HomeMy WebLinkAboutNOA t �
I I
j flI
R�cE�Fp MIAMI-DADE COUNTY
MIAMI-RADE oet PRODUCT CONTROL SECTION
Per 2°�?�J,g 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RE R�St��1n9 pe Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION �Ue�e cov QnF T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
GAF
1 Campus Drive
Parsippany,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.'The
documentation submitted has.been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the'AHJ may immediately revoke,modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section thatthis product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
�I
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Royal Sovereigno Shingle
i
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
I
i
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
i
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any,section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user,by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA 14-1022.16 and consists of pages 1 through 4.
�i
The submitted documentation was reviewed by Freddy Semino M
NOA No.: 18-0123.06
MiaMIoAoe coutvrir Expiration Date: 04/22/23
Approval Date:03/01/18
Page 1 of 4
- f ,
i
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials 3-Tab !
Deck Ty
pe• Woad
SCOPE
This approves GAF Royal Sovereign'Shingle as manufactured by GAF as described in this Notice of Acceptance,
designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building
Code. i
.r
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GAF Royal Sovereign*Shingle 12"x 36" TAS 110 Fiberglas reinforced heavy weight asphalt roof
shingle,with a 3-Tab profile
MANUFACTURING LOCATIONS
1. Savannah, GA.
2. Tampa,FL.
3. Mt.Vernon,IN.
i
4. Mobile,AL.
5. Dallas,TX.
6. Myerstown,PA.
7. Fontana,CA. 1
}
EVIDENCE SUBMITTED !
,C
Test Agency Test Identifier Test Name/Report Date
PRI Construction Materials Technologies,Inc. TAS 100 GAF-332-02-01 01/-17/12
TAS 100 GAF--376-02-01 10/15/12
Underwriters Laboratories,Inc. TAS 107 08NK02337 03/12/08
TAS 107 08NK12906 10/10/08
TAS 107 11CA47919 12/03/11
ASTM D 3161 /TAS 107 09CA41642 09/28/10
ASTM D 3161 /TAS 107 09CA38549 10/30/09
ASTM D 3462 08NK02337 03/112/08
ASTM D 3462 09CA21715 05/20/09
ASTM D 3462 08CA61515 07/15/09
ASTM D 3462' 11CA47919 12'!03!11
ASTM D 3462 4788199685 12/20/17
ASTM D 3462 4788199685 01103/18
i
MfAMI•DADE CO• � . -
NOA No.: 18-0123.06
Expiration Date:04/22/23
Approval Date: 03/01/18
I
Page 2 of 4
1
i
I ! l
i
LIMITATIONS
1.- Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installedon roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Applications Standard RAS 115.
2. Flashing shall be in accordance with Roofing Applications Standard RAS 115.
3. The manufacturer shall provide clearly written application instruction.
4. Exposure and course layout shall be in compliance with Detail"A", attached.
5. Nailing shall be in compliance with Detail`B",attached.
I
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer.'s name or logo, city and state of i
manufacturing facility,and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dad_e
County Product Control Seal as shown below.
MIAMI-DARE COUNTY
]BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Oficial or the applicable code in order to I roperly
evaluate the installation of this system.
i
j
j
'i
i ill
NOA No.: 18-0123.06
MwMunADE COUNrir Expiration Date:04/22/23
1 Approval Date:03/01/18
i. Page 3 of 4
'I
i
I
i 1
DETAIL A
COURSE LAYOUT
1st Course of Shingles
I I
2nd Course of Shingles
3rd Course of Shingles
t
1
5"
71•
5"
Drip Edge
I
'I
DETAIL B j
OVERALL DIMENSIONS AND NAILING PATTERN
36"
i
i
i
CV
n
co
In I I up
I
i
END OF THIS ACCEPTANCE
'I
'i
I
I
1
NOA No.: 18-0123.06
MIAMbDADE COUNTY +
Expiration Date:04/22/23
Approval Date:03/01/18
Page 4 of 4
i
_ t
t
MIAMi•DuADE ! Oct ,, MIAMI-DADE COUNTY
r ?Ofg PRODUCT CONTROL SECTION
Per
m��';nePa g p 11805 SW 26 Street,Room 208
St.
