Loading...
HomeMy WebLinkAboutProduct Approval 6/25/2019 Florida Building Code Online a • e BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts I Publications Contact Us BCIS Site Map' Links Search. 1WCjd " Product Approval USER:Public User :' iisaArtixu Product Approval.Menu>Product or Application Search>epolPcation List>Application Detail FL# FL10674-1113 RECEIVE® Application Type Revision Code Version 2017 OCT 2 4 '009 Application Status Approved 'ST, tuc(e County, Permitting Comments Archived f" Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owensdorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ._i Evaluation Report-Hardcopy Received a Florida Engineer or Architect Name who developed the Robert J.M. Nieminen 'w Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 �# ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQWtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEBFhs7tvJgZew%3d%3d 1/2 6125/2019 Florida Building Code Online Product Approval Method Method 1 Option D k Date Submitted 10/10/2017 Date Validated 10/11/2017 Date Pending F9C Approval 10/15/2017 Date.Approved 12/12/2017 Date Revised 06/13/2019 r r .mss ", rm ;,. '` FLkca MOtIe1r TI1i14beC b�' dtit� a v � Dnpp��I�t(�IY W �" fi aY,,....� rs. 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles Shingles and Starters Limits of Use Installation Instructions " Approved for use in HVHZ:No FL10674 R13 II 2017 10 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pdf Impact Resistant: N/A Verified By: Robert]. M. Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party:Yes Other:Refer to ER,Section S. Evaluation Reports FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT SHINGLES FL10674-R13.p�df Created by Independent Third Party: Yes Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.f2pyQght 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please-contact 850.487.1395.*Pursuant to Section 455.275(1), y Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.;please click here.. Product Approval Accepts: rw Credit Card Safe o https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEBFhs7tvJgZew%3d%3d 212 EXTERIOR RESEARCH&DESIGN,LLC. Certificate cifAuthorization#9503 TR1N1-ff 353 CHRISTIAN STREET,UNIT#13 IERD OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R8 One Owens Corning Parkway FL10674-1133 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6ch Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R90S.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: ,us4irrr;r+b, _ y Robert J.M.Nieminen,P.E. t•.,,Sg�'`•.."o The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 't�✓++rir����� Nieminen,P.E.on 10/09/2017.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY 1 ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme*are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire TM are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration*, TruDefinition0 Duration*, Duration* Premium Cool, TruDefinition* Duration* Designer Color Collection, Tru Definition*Oakridge, Oakridge* and WeatherGuard* HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard* HP Hip 8i Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge'"" Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting.or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RI} Certificate afAuthoriration#9503 fjTM EDITION(2017)FBC NON-HVHZ EVALUATION FL10674413 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 TR1N.iTY j ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in all wind zones up to V,,d = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class.F, indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph (V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3,and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.1,1507.2.4 or R905.2.3. 