HomeMy WebLinkAboutProduct approval (2) Page: 9 10/22/2019 06: 44 AM TO: 17724621578 FROM:7722176820
MIAMI DARE COUNTY
MIAMI. PRODUCT CONTROL SECTION
E 11805 SW 26 Sftot,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33I75-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F086)315-2599
NOTICE OF ACCEPTANCE(NOA.) .v-1 i.Miamia:Ia?—v/economy
GAF
1 Campus Drive
Parsippany,Nr 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below The Miami Dade County Product Control
Section(In Miami Dade County) and/or the AHD (in areas other than Miami Dade County)reserve theright to
have this product or material tested for quality assurance purposes.If this product or material fails to pedonn in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves theright to
revoke this acceptance,if it is determined by Miami Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:GAF Timberline HD°Timberline®Natural Shadow%Timberline®American Harvest°,and
Fortitude=Shingles
LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state andfollowing
statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affectingthe performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami--Dade County,Florida,and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then itshall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its-distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA it 14-1022.20 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
NOA We.-.16-0811.1Y
MwtsrD=- F-Courm ExpirationDate:02/21122
,...� i
Approval Date:02/09/17
Page I of 6
Page: 11 10/22/2019 06: 44 AM TO: 17724621578 FROM:7722176820
ROOFING ASSEMBLY APPROVAL
Cateaou: Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves GAF Timberline HD®Timberline°Natural Shadow',Timberline American°Harvest°,and
Fortitude=Shingles as manufactured by OAF as described in this Notice of Acceptance.
PP.ODTJCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GAF Timberline HDO 13%"x 39 3/8" TAS 110 Fiberglass reinforced heavyweight asphalt
Manufacturing roof shingle,with a laminate profile
Locations#1,2,3,4,5,6,7
GAF Timberline Natural 13 1/4"x 39 3/s TAS 110 Fiberglass reinforced heavy weight asphalt
Shadow' roof shingle,with a laminate profile
Manufacturing
Locations 01,2,3,4,5,6,7
GAF Timberline°American 131/;x 39 3/s TAS 110 Fiberglass reinforced heavy weight asphalt
Harvest® roof shingle,with a laminate profile
Manufacturing
Locations 02,4,5,6
GAF FortitudeTD= 131/4"x 39 3/sem TAS 110 Fiberglass reinforced heavyweight asphalt
Manufacturing roof shingle,with a laminate profile
Locations 91,4
MANIII'ACTURING LOCATION
1. Tampa,FL
2. Michigan City,IN
3. Baltimore,MD
4. Myerstown,PA
5. Ennis,TX
6. Tuscaloosa,AL
7. Dallas,TX
NOAk:16-0811.11
MU M OAnaCOLITM Expiration Date:02121 1/22
Approval Date:02/09/17
Paget of 6
Page: 13 10/22/2019 06:44 AM 70: 17724621578 FROM1: 7722176820
EVIDENCE SUSItz1TTED
Test Anenc Test Tdenfitxer Test Name/Renort Date
Underwriters Laboratories,= ASTM D3462 4787344101 07/25/16
Underwriters Laboratories,Inc. ASTMD3462 IICA48924 10/24/11
Underwriters Laboratories,Inc ASTM D3462 IOCA21994 04/22/11
Underwriters Laboratories,Inc ASTMD3462 I OCA28717 07/26111
Underwriters Laboratories,Inc. ASTMD3462 OSCA47541 11/10/06
Underwriters Laboratories,Inc. ASTMD3462 06CA31580 11130/06
PRI Asphalt Technologies,Inc. ASTMD3462 GAF-101-02-02 11/02/05
Underwriters Laboratories,Inc. ASTMD3462 06NK05159 08/09/06
PRI Asphalt Technologies,Inc. ASTMD3462 GAF-099-02-02 11/08105
Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02
Underwriters Laboratories,Inc. ASTM D3462 03NK26444 10/17/03
Center for Applied Engineering ASTMD3462 257989 05/13/97
Underwriters Laboratories,Inc. TAS 107 01NK45803 04/13194
Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06
Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04
Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05
Underwriters Laboratories,Inc. TAS 107 02NK41811 11./11102
{ Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03
Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04
Center for Applied Engineering TAS 100 257989 04/01/97
PRI Asphalt Technologies,Inc. TAS 100 GAP-044-02-01 01/13104
PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05
PRI Asphalt Technologies,Inc. TAS 100 GAP-101-02-01 11/09/05
PRI Asphalt Technologies,Inc- TAS 100 GAF-116-02-02 03/23/06
PRI Asphalt Technologies,Inc. TAS-100 UK-083-02-01 10/16/02
ELK-084-02-01 10/15/02
ELK-095-02-01 10/14/02
ELK-086-02-01 10/24/02
ELK-087-02-01 10/21/02
ELK-088-02-01 10/16/02
ELK-107-02-01 10/09/03
ELK-108-02-01 10/09/03
ELK-109-02-01 10/09/03
LDUTATIONS
1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 fl.
3. All products listed herein shall have a quality*assurance audit in accordance with the Florida Building Code
and Rule 61 G20 3 of the Florida Administrative Code.
NOANo.:16 0811.11
wEeo� Expiratia:tDate:02/21/22
Approval Date:02/09/17
Page 3 of 6
Page: 15 10/22/2019 06:44 AM TO: 17724621578 FROM:7722176820
INSTALLATION
L Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115 .
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A',attached.
5. Nailing shall be in compliance with Detail B,attached.
LABELING
Shingles shall bear the imprint or identifiable marldng of the manufacturer's name or logo, city and state of
manufacturing facility,and following statement:"Miami Dade County Product Control Approved"or the Miami-Dade
County Product Control Seal as shown below.
MIAMI•DADE COUNTY
BUILDING PERART REQUIREMENTS
L Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the.applicable code in order to properly
evaluate the installation ofthis system.
i
NOAN6.:16-0811.11
MMM OADEExpiration Date:02/21/22
Approval bate:02/09/17
Page 4 of 6
Page: 17 10/22/2019 06:44 AM TO: 17724621578 FROM:7722176820
DETAIL A
COURSE L&YOUT
DECK
FULL
5th
17"OFF 4th
11"OFF 3rd
6"OFF 2nd
FULL 1st
NOANo.:16-0811.11
Mu►Mtnab�cottNrY MpintionDate.:02/21/22
Approval Date:02109n7
Page 5 of 6
Page: 19 10/22/2019 06:44 AM TO: 17724621578 FROM:7722176820
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
39-31811
DO
M )
za-�rz"-sirr' �a-uzn-� �rzn
�j lass-4o mm) Asa-4a m) all gUde line
13- 1q 1AR' sg14'-sU4"
(146mm•159mm)
VZ-2-11r from boflanofshlogle
eif seal
adhesNe
on bask
ENHANCED NAILING PATTERN -six nails per shingle*
•required by some local codes and required for enhanced wind coverage on cedoin products,
see Smiled wartantyfordelaSs.
These shingles MUST be nailed a nominal 8"(152mm)from bottom of
of shingle,above the cut outs,as shown.mails must not be exposed.
END OF THIS ACCEPTANCE
90ANo.:16-0811.11
Ic4larrtflafofaoourm EupiratioaDate:02121/22
Approval Date:02/09/17