Loading...
HomeMy WebLinkAboutProduct Approval 10/10/2019 Florida Building Code Online BuSiness Pr6fespionale SCIS Home I Log In i User Registration i Hot Topics I Submit Surcharge I stats&Facts I Publications I Contact Us i SCIS Site Map'I Unks I Search are Product Approval USER:Public User Product Aooroval Menu>Product or Application Search>Appllotian List>Application Detail II FL# FL5325-117 Application Type Revision Code Version 2017 RECEIVED Application Status Approved OCT 2 �iq Comments Archived 0 ST; WPM C_WMY, permitting ' Product Manufacturer SDP Advanced Polymer Products,Inc. Address/Phone/Email 410-130 Bridgeland Ave Toronto,NON-US (866)747-4035 Ext 4 sdipede@sdp-products.com as File, Coli Authorized Signature Sandro Di Pede sdipede@sdp-products.com Technical Representative Sandro Dl Pede Address/Phone/Email 410-130 Bridgeland Ave Toronto (416)780-1700 sandrodipede@belinet.ca Quality Assurance Representative Sandro DI Pede Address/Phone/Email 410-130 Bridgeland Ave REVIEW FOR Toronto s780-1700 and odipede@bellnet.ca CODE COMPLIANCE ST. LUOIE COUNTY Category Roofing ��� Subcategory Underiayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer (] Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-54166 Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 12/31/2020 Validated By John W.Knezevich;PE t,f Validation Checklist-Hardcopy Received Certificate of Independence FL5325 R7 COI 2017 01 COI Nleminen.D f Referenced Standard and Year(of Standard) Equivalence of Product Standards Certified By Sections from the Code 1507.1.1 1507.2.9.2 https-//www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvBaw2gXbdthvuV98c7lHpC51glWSkerM8°/a3d 1/2 10/10/2019 Florida Building Code Online 1518.4 TAS 110 Product Approval Method Method 2 Option B Date Submitted 10/12/2017 Date Validated 10/14/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products PFL# Model,Number or Name Description PALISADE Roofing Underlayments Synthetic Roofing Underlayments of Use Installation Instructions ed for use in HVHZ:Yes FL5325 R7 II 2017 10 FINAL ER SDP UNDERLAYMENTS FL5325- ved for use outside HVHZ:Yes R7 pdf Impact Resistant:N/A Verified By: Robert Nleminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other: 1.)PALISADE Is for use In non-HVHZ and HVHZ Evaluation Reports jurisdictions.2.)PALISADE SA-HT is not for use in FL5325 R7 AE 2017 10 FINAL ER SDP UNDERLAYMENTS FL5325- HVHZ.3.)Refer to ER Section 5 for Limits of Use. R7.pdf Created by Independent Third Party:Yes Back Poext Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Cogyrlght 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: ® eChcik M Credit Card Safe https://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvBaw2gXbdthvuV98c7lHpC51glWSkerM8°/a3d 212 EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate of Authorization#9503 TRINITY I ERD 353 CHRISTIAN STREET,UNIT#13 OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT SDP Advanced Polymer Products,Inc. Evaluation Report 519010.07.09-113 410-130 Bridgeland Avenue FL5325-R7 Toronto,Ontario M6A 1Z4 Canada Date of Issuance:07/03/2009 (866)747-4035 Revision 3:10/12/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: PALISADE'""Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: Robert J.M.Nieminen,P.E. ��-.` ;' -e> ;� � �,•.,���F��q�O;{_;;' The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 �.'•,Ss+o�a0;;:� Nieminen,P.E.on 10/12/2017.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. J VT___R1N1TYJ ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: PALISADETM'Roof Underlayments, as produced by SDP Advanced Polymer Products, Inc., have demonstrated compliance with the intent of the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.1.1,T1507.1.1,1518.4 Unrolling,Breaking Strength,Pliability ASTM D226 2009 1507.1.1(Exception) Tear Strength ASTM D1970 2015 1507.1.1,T1507.1.1, Physical properties ASTM D1970 2015 1507.2.9.2,TAS 110 1518.4 Unrolling,Pliability,Behavior on ASTM D2626 2004 Heating,Breaking Strength,Water Vapor Permeance 1523.6.5.2.9,TAS 110 Comparative Rupture TAS 117,Appendix B 1995 TAS 110 Accelerated Weathering ASTM D4798-11 2000 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) Physical Properties 54240.10.06 10/03/2006 ERD(TST6049) Physical Properties&Rupture SO404C.12.05-R2 02/23/2009 ERD(TST6049) Accelerated Weathering 537000.06.11 06/14/2011 ERD(TST6049) Tear strength SDP-SC16495.17 10/11/2017 ICC-ES(EVL2396) IBC/IRC Compliance ESR-1847 03/01/2017 Miami-Dade(CER1592) HVHZ Compliance 16-1025.02 11/10/2016 QAI(QUA7628) Quality Control Service confirmation 09/28/2017 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlayments: 4.1.1 PALISADETM'is a synthetic roofing underlayment comprised of a polyolefin-coated,woven construction with dual skid resistant surfaces; meets FBC 1507.1.1 (Exception) and Miami-Dade requirements for synthetic roof underlayment.PALISADE''is acceptable for use in non-HVHZ and HVHZ jurisdictions. Refer to Limits of Use herein. 