HomeMy WebLinkAboutProduct Approval 1/412018 Florida Building Code Online
r +M9rraw-i
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Map Links�Se
b
a
USER:Publict c Public User
RECEIVE®
!
Product Approval Menu>Product or Application Search>Application List>Application Dete 11 O C('r 18 ? E
'.� # FL17022-R7
l ' , FL
Application Type Revision ST. Lucie County, Permitting
Code Version 2017
Application Status Approved
Comments 08/18/2017x.date reapply 08/21/17
Archived
Product Manufacturer Extreme Metal Fabricators,LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
f lva i i dati on @yahoo.cam
Authorized Signature Richard McKuhen
nvalldation@yahoo.com
File
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990 [i"
(772)872-8034 RE I�� V6
richard@emfab.net CODE COMPLIANCE
Quality Assurance Representative ST. LUCIE COQ :T( �I`
Address/Phone/Email
BOCC
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Flc
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License , PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R.Priest,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr,pdf
Referenced Standard and Year(of Standard) Standard Year
- TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
https:/Avww.flo6dabuilding.org/prlor app dti.aspx?param--wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR°/a2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 114
114/2018
Florida Building Code Online
Sections from the Code
Product Approval Method Method I Option D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08/2812017
Date Approved 10/10/2017
ummar of Products
Fl.# Model, Number or Name Description
17022.1 1 -"SV Crimp"(RG) 26 Gauge steel, 3/8"rib height, 24"wide lapped roof panel
mechanically attached to 15/3211 plywood or Wood Deck wil
fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No EL17022 R7 11 FL 17022.1 5 V CRIMP ssrpdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions.Install the
I FL17022 R7 AE EL 17022,1-5 V CRIMP ssr.r)df
assembly in compliance with the installation method listed In ' Created by Independent Third Party, Yes
this report and applicable code sections of FBC. Refer to
manufacturer's Installation in tions.
17022.2 2-"5V Crimp"(116) 0.032"Aluminum, 3/8"Rib height,21"wide lapped roof pa
mechanically attached to 15/32'plywood or Wood Deck wil
exposed fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ.-No FL17022 R7 11 FL 1702 CRIMP 0.032 ALUM
12,2 5 V ssr.p
Approved for use outside HVHZ:Yes Verified By: Locke Bowdenr P.E.49704
Impact Resistant; No Created by Independent Third Party; Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other;Refer to evaluation report for conditions.Install the EU7022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr
assembly in compliance with the installation method listed in Created by Independent Third Party: Yes
this report and applicable code sections of FBC.Refer to
manufacturer's Installation instructions.
17022.3 3 "I.T' Mechanical Seam"(115) 1.5"rib height, 16"wide,24 gauge steel,standing seam rc
panel mechanically attached to 15/32"plywood or wood de
with clips and fasteners.
Limits of Use i Installation Instructions
Approved for use In HVHZ:No FL17022 R7 11 FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ:Yes seam 24ga ssr.Rdf
Impact Resistant: No Verified By: Locke Bowden,P.E.49704
Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes
other: Refer to evaluation report for conditions and Evaluation Reports
limitations of use,Install the assembly In compliance with the FL17022 R7 AE--FL17022.3 1.5 MECHANICAL
installation Method listed in this report and applicable code I seam 24ga sscodf
sections of FBC. Refer to manufacturer's Installation r Created by independent Third Party:Yes
instructions.
17022.4 4-"1.5"Mechanical Seam"(115) 1.5"rib height, 16"wide,0.032"aluminum,standing seam
roof panel mechanically attached to 15132"plywood or Wot
Deck with clips and fasteners.
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL17022 R7 11 FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ:Yes ALUMINUM ssrod
Impact Resistant.,No Verified By: Locke Bowden,P.E.49704
Design Pressure; +N/A/-Table A Created by Independent Third Party'.Yes
Other- Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly In compliance with the FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
installation method listed in this report and applicable code ALUMINUM ssrodf
sections of FBC. Refer to manufacturer's installation Created by Independent Third Party:Yes
Instructions.
17022.5 in, Nall Strip"(115) 1"rib height, 16"wide,26 gauge steel,standing seam roof
^--i',-,-c-rnl,(w-rr-riur)(3vAfla%3d%3d 2/4
114/2018 Florida Building Code Online
panel mechanically attached to 15/32"plywood or wood de
with fasteners.
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP s-snod
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure,+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 97 AE EL 170225 1.0 MAILS—TRIP sgr.gdf
limitations of use.Install the assembly In compliance with the Created by Independent Third Party:Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
Instructions.
17022.6 6-"I in.Nail Strip"(RS) 1"rib height, 16"wide,0.03211 aluminum,standing seam rl
panel mechanically attached to attached to 15/3211 plywooc
Wood Deck with fasteners,
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL17022 R7 IT FL 17022.6 1.0 NAIL STRIP 0.032
Approved for use outside HVHZ.Yes ALUM ssr.pd
Impact Resistant:No Verified By: Locke Bowden, P.E.49704
Design Pressure:+N/At-Table A Created by Indipendent Third Party: Yes
Other. Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with the &17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
Installation method listed in this report and applicable code ALUM ssnod
sections of FBC. Refer to manufacturer's Installation Created by Independent Third Party: Yes
instructions.