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 'UQe coon)est Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION ry T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.goy/economy
SOPREMA,Inc. (Canada)
1688 Jean-Berchmans-Michaud
Drummondville,Quebec J2C OC2 Canada
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.;The
documentation submitted has been reviewed and accepted by-Miami-Dade County RER-Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this
acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Soprema Lastobond,EnviroShield and Resisto Underlayment Products
I
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
i
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.-
ADVERTISEMENT:
OA.ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall:be
done in its entirety.
i
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 15-0508.04 and consists of pages 1 through 7. j
The submitted documentation was reviewed by Hamley Pacheco,P.E.
NOA No.: 1�8-0329.03
MIAMI-DADECOUNTY i ExpirationDate:� 09/29/20
i
Approval Date:06/28/18
! Page 1 of 7
i
i
i
i(
ROOFING COMPONENT APPROVAL
Category: Roofing, ,,-
Sub-Category: Underlayment
Materials:_ SBS
SCOPE: j
This acceptance is for Soprema Lastobond,EnviroShield and Resisto'Underlayment Products as manufactured by
SOPREMA Inc.,as described in this Notice of Acceptance,for use with approved prepared roof assemblies as
described in this Notice of Acceptance;designed to comply with the Florida Building Code, including the-High
Velocity Hurricane Zone of the Florida Building Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
c
Lastobond Shield 36"x 75' rolls ASTM D 1970 SBS self-adhereing asphalt sheet material for use
Manufacturing Location #1 or as an underlayment for Ice Dam Protection in
45"x 75' rolls sloable as Lastobond
ped roof assemblies. **Avail
Shield 36 and Lastobond Shield 45 for the136"
wide and 45"wide rolls.
I
Lastobond Pro HT-N 36"x 65' rolls ASTM D1970 SBS.self-adhering asphalt sheet material for use as
Manufacturing Location #1 . an underlayment for Ice Dam Protection in sloped
roof assemblies.
Resisto SA Smooth Ply 40 40"x 65'rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as
Manufacturing Location #1 an underlayment for Ice Dam Protection in sloped
roof assemblies.
i
Lastobond Shield HT 36"x 75' rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as
Manufacturing Location #1 an underlayment for Ice Dam Protection in sloped
roof assemblies.
Lastobond Pro HT-S 36"x 65' rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as
Manufacturing Location #1 an underlayment for Ice Dam Protection in sloped
roof assemblies.
I
EnviroShield 36"x 65' rolls ASTM D1970 SBS self-adhering asphalt sheet material use as
Manufacturing Location #1 an underlayment for Ice Dam Protection in sloped
roof assemblies. {
Lastobond 195 36"x 75' rolls ASTM D1970 Self-adhering glass-fleece reinforced, SBS
Manufacturing Location #1=.3 modified bitumen roofing underlayment.;i
Resisto LB1236 " 36"x 65' rolls ASTM D1970 Self-adhering-glass fleece reinforced, SBS
Manufacturing Location #1-3 modified bitumen roofing underlayment.
4 NOA No.: 18-0329.03
MIAMtDADECDUhITY
_ Expiration Date.: 09/29/20
Approval Date:06/28/18
Page 2 of 7
:
TRADE NAMES'OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
J Test Product
Product + Dimensions Specification Description
Resisto LB1244 44"x 75' rolls ASTM D1970 Self-adhering glass fleece reinforced, SBS ;I
Manufacturing Location #1-3'.:: modified bitumen roofing underlayment.
Lastobond Eaves Protection; 36"x 75' rolls ASTM D1970 Self-adhering glass fleece reinforced, SBS
Sheet modified bitumen roofing underlayment. f
Manufacturing Location #1-3,
Lastobond Smooth Seal HTi 36"x 65' rolls ASTM D1970 Self-adhering glass fleece reinforced,elastomeric
Manufacturing Location #1-3 - bitumen roofing underlayment.,
Lastobond TU HT 393/81,x 65 3/5' TAS 103-and Self-adhering glass fleece reinforced, SBS,;
Manufacturing Location #3 rolls ASTM D 1970 modified bitumen roofing underlayment.
j-.
