Loading...
HomeMy WebLinkAboutProduct Approval Business Professional Regulation BCIS Home I Lag In 1 User Registration I Hot Topics Submit Surcharge Stats&Facts i Publications Contact Us SCIS Site Map [Inks Search Florida `�i� Product Approval gopr � USER:Public User Product Aooroval Menu>Product or Aoollcatlon Search>Aoolication List>Application Detail _ FL# FL1654-R23 RECEIVED Application Type Revision Code Version 2017 OCT 2 9 2 019 Application Status Approved Comments ST, Lucie County, Permitting Archived L� Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W.Newport Center Drive �� Deerfield Beach,FL 33442 Yl yl (954)233-1330 Ext 242 malpert@polyglass.com REVIEWED FOR Authorized Signature Maury Alpert CODE malpert@polyglass.com CC OMPLIA CE Technical Representative Maury Alpert ST. LUCIE COUNTY Address/Phone/Email 1111 W.Newport Center Drive Deerfield Beach,FL 33442 B®CC W (912)429-8610 MA[pert@polyglass.com Quality Assurance Representative Elle Copy Address/Phone/Email f�'qff? Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer. CJ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Robert Nieminen Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/13/2021 Validated By John W.Knezevich,PE L6 Validation Checklist-Hardcopy Received Certificate of Independence FL1654 R23 COI 2018 01 COI NIEMINEN Ddf Referenced Standard and Year(of Standard) Standard Year ASTM D6162 2008 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2009 FM 4470 2012 FM 4474 2011 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/08/2018 Date Validated 10/13/2018 Date Pending FBC Approval 10/21/2018 Date Approved 12/11/2018 Date Revised 04/12/2019 Summary of Products FL# Model,Number or Name Description 1654.1 Polyglass SBS and APP Modified Bitumen Roof SBS and APP modified bitumen roof systems Systems Limits of Use Installation Instructions Approved for use in HVHZ:No FI 1654 R23 ii 2018 10 FINAL Al ER POLYGLASS MODBIT FL1654- Approved for use outside HVHZ:Yes R23.Ddf Impact Resistant:N/A Verified By:Robert Nieminen PE-59166 Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes Other:1.)The design pressure in this application relates to one particular Evaluation Reports assembly over concrete deck.Refer to the ER Appendix for other systems and F'165 022 AE 2018 10 INAL LR POLYG AAASS MODBIT FI 1644-P2a 0df deck types.2.)Refer to ER,Section 5 for other Limits of Use. Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850.487-1824 The State of Florida is an AA/EEO employer.Copyright 2007.2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: rMi®MEN � Credit Card Safe n E'EIVED OCT 292019 NEMO I etc. ST. Lucie County, Permittin ificate ofAuthorizotion#32455 353 Christian Street, Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION Polyglass USA,Inc. Evaluation Report P9290.02.08-1121 150 Lyon Drive FL1654-R23 Fernley, NV 89408 Date of Issuance:02/11/2008 (954)233-1330 Revision 21:10/08/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 61h Edition(2017) Florida Building Code sections noted herein. DESCRIPTION:I Polyglass SBS-and APP_Modified Bitumen Roof Systems LABELING:. Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.of any changes to the product(s),the Quality Assurance or the production facility location(s). NEIVIO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 65-page Appendix. Prepared by: ,1q),tt4ilt rr+h Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert ":aS,� ��` '• Nieminen,P.E.on 10/08/2018.This does not serve as an Florida Registration No.59166,Florida DCA ANE2983 electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. z ONEMOletc. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems,as produced by Polyglass USA, Iric., have demonstrated compliance with the following sections of the 611 Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section - Property Standard Year 1504.3.1 Wind. FM 4474 2011 1504.3.1 Wind UL 1897 2012 1504.7 Impact FM 4470 2012 1507.11.2 Physicals ASTM D6162 2008 1507.11.2 Physicals ASTM D6163 2008 1507.11.2 Physicals ASTM D6164 2011 1507.11.2 Physicals ASTM D6222 2011 1507.11.2 Physicals ASTM D6509 2009 3. REFERENCES: - - - - Enti Exam Reference Date Enti Exam Reference Date ERD(TST6049) Physicals P10490.10.08-2 10/30/2008 FM(TST1867) FM 4470 2DOAO.AM 12/23/1998 ERD(TST6049) FM 4470/4474 P13760.09.09 09/10/2009 FM(TST1867) FM 4470 2DSA9.AM 06/22/1999 ERD(TST6049) FM 4470/4474 P13770.09.09 09/10/2009 FM(TST1867) FM 4470 3006646 01/04/2000 ERD(TST6049) FM 4470/4474 P30540.31.09-R1 11/30/2009 FM(TST1867) FM 4470 3001334 01/25/2000 ERD(TST6049) FM 4470/4474 P30550.12.09 12/02/2009 FM(TST1867) FM 4470 3001334 02/15/2000 ERD(TST6049) Physicals P33960.12.10 12/30/2010 FM(TST1867) FM 4470 3000857 01/12/2000 ERD(TST6049) FM 4470/4474 P33970.03.11 03/15/2011 FM(TST1867) FM 4470 3004091 01/12/2000 ERD(TST6049) Physicals P37590.03.13-3A 03/06/2013 FM(TST1867) FM 4470 3006115 05/02/2001 ERD(TST6049) FM 4470/4474 P39680.03.13 03/04/2013 FM(TST1867) FM 4470 3012321 07/29/2002 ERD(TST6049) Physicals P37590.03.13-1-R1 06/26/2013 FM(TST1867) FM 4470 3014692 08/05/2003 ERD(TST6049) Physicals P37590.03.13-2-RS 07/01/2013 FM(TST1867) FM 4470 3014751 08/27/2003 ERD(TST6049) Physicals P37590.07.13-2 07/01/2013 FM(7571867) FM 4470 3007170 01/13/2004 ERD(TST6049) Physicals P37590.03.13-5-R1 07/01/2013 FM(TST1867) FM 4470 3019317 06/30/2004 ERD(TST6049) Physicals P37590.07.13-1 07/02/2013 FM(TST1867) FM 4470 3020703 07/30/2004 ERD(TST6049) FM 4470/4474 P41630.08.13 08/06/2013 FM(TST1867) FM 4470/4474 3018332 01/31/2006 ERD(TST6049) Physicals P45940.09.13 09/04/2013 FM(TST1867) FM 4470/4474 3023368 03/20/2006 ERD(TST6049) Physicals P44370.10.13 10/04/2013 FM(TST1867) FM 4470/4474 3024594 05/23/2006 ERD(TST6049) Physicals P39520.09.14-2 09/11/2014 FM(TST1867) FM 4470/4474 3023458 07/18/2006 ERD(TST6049) FM 4470/4474 SC6160.11.14 11/10/2014 FM(TST1867) FM 4470/4474 3030668 09/12/2007 ERD(TST6049) Physicals P45440SC.03.15-1 03/31/2015 FM(TST1867) FM 4470/4474 3032172 06/12/2009 ERD(TST6049) Physicals SCS170.05.15 05/08/2015 FM(TST1867) FM 4470/4474 3049631 04/21/2014 ERD(TST6049) FM 4474 SC8085.05.15 05/19/2015 FM(TST1867) FM 4470/4474 3057029 02/02/2017 ERD(TST6049) Physicals SC5170.12.15 12/29/2015 NEMO(TST6049) Criticality 4S-PLYG-18-001.06.18 06/23/2018 ERD(TST6049) FM 4470/4474 SC9455.15 04/01/2016 NEMO(TST6049) FM 4474 4L-PLYG-18-003.08.18 08/21/2018 ERD(TST6049) FM 4470/4474 PLYG-SC8905.05.16-1 05/17/2016 NEMO(TST6049) FM 4474 PLYG-Cl,C3,cn,C5,C8 09/21/2018 ERD(7576049) FM 4470/4474 PLYG-SC8905.05.16-2 05/17/2016 NEMO(TST6049) Criticality 4S-PLYG-18-001.10.18 10/03/2018 ERD(TST6049) FM 4470/4474 PLYG-SC10815.07.16-R1 09/23/2016 PRI(TST5878) Physicals PUSA-062-02-01 12/04/2007 ERD(TST6049) UL 1897 PLYG-SC12025.10.16 10/12/2016 PRI(TST5878) Physicals PUSA-061-02-02 01/28/2008 ERD(TST6049) FM 4470/4474 PLYG-SC11475.16 11/17/2016 PRI(TST5878) Physicals PUSA-064-02-02 02/27/2008 ERD(TST6049) FM 4470/4474 PLYG-SC13235.01.17 01/17/2017 PRI(TST5878) Physicals PUSA-062-02-02 12/04/2008 ERD(TST6049) FM 4470/4474 PLYG-SC13920.05.17 05/30/2017 PRI(TST5878) TAS 114 PUSA-188-02-01 02/08/2017 ERD(TST11294) FM 4470/4474 PLYG-CTL13945.05.17-1 05/30/2017 PRI(TST5878) TAS 114 PUSA-188-02-02 02/08/2017 ERD(TST11294) FM 4470/4474 PLYG-CTL13945.05.17-3 05/30/2017 PRI(TST5878) TAS 114 PUSA-188-02-03 02/08/2017 ERD(TST6049) FM 4470/4474 PLYG-SC13945.05.17 05/30/2017 PRI(TST5878) TAS 114 PUSA-202-02-01 05/17/2017 ERD(TST6049) FM 4470/4474 PLYG-SC15760.09.17 09/11/2017 PRI(TST5878) TAS 114 PUSA-202-02-02 05/17/2017 FM(TST1867) FM 4470 2W7A7.AM 08/04/1994 M-D(CER1592) HVHZ Various NOAs Various FM(TST1867) FM 4470 OD3A3.AM 04/04/1997 M-D(CER1592) Prop.for Rev. 10-0823 10/12/2010 UL(QUA9625) Quality Control Service Confirm 09/13/2018 NEMO ETC,LLC Evaluation Report P9290.02.08-R21 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL1654-R23 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Revision 21:10/08/2018 Page 2 of 4 ONEMOletc. 