf
1� Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
a The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
r g Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
- mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
a one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
• 455,F.S.,please click here.
r Product Approval Accepts:
rn t OEM
ii
I
ari"ai
BM
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Rogm 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)3115I-2599
NOTICE OF ACCEPTANCE (NOA) wwFv.miamidadesov/ecdnomv
GAF
1 Campus Drive
Parsipanny,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
I
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform inthe accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
I
DESCRIPTION: GAF Leak Barriers and Roof Deck Protection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the!
materials, use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followedby the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA 16-1213.04 and consists of pages 1 through 10.
The submitted documentation was reviewed by Hamley Pacheco,P.E.
■���®
_ NOA No.: 18-0119.15
COUO2Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 11 of 10
I
ROOFING COMPONENT APPROVAL
Cateeory: Roofing
Sub-Cate2ory: Underlayment
Material: SBS/Polypropylene/Asphalt
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
WeatherWatcho Mineral 36"x 50' rolls ASTM D 1970 Granular surfaced modified, fiberglass reinforced,
Surfaced Leak Barrier 36"x 66.7' rolls bituminous sheet material for use as a leak barrier
Manufacturing underlayment in sloped roof assemblies.
Location#1,9 Designed as an ice&rain shield.
StormGuarde Film 36"x 66.7' rolls ASTM D 1970 Modified,fiberglass reinforced,bituminous sheet
Surfaced Leak Barrier material for use as a high temperature leak barrier
Manufacturing underlayment in sloped roof assemblies.
Location#1,9 Designed as an ice&rain shield.
LibertyTM SBS Self- 39_3/8"x 66' rolls ASTM D 1970 Self-adhering SBS roof membrane.
Adhering Base/Ply Sheet ASTM D4601
Manufacturing Type Il
Location#1,9
Deck-Armor TM Premium 54"x 222' rolls ASTM D 226 A UV-stabilized polypropylene breathable
Breathable Roof Deck 48"x 100' rolls Type II underlayment. To be used for roof deck
Protection protection as an underlayment in sloped roof
Manufacturing assemblies.
Location#2
I
Tiger PawTM Roof Deck 48"x 250' rolls ASTM D 226 A UV-stabilized polypropylene non-breathable
Protection 48"x 100' rolls Type II underlayment.To be used for roof deck protection
Ma as an underlayment in sloped roof assemblies.
ocation#3,5,6
i
FeltBuster®High-Traction 8"x 250' rolls ASTM D 226 A UV-stabilized polypropylene non-breathable
Synthetic Roofing Felt Type I underlayment.To be used for roof deck protection
Manufacturing as an underlayment in sloped roof assemblies.
Location#7,8
-Mate® ck 36"x 144' rolls ASTM D 226 Fibergass-reinforced asphalt felt underlayment. To
Protection Type I be used for roof deck protection as an
Manufacturing underlayment in sloped roof assemblies.
Location#4
i
® ® NOA No.: 18-0119.15
WMIAM.MA09 CO
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 2 of 10
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
LibertyTM SA Glass Cap 39 3/$"x 34' rolls ASTM D 1970 Granular surfaced modified, fiberglass reinforced,
Sheet ASTM D 6163 self-adhering SBS roof membrane.
Manufacturing ASTM D 7530
Location#9
GAFGLAS®Ply 4 39.37" ASTM D2178 Aspahalt impregnated glass felt with aspalik
Manufacturing (1 meter)Wide Type IV coating.
Location#9,10
GAFGLAS®FlexPlyTM 6; 39.37" ASTM D2178 Aspahalt impregnated glass felt with aspahlt
Manufacturing (1 meter)Wide Type VI coating.
Location#9, 10
i
MANUFACTURING LOCATION:
1.Mt. Vernon, IN
2.North Bay, Ontario
3.Mission,British Columbia
4.Pryor, OK
5.Qingdao,China
6.Charleston, SC
7.Spartanburg, SC
8.Dadra, India
9.Savannah, GA
10.Mobile,AL
i
i
f
• NOA No.: 18-0119.15
• P1il�t1kt11lR£CQ1:INTY.
