Loading...
HomeMy WebLinkAboutProduct Approval (2) i 10/22/2019 Florida Building Code Online SCIS Home ' Log In User Registration Hot TopicsM Submit Surcharge stats&Facts ( Publications j'rContact Us.�{ SCIS Site Map,E Links i �Searchgji rj011d3� Product Approval :USER:Public User ? n m Product AQoroval Menu>Product or ARpllcation Search>application Lig>Application History>Application Detail FL# FL11602-RS RECEIVED Application Type Revision Code Version 2017 Application Status Approved 0 C T 2 3 2019 ST. Lucie County, Permitting Comments Archived Product Manufacturer Owens Corning Roofing and Asphalt,LLC Address/Phone/Email One Owens Corning Parkway Toledo,QH 43645 (740)321-6345 Greg.Keeler@owenscornIng.com Authorized Signature Keeler Greg Greg.Keeler@owenscorning.com Technical Representative Greg Keeler t�,t/v oft Address/Phone/Email 2790 Columbus Road l `` m Granville,OH 43023 REvE � E (740) 321-6345 ,IMAGE greg.keeler@owenscorning.com '� �pw, A � 1 Quality Assurance Representative � ��.� ,, Address/Phone/Email lam' Category Roofing File !®PY Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA,Inc.-QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By John W.Knezevich,PE L Validation Checklist-Hardcopy Received Certificate of Independence . FL11602 R8 COI 2019 01 COI NIEMINEN Rdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D226(physicals) 2009 ASTM D4798 2011 FRSA/TRI April 2012 2012 TAS 117(8) 1995 Equivalence of Product Standards Certified By https://www.floddabuilding.org/pr/pr app_ U.aspx?param=wGEVXQwtDgsQFc5K%2frZeHYB7UCe5KMr93GSD6pGmnvY26rm5vhAMhgjQx8A%2fs... 1/2 10/22/2019 Florida Building Code Online Sections from the Code Product Approval Method Method I Option D Date Submitted - 06/20/2019 Date Validated 06/20/2019 Date Pending FBC Approval 06/22/2019 Date Approved 08/13/2019 Date Revised 08/I5/2019 Summa ry of Products FL#0Model,Number or Name Description 11602.1 Titanium Roof Underlayments Synthetic sheet-type roof underlayments Limits imits of Use Installation Instructions imir or U Approved for use in HVHZ:No FL11602 R8 11 2019 06 FINAL ER FL11602-R8.12d Approved for use outside HVHZ:Yes Verified By: Robert Nieminen PE-59166 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-45 Evaluation Reports Other: 1.)The design pressure noted herein pertains to use of FL 1602 R8 AE 2619 06 FINAL ER FL11602-R8.gd a specific underlayment system beneath foam-on the sytsems. Created by Independent Third Party:Yes Refer to ER Section 5.6.3 for details.2.)Refer to ER Sections 5 and 6 for other Limits of Use. Buck Next Contact Us 2601 Blair S$gne Road,Tallahassee FL 32399 phone;850-487-1824 The State of Florida is an AA/EEO employer.CjgRyjgljt 2007-2013 State of Florida ;;Privacy,Stement::AccessiblIlly,Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mall address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(l), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please dick here Product Approval Accepts: Qr it Qard hftps://www.floddabuilding.org/pr/pr�_app jfl.aspx?param=wGE\/XQwtDqsQFc5K�/�2fTrZeHYB7UCeBKMr93GSD6pGmnvY26rm5vhAMhqjQx8A`/*2fs... 2/2 NEMO etc. Certificate of Authorization#32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION Owens Corning Roofing and Asphalt,LLC Evaluation Report 111980.11.08-R9 One Owens Corning Parkway FL11602-118 Toledo,OH 43659 Date of Issuance:11/03/2008 (740)321-6345 Revision 9:06/20/2029 SCOPE: This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein. f DESCRIPTION: Titanium'Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.of any changes to the product(s),the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: a1"�;"� '%"r,;•; Robert J.M.Nieminen,P.E. '� �T�'-:' The facsimile seal appearing was authorized by Robert ',;< r� Nieminen,P.E.on 06/20/2019.This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 "�'. +4!"