4. '••DDESCRIPTION: This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. TABLE 1:ROLL-GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Grade Type Polyglass G2 Base ASTM D4601 N/A II Base Sheets Polyflex SA Base ASTM D4601 N/A II Polyglass APP Base ASTM D6509 N/A N/A Polyglass HT Base 650 ASTM D6162 S III Elastobase ASTM D6163 S I Elastoflex V ASTM D6163 S I (Elastoflex SA V Basel (ASTM D6163,Table 2} (S) (1) Elastoflex SA V FR Base ASTM D6163,Table 2" S I SBS Membranes Elastoflex SA V Plus ASTM D6163 S I. Elastoflex SA V Plus FR ASTM D6163 S I .Elastobase Poly ASTM D6164 S I Elastoflex S6 ASTM D6164 S I Elastoflex S6 Type II ASTM D6164 S II Elastoflex VG ASTM D6163 G I Elastoflex VG FR ASTM D6163 G I Elastoflex S6 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G I Polyfresko G SBS(sand or poly-film back) ASTM D6164 G I Polyfresko G SBS FR(sand or poly-film back) ASTM D6164 G I SBS Membranes Elastoshield TS G ASTM D6164 G I Elastoshield TS G FR ASTM D6164 G I (Elastoflex5A-Pi (ASTM D6164) (G) (I} Elastoflex SA P FR ASTM D6164 G I Polyreflect ASTM D6164 S I Polyflex ASTM D6222 S I Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G I Polyfresko G ASTM D6222 G I Polyfresko G FR ASTM D6222 G I APP Membranes Polybond ASTM D6222 S I Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G I Polyflex SA P FR ASTM D6222 I G I Polyfresko G SA ASTM D6222 G I Polykool ASTM D6222 S II 5. • • 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations,foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. NEMO ETC,LLC Evaluation Report P9290.02.08-1121 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL1654-R23 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Revision 21:10/08/2018 Page 3 of 4 ONEMOletc. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations,the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question,field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through,field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(l),1609.3(2)or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 611320-3. 6. INSTALLATION: 6.1 Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions,subject to the Limitations/Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. REQUIREMENTS:7. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C.Rule 61G20-3 QA requirements 9. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(314)578-3406,k.chancellor@us.ul.com -THE 65-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 139290.02.08-1121 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL1654-R23 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Revision 21:10/08/2018 Page 4 of 4 ONEMOjetc. APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5 1B Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5-9 1C Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 10-11 1D Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 12 1E Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 12-14 IF Wood New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 15-17 IG Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 18-21 IH Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover. 21-25 11 Mood ew or Reroof_(Tear-Off)) !J INon-lnoulated,Bo'nde_d Roof Cover i26) 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 27-29 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 30-34 2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 35-37 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 38-46 3B Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 46 4A Lightweight concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 47-49 4B Lightweight concrete New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 50 4C Lightweight concrete New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 51-53 5A Cementitious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 54 5B Cementitious wood fiber New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 55 5C Cementitious wood fiber New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 