4.2 Self-Adhering Underlayments: 4.2.1 PALISADETM SA-HT is a self-adhering roofing underlayment comprised of a polyolefin-coated, woven construction with skid resistant upper surface and self-adhering bottom surface. PALISADETM'SA-HT is not for use in FBC HVHZ jurisdictions. Refer to Limits of Use herein. Meets physical requirements of ASTM D1970(See Section 5.2.6). S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose 5.2 Non-HVHZ Jurisdictions: 5.2.1 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 519010.07.09-R3 Certificate o/Authorization#9503 CH EDITION(2017)FBC NON-HVHZ&HVHZ EVALUATION FL5325-117 PALISADE'"Roof Underlayments;(866)747-4035 Revision 3:10/12/2017 Page 2 of 5 ��TRINITYJ ERD 5.2.2 PALISADE' Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.2.3 Allowable Roof Covers: Table 1: Roof Cover Options Underlayment Asphalt Nail-On Tile Foam-On Metal Wood Shakes Slate Shingles Tile &Shingles Yes PALISADE'" Yes (Base sheet In 2- No Yes Yes Yes ply system) PALISADETM SA-HT Yes No No Yes Yes Yes 5.2.4 Allowable Substrates: PALISADE'SA-HT adhered to plywood or to mechanically attached PALISADE"'. 5.2.5 Exposure Limitations: PALISADE"'shall not be left exposed for longer than 180-days after installation. PALISADE""SA-HT shall not be left exposed for longer than 30-days after installation 5.2.6 Agreement between purchaser and seller,as set forth in Section 4.3, Note 1 of ASTM D1970-15,should be established as to slip resistance of PALISADE""SA-HT. 5.3 HVHZ Jurisdictions: 5.3.1 PALISADE"'SA-HT is not for use in HVHZ. 5.3.2 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3.3 This Evaluation is for prepared roofing applications. Minimum deck requirements shall be compliant with applicable FBC sections. 5.3.4 PALISADEm shall not be applied in hot asphalt. 5.3.5 PALISADE"' shall be installed in strict compliance with the requirements for ASTM D226,Type 11 or ASTM D2626 underlayment in FBC HVHZ 1518 for the type of prepared roof covering to be installed. 5.3.6 PALISADE"' may be used with asphalt shingles,tile roofs (Base Sheet in 2-ply system only), non-structural metal roofing/metal shingles,quarry slate,slate-type shingles and wood shakes&shingles. For tile roof applications, PALISADE"'shall be mechanically attached as an anchor sheet in accordance with Section 6.4 herein,followed by Tamko TW Metal and Tile Underlayment(NOA 17-0530.12)or CertainTeed Flintlastic SA Cap(NOA 14-1028.02). 5.3.7 If PALISADETM' is not specifically listed in the prepared roof covering FBC HVHZ Product Approval or NOA, this report may be submitted to the Authority Having Jurisdiction or Miami-Dade Product Control Dept., along with fire classification information,for their consideration. 5.3.8 PALISADE""underlayment shall not be left exposed for longer than 180-days after installation. 5.4 All products listed herein shall have quality assurance audit in accordance with F.A.C. Rule 611320-3 requirements. Exterior Research and Design,LLC. Evaluation Report S19010.07.09-R3 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ&HVHZ EVALUATION FL5325-R7 PALISADE`"Roof Underlayments;(866)747-4035 Revision 3:10/12/2017 Page 3 of 5 1 ��TRINI-rYJERD 6. INSTALLATION: 6.1 PALISADET Roof Underlayments shall be installed in accordance with SDP Advanced Polymer Products, Inc. published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate with Elastocol Stick. 6.3 Non-HVHZ Jurisdictions: 6.3.1 PALISADEI: 6.3.1.1 Shall be installed in compliance with the requirements for ASTM D226,Type I or If underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed,taking into account the wider sheet- width for double-layer applications. 6.3.1.2 Non-Tile Applications: PALISADET is installed horizontally with the printed side up, and with 3-inch horizontal laps and 6-inch vertical laps.Overlaps must run with the flow of the water in a shingle pattern.The underlayment is only attached to the roof deck with roofing nails(smooth or ring-shanked)compliant with FBC 1507.2.6 having 1-inch minimum diameter plastic or steel caps. Cap nails are spaced at 6 inches on center at vertical laps, and at 11 inches on center at horizontal laps. In the field area, apply fasteners at 13 inches spaced vertically and 22 inches on center horizontally. All caps (including nails) must be fully flush with the underlayment surface. Do not install fasteners over unsupported areas/voids. Repair all tears, holes, or damage to the underlayment. For slopes less than 4:12,use a full 20"half lap over the underlying course. Apply underlayment up all abutments at least 6 inches. In