`' ,- electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a.financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. - 4. Robert Nieminen,P.E.does not have,nor will acquire,a finanpial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. NEMO etc. ROOFING COMPONENT EVALUATION: 1. Scopt: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TitaniumTM Roof Underlayments,as produced by Owens Corning Roofing and Asphalt,LLC, have demonstrated compliance with the intent of the following sections of the 61h Edition (2017) Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. e• Section Pro a :Standard Year 1507.1.1,R905.1.1 Exception Unrolling,Breaking Strength,Pliability ASTM D226 2009 1507.1.1,R905.1.1 Exception Tear Strength ASTM D1970 2015 1507.1.1,T1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012 TAS 110 Accelerated Weathering ASTM D4798 2011 TAS 110 Pull-through resistance TAS 117(B) 1995 3. REFERENCES: Entit Examination „ - Reference fate ERD(TST6049) Physical Properties 115010.04.09 04/29/2009 ERD(TST6049) Physical Properties 115010.05.10 05/14/2010 ERD(TST6049) Physical Properties 135520.06.11 06/15/2011 ERD(TST6049) ASTM D226 138010.08.11 08/11/2011 ERD(TST6049) Wind Uplift 135520.08.11-1 08/12/2011 ITS(TST1509) ASTM D226 311801000Q-003 04/26/2007 ITS(TST1509) ASTM D226 3130639COQ-002A 08/21/2007 ITS(TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS(TST1509) ASTM D226 101823107COQ-011 01/23/2015 ERD(TST6049) Physical Properties(NH) 4j-OC-19-SSUDL-01.A 06/14/2019 Owens Corning Product equivalency Declaration 06/18/2018 PRI(TST587a) ASTM D1970 OCF-341-02-01 09/20/2017 PRI(TST5878) ASTM D1970;Tear strength OCF-331-02-02 10/03/2017 PRI(TST5878) ASTM D1970;Tear strength OCF-332-02-02 10/03/2017 PRI(TST5878) ASTM D1970;Tear strength OCF-334-02-02 10/03/2017 PRI(TST5878) FRSA/TRI April 2012(04-12),partial OCF-343-02-01 11/09/2017 PRI(TST5878) ASTM D4798 OCF-341-02-01 11/27/2017 PRI(TST5878) TAS 117(B);Pull-through OCF-422-02-02 04/03/2018 PRI(TST5878) FRSA/TRI April 2012(04-12),partial OCF-425-02-01 08/13/2018 ITS(QUA3673) Quality Control ITS Listings Current ITS(QUA1673) Quality Control Service Confirmation 09/30/2017 ODDESCRIPTION: Product Saecfication Piant s Descrlgflon _ . ....... ._ _. ... _. 4.1 TitaniumTM PSU-30 ASTM D1970 Dubai,UAE& unreinforced polymer modified bitumen material adhered and FRSA/TRI Brentwood,NH to the underside of a polymer-coated,synthetic woven April 2012 sheet. The underside is backed with a release film. Unit weight 24 lbs/square 4.2 TitaniumTM'UDL-25 FBC 1507.1.1 Qingdao,China synthetic sheet-type underlayment comprised of a woven &R905.1.1 core coated on one side with a polymer coating. Unit (Exception) weight 2.5 lbs./square NEMO ETC,LLC Evaluation Report 111980.11.08-R9 Certificate of Authorization#32455 6m EDITION(2017)FBC NON-HVHZ EVALUATION F1.11602-118 Titanium Roof Underlayments Revision 9:06/20/2019 Page 2 of 8 MEMO l etc. ProductSpeclficatlon > Plants Descrlptlon 4.3 TitaniumTm UDL-30 FBC 1507.1.1 Mission,BC, synthetic sheet-type underlayment comprised of a woven &R905.1.1 Canada& core coated on both sides with a polymer coating. Unit (Exception) Qingdao,China weight 4.0 lbs./square 4.4 TitaniumTm UDL-50 FBC 1507.1.1 Mission,BC, synthetic sheet-type underlayment comprised of a woven &R905.1.1 Canada& core coated on both sides with a polymer coating. Unit (Exception) Qingdao,China weight 4.7 lbs./square :5. LimimioNs: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Titanium"'A Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: p � z , TABLE 1;' ROOF COVER OPTIONS �, e ,_. Asphalt Wood Shakes. Uriderlayment Shingles Nail On Tile Foam-On The Metal &Shingles .Slate Titanium PSU-30 Yes Yes Yes Yes Yes Yes Dubai UAE (See 5.5.1) Titanium PSU-30 Yes Yes No Yes Yes Yes (Brentwood,NH) Yes No No Yes Yes Yes I aurum Yes Yes Titanium UDL-30 Yes (Base Sheet Int-ply (Base Sheetln2-ply Yes Yes Yes system) system) Titanium UDL-50 Yes No No Yes Yes Yes 5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations. TABLE 1A ALLOWABLE TILE ADHESIVE UNDERLAYMENT COMBINATIONSi-' :Underlayment' Adhesive Florida Product Approval Dow TileBondw FL22525 Titanium PSU-30(Dubai,UAE) ICP Adhesives Polyset®AH-160 FL6332 I Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,LLC Evaluation Report 111980.11.08-R9 Certificate ojAuthorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL11602-R8 Titanium Roof Underlayments Revision 9:06/20/2019 Page 3 of 8 O. MEMO etc. 5.6 Allowable Substrates(for self-adhering): uS TABL���.,SUBSTRATE OPTIONS ,,< , Underlayment T Primer. Substrates (Optional)ASTM D41 plywood None ASTM D226 felt Titanium PSU-30 ASTM D41 Titanium UDL-30 None Titanium UDL-30(inverted) 5.6.1 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012(04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-45 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)ASTM D41 Underlayment: One or two plies,Titanium PSU-30 (Dubai, UAE), self-adhered and back-nailed max. 12" D.C. in accordance with Owens Corning Roofing and Asphalt,LLC published installation requirements. #2 Maximum Design Pressure=-30 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30(inverted) Fasteners: 12 ga.annular ring shank nails having not less than 20 rings per inch,heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min.32 ga.,1-5/8"diameter tin caps Spacing: 6-inch o.c.at 4-inch wide side laps and 12-inch D.C.at three(3),equally spaced center rows. Primer: ASTM D41 primer required at all tin-caps. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self-adhered and back-nailed max. 12" D.C. in accordance with Owens Corning Roofing and Asphalt,LLC published installation requirements. #3 Maximum Design Pressure=-30 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30(printed side up) Fasteners: 12 ga.annular ring shank nails having not less than 20 rings per inch,heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min.32 ga.,1-5/8"diameter tin caps. Spacing: 6-inch o.c.at 4-inch wide side laps and 12-inch D.C.at three(3),equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies,Titanium PSU 30 (Dubai, UAE), self-adhered and back-nailed max. 12" D.C. in accordance with Owens Corning Roofing and Asphalt,LLC published installation requirements. NEMO ETC,LLC Evaluation Report 111980.11.08-R9 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL11602-R8 Titanium Roof Underlayments Revision 9:06/20/2019 Page 4 of 8 ONEMO etc. #4 Maximum Design Pressure=-45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30(inverted) Fasteners: 12 ga.annular ring shank nails having not less than 20 rings per inch,heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min.32 ga.,1-5/8"diameter tin caps Spacing: 6-inch o.c.at 4-inch wide side laps and 8-inch o.c.at three(3),equally spaced center rows. Primer: ASTM D41 primer required at all tin-caps. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self-adhered and back-nailed 12" o.c. in accordance with Owens Corning Roofing and Asphalt,LLC published installation requirements. #5 Maximum Design Pressure=-45 Rsf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30(printed side up) Fasteners: 12 ga.annular ring shank nails having not less than 20 rings per inch,heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min.32 ga.,1-5/8"diameter tin caps. Spacing: 6-inch o.c.at 4-inch wide side laps and 8-inch o.c.at three(3),equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self-adhered and back-nailed 12" o.c. in accordance with Owens Corning Roofing and Asphalt,LLC published installation requirements. 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRl April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case,Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016)for Zone 2/3 enhancements.' 5.7 Exposure Limitations: Titanium UDL-25,Titanium UDL-30 or Titanium UDL-50 shall not be left exposed for longer than 30-days. Titanium PSU-30 shall not be left exposed for longer than 180-days. NEMO ETC,LLC Evaluation Report 111980.11.08-R9 certificate of Authorization#32455 6T"EDITION(2017)FeC NON-HVHZ EVALUATION FL11602-R8 Titanium Roof Underlayments Revision 9:06/20/2019 Page 5 of 8 NEMC} etc. 5.8 Tile Slippage limitations(per FRSA/TRI April 2012(04-12)1: When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. s TABLE'S:TILE SLIPPAGE Li1V1ITATloNS FOR DIRECT-DEtK TILE iNST ALtAT ONS ,' Underlayment . Tile Profile S#aging Method ":Maximum Slope Titanium PSU-30 Flat Max.10-tile stack 5:12 (Dubai, UAE) Lugged Max.10-tile stack 6:12 Flat Max.10-tile stack 5:12 Flat Max 5-tile stack 6:12 Lugged Max.10-tile stack 4:12 Lugged Max.5-tile stack 5:12 Max.10-tile stack(5 over 51 Titanium PSU-30 (Brentwood,NH) Lugged 5:12 `., •� 6.1 Titanium Roof Underlayments shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 TitaniuWm UDL725,Titanium U[7L-3Q or Titanium LlDL-50 6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or 11 underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed,considering the wider sheet-width. 6.3.2 Fasteners: Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with minimum 1-inch diameter plastic caps. Mechanical attachment of Titanium UDL-50 is limited to ring shank roofing nails with minimum 3/8-inch diameter heads;ring shank roofing nails with minimum 1-inch diameter plastic caps;screws and plates;or plastic cap staples. 