Loading...
HomeMy WebLinkAboutROSSMAN PERMIT PACKAGEWINDOW/DOOR SCHEDULE APPROX IGNATION IMPACT PROTECTION ID OPENING ** IMPACT NEW * REMARKS NO SIZE TYPE GLASS EXISTING (WXH) SHUTTER SHUTTER 1 120 X 51.75 HR X 17-0411.08 DP +65/-70 2 PHS3068 LHOS X FL 15210.1 DP +75/-75 3 94.25 X 52.25 HR 17-0411.08 DP +50/-50 4 92.25 X 52.25 HR 17-0411.08 DP +50/-50 5 83.75 X 51.25 HR 17-0411.08 DP +50/-50 6 83.75 X 51.25 HR 17-0411.08 DP +58/-58 7 89.25 X 51.25 HR 17-0411.08 DP +58/-58 8 25.25 X 61.75 SH 17-0630.05 DP +50/-50 9 25.25 X 61.75 SH 17-0630.05 DP +50/-50 10 52 X 49.375 SH 17-0630.05 DP +50/-50 11 52 X 49.375 SH 17-0630.05 DP +50/-50 12 25.25 X 37.125 SH 17-0630.05 DP +50/-50 13 35 X 49.375 SH 17-0630.05 DP +50/-50 14 35 X 49.375 SH 17-0630.05 DP +50/-50 15 35 X 49.375 SH 17-0630.05 DP +50/-50 16 35 X 49.375 SH 17-0630.05 DP +50/-50 17 35 X 49.375 SH 17-0630.05 DP +50/-50 18 35 X 49.375 SH 17-0630.05 DP +50/-50 19 35 X 49.375 SH 17-0630.05 DP +50/-50 20 35 X 49.375 SH 17-0630.05 DP +50/-50 21 35 X 49.375 SH 17-0630.05 DP +50/-50 22 25.25 X 37.125 SH 17-0630.05 DP +50/-50 23 24 25 26 27 28 29 30 31 32 33 *Window Replacement using existing shutters to comply with impact protection will require the existing shutters to meet the requirements of the 2010 FBClResidential R301.2.1.2 TOTAL GLAZED OPENING AREA FOR 8TRUCTURE: 8.F. PERCENTAGE OF NEW GLAZED AREA: (TOTAL INSTALLED GLAZED AREA DIVIDED BY TOTAL GLAZED OPENINGS FOR STRUCTURE) NOTE: The replacement of more than 25 of the aggregate area of exterior glazing (windows & doors) in one & two family dwellings within a 12 month period will require impact protection on all proposed glazed opening replacement (approved shutters or impact resistant glazing) as per 20 I 0 FBCI EXISTING BUILDING 606.4. ** TYPE WINDOWS SH – SINGLE HUNG AWN – AWNING SL – SLIDING DR – DOUBLE HUNG CAS – CASEMENT FIX – FIXED ROSSMAN 4475 S INDIAN RIVER DR., FORT PIERCE Building height Zone 4 Area 15 20 25 30 35 40 45 50 55 60 10 pos 46 48.5 50.4 52 53.2 54.5 55.7 56.7 57.6 58.6 neg 49.9 52.6 54.7 56.4 57.7 59.1 60.4 61.5 62.5 63.5 20 pos 44.1 46.5 48.3 49.8 51 52.2 53.4 54.3 55.2 56.1 neg 47.9 50.5 52.5 54.1 55.4 I 56.7 58 59 60 60.9 50 pcs 43 45.3 47 48.5 49.7 50.8 52 52.9 53.8 54.6 neg 45.1 47.5 49.4 50.9 52.1 53.3 54.6 55.5 56.4 57.3 100 pos 39.2 41.3 42.9 44.2 45.3 46.4 47.4 48.2 49 49.8 neg 43 45.4 47.1 48.6 49.8 50.9 52.1 53 53.9 54.8 500 pos 34.3 36.2 37.6 38.7 39.7 40.6 41.5 42.2 42.9 43.6 neg 38.2 40.3 41.8 43.1 44.2 45.2 46.2 47 47.8 48.6 Building height End zone 5 15 20 25 30 35 40 45 50 55 60 10 pos. 46 48.5 50.4 52 53.2 54.5 55.7 56.7 57.6 58.6 neg 61.7 65 67.5 69.6 71.3 73 74.7 75.9 77.2 I 78.4 20 pos 44.1 46.5 48.3 49.8 51 52.2 53.4 54.3 55.2 56.1 neg 57.5 60.6 63 64.9 66.5 68.1 69.6 70.8 72 73.2 50 pos 43 45.3 47 48.5 49.7 50.8 52 52.9 53.8 54.6 neg 51.9 54.8 56.9 58.7 60.1 61.5 62.9 64 65 66 100 pos 39.2 41.3 42.9 44.2 45.3 46.4 47.4 48.2 49 49.8 neg 47.9 50.5 52.5 54.1 55.4 56.7 58 59 59.9 60.9 500 pos 34.3 36.2 37.6 38.7 39.7 40.6 41.5 42.2 42.9 43.6 neg 38.2 40.3 41.8 43.1 44.2 45.2 46.2 47 47.8 48.6 Wind design Pressure Chart for structures subject to Florida Residential Code 170 mph exposure D Wall component and Cladding pressures from Table R302.2(2) modified by adjustment factors from R301.1(3). Converted to Vasd according to R302.1.2.1.1 ROSSMAN 4475 S INDIAN RIVER DR FORT PIERCE BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL15210-R6 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Plastpro Inc. / Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440) 969-9773 Ext 16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440) 969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440) 969-9773 Ext 16 ronoconnell@plastpro.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Lyndon F. Schmidt, P.E. Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan J. King, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL15210_R6_COI_(a) Certificate of Independence.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 1998 ASTM D638 2003 ASTM E1300 2004 ASTM E84 2005 ASTM G26 1995 G 155 2005 TAS 201, 202, 203 1994 Page 1 of 4Florida Building Code Online 6/5/2019https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ1Q... FL15210.1 6_8 OPAGUE FIBERGLASS SINGLE DOOR IN_OS Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15210_R6_Equiv_(a) Equivalency of Standards.pdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/13/2017 Date Validated 09/18/2017 Date Pending FBC Approval 09/20/2017 Date Approved 12/12/2017 Summary of Products FL #Model, Number or Name Description 15210.1 a. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 6'8 "Impact" Opaque Fiberglass Single Door - Inswing/Outswing (X - Configuration) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.1 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.1.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.1.pdf Created by Independent Third Party: Yes 15210.2 b. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 6'8 "Impact" Opaque Fiberglass Single Door with Sidelite or Sidelites - Inswing/Outswing (OX or XO; OXO - Configurations) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.2 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.2.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.2.pdf Created by Independent Third Party: Yes 15210.3 c. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 6'8 "Impact" Opaque Fiberglass Double Door with or without Sidelites - Inswing/Outswing (XX; OXXO - Configurations) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.3 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.3.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.3.pdf Created by Independent Third Party: Yes 15210.4 d. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 6'8 "Impact" Glazed Fiberglass Single Door - Inswing/Outswing (X - Configuration) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.4 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.4.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.4.pdf Created by Independent Third Party: Yes 15210.5 e. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 6'8 "Impact" Glazed Fiberglass Single Door with Sidelite or Sidelites - Inswing/Outswing (OX or XO; OXO - Configurations) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Installation Instructions FL15210_R6_II_(b) Inst 15210.5.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports Page 2 of 4Florida Building Code Online 6/5/2019https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ1Q... Other: See INST 15210.5 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. FL15210_R6_AE_(b) Eval 15210.5.pdf Created by Independent Third Party: Yes 15210.6 f. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 6'8 "Impact" Glazed Fiberglass Double Door with or without Sidelites - Inswing/Outswing (XX; OXXO - Configurations) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.6 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.6.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.6.pdf Created by Independent Third Party: Yes 15210.7 g. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 8'0 "Impact" Glazed Fiberglass Single Door - Outswing (X - Configuration) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.7 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.7.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.7.pdf Created by Independent Third Party: Yes 15210.8 h. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 8'0 "Impact" Glazed Fiberglass Single Door with Sidelite or Sidelites - Outswing (OX or XO; OXO - Configurations) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.8 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.8.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.8.pdf Created by Independent Third Party: Yes 15210.9 i. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 8'0 "Impact" Glazed Fiberglass Double Door with or without Sidelites - Outswing (XX; OXXO - Configurations) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.9 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.9.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.9.pdf Created by Independent Third Party: Yes 15210.10 j. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 8'0 "Impact" Opaque Fiberglass Single Door - Outswing (X - Configuration) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.10 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.10.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.10.pdf Created by Independent Third Party: Yes 15210.11 k. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 8'0 "Impact" Opaque Fiberglass Single Door with Sidelite or Sidelites - Outswing (OX or XO; OXO - Configurations) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.11 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.11.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.11.pdf Created by Independent Third Party: Yes 15210.12 l. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 8'0 "Impact" Opaque Fiberglass Double Door with or without Sidelites - Outswing (XX; OXXO - Configurations) Page 3 of 4Florida Building Code Online 6/5/2019https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ1Q... Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.12 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.12.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.12.pdf Created by Independent Third Party: Yes 15210.13 m. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 8'0 "Impact" Opaque Fiberglass Single Door with Surface Bolts - Outswing (X - Configuration) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.13 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.13.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.13.pdf Created by Independent Third Party: Yes 15210.14 n. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 8'0 "Impact" Opaque Fiberglass Double Door with Surface Bolts on Active Door panel - Outswing (XX - Configuration) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.14 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.14.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.14.pdf Created by Independent Third Party: Yes 15210.15 o. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 8'0 "Impact" Glazed Fiberglass Single Door utilizing the WINDSERT™ an operational window insert - Outswing (X - Configuration) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15210.15 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL15210_R6_II_(b) Inst 15210.15.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15210_R6_AE_(b) Eval 15210.15.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Page 4 of 4Florida Building Code Online 6/5/2019https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ1Q...