non-HVHZ high wind regions where V„It > 181 mph (Vasd > 140 mph) or exposure beyond 30 days, increase the fastener density to cap nails spaced 3 inches on center at vertical laps, and at 5.5 inches on center at horizontal laps.In the field area,apply fasteners at 6.5 inches spaced vertically and 11 inches on center horizontally.In addition,secure laps by folding all laps over before nailing,or taping securely across lap seams using exterior grade sheathing tape,or sealants such as roofing cement(asbestos free meeting ASTMD4586),EPDM or butyl to seal laps. 6.3.1.3 Nail-On Tile Applications,Base Sheet in 2 Ply System: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein using PALISADETm as the mechanically attached base ply in a 2 ply underlayment system,followed by Tamko TW Metal and Tile Underlayment(FL12328)or CertainTeed Flintlastic SA Cap(FL11288)as the top layer. For mechanically fastened tile roofing, refer to SDP Advanced Polymer Products published installation instructions,but not less than the fastener density from FRSA/TRI April 2012(04-12),Table 1. 6.3.2 PALISADE SA-HTT"': 6.3.2.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. SDP Advanced Polymer Products requires that the installer be responsible to determine whether priming is required to ensure PALISADE'"'SA-HT will stay adhered to the substrate. 6.3.2.2 Non-Tile Applications: PALISADE SA-HT1 is installed horizontally with the printed side up,and with 3-inch horizontal laps and 6- inch vertical laps.Starting at the low point,and with salvage edge at the high point,position horizontally a full roll or cut the membrane into 10-15 ft. (3-5m) lengths and re—roll loosely. Peel back 1-2 ft. (300- 600mm) of release film,align the membrane,and continue to peel the release film from the membrane. Press the membrane in place with heavy hand pressure.Apply uniform pressure to the membrane roll side and end laps to insure water tightness and bonding to the substrate. Exterior Research and Design,I.I.C. Evaluation Report S39010.07.09-R3 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ&HVHZ EVALUATION FL5325-R7 PAUSADE-Roof Underlayments;(866)747-4035 Revision 3:10/12/2017 Page 4 of 5 TRINITY I ERD Always work from the low to the high point of the roof. Follow good roofing practice by orientating PALISADE-SA-HT'"' so side laps shed water. Apply the membrane in valleys before the membrane is applied to the eaves. For valley and ridge application, peel the release film; center the sheet over the valley or ridge, drape, and press into in place. Work the center of the valley or ridge outward in each direction.Following placement along the eaves,continue application of the membrane up slope.If nailing of the membrane is necessary on steep slopes, especially during hot or cold weather, back nail and cover the nails by overlapping with the next sheet. 6.4 HVHZ Jurisdictions: 6.4.1 System E(1): Underlayment mechanically fastened to deck Deck Type 1: Wood,Non-Insulated Deck Description: Min.19/32"plywood or wood plank Underlayment: One or more plies of PALISADETm with minimum 4"wide head laps and minimum 6" wide end laps,mechanically fastened to deck. Fastening: FBC HVHZ Approved (FBC HVHZ 1517.5) nails and tin caps 6" o.c. at lap and three equally spaced staggered rows 12"o.c.in the field. Surfacing: FBC HVHZ Approved asphalt shingle, non-structural metal, wood shakes& shingles or slate. 6.4.2 System E(2): Base underlavment mechanically fastened to deck top laver adhered Deck Type 1: Wood,Non-Insulated Deck Description: Min.19/32"plywood or wood plank Base Layer: One or more plies of PALISADETM'with minimum 4"wide head laps and minimum 6" wide end laps,mechanically fastened to deck. Fastening: FBC HVHZ Approved (FBC HVHZ 1517.5) nails and tin caps 6" o.c. at lap and three equally spaced staggered rows 12"o.c.in the field. Top Layer: Tamko TW Metal and Tile Underlayment (NOA 17-0530.12) or CertainTeed Flintlastic SA Cap(NOA 14-1028.02),self-adhered to the base layer. See current FBC HVHZ approval for installation guidelines and limits of use of top layer. Surfacing: FBC HVHZ Approved asphalt shingle, non-structural metal,wood shakes&shingles, slate or tile. Note: For tile applications, Authority Having Jurisdiction shall verify that top layer underlayments listed herein hold current FBC HVHZ Product Approval and/or Miami- Dade NOA for use as a tile underlayment. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Shandong,China 9. QUALITY ASSURANCE ENTITY: QAI Laboratories—QUA7628;(604)527-8378;miansdowne@qai.org -END OF EVALUATION REPORT- Exterior Research and Design,U.C. Evaluation Report 539010.07.09-R3 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ&HVHZ EVALUATION FL5325-R7 PALISADE-Roof Underlayments;(866)747-4035 Revision 3:10/12/2017 Page 5 of 5