6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails shall be required where the ultimate design wind speed, V,uit.equals or exceeds 150 mph." Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails in lieu of metal cap nails for these applications,when the Titanium'"'UDL-25,Titanium UDL-30 or Titanium UDL-50 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1. NEMO ETC,LCC Evaluation Report 111980.11.08-R9 Certificate ofAutharizotion#32455 a EDITION(2017)FBC NON-HVHZ EVALUATION F1.11602-118 Titanium Roof Underlayments Revision 9:06/20/2019 Page 6 of 8 NEMO etc. 6.3.3 Slopes of 4:12 or greater: End (vertical)laps shall be minimum 6-inches and side(horizontal) laps shall be minimum 4-inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. When batten systems are to be installed atop the underlayment,the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.4 Slopes of 2:12 to less than 4:12: End(vertical)laps shall be minimum 12-inches and side(horizontal)laps shall be minimum 25-inches. End(vertical) laps shall be offset from course to course not less than 6 feet. Begin by fastening a 25-inch wide strip along the eaves. Place a full-width sheet over the starter, completely overlapping the starter course. Continue upslope,maintaining minimum 25-inch side(horizontal)laps,resulting in a double-layer application. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4-inch o.c. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.4 Titanium'"PSU 30 6.4.1 Non-Tile Installations: Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed, and Owens Corning published requirements. Titanium"" PSU-30 shall be back-nailed max. 12" o.c. in accordance with Owens Corning published installation requirements. 6.4.2 Nail-On Tile Applications: Shall be installed in compliance with the requirements for Self-Adhered Membrane underlayment set forth in FRSA/TRI April 2012(04-12),and Owens Corning published requirements. TitaniumTM'PSU-30 shall be back-nailed max.12"o.c.in accordance with Owens Corning published installation requirements. Refer to Section 5.8 for tile staging limitations. 6.4.3 Foam-On Tile Applications[Titanium PSU-30(Dubai, UAE)onlyl: Shall be installed in compliance with the requirements for Self-Adhered Membrane underlayment set forth in FRSA/TRI April 2012(04-12),and Owens Corning published requirements.Titanium1m PSU-30 shall be back-nailed max. 12"o.c.in accordance with Owens Corning published installation requirements. Refer to Table 1A for allowable tile adhesives. Refer to Section 5.6.1 for wind uplift limitations. Refer to Section 5.8 for tile staging limitations. 6.5Ttaniu'm2 Ply System: 6.5.1 The Titanium 2-Ply System consists of a base layer'of Titanium UDL-30 (top-surface-. { primed or sheet inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30,self-adhered. 6.5.2 Non-Tile Applications: Install Titanium UDL-30(top surface primed or sheet inverted)in accordance with Section 6.3 followed by Titanium PSU-30 in accordance with Section 6.4. NEMO ETC,LLC Evaluation Report 111980.11.08-R9 Certificate of Authorization#32455 6P EDITION(2017)FBC NON-HVHZ EVALUATION F1.11602-118 Titanium Roof Underlayments Revision 9:06/20/2019 Page 7 of 8 O. NEMOjetc. 6.5.3 Nail-On Tile Applications: For nail-on tile installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with FRSA/TRI April 2012(04-12),using Section 6.3 as a guide,and considering the wider sheet width relative to ASTM D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4. Refer to Section 5.8 for tile staging limitations. 6.5.4 Foam-On Tile Applications[Titanium PSU-30(Dubai, UAE)onlyl: For foam-on the installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 5.6.1 herein. Then apply Titanium PSU-30 in accordance with Section 6.4 Refer to Table 1A for allowable tile adhesives. Refer to Section 5.6.1 for wind uplift limitations. Refer to Section 5.8 for tile staging limitations. REQUIREMENTS:7. RUILDING PERMIT 71 As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the manufacturer or the named C!A entitfor s c y plantovered under Rule 61G20-3 QA requirements. Refer to Section 4 herein for product&production locations having met codified physical properties specifications. QU'ALrrY ASSURANCE ENTITY: Intertek Testing Services NA Inc.—QUA1673;(604)520-3321 -END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 111980.11.08-R9 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL11602-R8 Titanium Roof Underlayments Revision 9:06/20/2019 Page 8 of 8