i
MANUFACTURING LOCATION:
1. Drummondville, Quebec(Canada)
2. Wadsworth,-OH r
3. Gulport,MS
,i
'I
EVIDENCE SUBMITTED:
.i
Test Aaency Test Identifier Test Name/Report Date
Underwriters Laboratories,Ina R21824 UL790 09/11/15
Trinity I ERD SOPC-SC8970.08.15 ASTM D1970/TAS 110 08/31/15
S31370.03.10-1-R1 ASTM D1970 64/07/10
S37210.11.11 ASTM D1970 111/09/11
S37210.12.11 ASTM D1970 12/01/11
S40540.02.13-1 ASTM D1970 02/19/13
S40540.11.13 ASTM D1970 111/19/13
543530.02.14-1-R1 TAS 103 65/14/14
S44870.04.14-4 ASTM D1970 04/10/14
544870.04.14-1 ASTM D1970 04/10/14
S44870.04.14-3 ASTM D1970 014/02/14
S44870.04.14-2 ASTM D1970 04/02/14
S40540.10.14 ASTM D1970 10/31/14
SOPC-SC8520.04.15 TAS 103 04/27/15
- i
i
i
,1
i1
i
i
1 - I
NOA No.: 18-0329.03
MIAMMADE COUNTY
Expiration Date•. 09/29/20-
Approval Date:06/28/18
Page 3 of 7
I '
j
II
i
f
APPROVED ASSEMBLIES:
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32"or greater plywood or wood plank
System E(1): Base sheet mechanically fastened,membrane adhered.
i
Base Sheet: One or more plies of ASTM D226 Type 11 or ASTM D2626 with a minimum 4"side lap and
a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at.the
laps and two staggered rows 12"o.c.the field of the roll.
Membrane: One ply of Lastobond Shield,Lastobond Pro HT N,Resisto SA Smooth Ply 40,Lastobond
Shield HT,Lastobond Pro HT-S,EnviroShield,Lastobond TU HT,Lastobond 195,
Lastobond Eaves Protection Sheet, Lastobond Smooth Seal HT,Resisto LB1236 or Resisto
LB1244 with minimum 3-inch side laps and 6-inch end laps. Starting at the first course,
parallel to the eave, align the membrane carefully by completely unrolling and setting;it
exactly where it will be installed. Once aligned,rewind one half of the length. Gently score
the release paper on the high side of this roll,'ensuring not to cut through the membrane's
thickness. Unroll this first half by evenly peeling back the release paper while
simultaneously and slowly pushing out the membrane. Repeat process for remaining one
half of the length. Once installed, the membrane must be pressure rolled with a metal or
rubber roller. Pressure shall be applied over'the entire surface,paying particular attention to
all side and end laps.
Surfacing: Approved for Mechanically Fastened Metal Roofing,Wood Shake&Shingles,Asphalt
Shingles, Slate, Simulated Slate
i
i
'f
I
I
i
'i
i
NOA No.: 18-0329.03
MIAmt-oADE couNW
Expiration Date:.09/29/20
Approval Date: 06/28/18
Page 4 of 7
r
j,
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32"or greater plywood or wood plank
System E(2): Base sheet mechanically fastened,membrane adhered.
I
Base Sheet: One or more plies of ASTM D226 Type 11 or ASTM 02626 with a minimum 4" side lap and
a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at,the
laps and two staggered rows 12"o.c. the field of the roll..
Membrane: One ply of Lastobond TU HT with minimum 3-inch side laps and 6-inch end laps. Starting
at the first course,parallel to the eave, align the membrane carefully by completely unrolling
and setting it exactly where it will be installed. Once aligned,rewind one half of the length.
Gently score the release paper on the high side of this roll,ensuring not to cut through the
membrane's thickness. Unroll this first half by evenly peeling back the release paper,while
simultaneously and slowly pushing out the membrane. Repeat process for remaining one
half of the length. Once installed,the membrane must be pressure rolled with a metal,or
rubber roller. Pressure shall be applied over the entire surface,paying particular attention to
all side and end laps.
The Lastobond TU HT shall be back nailed to deck with approved annular ring shank nails
and tin caps at a maximum 12"o.c. at the side laps and 6" o.c. at the end laps. No nails or
tin caps shall be exposed.