17022.7 7-"1.5 in. Nail Strip"(RS) 1.5"rib height, 19"wide,26 gauge steel,standing seam rc
panel mechanically attached to 15/32"plywood or wood de
with fasteners.
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL17022 R7 II FL 17022.7 1.5 Nail Stein 26Q6 ssr-od
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party: Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for conditions and FL17Q22 R7 AE FL 17022.7 1.5 Nail Strip 260A ssrpdf
limitations of use.Install the assembly in compliance with the Created by Independent Third Party: Yes
installation method listed In this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.8 8-"EMAX Rib-(115) 29 gauge steel, lapped roof panel mechanically attached to
15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use In HVHZ.No FL17022 R7 11 FL 177022.8 EMAX Rib ssr.odf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/At-Table A Evaluation Reports
Other. Refer to evaluation report for conditions and FL17922 R7 Ar: FL 177022.8 EMAX Rib ssr od
limitations of use. Install the assembly in compliance with the Created by Independent Third Party:Yes
installation method listed in this report and applicable code
sections of FBC.Refer to manufacturer's Installation
instructions.
17022.9 9-" PBR MAX'(115) 26 gauge steel,lapped roof panel mechanically attached to
15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL17022 R7 11 EL,17022.9 PBR RIB ssrpdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for conditions and FL17022-R7 AF- Fl-17022.9 PBR RIB-ssr.pdf
limitations of use. Install the assembly In compliance with the Created by Independent Third Party: Yes
installation method listed In this report and applicable code
sections of FBC. Refer to manufacturer's Installation
instructions.
Contaa Us;:2601 Blair Stone Road.1111ahassee EL 32399 Qhone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 20077-2013 state of Florida-::privacy Steinman ::Accessibility statement::Refund statement
640-11......f^Arlahifildinn nrn/nr/nr ano di.ast)x?Daram--wGEVXQwtDqv2aBQpHpQQe6rmZMkUEoR%2bGxHoxFe5QkCHzEqvOQveeg%3d%3d 314
„Product ReportFabricators,
2160 SW Poma Drive
Palm City,FL 34990
772)872-8034
,Florida Product Approval # 17022.1 5-VCrimp NON HVHZ
Compliant with Florida Building Code 2017(fig'ed.)
Compliant with Florida Product Approval Rule#61G20-3
Compliant: Keystone Certifications
Product:S V Crimp 26GA Steel Roof Panel FBC Sec. 1SO7.4.2
Yield strength:SO ksi min.;Attached to min.15/32”plywood or Wood
Deck w/min.0.42 specific gravity with screws. 24" Coverage
Rib Height 3/$"
Corrosion Resistant Compliant: FBC Sec. 1S07A.3
Fastener 1 (Method 1 Attachment):#9 x 1-1/2" Hex-Washer Head wood screw*to penetrate
3/16" min.thru deck or S/8"embedment into wood plank.(*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3,&4 Attachment):#10 x 1-1/2" Hex-Washer Head wood screw*to
penetrate 3/16"min.thru deck or 5/8"embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope:Shall be In compliance with FBC Sec. 1507.
See Fastener attach ent specificat pas above
Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4
DESIGN PRESSURE* -86 PSF .93.5 PSF -101 PSF -228 PSF
ROW SPACING 16"o.c. 16"o.c. A 8"o.c. 6"o.c.
FASTENER SPACING ALONG Panel width) 12"o.c. 12"o.c. 12"o.c. 12"o.c.
FASTENER SIZE 1 #9 #10 #10 #10
Reference Data: ARCHITECTURAL TESTING,INC.TST ID#:1527
UL 580-06&1897-041 Test Report 006893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 12S-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY--UL 1897-o4 is equivalent to test standard UL 1897-1��tttr Vesrgnpressure margin of safety 2:1
Lucke Bowden,P.E.does not have,not will acquire a,financial intie ` ,�s44Y m.�fq�facturing or distributing products
under this evaluation. +•• °„
Locke Bowden,P.E.is not owned,operated,or controlled by air compa�itiii,mi6�fabttures,arbstributing products under this
report.
/jo'� o �S A�t: •fid .mss
A VK
�r,s.''/O MAL��°.•°'
FI-17022.1 5V Crimp (26GA Steel), 24"Wide Roof Panel -Details
Limitations:
1.Underlayment to be compliance with current Florida Building Code(FBC)2017 6th ed.
2.Minimum slope to be compliant with Florida Building Code 2017 601 ed.,and per with Manufacturer's installation reference.
3.Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7.This report does not imply warranty,installation,recommended product use outside of this report.
Faste"-
#9-1-1irMin. '
#10 x 1-112"Min.peFTsbIbA'for Row 5-V Cwnp Roof Paid
Spacing and Design Pressures
Hex Washer Head Wood Scram
Dedc
1WXor greater PlMood,or
Mod plank
-we
318' 12'
Q P T 10 M L STI;UAT I t I W
Panel Profile
Nominal 12" Nominal 12"
O.C. O.G.
Fasten
TP—Ti--1/2"Min. or #10 x 1-1/2"Min.per
Table"A" Hex Washer Head Screw
Spaced 12"o.c.across the Panel Wdth
Panel Refer to Table"A"for Spacing Along Panel
Overlap Length
Deck-15/32"or greater
Plywood,or
-ftod plank
A