„ f Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 3 of 10
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Intertek Testing Services NA Ltd. 3077464-01 ASTM D 1970 08/231/06
3090131 Wind Uplift and Self Sealability 08/23/06
100258583COQ-OIOA ASTM D 226 Type II 01/08/11
100673818COQ-003 ASTM D 226 Type II 06/13/13
10157289000Q-005 ASTM D 226 Type II 04/17/14
F8549.02-106-18 ASTM D 226 Type I 11/08/16
PRI Construction Materials RGM-023-02-01 ASTM D 4798 05/16/07
Technologies,LLC. GAF-112-02-01 ASTM D 226 Type II 03/15/06
GAF-238-02-01 ASTM D 1970 03/03/10
GAF-323-02-01 ASTM D 1970 11/30/11
GAF-324-02-01 ASTM D 1970 12/01/11
GAF-325-02-01 ASTM D 1970 12/01/11
GAF-326-02-01 ASTM D 1970 11/30/11
GAF-275-02-01 ASTM D 1970 11/11/10
GAF-344-02-01 ASTM D 1970 04/23/12
GAF-339-02-01 ASTM D 226 Type I 03/14/12
ELK-311-02-01 ASTM D 1970 09/11/07
GAF-518-02-01 ASTM D 226 Type I 06/04/14
GAF-818-02-01 ASTM D 4533 12/06/17
GAF-829-02-01 ASTM D 226 Type II 01/15/18
GAF-314-02-01 ASTM D 2178 07/21/11
GAF-315-02-01 ASTM D 2178 07/21/11
Trinity-ERD GAF-SC13285.03.17-1 ASTM D 1970 03/08/17
GAF-SC13285.03.17-3 ASTM D 1970 03/01/17
GAF-SC13285.03.17-4 ASTM D 1970 03/0/17
GAF-SC13285.02.17-2 ASTM D 4601 Type II 02/08/17
GAF-SC9700.08-15-R1 ASTM D 2178 09/09/15
GAF-SC12915.12.17-RI ASTM D 1970 12/11/17
GAF-SC12915.12.17-R1 ASTM D 6163 12/11/17
GAF-SC12915.12.17-R1 ASTM D 7530 12/11/17
® NOA No.: 18-0119.15
.11EMIAM, C Expiration Date: 02/22/23
Approval Date: 02/22/18
Page�4 of 10
APPROVED ASSEMBLIES:
Deck Type 1: Wood,non-insulated
I
Deck Description: 19/3z" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck,membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies
of ASTM D 226 Type II,Deck-Armorl Premium Breathable Roof Deck Protection,FeltBusterlo
High-Traction Synthetic Roofing Felt,or Tiger PawTM Roof Deck Protection with a minimum 4"
side lap and a 6"end lap mechanically fastened to the deck with approved nails and tin caps 6"
o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape(follow the tape's manufacturer's
installation instructions).Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of WeatherWatch®Mineral Surfaced Leak Barrier, StormGuard®Film
Surfaced Leak Barrier,LibertyTM SA Glass Cap Sheet, or LibertyTM SBS Self-Adhering
Base/Ply Sheet membrane with a minimum 3"side lap and 6"end lap. Place the first course of
membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the
release membrane as the membrane is applied. Vertical strapping of the roof with
WeatherWatch®Mineral Surfaced Leak Barrier,or StormGuard®Film Surfaced Leak Barrier is
acceptable.
Surfacing: Approved Roofing Assembly.
I
I,
I
NOA No.: 18-0119.15
• r Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 5 of 10
Deck Type 1: Wood,non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Membrane mechanically fastened to deck.
Separator Sheet: One or more plies of GAFGLAS®Ply 4,GAFGLAS®F1exP1yTM 6, Shingle-Mate®Roof Deck
Protection,Deck-Armor TM Premium Breathable Roof Deck Protection,FeltBuster®High-
Traction Synthetic Roofing Felt, or Tiger PawTM Roof Deck Protection loose laid.
Membrane: One or more plies of WeatherWatch®Mineral Surfaced Leak Barrier, StormGuard®Film
Surfaced Leak Barrier,LibertyTM SA Glass Cap Sheet,or LibertyTM SBS Self-Adhering
Base/Ply Sheet membrane mechanically fastened with a minimum 3"side lap and a 6"end lap to
deck through the separator sheet with approved nails and tin caps 6" o.c. at the laps and two
staggered rows 12" o.c. in the field of the roll.