Surfacing: Approved for Mechanically Fastened Cement or Clay Roof tiles.Lastobond TU HT may be
used with any approved roof tile system adhered as specified in their current NOA using any
foam adhesive listed and having a current adhesive NOA approval.
f
f
1
C
,f
t
I
i
I
!I
,i
i
I
j
i
I
NOA No.:'18-0329.03
MIAMt•nc,dE cou11
Expiration Date: 09/29/20
Approval Date:06/28/18
Page 5 of 7
�I
j
i�
I '
I
LIMITATIONS: 'I
1. Fire classification is notlpart of this acceptance.
w
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
the applicable building code. Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond
Shield HT,Lastobond Pro HT-S,EnviroShield,Lastobond TU HT Lastobond 195, Lastobond Eaves Protection
Sheet,Lastobond Smooth Seal HT,Resisto LB1236 or Resisto LB 1244 shall be installed in strict compliance with
the applicable building code.
3. Lastobond Shield, Lastobond Pro HT N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,
EnviroShield,Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,
Resisto LB 1236 or Resisto LB 1244 shall be applied to a smooth,clean and dry surface,free from irregularities.
Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application. When a smooth, clean and/or dry surface cannot be obtained,the
substrate shall be primed with Elastocol Stick prior to application..
4. Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro UT-S,
EnviroShield,Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,
Resisto LB 1236 or Resisto LB 1244 shall not be applied over an existing roof membrane as a recover system but
may be applied over a roofing Base/Anchor sheet underlayment.
5. Lastobond TU HT is acceptable for use in foam adhesive set and mechanically fastened roof tile systems as
specified in the surfacing option of the approved assemblies.
6. Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB 1236 or Resisto
LB 1244 shall not be left exposed as a temporary roof for longer than 30 days.
7. Lastobond Shield HT,Lastobond Pro HT-S,EnviroShield,Lastobond Shield,Lastobond Pro HT-N and Resisto
SA Smooth Ply 40 shall not be left exposed as a temporary roof for longer than 90 days of application.
8. Lastobond TU HT shall not be left exposed as a temporary roof for longer than 180 days of application.
9. Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,
EnviroShield,Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,
Resisto LB 1236 or Resisto LB 1244 may be used with any approved roof covering listing Lastobond Shield,
Lastobond Pro HT-N,;Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,EnviroShield,
Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto
LB 1236 or Resisto LB 1244 within the Product Approval. If Lastobond Shield,Lastobond Pro HT-N,Resisto SA
Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,EnviroShield,Lastobond TU HT,Lastobond 195,
Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB 1236 or Resisto LB 1244 is not listed,
a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control
Department for approval based on the necessary documentation to detail compatibility of the products,wind uplift
resistance and fire resistance results. j
10. When applying the membrane in the valley, start at the low point and work to the high point,rolling the
membrane from the center outward in both directions. For ridge applications,center the membrane and roll from
the center outwards in both directions.
11. Membrane shall be applied to protrusions, slope changes, valley,curb, and other roof top penetration details
before any other sections of the roof.
12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the'Florida Administrative Code.
CM �CO ±:. NOA No.:'18-0329.03
Expiration Date: 09/29/20
Approval Date: 06/28/18
! ` Page 6 of 7
i
i
f
i
13. Tiles must be staged ontoLastobond TU HT not to exceed 10-high;to the standard maximum roof pitch of 6:12
for flat tiles and 5:12 for lugged tiles. Lugged tiles staging at slope>5:12 shall use alternate staging method
(bottom tile shall be inverted followed by eight tiles high on slope,;as illustrated in Figure 1 below). '
}
.. i
aye. Lti`
Figure 1: Alternate Staging Method
At roof slopes greater than the preceding limitations all tiles shall be loaded onto a nominal 1"x 2"horizontal
batten to prevent slippage.
14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
P � g p g g ,
city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
Min,rtI-RADE caurrrr
END OF THIS ACCEPTANCE
'i
r
i
NOA No.: 18-0329.03
MIAMI-DADE COUNTY { Expiration Date: 09/29/20
� p.
i
Approval Date:06/28/18
I Page 7 of 7
i .