56 SD Cementitious wood fiber New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 56 5E Cementitious wood fiber New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 56 6A Existing gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 57-59 6B Existing gypsum Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 59 6C Existing gypsum Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 60 61) Existing gypsum Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 60 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 61-65 7B Various I Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 65 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement: ➢Wood: Minimum 0.75-inch penetration. ➢Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. NEMO ETC,LLC Evaluation Report P9290.02.08-R21 for FL1654-RZ3 Certificate of Authorization#32455 CH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 21:10/08/2018 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 1 of 65 ONEMOletc. 3. Unless otherwise noted,insulation maybe anyone layer or combination of polyisocya nu rate,polystyrene,wood fiberboard,perlite,gypsum-based roof board or mineral-wool roof board that meets the CIA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural _ members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016). 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt(HA): Full coverage at 25-30 lbs/square. ➢ Dow INSTA STIK Quik Set Insulation Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. ➢ Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. ➢ Millennium PG-1 Pump Grade Adhesive(M-PG1): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. ➢OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢OlyBond Classic(OB Classic): Full coverage at 1 gal/square. ➢ ICP Adhesive&Sealants Polyset CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c. ➢Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocya n u rate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick) ➢ Millennium PG-1 Pump Grade Adhesive(M-PGI): MDP -157.5 psf (Min.0.5-inch thick) ➢ OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3) ➢ OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL) ➢ OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-Inch thick ENRGY 3) ➢OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-inch thick ACFoam II) ➢ ICP Adhesives&Sealants Polyset CR-20: MDP -117.5 psf (Min.1.0-inch thick) 8. Bonded polyisocya n u rate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk'carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 10. For fully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 11. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application. NEMO ETC,LLC Evaluation Report P9290.02.08-R21 for FL1654-RZ3 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 21:10/08/2018 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 2 of 65 ONEMOjetc. 14. Lightweight Insulating Concrete(LWC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced,refer to current LWC Product Approval for specific deck construction and limitations. Unless otherwise noted,for systems where specific LWC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent'LWC references,listings were established through testing over lightweight concrete cast using only foaming agent(ASTM C896),water and Portland cement(ASTM C150),with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO(FBC CER1592). Unless otherwise noted, use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. POLYGLAss ROOF COVERS REFERENCE LAYER MATERIAL APPLICATION BP-AA Base Ply One or more plies Polyglass G2 Base,FBC Approved ASTM D4601,Type II Hot Asphalt at 20-40 (Base and Ply sheets, Ply One or more plies Polyglass Ply IV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV or VI lbs/square Asphalt-Applied) Note: Asphalt-applied sheets or insulation shall not be applied to poly film surfaced membranes. Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 Type II,Polyglass HT Base 650 PG350 at 1.5-2.0 SBS-CAI Cap Ply Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 Type II,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G,Elastoshield gal/square TS-G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 Type II Polyplus 35 at 1.5-2.0 SBS-CA2 Cap Ply Elastoflex VG,Elastoflex VG FR,Elastoflex 56,Elastoflex 56 Type II,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G,Elastoshield gal/square TS-G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) Base Ply or Ply One or more plies Elastobase(sand/sand or poly/sand),Elastobase P(sand/sand or poly/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 Type Il,Polyglass HT Base 650 SBS-AA Elastoflex V,Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 Type ll,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G, Hot Asphalt at 20-40 (SBS,Asphalt-Applied) Cap Ply Elastoshield TS-G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) lbs/square Note: Asphalt-applied sheets or insulation shall not be applied to poly-film surfaced membranes. Base Ply or Ply One or more plies Elastobase(sand/poly),Elastobase(poly/poly),Elastoflex V,Elastoflex S6,Elastoflex S6 Type II,Polyglass HT Base SBS-TA Torch-Applied (SBS,Torch-Applied) Elastoflex V,Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 Type II,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS- Cap Ply G,Elastoshield TS-G FR,Polyfresko G SBS(poly-film backed),Polyfresko G SBS FR(poly-film backed) (Base Ply) (One or more pliesElasoflez SA V Base,Elastoflex 5A V FR Base,Elastoflex SAV Plus,Elastoflex 5A V Plus FR) +SBS-SAI Iap Ply) (Elasoflez SA P,Elastoflex SA P FR,Polyreflect ISeIf-AdheRin`gl ((SBS,Self-Adhering)) Note: Lnless otherwise noted,-permissible membrane substrates fo�SeS=SA are limited to`the 585-5A Bos`e Ply options herein,) (Elastobase(poly/sand)or Elastobase(poly/poly)1 APP-CA1 Cap Ply Polyflex G FR PG350 at 1.5-2.0 gal/square APP-TA Base Ply or Ply One or more plies Polyglass APP Base,Polyflex,Polybond (APP,Torch-Applied) Cap Ply Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR Torch-Applied APP-SA Cap Ply Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polykool Note: Unless otherwise noted,permissible membrane substrates forAPP-SAare limited to the SBS-SA Base Ply options herein, Self-Adhering (APP,Self-Adhering) Elastobase(poly/sand)or Elastobase(poly/poly). NEMO ETC,LLC Evaluation Report P9290.02.08-R21 for FL1654-R23 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 21:10/08/2018 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 3 of 65 ONEMOletc. TABLE 11: WOOD DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Deck(Note 1) Primer Roof Cover(Note 15) MDP(psf) No. Joint Treatment Base Ply Ply Cap Ply Min.15/32- (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- W-170 inch plywood None None SBS-SA TA,APP-TA TA,APP-TA 90.0 W-171 Min.15/32- (Optional)PG100 None Polyfiex SA Base (Optional)APP-TA APP-TA -90.0 inch plywood W-172 Min.15/32- PG100 None SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -97.5 inch plywood TA,APP-TA TA,APP-TA Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -97.5 W-173 inch plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V FR Base TA,APP-TA TA,APP-TA Min.15/32- (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- W 174 inch plywood POLYBRITE 745 None SBS-SA 105.0 TA,APP-TA TA,APP-TA L-1 lMh.15_/32 ((Optional)PG]001 (Plywood joints are covered with 4-inch wide strips of EI stofle'x_SA V Plus,rolled int? (Elastoflex SA V Plus or (Optional)SBS-SA—SBS] SBS 5A APP-SA,SBS X135 01 finch plywood! dace to create continuous bond. (Elastoflex SAV Plus FRl rTA,APP_TAI iTA,APP-TAI W-176 Min.15/32- (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Polyflex SA Base (Optional)APP-TA APP-TA -135.0 inch plywood place to create continuous bond. NEMO ETC,LLC Evaluation Report P9290.02.08-R21 for FL3654-R23 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 21:10/08/2018 Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 26 of 65