6.2 Asphalt Shinsles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: Berkshire shingles require minimum five(5)nails per shingle. WeatherGuard'HP shingles require minimum six(6)nails per shingle. Devonshire7m shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Feltunderlayment Deck Fettatvlerla>nnens Deck SeWhered Sell-adhered. umkde"fd Weatherloeke underiaMent DriDrip edge edge Dr �Ved9e Nails located ' ++? dul lxatad 2'-d'hom care 2-3'from save Install first �tirststarterS*P4s Starter Strip �positionalong save shinglekvith whhtt'removed�r' 6"removed Starter Strip shingle overhangs eaves and rakes Stertor P Pku owrhsnga eves and rakes 1/4-3/4' Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 r EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 TRINITY J ERD 6.2.6 Minimum Nailing—Classic®&Supreme: 17u" l Mansard or Areapara Normal Mansard or Area pan reas High Wind desvanaa y Wind Arena Nigh Wlnd davvenas y ara vientos Aormates Araas VTatlYoa taaltea Area para-wenfoa norma/es Args vionroa fuartaa a (A) �g rz r r iAl �' t' 2' IB z' �' •r �r t2 T 5•Exposure 65/8'Exposure Expoaiaidn lekpOiriCldn 6.2.7 Minimum Nailing—Berkshire®: SealaM.sttip Sealant strip La tl+ada seRadar /!a Ura de sedfada l�<---/1 1---► a Fes►. ft---"!•• •r--r —! • •�--�a�----.• 9 IT 8 vef ,8 Vt" 8 4t' 8 1 1•J 1 Standard Fastening Pattern 6-Nail Fastening Pattern Sealant strip La ika do sOk*r «---►a t—►• a�---►a t--�e Yr '8 11t, 8?/t' 8 Yr t" r 2" dsphaltroofingcemerit tAmwto da ochoda astafto Mansard or Steep Slope Fastening Pattern Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R8 Certficate ofAuthodiddon#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674.1113 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 �, TRINrryj ERD 6.2.8 Minimum Nailing—Devonshire'"': 1y.1 7w 8" 8w 8" 7" • Clam (dans • � r r e r 53/8°exposure Saafatlt location } 5 Fxposi6n de 6^5!8 pnlg Ubicatibn del sellador Ten 1"Spots of Asphait Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition' Duration Designer Color Collection: 4 t1ei1 Fastening Pattern ►tall Fastening Pattern 9+renat�rasbnho ana wirsh Smet�ad®tasleNnp area wiQtlr ULTYplol - t1a9.Typiml t^ tr tr t• t^ tr tr &tA^yyg" ., r az 6110"Sag ✓': �� ���� Standard Fastening Pattern 6-Nail Fastening Pattern Faetedln4 W Slopes Greats Than.21:12 . BweNFA®tosentag area isWM t• it tr �. . Cita•sve- - 01 r Fav t'apoh NAsphe4ReoM1p tiv.M Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate ojAuthorization 49503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 F)o TRINITY,ERD 6.2.1 Minimum Nailing—Tru Definition Oakridge®,Oakridge®: 4 Nail Pattern 6'Nall Oitttem Esgriema von 4 clavos Esquema coir 6 clavas r' r t' T IF— ic' -->I ti'—� 5518"Exposure Nails b 5/8.Exposure pb� Expmidtin de 55/Spatg. Cbvcs Exposci¢a de.55/8pufg. 55/8"ExposureClavus 5 5/8'Wow &posfark de 5518 ptdg Exposicrda:de b 518 ping. Standard Fastening Pattern 6-Nail Fastening Pattern FaateNn9 for Stopes Greater Than 21:12 8wenaa8[auMnp era wWN Neo tYP� W ,,, � N 41- +& .� a, vaa 7-Spon*apnea rmoma C-4 Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: 1' 1. iiapl�+_i1e4.11Mw ,•.fir, ns .,.,�., s;{: ':•:S; 114mu.i Ymmq*Nil Lkw Cwi��r7fir i:tlFdOr. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate ofAuthoriration#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 F)o TRINITY I ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire® Hip and Ridge Shingles, High Ridge, WeatherGuard® HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for Wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 4 VNntl Fig.2 PrevaFlhlg Dueabn p TOPkieA SItleMew A Naps Nails Nails— --^—l4 p...z• 2-, t \\\\ / TOP Lamamtetl \! � 'A 1 I 4' Poece 4 I I I I I �Expasare I vl Y I I- I 11-12" 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: q 4 Fig.C Hip&Ridge Shingle•Fastenin Fig.A g PMvaghg Wind /�� topVlaW A Nalls-- _�—`>44 Naps Nails P , T <Q � I I 7, a„ . a• 6" �osu� _ - \ V, Enpowre Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate ofAuthori:ation#9503 6TN EDITION(2017)FBC NON-HVH2 EVALUATION F1.10674-1113 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 '\,]' TRINITY 1 ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing (Standard -99„— Wind.Direction f�atternirection Fastening � u• 1 - Sea{atrt d 'y 61 Expwm r J A 1 * Fsitea 71h' '��:� Cover E�oaed Roof Cccliant f'��2�—,� 6.3.6 Minimum Nailing—DuraRidgel Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Tapvift on Vkw 0iraed6c� dcnea�dmdmatn 40 . 1 I ml b 1 I I 1 I rIN,. 34 t — 1; I 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9, MAN UFACTURING'PLANTS: Contact the named O,A entity for information on which plants produce products covered by Florida Rule 9N-3 CIA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6'”EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8