Loading...
HomeMy WebLinkAboutProduct approval (2) Page: 9 10/22/2019 06: 44 AM TO: 17724621578 FROM:7722176820 MIAMI DARE COUNTY MIAMI. PRODUCT CONTROL SECTION E 11805 SW 26 Sftot,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33I75-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F086)315-2599 NOTICE OF ACCEPTANCE(NOA.) .v-1 i.Miamia:Ia?—v/economy GAF 1 Campus Drive Parsippany,Nr 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below The Miami Dade County Product Control Section(In Miami Dade County) and/or the AHD (in areas other than Miami Dade County)reserve theright to have this product or material tested for quality assurance purposes.If this product or material fails to pedonn in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves theright to revoke this acceptance,if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:GAF Timberline HD°Timberline®Natural Shadow%Timberline®American Harvest°,and Fortitude=Shingles LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state andfollowing statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affectingthe performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami--Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then itshall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its-distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA it 14-1022.20 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA We.-.16-0811.1Y MwtsrD=- F-Courm ExpirationDate:02/21122 ,...� i Approval Date:02/09/17 Page I of 6 Page: 11 10/22/2019 06: 44 AM TO: 17724621578 FROM:7722176820 ROOFING ASSEMBLY APPROVAL Cateaou: Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves GAF Timberline HD®Timberline°Natural Shadow',Timberline American°Harvest°,and Fortitude=Shingles as manufactured by OAF as described in this Notice of Acceptance. PP.ODTJCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline HDO 13%"x 39 3/8" TAS 110 Fiberglass reinforced heavyweight asphalt Manufacturing roof shingle,with a laminate profile Locations#1,2,3,4,5,6,7 GAF Timberline Natural 13 1/4"x 39 3/s TAS 110 Fiberglass reinforced heavy weight asphalt Shadow' roof shingle,with a laminate profile Manufacturing Locations 01,2,3,4,5,6,7 GAF Timberline°American 131/;x 39 3/s TAS 110 Fiberglass reinforced heavy weight asphalt Harvest® roof shingle,with a laminate profile Manufacturing Locations 02,4,5,6 GAF FortitudeTD= 131/4"x 39 3/sem TAS 110 Fiberglass reinforced heavyweight asphalt Manufacturing roof shingle,with a laminate profile Locations 91,4 MANIII'ACTURING LOCATION 1. Tampa,FL 2. Michigan City,IN 3. Baltimore,MD 4. Myerstown,PA 5. Ennis,TX 6. Tuscaloosa,AL 7. Dallas,TX NOAk:16-0811.11 MU M OAnaCOLITM Expiration Date:02121 1/22 Approval Date:02/09/17 Paget of 6 Page: 13 10/22/2019 06:44 AM 70: 17724621578 FROM1: 7722176820 EVIDENCE SUSItz1TTED Test Anenc Test Tdenfitxer Test Name/Renort Date Underwriters Laboratories,= ASTM D3462 4787344101 07/25/16 Underwriters Laboratories,Inc. ASTMD3462 IICA48924 10/24/11 Underwriters Laboratories,Inc ASTM D3462 IOCA21994 04/22/11 Underwriters Laboratories,Inc ASTMD3462 I OCA28717 07/26111 Underwriters Laboratories,Inc. ASTMD3462 OSCA47541 11/10/06 Underwriters Laboratories,Inc. ASTMD3462 06CA31580 11130/06 PRI Asphalt Technologies,Inc. ASTMD3462 GAF-101-02-02 11/02/05 Underwriters Laboratories,Inc. ASTMD3462 06NK05159 08/09/06 PRI Asphalt Technologies,Inc. ASTMD3462 GAF-099-02-02 11/08105 Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories,Inc. ASTM D3462 03NK26444 10/17/03 Center for Applied Engineering ASTMD3462 257989 05/13/97 Underwriters Laboratories,Inc. TAS 107 01NK45803 04/13194 Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05 Underwriters Laboratories,Inc. TAS 107 02NK41811 11./11102 { Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies,Inc. TAS 100 GAP-044-02-01 01/13104 PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies,Inc. TAS 100 GAP-101-02-01 11/09/05 PRI Asphalt Technologies,Inc- TAS 100 GAF-116-02-02 03/23/06 PRI Asphalt Technologies,Inc. TAS-100 UK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-095-02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21/02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 LDUTATIONS 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 fl. 3. All products listed herein shall have a quality*assurance audit in accordance with the Florida Building Code and Rule 61 G20 3 of the Florida Administrative Code. NOANo.:16 0811.11 wEeo� Expiratia:tDate:02/21/22 Approval Date:02/09/17 Page 3 of 6 Page: 15 10/22/2019 06:44 AM TO: 17724621578 FROM:7722176820 INSTALLATION L Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 . 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A',attached. 5. Nailing shall be in compliance with Detail B,attached. LABELING Shingles shall bear the imprint or identifiable marldng of the manufacturer's name or logo, city and state of manufacturing facility,and following statement:"Miami Dade County Product Control Approved"or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY BUILDING PERART REQUIREMENTS L Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the.applicable code in order to properly evaluate the installation ofthis system. i NOAN6.:16-0811.11 MMM OADEExpiration Date:02/21/22 Approval bate:02/09/17 Page 4 of 6 Page: 17 10/22/2019 06:44 AM TO: 17724621578 FROM:7722176820 DETAIL A COURSE L&YOUT DECK FULL 5th 17"OFF 4th 11"OFF 3rd 6"OFF 2nd FULL 1st NOANo.:16-0811.11 Mu►Mtnab�cottNrY MpintionDate.:02/21/22 Approval Date:02109n7 Page 5 of 6 Page: 19 10/22/2019 06:44 AM TO: 17724621578 FROM:7722176820 DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 39-31811 DO M ) za-�rz"-sirr' �a-uzn-� �rzn �j lass-4o mm) Asa-4a m) all gUde line 13- 1q 1AR' sg14'-sU4" (146mm•159mm) VZ-2-11r from boflanofshlogle eif seal adhesNe on bask ENHANCED NAILING PATTERN -six nails per shingle* •required by some local codes and required for enhanced wind coverage on cedoin products, see Smiled wartantyfordelaSs. These shingles MUST be nailed a nominal 8"(152mm)from bottom of of shingle,above the cut outs,as shown.mails must not be exposed. END OF THIS ACCEPTANCE 90ANo.:16-0811.11 Ic4larrtflafofaoourm EupiratioaDate:02121/22 Approval Date:02/09/17 Page 6 of 6