Surfacing: Approved Roofing Assembly.
i
i
I
i
I
MIAMMOE+CQtlN ft'
NOA No.: 18-0119.15
LUB Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 6 of 10
i
Deck Type 1: Wood,non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck,membrane adhered.
Secondary Water Install a minimum 4"wide WeatherWatch®Mineral Surfaced Leak Barrier, ,LibertyTM SBS
Barrier: Self Adhering Base/Ply Sheet,LibertyTM SA Glass Cap Sheet,or StormGuard®Film Surfaced
(Optional) Leak Barrier membrane over the joints of the plywood roof deck prior to installation of the base
sheet.Do not overlap end or side joints.All side and end laps should be butted firmly side by
side,flush with each other but not overlapped.Do not leave the WeatherWatch®Mineral
Surfaced Leak Barrier, or StormGuard®Film Surfaced Leak Barrier membrane exposed fori more
than 30 days without a roof deck protection underlayment protecting the secondary water barrier.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more;plies
of ASTM D 226 Type lI,Deck-Armoi'Premium Breathable Roof Deck Protection,
FeltBuster®High-Traction Synthetic Roofing Felt, or Tiger Paw'Roof Deck Protection with a
minimum 4"side lap and a 6"end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape(follow the tape manufacturer's)
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fasteners.
Surfacing: Approved Roofing Assembly.
I
I
® NOA No.: 18-0119.15
btif�Mf A"jpccou T`a'
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 7 of 10
Deck Type 1: Wood,non-insulated
Deck Description: 19/32° or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck,membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies
of ASTM D 226 Type II,Deck-ArmorTM Premium Breathable Roof Deck Protection,
Felt Buster'High-Traction Synthetic Roofing Felt, or Tiger PawTM Roof Deck Protection with a
minimum 4"side lap and a 6"end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c.at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape(follow the tape's manufacturer's
installation instructions).Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of StormGuard®Film Surfaced Leak Barrier membrane with a minimum'4"
side lap and 6"end lap. Place the first course of membrane parallel to the eave,rolling the;
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied.
i
Surfacing: Approved for Metal roofing,Slate,and Asphalt Shingle assemblies.
I
i
I
i
I
i
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page'8 of 10
I
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Armor'
Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection,shall not be used as roof tile underlayment.
3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak
Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck
Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBusterm High-Traction Synthetic
Roofing Felt, and Tiger PawTM Roof Deck Protection shall be installed in strict compliance with applicable
Building Code.
4. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Armoi'
Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection membranes shall be applied to a smooth, clean and dry surface with deck free of
irregularities.
5. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-ArmorTM
Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection membranes shall not be applied over an existing roof membrane.
6. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-ArmorTM
Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM
Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application. j
7. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Armor'
Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger Paw TM
Roof Deck Protection may be used with any approved roof covering Notice of Acceptance listing WeatherWatch®
Mineral Surfaced Leak Barrier, StormGuard®Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply
Sheet, LibertyTM SA Glass Cap Sheet, Shingle-Mate®Roof Deck Protection, Deck-ArmorTM Premium Breathable
Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection
as a component part of an assembly in the Notice of Acceptance. If WeatherWatch® Mineral Surfaced Leak
Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, Liberty)M SA
Glass Cap Sheet, Shingle-Mate®Roof Deck Protection,Deck-Armor Premium Breathable Roof Deck Protection,
FeltBuster®High-Traction Synthetic Roofing Felt and Tiger PawTM Roof Deck Protection are not listed; a request
may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department
for approval provided that appropriate documentation is provided to detail compatibility of the products; wind
uplift resistance,and fire testing results.
8. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application. Install when temperatures are 450I F and
rising.
9. When applying the in in the valley, start at the low point and work to the high point,rolling the merilbrane
from the center outward in both directions.
NOA No.: 18-0119.15
'Em"MAOECOUNWExpiration Date: 02/22/23
Approval Date: 02/22/18
Page 9 of 10
I
LIMITATIONS: i
10. Roll or broom the entire membrane surface so as to have 100%contact with the surface,giving special attention to
overlap areas.
11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or,logo,
city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control
Approved" or the Miami-Dade County Product Control Seal as shown below.
} „
END OF THIS ACCEPTANCE
I
I
I
I
I
NOA No.: 18-6119.15
MlAMt1?Ab�CC?UN'fY -
► Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 10 of 10
- - I