a. FL # FL5889-R4
Application Type Affirmation
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Shwinco Architectural Products, LLC
1711et Services Way
Dothan, AL 36303
(334) 556-1000
engineering@shwinco.com
Keith Schneider
engineering@shwinco.com
Craig Shipp
400 Aberdeen Loop
Lynn Haven, FL 32444
(850) 271-8900
shwinco@knology.net
Craig Shipp
400 Aberdeen Loop
Panama City, FL 32405
(850)271-8900
shwinco@knology.net
Windows
Mullions
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
.: Evaluation Report - Hardcopy Received
Gene Kearley
PE-52484
National Accreditation and Management Institute
12/31/2019
Locke Bowden P.E.
Validation Checklist - Hardcopy Received
FL5889 R4 COI Enaineering__Rgnnrt 2015-OOD4.pdf
Referenced Standard and Year (of Standard) Standard
TAS 201
TAS 202
TAS 203
Equivalence of Product Standards
Certified By
Year
1994
1994
1994
https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquh2fUh7Qf10gtgwk5v4ACAgNbiFmgYg2JBG%3d 112
617/2019 Florida Building Code Online
Sections from the Code
I affirm that there are no changes in the new Florida Building
Code which affect my product(s) and my product(s) are in
compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity <.. yes No N/A
FL5889 R4 CDC 5889 R4 NOA 2017-0007.Ddf
Product Approval Method Method 1 Option D
Date Submitted 10/02/2017
Date Validated 10/02/2017
Date Pending FBC Approval
Date Approved 10/OS/2017
Summary of Products
FL # Model, Number or Name
Description
5889.1 SERIES II MULLION
ALUMINUM REINFORCED MULLION -IMPACT
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5889 R4 lI SAP.M.1001 Dwg,W
I Approved for use outside HVHZ: Yes
Verified By: Gene Keadey FLORIDA PE 52484
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
other: REFER TO SAP.M.1001 FOR Specific Design Pressure
i FL5889 R4 AE Engineerin Uport 2015-0004 piff
'
and Limits of Use.
Created by Independent Third Party: Yes
Esc txexr
Contact Us :: 2601 Blair Stone Read Tallahassee FL 32399 phone $50-497-1824
The State of Florida is an AA/EEO employer. QMyYght 2007-2013 Shape of Florida.:: pi v Statement :: AccesslbillN Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records re9uesk, do not Bard electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.467.1395. *Pursuant to Section 455.275(1),
Honda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department win an email address if they have one. The emails
providedl may be used for official communication with the licensee, However email atlaresses are public record If you do not wish to supply a personal address, please
provide the Department with an email address whidi can be made available to the public. To determine if you are a licensee under Chapter 455, FS., please click Lere.
product Approval Accepts:
0 R 0
credit Card
$'df8
https:IAw.floridabuilding.org/pr/pr_app_dtl.aspx?pamm=wGEVXQwtDqu%2fLJh7Qfi Ogtgwk5v4AQ4gNbiFmgYg2JBQ%3d 212
u { xa3,a f�gl Z o
f y O M
W j< t( 32 W IL i6 j WJJJ Q W
C I a i o, �' �tia A8 NOIldStAS34 'ON a N y
Z:c
co
H O
N
W
C. C
W
U)
I�
z�
P
3
ti�
P
0 %
U2
Gene Kearley, P.E.
319 Chapelwood Drive
Dothan, AL 36305
FLA No.52484
Manufacturer: Shwinco Architectural Products, LLC
171 Jet Services Way
Dothan, AL 36303
Product Line: Series II Mullion (IMPACT}
Engineering Evaluation Report
Report No. : 2015-0004
FL 5889
Maximum Dimensions & Design pressure: (See drawing SAP.M.1001, Sheet 1, Details 1, 2, & 3)
Compliance:
The above mentioned product has been evaluated under method 1(d) for compliance with the
requirements of the Florida Department of Business and Professional Regulation for Statewide
Acceptance. The product listed herein complies with requirements of the Florida Building Code including
the "High Velocity Hurricane Zone" (HVHZ).
Gene Kearley, P.E. does not have nor will acquire financial interest in the company manufacturing or
distributing the product or in any other entity involved in the approval process of the product named
herein.
Supporting Technical Documentation:
1. Approval Document: Drawing SAP.M.1001 signed and sealed by Gene R. Kearley, P.E. (FL #
52484). Drawing SAP.M.1001 should be referenced for all specific use parameters.
2. Test Data:
la
C.
Product Test Report #0722.01-03, Report Date:10/02/03.
American Test Lab of South Florida, Inc. (FBC Organization # T5T3782)
Product Test Report #NCTL-210-3587-2, Report Date: 08/24/09.
National Certified Testing Laboratories, Inc. (FBC Organization # TST1589)
Product Test Report #NCTL-210-3850-1, Report Date: 12/18/12.
National Certified Testing Laboratories, Inc. (FBC Organization # TSTA
3. Test Standards
a. TAS 201-94
b. TAS 202-94
c. TAS 203-94
Report No. :
1 of 2
4. Quality Assurance
a. National Accreditation and Management Institute (FBC Organization #QUA 1789)
Installation:
Mullion Clip Option
A. For concrete or masonry substrates where one -by (lx), non-structural, wood bucking is
employed, or is directly fastened to concrete, use %" diameter Elco Ultracon (or equal) type
concrete screw anchors of sufficient length to achieve a minimum embedment of 1.25" into
concrete or masonry substrates.
B. For two -by (2x) wood frame substrate, use #12 pan head wood screws of sufficient length to
achieve minimum embedment of 1.5" into wood framing.
Unclipped Mullion Option
A. When installing the series 9000 for a maximum design pressure of a positive 60 and a
negative 70 using unclipped mullions, all mullion fastening load is transferred to the
fastening requirements of the associated window units as tested. The maximum window
dimensions, associated with this unclipped mullion, are 74" in width and 74" in height. Use
is limited to 74" long mullions with the maximum tributary width of 36 5/8". Fastener
guidelines shall be governed by fastener requirements of the associated window unit.
Limits of use:
1. This product has been evaluated and is in compliance with the Florida Building Code, including
the "High Velocity Hurricane Zone" (HVHZ).
2. The product anchors shall be as listed and spaced as shown on the details. Anchor embedment
into the substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with the
Florida Building Code and does not require an impact resistant covering.
4. Site conditions that deviate from details of drawing SAP.M.1001 require further engineering
analysis by a licensed engineer or registered architect.
S. See drawing SAP.M.1001 for size and design pressure limitations.
Gene Kearley, P.E.
Florida No. 52484
Report No.; 2015-0004
2of2